Development of Automatic Measurement and Control Method based on Single Chip Microcomputer for Tackjoo Fermentation (Single Chip Microcomputer를 이용한 탁주발효(濁酒醱酵)의 자동계측(自動計測)과 제어방법(制御方法)의 개발(開發))

  • Kim, Kyung-Man;Chun, Jae-Kun
    • Korean Journal of Food Science and Technology
    • /
    • v.25 no.4
    • /
    • pp.391-394
    • /
    • 1993
  • For the automation of Tackjoo fermentation, a sensor measurable gas production during brewing and a controller were built. The performance tests were carried out at 10 litter Tackjoo fermentor, The sensor was consisted of a transparent acryl cell for bubble formation and photo-interrupter for the detection of bubbles of 0.018ml size. The fermentation controller was fabricated with a single chip microcomputer (MC68705R3) and provided with both the monitoring module of temperature measurement and the valve controling device for the cooling water circulation in coil type heat exchanger. The operation programs were developed and systemized in ROM. With this computer system, the gas production amount and rate were acquired during the Tackjoo fermentation. The fermentation curve based on the gas production rate showed a good agreement with that of alcohol concentration. The maximum rate of gas production was found after 24 hr at $30^{\circ}C$. The correlation equation between the gas production and alcohol concentration was established and used as the control algorithm of the fermentation.

  • PDF

Review of Safety for Pressure-Relieving Systems of Small to Middle Scale Chemical Plants (중소규모 화학공장의 압력방출시스템에 대한 안전성 검토)

  • Yim, Ji-Pyo;Jin, Dae-Young;Ma, Byung-Chol;Kang, Sung-Ju;Chung, Chang-Bock
    • Journal of the Korean Society of Safety
    • /
    • v.30 no.6
    • /
    • pp.48-55
    • /
    • 2015
  • A variety of safety issues were investigated for chemical reactors using a toluene solvent in case of a fire at small to middle scale chemical plants. The issues covered the operation of pressure-relieving valves and the subsequent discharges of the toluene to the atmosphere either directly or through an absorber, which represent the current practice at most small chemical plants. It was shown that the safety valve on the reactor may not operate within about twenty minutes after an external fire breaks out, but, once relieved, the toluene vapor released directly to the atmosphere may form a large explosion range on the ground. It was also shown that if the discharge is routed to an existing absorber used for the scrubbing of volatile organic compounds or dusts, the column may not operate normally due to excessive pressure drops or flooding, resulting in the hazardous release of toluene vapors. This study proposed two ways of alleviating these risks. The first is to ruduce the discharge itself from the safety valve by using adequate insulation and protection covers on the reactor and then introduce it into the circulation water at the bottom of the absorber through a dip linet pipe equipped with a ring-shaped sparger. This will enhance the condensation of toluene vapors with the reduced effluent vapors treated in the packing layers above. The second is to install a separate quench drum to condense the routed toluene vapors more effectively than the existing absorber.

The Characteristics of Vacuum Drying Disks of Domestic Softwoods (I) (국산 침엽수재 원판(圓板)의 진공건조(眞空乾燥) 특성 (I))

  • Lee, Nam-Ho;Lee, June-Ho;Kim, Jong-Mann;Jung, Hee-Suk
    • Journal of the Korean Wood Science and Technology
    • /
    • v.24 no.2
    • /
    • pp.46-54
    • /
    • 1996
  • This study was carried out to investigate the vacuum drying characteristics of 50mm- and 75mm- thick tree disks of some domestic softwoods for substituting the conventional hardwoods as the materials for wood crafts. Though the elapsed drying times from green to in-use moisture content(MC) were largely shortened by vacuum drying, the tree disks treated by EWS couldn't be dried to in-use MC, and so sapwood stains also were occurred severely. We suggest EWS treatment is undesirable for the species with very high sapwood portion or vacuum drying with hot water circulation heating system. Heart checks were slight, but sapwood checks, which have never been trouble in drying process of tree disks, were severe. For the reasonable explanation it is suggested MC differences between sapwood and heartwood were large and most of tree disks had already no barks before drying test. Ginkgo was vacuum-dried with very slight drying defects such as heart checks, sapwood checks. V-cracks and sapwood stains. In Korean red pine and pitch pine V-cracks were severely occurred. And it was found the special feature that most of these defected tree disks contained several V-cracks within one tree disk. It can be considered as the causes that the region of sapwood was defected by the several checks at the early drying stage because of the steep MC gradient along the radial direction, and then at the later drying stage the drying stresses due to differential shrinkage were concentrated on these brittle spots.

