• Title/Summary/Keyword: Wastewater treatment process

Search Result 1,423, Processing Time 0.031 seconds

Wastewater Treatment Using Ultrafiltration (UF) and Reverse Osmosis (RO) Process (침지형 한외여과 막공법과 역삼투 공법을 이용한 하.폐수처리)

  • Choi, H.J.;Park, Y.J.;Lee, S.M.
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.34 no.10
    • /
    • pp.678-683
    • /
    • 2012
  • One of alternatives to solve the global water shortages is the reuse of wastewater. The aim of this study was to evaluate whether it can be reused for industrial water from wastewater in "A" City with ultrafiltration (UF) and reverse osmosis (RO) process. The results obtained in this study were that the inorganics such as Na, Mg, Cl, Ca, Mn, $PO_4$, $SO_4$, etc. were removed with high treatment efficiency (more than 97%), respectively. However, the removal of $NH_4$-N, TN, $NO_3$-N, BOD was found to be 35.71%, 85.21%, 87.05% and 56%, respectively. The removal efficiency of nutrients was relatively low compared to other metal ions. Despite low nutrients removal, the treated wastewater is recommended to reuse, because the nutrient contents in influent from the secondary wastewater treatment plant were small amount. In addition, all other metrics in the wastewater were found to be lower amount than wastewater reuse criteria. Therefore, the wastewater treated by UF-RO could be sufficient to reuse for industrial waster.

Optimum Dosage of Fenton's Reagent for the Dyeing Wastewater by the Different Conditions of Biological Treatment as the Pre-treatment Process (염색폐수의 생물학적 전처리 조건변화에 의한 최적 펜톤시약 투입량 결정에 관한 연구)

  • Bea Joan-Sam;Lee Sang-Ho
    • Journal of Environmental Science International
    • /
    • v.14 no.7
    • /
    • pp.683-689
    • /
    • 2005
  • The consecutive combination process of a biological process as the pre-treatment and a chemical process as the post-treatment is applied for the dyeing wastewater. The poor efficiency of biological treatment using pure oxygen makes the chemical treatment cost high. It is necessary to improve the efficiency of biological treatment in order to reduce the cost of chemical treatment. The purpose of this paper is to find the minimum dose of chemical reagent to fit the Discharged Water Quality Standards for the different biological treatment effluents. Results revealed that the minimum dosage of Fenton's reagent lead to save the cost of chemical treatment based on the guideline dose in the treatment plant. The possible maximum saving reagents was up to $70\%$ for the effluent of the pilot plant packed with the carrier imbedded microorganisms which were selected from the present treatment plant.

Electrolytic Treatment of Emulsified Oily Wastewater Using DSA Electrode (I) - Batch Treatment - (DSA 전극을 사용한 에멀젼 함유폐수의 전해처리 (I) -회분식 전해처리-)

  • 김인수;송영채
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.2 no.1
    • /
    • pp.67-75
    • /
    • 1996
  • An innovative batch electrolytic system consisted of electrolytic basin, which was equipped with DSA(Dimensionally Stable Anode) type insoluble electrode, Ti/IrO2 anode and H-C metal cathode, and flotation separator was developed for the efficient treatment of shipboard emulsified oily wastewater. The electorod cleance and current density of elecrolytic basin to ensure maximum treatment efficiency of oily wastewater was evaluated as 6 mm, 3 A/dm3, respectively. The electrolytic efficiency of oily wastewater was affected by the operationtemperature, and it means that the temperature controller to ensure the stabiity of the process is required. The conductivity in the electrolytic basin was increased with the percentage of sea water in the oily wastewater, and over 90% of treatment efficiency of oily wastewater could be obtained at 7% of sea water. The oil removal rate was increased according to the increase of the quantity of electricity, and the maximum value of electrilyic rate constant was 288 mgoil/A.min. The information obtained from this study might be used for development of an efficient continuous electrolytic system treating the emulsified oily wastewater.

