• Title/Summary/Keyword: Wastewater treatment effluent

Search Result 676, Processing Time 0.027 seconds

Evaluation of raw wastewater characteristic and effluent quality in Kashan Wastewater Treatment Plant

  • Dehghani, Rouhullah;Miranzadeh, Mohammad Bagher;Tehrani, Ashraf Mazaheri;Akbari, Hossein;Iranshahi, Leila;Zeraatkar, Abbas
    • Membrane and Water Treatment
    • /
    • v.9 no.4
    • /
    • pp.273-278
    • /
    • 2018
  • Due to the lack of water in arid and semi-arid areas, reuse of wastewater can be a suitable way to compensate for water scarcity. Therefore, in this research, evaluation of the quality of wastewater of Kashan Treatment Plant to use for irrigation was studied. This descriptive cross-sectional study was conducted in 2016. pH, TSS, TDS, turbidity, COD, BOD5, Total Kjeldahl Nitrogen, Total Phosphorus, Total Coliform, fecal coliform, nematode eggs of inlet and outlet of wastewater treatment plant in Kashan were studied. Mean and standard deviation and wastewater quality parameters before and after treatment were tested with SPSS 22 (2014) software. The mean wastewater output of COD, BOD5, TSS, TDS and turbidity were respectively 86.6, 41.2, 11.11, 1095 mgL-1 and 17.5 NTU and the pH was equal to 7.22. Also, the average of Total Kjeldahl Nitrogen and phosphorus were 22.4 and 2.2 mgL-1 respectively. The mean of Total Coliform and fecal coliform were 225, 161 MPN / 100 ml respectively. In addition, no nematode eggs were found in final effluent. The results indicated that the treatment plants had a significant role in the control of microbial and organic pollution load of wastewater. Also, it is concluded that all parameters were in accordance with the standards of Iran's Department of Environment, so, it can be used for unrestricted irrigation.

Management of Nonpoint Sources in Watershed - with reference to Daechong Reservoir in Korea (수계의 비점오염원 관리 - 대청호를 중심으로)

  • Lee, Jong-Ho
    • Journal of Environmental Impact Assessment
    • /
    • v.9 no.3
    • /
    • pp.163-176
    • /
    • 2000
  • The purpose of this study is to analyze the pollutant loads and its distribution, and to suggest the management of nonpoint sources in Daechong Reservoir. The loads from point and nonpoint sources such as population, industry, livestock and land use were calculated per stream or river with topography(1:25,000) of the watershed of Daechong Reservoir. The generating pollutant loads were obtained through multiplication of pollutant sources by generating pollutant quantity per unit pollutant source. The effluent point sources loads is defined as loads from wastewater treatment facilities such as domestic, industrial and livestock wastewater treatment facilities, which were calculated through multiplication of effluent flowrates by water quality constituents concentration. Untreated point sources loads were estimated to be 35 % of total point sources loads. The effluent nonpoint sources pollutant loads were obtained through the multiplication of generating nonpoint sources loads by effluent ratios based on previous studies. The effluent nonpoint sources loads have the ratio of 26.2% of total BOD effluent loadings, 20.1% of total T-N effluent loadings, and 10.5% of total T-P effluent loadings. For the reduction of nonpoint sources loads in Daechong Reservoir, silviculture, artificial wet land, and grassed waterways could be applied. And untreated livestock waste scattered can result in nonpoint loadings, so required the livestock wastes treatment facilities and purifying facilities together with the management of shed, pasture, livestock waste storage site and composting site. Finally, remote sensing and GIS should be applied to the identification of distribution of water quality, watershed, the location and scale of nonpoint sources, effluent process during rainfall, for more detailed analysis of nonpoint sources.

  • PDF

Study on the Effecting Factors for T-N and T-P Removal in Wastewater Treatment Plant using Path Model Approach (경로도형 구축을 통한 하수처리장 질소 및 인 제거 영향인자 파악에 관한 연구)

  • Cho, Yeongdae;Lee, Seul-ah;Kim, Minsoo;Kim, Hyosoo;Choi, Myungwon;Kim, Yejin
    • Journal of Environmental Science International
    • /
    • v.27 no.11
    • /
    • pp.1073-1081
    • /
    • 2018
  • In this study, an operational data set was analysed by establishing a path model to figure out the actual cause-effect relationship of a wastewater treatment plant (WWTP); in particular, for the effluent concentrations of T-N and T-P. To develop the path models, data sets of operational records including effluent concentrations and operational factors were obtained from a field scale WWTP of $680,000m^3$ of treatment capacity. The models showed that the relationship networks with the correlation coefficients between variables for objective expressions indicated the strength of each relationship. The suggested path models were verified according to whether the analyzation results matched known theories well, but sophisticated minute theoric relationships could not be cropped out distinctly. This indicates that only a few paths with strong theoric casual relationships were represented as measured data due to the high non-linearity of the mechanism of the removal process in a biological wastewater treatment.

