• Title/Summary/Keyword: Water Column

Search Result 2,046, Processing Time 0.029 seconds

Isolation of Angiotensin Converting enzyme inhibitors from Ripe Cucurbita moschata Duch

  • Hyeyoung Jung;Song, Kyung-Bin
    • Preventive Nutrition and Food Science
    • /
    • v.6 no.4
    • /
    • pp.244-246
    • /
    • 2001
  • Angiotensin converting enzyme (ACE) inhibitor acts on the inhibition of ACE and causes a decrease in blood pressure. There have been several reports on screening of ACE inhibitors from natural food products and protein hydrolysates of various food sources. Ripe Cucurbita moschata Duch has been used as an oriental medicine in Korea. To isolate ACE inhibitors, crude water extracts of the edible portion of ripe Cucurbita moschata Duch were obtained after heating in water at 95$^{\circ}C$ for 2 h. Crude extracts were then filtered using PM-10 and YM-1 membranes. The membrane-filtered solution was loaded onto Sephadex G-15 column equlibrated with a phosphate buffer. Among the four major fractions of gel permeation chromatography, the second fraction had the highest inhibitory activity of 65%. Further purification of the fraction using reversed-phase HPLC with a $C_{18}$ column produced ACE inhibitors, which were identified as a mixture having molecular mass of 222 and 273 by Tandem mass spectrometry.

  • PDF

Effect of Internal Fluid Resonance on the Performance of a Floating OWC Device

  • Cho, Il Hyoung
    • Journal of Ocean Engineering and Technology
    • /
    • v.35 no.3
    • /
    • pp.216-228
    • /
    • 2021
  • In the present study, the performance of a floating oscillating water column (OWC) device has been studied in regular waves. The OWC model has the shape of a hollow cylinder. The linear potential theory is assumed, and a matched eigenfunction expansion method(MEEM) is applied for solving the diffraction and radiation problems. The radiation problem involves the radiation of waves by the heaving motion of a floating OWC device and the oscillating pressure in the air chamber. The characteristics of the exciting forces, hydrodynamic forces, flow rate, air pressure in the chamber, and heave motion response are investigated with various system parameters, such as the inner radius, draft of an OWC, and turbine constant. The efficiency of a floating OWC device is estimated in connection with the extracted wave power and capture width. Specifically, the piston-mode resonance in an internal fluid region plays an important role in the performance of a floating OWC device, along with the heave motion resonance. The developed prediction tool will help determine the various design parameters affecting the performance of a floating OWC device in waves.

Removal of Heavy Metals, Cd(II) and Pb(II) Ions in water by Sargassum Herneri (괭생이 모자반에 의한 수중 중금속 Cd(II), Pb(II) 이온의 제거)

  • Park, Kwang-Ha;Park, Mi-A;Jang, Hoon;Kim, Eun-Kyung;Kim, Young-Ha
    • Analytical Science and Technology
    • /
    • v.12 no.3
    • /
    • pp.196-202
    • /
    • 1999
  • Brown algae, Sargassum horneri, was used as an adsorbent to remove heavy metal Cd(II) and Pb(II) ions. Sargassum horneri picked in East Coast was formulated into the grain with the size of 40-60 mesh after wind dry. Batch method was used in order to investigate the adsorption rate by measuring the adsorption amounts with shaking time. In the column method, the adsorption amounts were measured by flowing metal solutions into the algae-packed column at the rate of 1 ml/min. Adsorption amounts in both batch method and column method were in the following order : pH 10.5>7.0>3.5. It was found that Pb(II) was more adsorbed on the algae grain than Cd(II). It was also revealed that the adsorption amounts reached the maximum within 5 minutes irrespective of pH condition in the batch method. It was concluded that the batch method was more effective than the column method in terms of recovery rate.