  • PDF

A Study on Treatment Characteristics and Design of Ultra High Rate Method (Ultra High Rate(UHR) 법의 처리특성 및 설계에 관한 연구)

  • Lee, Jeoung-Su
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.22 no.12
    • /
    • pp.2239-2245
    • /
    • 2000
  • For the treatment of wastewater being discharged in large quantities as in these modern times, qualitative and quantitative concepts should be introduced in consideration of the recycling. In view of a qualitative concept, high rate aeration process is known as the most effective process up to now. However, Lee suggested UHR process showing the superiority over high rate process in treatment rate and quantity. Therefore, this study was performed to investigate the basic sphere of design and treatment quality, such as applicable $BOD_5$-loading and influent wastewater concentration of UHR process, based on Lee's suggestions1). Consequently, this process showed applicable $BOD_5$-loading of $2.2{\sim}7.0kg-BOD_5/kg-MLSS{\cdot}day$, exceeding three times or more of high rate process with maximum applicable loading of $2.25kg-BOD_5/kg-MLSS{\cdot}day$. Meanwhile, with the range of influent wastewater concentration from 200 to 450 mg/L. it showed the treatment rate from 94.7 to 97.3%, it indicated very good condition. In view of quantitative concept of treatment, UHR process is considered an epoch-making treatment process being superior to existing ones.

  • PDF

Electrochemical Treatment of COD and T-N in Wastewater from Flue Gas Desulfurization Process (전해처리법에 의한 탈황폐수 중의 COD 및 총 질소 제거)

  • Cha, Go-Eun;Noh, Da-Ji;Seo, Jeong-Hyeon;Lim, Jun-Heok;Lee, Tae-Yoon;Lee, Jea-Keun
    • Journal of Environmental Science International
    • /
    • v.22 no.9
    • /
    • pp.1073-1078
    • /
    • 2013
  • This paper presents the results of the electrochemical treatment of chemical oxygen demand(COD) and total nitrogen(T-N) compounds in the wastewater generated from flue gas desulfurization process by using a lab-scale electrolyzer. With the increase in the applied current from 0.6 Ah/L to 1.2 Ah/L, the COD removal efficiency rapidly increases from 74.5% to 96%, and the T-N removal efficiency slightly increases from 37.2% to 44.9%. Therefore, it is expected that an electrochemical treatment technique will be able to decrease the amount of chemicals used for reducing the COD and T-N in wastewater of the desulfurization process compared to the conventional chemical treatment technique.

Application of ANN modeling for oily wastewater treatment by hybrid PAC-MF process

  • Abbasi, Mohsen;Rasouli, Yaser;Jowkar, Peyman
    • Membrane and Water Treatment
    • /
    • v.9 no.4
    • /
    • pp.285-292
    • /
    • 2018
  • In the following study, Artificial Neural Network (ANN) is used for prediction of permeate flux decline during oily wastewater treatment by hybrid powdered activated carbon-microfiltration (PAC-MF) process using mullite and mullite-alumina ceramic membranes. Permeate flux is predicted as a function of time and PAC concentration. To optimize the networks performance, different transfer functions and different initial weights and biases have been tested. Totally, more than 850,000 different networks are tested for both membranes. The results showed that 10:6 and 9:20 neural networks work best for mullite and mullite-alumina ceramic membranes in PAC-MF process, respectively. These networks provide low mean squared error and high linearity between target and predicted data (high $R^2$ value). Finally, the results present that ANN provide best results ($R^2$ value equal to 0.99999) for prediction of permeation flux decline during oily wastewater treatment in PAC-MF process by ceramic membranes.

