• Title/Summary/Keyword: Wastewater treatment plants

Search Result 484, Processing Time 0.03 seconds

Spatial distribution of wastewater treatment plants in diverse river basins over the contiguous United States

  • Soohyun Yang;Olaf Buettner;Yuqi Liu;Dietrich Borchardt
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2023.05a
    • /
    • pp.142-142
    • /
    • 2023
  • Humans inevitably and continuously produce wastewater in daily life worldwide. To decrease the degradation of river water bodies and aquatic ecosystem therein, humans have built systems at different scales to collect, drain, and treat household-produced wastewater. Particularly, municipal wastewater treatment plants (WWTPs) with centralized controls have played a key role in reducing loads of nutrients in domestic wastewater for the last few decades. Notwithstanding such contributions, impaired rivers regarding water quality and habitat integrity still exist at the whole river basin scale. It is highly attributable to the absence of dilution capacity of receiving streams and/or the accumulation of the pollutant loads along flow paths. To improve the perspective for individual WWTPs assessment, the first crucial step is to achieve systematic understanding on spatial distribution characteristics of all WWTPs together in a given river basin. By taking the initiative, our former study showed spatial hierarchical distributions of WWTPs in three large urbanized river basins in Germany. In this study, we uncover how municipal WWTPs in the contiguous United States are distributed along river networks in a give river basin. The extended spatial scope allows to deal with wide ranges in geomorphological attributes, hydro-climatic conditions, and socio-economic status. Furthermore, we identify the relation of the findings with multiple factors related to human activities, such as the spatial distribution of human settlements, the degree of economy development, and the fraction of communities served by WWTPs. Generalizable patterns found in this study are expected to contribute to establishing viable management plans for recent water-environmental challenges caused by WWTP-discharges to river water bodies.

  • PDF

Development of GIS System for Agriculture Reuse of Wastewater Resource (GIS를 이용한 농업용수 재이용 활용시스템 개발)

  • Kim, Hae-Do;Lee, Gwang-Ya;Jeong, Gwang-Geun;Lee, Jong-Nam
    • Proceedings of the Korean Society of Agricultural Engineers Conference
    • /
    • 2005.10a
    • /
    • pp.479-484
    • /
    • 2005
  • A GIS-based integrated system for reuse of effluent from wastewater treatment plants was developed in this study. The GIS-supported program classified attribute data which the effluent's quantity and quality and agricultural thematic map data according to the 5 big river basin area. From the database, showing the spatial variation of the water quality of the effluent, thereby proposing proper mitigation strategies over the watershed. Also, this system enables the users who is going to reuse the reclaimed water for their paddies to provide of all the wastewater treatment plant data and agricultural structures and thematic map data.

  • PDF

Nitrogen Removal Performance at Various DO Concentrations in the Bioreactor Packed with Submerged Cilia Media and Granular Sulfur (DO농도 조절에 따른 황 충전 섬모상 반응조의 질소제거 성능 변화)

  • Moon, Jin-Young;Hwang, Yong-Woo
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.20 no.4
    • /
    • pp.519-526
    • /
    • 2006
  • In this study, the major operating factors in SND(simultaneous nitrification and denitrification) using bioreactor packed with submerged cilia media and granular sulfur such as variation of nitrification rate, organic matter removal efficiency and denitrification efficiency in different DO concentration were mainly evaluated. Synthetic wastewater and actual sewage were used as influent wastewater. Experiment with synthetic wastewater as influent wastewater was divided into three phases with the adjustment of DO concentration. As the results, nitrification efficiency and T-N removal efficiency in the Phase 3(DO 1.0~2.0 mg/L) were 99% and 52.3%, which is significantly greater than those in other two phases. Also, loading rate and denitrification efficiency of SCPGS(Submerged Cilia media Packed with Granular Sulfur) were calculated as $0.44kg\;NO_3^--N/m^3-day$ and 50%, respectively. On the other hand, nitrification rate was decreased from 99% to 64% according to the DO concentration with the variation from 3.0~3.5 mg/L(phase1) to 0.4~0.6mg/L(phase2). Although the nitrification rate was decreased in 64% according to the variation of the DO concentration, T-N removal rate was rapidly increased to 49% by increasing of the denitrification efficiency. Experiment with actual sewage as influent wastewater was carried out to evaluate efficiency of SCPGS in real operation condition of full-scale sewage water treatment plant. At the time, T-N removal rate in this experiment and full-scale wastewater treatment plants were given by 43% and 20%, respectively. The above results indicate that SCPGS can be used as an advanced treatment process for economical efficiency considered.