  • PDF

Effect of silver nanoparticles on the performance of riverbank filtration: Column study (강변여과에서의 은나노입자의 영향 : 실험실규모 컬럼 실험)

  • Lee, Donghyun;No, Jin-Hyeong;Kim, Hyun-Chul;Choi, Jae-Won;Choi, Il-Hwan;Maeng, Sungkyu
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.29 no.1
    • /
    • pp.77-88
    • /
    • 2015
  • Soil column experiments were evaluated effects of silver nanoparticles (i.e., 0, 2.5, 5, and 10 mg/L) on the microbial viability which is strongly associated with the degradation of organic matter, pharmaceutically active compounds(PhACs) and biological oxidation of nitrogenous compounds during river bank filtration. The addition of silver nanoparticles resulted in almost no change in the aqueous matrix. However, the intact cell concentration decreased with addition of silver nanoparticles from 2.5 to 10 mg/L, which accounted for 76% to 82% reduction compared to that of control (silver nanoparticles free surface water). The decrease in adenosine triphosphate was more pronounced; thus, the number and active cells in aqueous phase were concurrently decreased with added silver nanoparticles. Based on the florescence excitation-emission matrix and liquid chromatograph - organic carbon detection analyses, it shows that the removal of protein-like substances was relatively higher than that of humic-like substances, and polysaccharide was substantially reduced. But the extent of those substances removed during soil passage was decreased with the increasing concentration of silver nanoparticles. The attenuation of ionic PhACs ranged from 55% to 80%, depending on the concentration of silver nanoparticles. The attenuation of neutral PhACs ranged between 72% and 77%, which was relatively lower than that observed for the ionic PhACs. The microbial viability was affected by silver nanoparticles, which also resulted in inhibition of nitrifiers.

Scalants removal from synthetic RO brine using natural zeolite (막증류 공정의 전처리 공정으로서 천연 제올라이트 컬럼 적용)

  • Jeong, Seongpil;Chung, Hayoon;Yoon, Teakgeun;Lee, Seockheon
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.30 no.3
    • /
    • pp.279-284
    • /
    • 2016
  • Membrane distillation (MD) is the thermally driven water separation process based on the vapor pressure difference across the membrane. In order to increase the water recovery of the conventional RO process, the additional MD-PRO pocess was suggested. In this study, the syntheric RO brine was used as a feed solution of the MD process. Due to the high salinity of the RO brine, the MD membrane could be fouled by the scalants. In order to mitigate the scaling on the MD membrane surface, the pre-treatment process using the column filled by natural zeolite was applied. The roughing filter was installed between the pre-treatment process and MD system in order to prevent possible particulate fouling by the debries of the natural zeolite. Moreover, in order to enhance the CEC of the natural zeolite, the NaCl soaking was conducted. The flux and electronic conductivity were monitored under given experimental conditions. And the membrane morphology and the chemical compositions were analyzed by using the SEM-EDX.

Theory and Practices of Water Pollution Control by Wetland - a Case Study of Reed Wetland in Baiyangdian Lake

  • Li, Guibao;Zhou, Huaidong;Liu, Fang;Wang, Dianwu
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2004.05b
    • /
    • pp.72-76
    • /
    • 2004
  • Wetland is an important eco-system on the earth and can effectively control agricultural non-point source pollution. Reed is a typical wetland plant for land/inland water ecotone in north China. The studies indicated that reed had a underground rooted-stem, which formed a 'high speeded-connecting vessels' i.e. reed root channel (RRC) in Baiyangdian lake of Hebei province. It spread predominantly along horizontal direction underground and are mainly distributed at 18-75 cm. The results of field work from healthy reed-wetland (HRW) and regarded reed-wetland (RRW) showed that the reed, averagely, in HRW is 4.2 m height, 1 cm diameter, 65/m2 density; in RRW is 2.4 m height, 3 mm diameter, 86/m2 density. These results indicated the regradation of the function of RRC in RRW. The results of laboratory work of sewage purification from reed soil column (RSC) $(0\~100cm)$ and wheat soil column (WSC) showed that the efficiency of purification to sewage, in RSC, is high than in WSC, especially for phosphorus. The efficiency of purification, in RSC, is $92.6\%$ for total phosphorus, $43.5\%$ for total nitrogen, $54.1\%$ fur COD, respectively; in WSC, is $86.0\%$ for total phosphorus, $241.3\%$ for total nitrogen, $29.8\%$ for COD, respectively.