  • PDF

A Study on Assessment Indicators for Integrated Management on Korea National Planning and Environmental Planning (국토계획과 환경계획 통합관리 지표 개발 연구)

  • Heo, Han-Kyul;Sung, Hyun-Chan;Lee, Dong-Kun;Heo, Min-Ju;Park, Jin-Han
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.21 no.3
    • /
    • pp.27-45
    • /
    • 2018
  • Both the national land plan and the environmental plan reflect the need for sustainable land use and management. However, the linkage between the plans is reduced due to the lack of integrated management. Therefore, this study developed indicators to achieve integrated management. A total of 59 environmental plans were reviewed for the development of indicators, and a total of 74 integrated management indicators were derived through a three-stage process. In this process, the relevance of the integrated management indicators of this study to the UN 's sustainable development goals (SDGs) is presented in order to derive indicators that meet the level of international consultation. In order to facilitate the utilization of the indicators, the final indicators are divided into seven areas: natural ecology, water resource and quality, urban and green space, atmospheric, energy, landscape, resource circulation and waste. Furthermore, the indicators were classified into national, regional, and city level. Accordingly, the final indicator can be adapted to the field of influence of the planned to be established, and the indicator can be selected and applied to the level of the plan. The final indicators can be used to examine the extent to which the national plan reflects the contents of the environmental plan and can be used as an aid to confirm the contents to be included in the plan when establishing a new national plan.

Evaluation of Reference Evapotranspiration in South Korea according to CMIP5 GCMs and Estimation Methods (CMIP5 GCMs과 추정 방법에 따른 우리나라 기준증발산량 평가)

  • Park, Jihoon;Cho, Jaepil;Lee, Eun-Jeong;Jung, Imgook
    • Journal of Korean Society of Rural Planning
    • /
    • v.23 no.4
    • /
    • pp.153-168
    • /
    • 2017
  • The main objective of this study was to assess reference evapotranspiration based on multiple GCMs (General Circulation Models) and estimation methods. In this study, 10 GCMs based on the RCP (Representative Concentration Pathway) 4.5 scenario were used to estimate reference evapotranspiration. 54 ASOS (Automated Synoptic Observing System) data were constructed by statistical downscaling techniques. The meteorological variables of precipitation, maximum temperature and minimum temperature, relative humidity, wind speed, and solar radiation were produced using GCMs. For the past and future periods, we estimated reference evapotranspiration by GCMs and analyzed the statistical characteristics and analyzed its uncertainty. Five methods (BC: Blaney-Criddle, HS: Hargreaves-Samani, MK: Makkink, MS: Matt-Shuttleworth, and PM: Penman-Monteith) were selected to analyze the uncertainty by reference evapotranspiration estimation methods. We compared the uncertainty of reference evapotranspiration method by the variable expansion and analyzed which variables greatly influence reference evapotranspiration estimation. The posterior probabilities of five methods were estimated as BC: 0.1792, HS: 0.1775, MK: 0.2361, MS: 0.2054, and PM: 0.2018. The posterior probability indicated how well reference evapotranspiration estimated with 10 GCMs for five methods reflected the estimated reference evapotranspiration using the observed data. Through this study, we analyzed the overall characteristics of reference evapotranspiration according to GCMs and reference evapotranspiration estimation methods The results of this study might be used as a basic data for preparing the standard method of reference evapotranspiration to derive the water management method under climate change.