Evaluation of the impact of sewage treatment plants in the Linked treatment through the sewage treatment computer simulation program (하수처리 전산모사 프로그램을 통한 연계처리시 하수처리장 영향 평가)

  • Kim, Sungji;Gil, Kyungik
    • Journal of Wetlands Research
    • /
    • v.22 no.4
    • /
    • pp.321-327
    • /
    • 2020
  • Recently The amount of wastewater and linked wastewater is being increased every year due to industrial development, population growth, and improvement in living standards. Linked wastewater shows the feature-low flow rate and high concentration. Therefore, it has been shown that it has a great impact on the operation of the sewage treatment plant and costs a lot for treating linked wastewater. In this study, a scenario with low increase of water quality when the total amount of the inflow of linked wastewater was entered into individual reactors is obtained. According to the result of modeling, The effluent water quality get the least increment once the water was introduced into the influent and anoxic tank. We generated the various scenarios Based on these results. scenarios are varying according to inflow from linked waste water's distribution ration. As a result of modeling through various scenarios, it was found that the increment of TN and TP were at the least when the inflow of linked water was distributed with ratio between sewage (80%) and oxygen-free tank (20%).

Improvement of Organic Substances Indicators by Linked Ultra Violet-Advanced Oxidation Process After Ozonation for Anaerobic Digested Wastewater (소화탈리액 대상 오존 전처리와 Ultra Violet-Advanced Oxidation Process 연계 처리를 통한 유기물질 지표 개선)

  • Jaiyeop Lee;Jesmin Akter;Ilho Kim
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.37 no.5
    • /
    • pp.253-259
    • /
    • 2023
  • Bioreactors are devices used by sewage treatment plants to process sewage and which produce active sludge, and sediments separated by solid-liquid are treated in anaerobic digestion tanks. In anaerobic digestion tanks, the volume of active sludge deposits is reduced and biogas is produced. After dehydrating the digestive sludge generated after anaerobic digestion, anaerobic digested wastewater, which features a high concentration of organic matters, is generated. In this study, the decomposition of organic carbon and nitrogen was studied by advanced oxidation process. Ozone-microbubble flotation process was used for oxidation pretreatment. During ozonation, the TOC decreased by 11.6%. After ozone treatment, the TOC decreased and the removal rate reached 80.4% as a result of the Ultra Violet-Advanced Oxidation Process (UV-AOP). The results with regard to organic substances before and after treatment differed depending on the organic carbon index, such as CODMn, CODCr, and TOC. Those indexes did not change significantly in ozone treatment, but decreased significantly after the UV-AOP process as the linkage treatment, and were removed by up to 39.1%, 15.2%, and 80.4%, respectively. It was confirmed that biodegradability was improved according to the ratio of CODMn to TOC. As for the nitrogen component, the ammonia nitrogen component showed a level of 3.2×102 mg/L or more, and the content was maintained at 80% even after treatment. Since most of the contaminants are removed from the treated water and its transparency is high, this water can be utilized as a resource that contains high concentrations of nitrogen.

Nutrient Removal in an Advanced Treatment Process using BIO-CLOD (BIO-CLOD를 이용한 고도처리공정에서의 영양염류 제거)

  • Park, Wan-Cheol;Lee, Mi-Ae;Sung, Il-Wha
    • Journal of Environmental Health Sciences
    • /
    • v.40 no.4
    • /
    • pp.322-329
    • /
    • 2014
  • Objectives: The purpose of this study was to investigate the effect of BIO-CLOD on advanced wastewater treatment for enhanced removal efficiency and meeting the stringent discharge water requirements of wastewater treatment plants. Methods: Two experimental apparatuses consisting of anaerobic, anoxic and aeration tanks were operated. One included a BIO-CLOD cultivation tank. Organic and nutrient parameters and removal efficiency were analyzed by pH, BOD, CODcr, SS, T-N and T-P. Results: The average removal efficiencies of BOD, COD and SS from the apparatus with BIO-CLOD tank installation were 95.5%, 88.6% and 92.9%, respectively, and these were higher than the results from the apparatus without BIO-CLOD. The average TP removal efficiency with BIO-CLOD tank marked 56.0%, higher than the 47.3% from the apparatus without one. BIO-CLOD showed a higher performance for TN removal at 49.6%, compared to the result without BIO-CLOD of 34.3% Conclusion: By reaction with BIO-CLOD, ammonia removal was effective in the aeration tank, as was phosphorus release in the anaerobic tank. Phosphorus luxury uptake and nitrification in aeration tank proceeded smoothly. The application of BIO-CLOD can improve the decrease of odor and settleability of activated sludge in a wastewater treatment plant, as well as increase the removal efficiency of organic and nutrient materials in water.

Microbial Risk Assessment using E. coli in UV Disinfected Wastewater Irrigation on Paddy

  • Rhee, Han-Pil;Yoon, Chun-G.;Jung, Kwang-Wook;Son, Jang-Won
    • Environmental Engineering Research
    • /
    • v.14 no.2
    • /
    • pp.120-125
    • /
    • 2009
  • Water stress has become a major concern in agriculture. Korea suffers from limited agricultural water supply, and wastewater reuse has been recommended as an alternative solution.A study was performed to examine the effects of microorganism concentration in the ponded-water of a paddy rice field with reclaimed-water irrigation for evaluating the microbial risk to farmers and neighborhoodchildren.Most epidemiological studies were performed based on an upland field, and they may not directly applicable to paddy fields. Beta-Poisson model was used to estimate the microbial risk of pathogen ingestion. Their risk value increased significantly high level after irrigation and precipitation.It implies that agricultural activities such as plowing, and fertilizing, and precipitation need be practiced a few days after irrigation considering health risks. The results about field application of the microbial risk assessment using E. coli showed difference according to monitoring time and treatment plot. Result of the microbial risk assessment showed that risk values of ground-water and reclaimed secondary waste water irrigation were lower than directly use of wastewater treatment plants' effluent. This paper should be viewed as a first step in the application of quantitative microbial risk assessment of E. coli to wastewater reuse in a paddy rice farming.