  • PDF

Nutrient dynamics study of overlying water affected by peroxide-treated sediment

  • Haque, Niamul;Kwon, Sung-Hyun
    • Journal of Ecology and Environment
    • /
    • v.41 no.9
    • /
    • pp.235-245
    • /
    • 2017
  • Background: Loading of excess nutrient via bioremediation of polluted sediment to overlying water could trigger anoxia and eutrophication in coastal area. The aim of this research was to understand the changes of overlying water features such as dissolved oxygen (DO); pH; oxidation reduction potential (ORP); $chlorophyll-{\alpha}$ ($Chl-{\alpha}$); and nitrogen nutrients ammonia ($N-NH_4{^+}$), nitrate ($N-NO_3{^-}$), and nitrite ($N-NO_2^-$) when the sediment was not treated (control) and treated by calcium peroxide for 5 weeks. Methods: The water samples were analyzed for measuring physical and chemical properties along with the sediment analyzed by polymerase chain reaction (PCR) including denaturing gradient gel electrophoresis (DGGE) for identifying the phylogenetic affiliation of microbial communities. Results: Results showed that due to the addition of calcium peroxide in sediment, the overlying water exposed the rise of dissolve oxygen, pH, and ORP than control. Among the nitrogen nutrients, ammonia inhibition was higher in calcium peroxide treatment than control but in case of nitrate inhibition, it was reversed than control. $Chlorophyll-{\alpha}$ was declined in treatment column water by 30% where it was 20% in control column water. Actibacter and Salegentibacter group were detectable in the calcium-peroxide-treated sediment; in contrary, no detectable community ware found in control sediment. Both phylogenetic groups are closely related to marine microflora. Conclusions: This study emphasizes the importance of calcium peroxide as an oxygen release material. Interaction with peroxide proved to be enhancing the formation of microbial community that are beneficial for biodegradation and spontaneity of nutrient attenuation into overlying water.

Laboratory Tests for Trichloroethylene (TCE) and Toluene Remediation in Soil Using Soil Vapor Extraction (토양증기추출(Soil Vapor Extraction)을 이용한 토양 내 Trichloroethylene (TCE)과 Toluene정화 실험)

  • 이민희;강현민
    • Economic and Environmental Geology
    • /
    • v.35 no.3
    • /
    • pp.221-227
    • /
    • 2002
  • Column experiments were performed to evaluate the removal efficiency of soil vapor extraction (SVE) iota TCE (trichloroethylene) and toluene in soil. Homogeneous Ottawa sands and real soils collected from contaminated area were used to investigate the effect of soil properties and SVE operation conditions on the removal efficiency. In column teats with two different sizes of Ottawa sand, the maximum effluent TCE concentration in a coarse sand column was 442 mg/L and 337 mg/L in a fine sand column. However, after 20 liter gas flushing, the effluent concentrations were very similar and more than 90% of initial TCE mass were removed from the column. For two real contaminated soil columns, the maximum effluent concentration decreased 50% compared with that in the homogeneous Ottawa coarse sand column, but 99% of initial TCE mass were extracted from the column within 40 liter air flushing, suggesting that SVE is very available to remove volatile NAPLs in the contaminated soil. To investigate the effect of contaminant existing time on the removal efficiency, an Ottawa sand column was left stable for one week after TCE was injected and the gas extraction was applied into the column. Its effluent concentration trend was very similar to those for other Ottawa sand columns except that the residual TCE after the air flushing showed relatively high. Column tests with different water contents were performed and results showed high removal efficiency even in a high water content sand column. Toluene as one of BTEX compounds was used in an Ottawa sand column and a real soil column. Removal trends were similar to those in TCE contaminated columns and more than 98% of initial toluene mass were removed with SVE in both column.