Development of Complex Module Device for Odor Reduction in Sewage

  • KIM, Young-Do;JEONG, Tae-Hwan;Kim, Su-Hye;KWON, Woo-Taeg
    • Journal of Wellbeing Management and Applied Psychology
    • /
    • v.5 no.4
    • /
    • pp.51-56
    • /
    • 2022
  • Purpose: By applying an ultrasonic mechanical device to the liquid fertilizer storage in the pig dropping treatment plant, the initial odor of the odor source is reduced, and the air dilution drainage of the complex odor is fundamentally recognized to facilitate odor treatment on the mechanical and chemical biological treatment devices at the rear. Research design, data and methodology: The odor concentration on the site boundary was measured to confirm the state of reduction. In order to prevent the spread of odor from the collection of the pig dropping treatment plant, it was measured by installing an ultrasonic generator inside the installation wall after installing the sealing wall. Results: The average value of the March and April measurement data remained close to neutral at 8.2 after 8.6 treatment before pH treatment, decreased 97.3% from 462 mg/L before SS treatment to 10.5 mg/L after treatment, and the composite odor was reduced by 85% from 20 to 3 before treatment. It was confirmed that ammonia (NH3) was reduced by 99% from 5.8 ppm to 0.09 ppm, and general bacteria were also reduced by 99% from 3,200 CFU/mL to 57 CFU/mL Conclusion: Applying the ultrasonic air ejector hybrid system and zigzag air complex module development product to resource circulation centers or sewage treatment facilities is thought to reduce inconvenience to residents due to odors caused.

Implementation of Saemangeum Coastal Environmental Information System Using GIS (지리정보시스템을 이용한 새만금 해양환경정보시스템 구축)

  • Kim, Jin-Ah;Kim, Chang-Sik;Park, Jin-Ah
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.14 no.4
    • /
    • pp.128-136
    • /
    • 2011
  • To monitor and predict the change of coastal environment according to the construction of Saemangeum sea dyke and the development of land reclamation, we have done real-time and periodic ocean observation and numerical simulation since 2002. Saemangeum coastal environmental data can be largely classified to marine meteorology, ocean physics and circulation, water quality, marine geology and marine ecosystem and each part of data has been generated continuously and accumulated over about 10 years. The collected coastal environmental data are huge amounts of heterogeneous dataset and have some characteristics of multi-dimension, multivariate and spatio-temporal distribution. Thus the implementation of information system possible to data collection, processing, management and service is necessary. In this study, through the implementation of Saemangeum coastal environmental information system using geographic information system, it enables the integral data collection and management and the data querying and analysis of enormous and high-complexity data through the design of intuitive and effective web user interface and scientific data visualization using statistical graphs and thematic cartography. Furthermore, through the quantitative analysis of trend changed over long-term by the geo-spatial analysis with geo- processing, it's being used as a tool for provide a scientific basis for sustainable development and decision support in Saemangeum coast. Moreover, for the effective web-based information service, multi-level map cache, multi-layer architecture and geospatial database were implemented together.

A Study on Effect of Recirculated Exhaust Gas upon Performance and Exhaust Emissions in a Power Plant Boiler with FGR System (FGR 시스템 동력 플랜트 보일러의 성능 및 배기 배출물에 미치는 재순환 배기의 영향에 관한 연구)

  • Bae, Myung-whan;Jung, Kwong-ho;Park, Sung-bum
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.40 no.4
    • /
    • pp.263-273
    • /
    • 2016
  • The effect of recirculated exhaust gas on performance and exhaust emissions with FGR rate are investigated by using a natural circulation, pressurized draft and water tube boiler with FGR system operating at several boiler loads and over fire air damper openings. The purpose of this study is to apply the FGR system to a power plant boiler for reducing $NO_x$ emissions. To activate the combustion, the OFA with 0 to 20% is supplied into the flame. When the suction damper of two stage combustion system installed in the upper side of wind box is opened by handling the lever between $0^{\circ}$ and $90^{\circ}$, also, the combustion air supplied to burner is changed. It is found that the fuel consumption rate per evaporation rate did not show an obvious tendency to increase or decrease with rising the FGR rate, and $NO_x$ emissions at the same OFA damper opening are decreased, as FGR rates are elevated and boiler loads are dropped. While a trace amount of soot is emitted without regard to the operation conditions of boiler load, OFA damper opening and FGR rate, because soot emissions are eliminated by the electrostatic precipitator with a collecting efficiency of 86.7%.