Hydrothermal carbonization of sewage sludge for solid recovered fuel and energy recovery (수열탄화를 이용한 하수 슬러지의 고형연료화 및 에너지 회수 효율)

  • Kim, Daegi;Lee, Kwanyong;Park, Kiyoung
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.29 no.1
    • /
    • pp.57-63
    • /
    • 2015
  • Recently, Korea's municipal wastewater treatment plants generated amount of wastewater sludge per day. However, ocean dumping of sewage sludge has been prohibited since 2012 by the London dumping convention and protocol and thus removal or treatment of wastewater sludge from field sites is an important issue on the ground site. The hydrothermal carbonization is one of attractive thermo-chemical method to upgrade sewage sludge to produce solid fuel with benefit method from the use of no chemical catalytic. Hydrothermal carbonization improved that the upgrading fuel properties and increased materials and energy recovery, which is conducted at temperatures ranging from 200 to $350^{\circ}C$ with a reaction time of 30 min. Hydrothermal carbonization increased the heating value though the increase of the carbon and fixed carbon content of solid fuel due to dehydration and decarboxylation reaction. Therefore, after the hydrothermal carbonization, the H/C and O/C ratios decreased because of the chemical conversion. Energy retention efficiency suggest that the optimum temperature of hydrothermal carbonization to produce more energy-rich solid fuel is approximately $200^{\circ}C$.

Treatment of ETA wastewater using GAC as particle electrodes in three-dimensional electrode reactor (활성탄 충진 3D 복극전기분해조를 이용한 ETA 처리)

  • Kim, Ran;Kim, Yu-Jin;Shin, Ja-Won;Kim, Jeong-Joo;Park, Joo-Yang
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.27 no.2
    • /
    • pp.241-249
    • /
    • 2013
  • Ethanolamine (ETA) is widely used for alkalinization of water in steam cycles of nuclear power plants with pressurized water reactor. When ETA contained wastewater was released, it could increase COD and T-N. The treatment of the COD and T-N from ETA wastewater was investigated using the GAC as particle electrodes in three-dimensional electrode reactor (TDE). This study evaluated the effectiveness of GAC as particle electrode using different packing ratio at 300 V. The results showed that GAC-TDE could reduce ETA much more efficiently than ZVI-TDE at the mass ratio of GAC to insulator, 1:2. Additionally, The effect of applied electric potential to COD and T-N reduction was investigated. The results showed the high COD, T-N reduction and current efficiency at the low electric potential. Using the GAC-TDE will provide a better ETA reduction with reducing electrical potential dissipation.

Isolation of Microorganisms and Development of Microbial Augmentation for Treatment of Industrial Wastewater containing Ammonium Nitrogen (암모니아성 질소함유 산업폐수처리를 위한 미생물의 분리 및 복합미생물제제의 개발)

  • Lee, Myoung-Eun;Mun, Seo-Jin;Kwon, Do-Hyuck;Suh, Hyun-Hyo
    • Journal of Life Science
    • /
    • v.30 no.2
    • /
    • pp.129-136
    • /
    • 2020
  • For effective treatment of wastewater containing ammonium nitrogen (NH4-N), AT2, AT9, and AT12 strains, having high total organic carbon (TOC) removal capability, and FN47, possessing excellent ammonia nitrogen removal capability present in the activated sludge in the aeration tank of food wastewater treatment plants, were isolated and identified. The cells of these isolated strains were used for microbial augmentation with FIW-1 in the defatted rice bran as a medium to treat industrial wastewater. The investigation of the cultural characteristics of these isolated strains in the aeration tank showed that the affinities for substrate of the isolated strains were extremely high, of which AT12 (Alcaligenes sp. AT12) was the highest among the isolated strains. Ammonium nitrogen removal efficiency in the food wastewater was 71% in the isolated strain FN47 (Microbacterium sp. FN47) treatment group. When only activated sludge was added in the lab scale pilot using food wastewater during continuous culture experiment, the TOC removal efficiency was 63%. Meanwhile, the removal efficiency of 92% was obtained when the microbial augmentation FIW-1 for wastewater treatment was applied. In addition, the chemical oxygen demand (COD) level from the effluent wherein microbial augmentation FIW-1 was input for the initial three days in the wastewater treatment site experiment showed a treatment rate of about 43%, which was increased to 62% after an elapse of 5 days.