Temperature Prediction for the Wastewater Treatment Process using Heat Transfer Model (열전달 모델을 이용한 폐수처리공정의 온도 예측)

  • Rho, Seung-Baik
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.3
    • /
    • pp.1795-1800
    • /
    • 2014
  • The temperature change in the biologically activated sludge wastewater treatment process was predicted using the heat transfer model. All incoming and outgoing heats in wastewater treatment processes were considered. Incoming heats included the solar radiation heat, the heat from impeller mechanical energy, and the biochemical heat in the aeration process. Outgoing heats comprised the radiation heat from the waste itself, the heat of vaporization and surface aeration, the wind convection heat and the conduction heat between the surface and aerator. All heats were used as an input to the existing empirical heat transfer model. The heat transfer model of wastewater treatment processes is presented also. To test the validity of the heat transfer model, the operating conditions of the actual wastewater treatment plant were used. The temperatures were compared with the model temperatures. Model predictions were consistent within the $1.0^{\circ}C$.

Prospects of Activated Sludge Process in Japan - Its Past, Present, and Future -

  • Fujita, Masanori
    • Journal of Wetlands Research
    • /
    • v.9 no.1
    • /
    • pp.61-67
    • /
    • 2007
  • Our life totally depends on activated sludgeprocess for treatment of wastewater: sewage and industrial wastewater. Activated sludge process was the epoch-making technology in Environmental field. One century has been almost passed since the process was developed in England, and the process is still on the development of improvement. Here, history of activated sludge process, its mechanismsof treating the wastewater, expectations that we had on the process in the past, and future image and possibility on the process were presented. By reviewing the events related to the process, we can foresee potentials for new possibility of activated sludge process.

  • PDF

Study of wastewater-treatment's efficiency using Bacillus subtilis: with an effect of ozonation (Bacillus subtilis를 이용한 폐수처리 효과연구: 오존의 영향을 중심으로)

  • 박영규
    • Journal of environmental and Sanitary engineering
    • /
    • v.17 no.4
    • /
    • pp.29-38
    • /
    • 2002
  • Advanced oxidation of wastewater was studied with a purpose to remove TOC and color by the ozone-assisted Fenton reaction. The optimal conditions were determined by hydrogen peroxide and ozone concentrations. Experimental results indicate that the ozone treatment after Fentons process was found to provide very efficient removal efficiency in the process, avoiding the exclusive ozone treatment. The combined process of ozone in the Fenton oxidation respectively was increased removal efficiences of 10.7% in comparison with exclusive Fenton oxidation. Also, the treatments of ozone after Fenton's oxidation respectively had increased the removal efficiences of 16.%. As a result, the treatment of ozone after Fentons oxidation had the best removal efficiency of approximately 96%. Removal efficiency of color was significantly increased as mush as 26% by the advanced Fenton's oxidation in comparison with exclusive Fenton's oxidation. The removal efficiencies in the biological treatment using Bacillus subtilis after Fenton's oxidation and after Fenton's and ozone's oxidation were increased by 14% and 19% respectively. Although these combined Bacillus subtilis-assisted Fenton's oxidation was determined to be effective method to treat the dyeing wastewater in an economic point of view, the choice of wastewater treatment can be varied depending on water quality.

Analysis of RCSTP Wastewater Characteristics and Installed Treatment Process in Bong-Hwa Gun (봉화군에 도입된 마을하수도 하수 특성 및 처리 공법 분석)

  • Im, Jiyeol;Gil, Kyungik
    • Journal of Wetlands Research
    • /
    • v.15 no.4
    • /
    • pp.453-460
    • /
    • 2013
  • Rural area sewage distribution rate is 40 % less than urban area. Previous research results announced that one of the reason in water resource pollution was caused of low rural area sewage distribution rate. Analysis on operation result of 11 RCSTP in Bong-hwa area which is located at the upper region of An-dong Dam and Im-ha Dam. Based on operation result, an analysis on characteristics of wastewater in Bong-hwa and treatment efficiency of installed treatment process was conducted. The wastewater influent of Bong-hwa contained high organic matter and nutrient than those of urban area. Treatment process showed totally stable treatment efficiency. But, The treatment efficiency for nutrient showed high fluctuation. This result means which is need to operation condition control of nutrient treatment when operating RCSTP.