Performance Improvement of Dielectric Barrier Plasma Reactor for Advanced Oxidation Process (고급산화공정용 유전체 장벽 플라즈마 반응기의 성능 개선)

  • Kim, Dong-Seog;Park, Young-Seek
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.34 no.7
    • /
    • pp.459-466
    • /
    • 2012
  • In order to improved treatment performance of dielectric barrier discharge (DBD) plasma, plasm + UV process and gas-liquid mixing method has been investigated. This study investigated the degradation of N, N-Dimethyl-4-nitrosoaniline (RNO, indicator of the generation of OH radical). The basic DBD plasma reactor of this study consisted of a plasma reactor (consist of quartz dielectric tube, titanium discharge (inner) and ground (outer) electrode), air and power supply system. Improvement of plasma reactor was done by the combined basic plasma reactor with the UV process, adapt of gas-liquid mixer. The effect of UV power of plasma + UV process (0~10 W), gas-liquid mixing existence and type of mixer, air flow rate (1~6 L/min), range of diffuser pore size (16~$160{\mu}m$), water circulation rate (2.8~9.4 L/min) and UV power of improved plasma + UV process (0~10 W) were evaluated. The experimental results showed that RNO degradation of optimum plasma + UV process was 7.36% higher than that of the basic plasma reactor. It was observed that the RNO decomposition of gas-liquid mixing method was higher than that of the plasma + UV process. Performance for RNO degradation with gas-liquid mixing method lie in: gas-liquid mixing type > pump type > basic reactor. RNO degradation of improved reactor which is adapted gas-liquid mixer of diffuser type showed increase of 17.42% removal efficiency. The optimum air flow rate, range of diffuser pore size and water circulation rate for the RNO degradation at improved reactor system were 4 L/min, 40~$100{\mu}m$ and 6.9 L/min, respectively. Synergistic effect of gas-liquid mixing plasma + UV process was found to be insignificant.

AN EXPERIMENT ON THE HEARING OF RAINBOW TROUT IN THE INDOOR AQUARIUM IN BUSAN (부산지방에서 실내수조를 이용한 무지개송어의 사육실험)

  • KIM In-Bae;JO Jae Yoon
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.10 no.4
    • /
    • pp.267-273
    • /
    • 1977
  • Rainbow trout were reared in a small indoor aquarium which was equipped with a simple recirculating biofilter combined with a small amount of inflowing water for 199 days from April 25 to November 10, 1977 in Busan where very hot summer air temperature is encountered, and results obtained were promissing as following; 1. The aquarium has dimensions of $1m\;\times\;1m\;\times\;67cm(depth)$, and a bottom center sedimentation chamber of conical type through which out-flowing water is pushing fecal matter and other detritus outward. The conical sedimentation chamber measures 20 cm depth and 20 cm diameter at its upper mouth and tapers to the bottom end which is connected to 4 cm diameter draining pipe. The draining pipe goes through under the tank and then is elevated on the side. The water depth was maintained at about 40 cm depth by adjusting the heigh of draining pipe. The filter bed contained 16 l of $3\~5\;mm$ zeolite gravels, and water circulation rate was about 1030 l/hr. 2. Continuous inflowing water resulted in a good elimination of waste materials through its outflowing water thus reducing waste loading in the filter. 3. Mean temperature of water in the rearing aquarium containing about 400 l water volume was maintained at around 20 to $22^{\circ}C$ by 0.59 l/min of the inflowing well water which usually maintained the temperature of $17^{\circ}C$ during the hot summer season from the first of July to the first of October when the 10-days-mean air temperature ranged from $20^{\circ}\;to\;27.3^{\circ}C$ $(total\;mean\;24.6^{\circ}C) $ and under this condition the fish continued normal growth. 4. The production per 1 l/min of inflowing water with this simple biofilteration reached 30 hg. 5. The total cost including all feed and power during this experimental rearing period fell well within the economic establishment and if the feed and filteration system are improved the benefit-cost ratio will be much increased.

  • PDF