Current Condition and Prospect of On-Site Domestic Wastewater Treatment Technologies (합병정화조 기술현황 및 전망)

  • 임연택
    • Proceedings of the Membrane Society of Korea Conference
    • /
    • 1998.06a
    • /
    • pp.95-112
    • /
    • 1998
  • Water quality in the public water course has been polluted more seriously than ever before due to the increase of the number and aremount of pollution sources such as domestic and industrial wastewater. For water quality conservation, the Korean government has been trying to construct sewage treatment facilities continually, of which treatment capacity reached to 11,452,400m$^{3}$/day in 1996. Night soil treatment facilites of m nationwide have the treatment capacity of 24,038m$^{3}$/day. But water quality has not been improved because the sewer systems were insufficient and the treatment efficiencies of sewage were not high, enough. For renovation of water quality, miscellaneous domestic wastewater must be treated because 27g BOD/day out of total 40g BOD/person-day come from miscellaneous wastewater, comparing to 13g BOD/day from night soil. However, sole treatment purifier treat only night soil from the flushing toilet. Therefore, it may be desirable to treat the miscellaneous domestic wastewater and the night soil from flushing toilet together by joint treatment purifier system as on-site domestic wastewater treatment technology. In Korea, the joint treatment purifier system, introduced in 1997, have the benefit as follows; i) good water poiluion control effect, ii ) good effect on river water flow, iii) water pollution control with sewage treatment facility, and iv) rapid pollution control effect, etc. In order to achieve a good effect as stated before, i ) strengthening effluent guideline including BOD, nitrogen and phosphorus, ii ) specializing operation to maintain high performance, and iii) supporting its construction and maintenance costs by the governmental level may be necessary: In addition, automation system of joint treatment purifier, technology for its package and compactness, and a new bio-media bio-filter with higher capacity should be further developed in agreement with a more stringent effluent guideline.

  • PDF

Optimum Pre-treatment Method in Constructed Wetlands by Natural Purification Method for Treating Livestock Wastewater (자연정화공법에 의한 인공습지에서 효과적인 축산폐수처리를 위한 최적 전처리방법 구명)

  • Park, Jong-Hwan;Seo, Dong-Cheol;Kim, Ah-Reum;Kim, Sung-Hun;Lee, Seong-Tea;Jeong, Tae-Uk;Choi, Jeong-Ho;Lee, Sang-Won;Cho, Ju-Sik;Kim, Hyun-Ook;Heo, Jong-Soo
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.44 no.3
    • /
    • pp.425-433
    • /
    • 2011
  • In order to obtain optimum pre-treatment methods and improve T-N and T-P removal efficiencies, removal rates of pollutants in small-scale livestock wastewater treatment apparatus with water plant filtration bed or activated sludge tank were investigated. Based on the results from the optimum pre-treatment in small-scale livestock wastewater treatment apparatus, removal efficiencies of pollutants in livestock wastewater treatment plant with water plant filtration and activated sludge beds. The removal rates of COD, SS, T-N, and T-P in effluent were 83, 89, 63 and 87% in small-scale livestock wastewater treatment apparatus with water plant filtration bed, respectively. The removal rates of COD, SS, T-N, and T-P in effluent were 96, 95, 86 and 92% in small-scale livestock wastewater treatment apparatus with activated sludge tank, respectively. For increasing the COD, SS, T-N, and T-P removals in small-scale livestock wastewater treatment apparatus, the water plant filtration and activated sludge beds are recommended. In livestock wastewater treatment plant with water plant filtration ($1^{st}$ treatment) and activated sludge ($2^{nd}$ treatment) beds, the concentrations of COD, SS, T-N, and T-P in effluent were 39, 15, 42 and $1mg\;L^{-1}$, respectively. It was shown that the concentrations of COD, SS, T-N, and T-P met acceptable effluent quality standard for livestock wastewater. Based on the above results, the removal rates of COD, SS, T-N, and T-P in effluent were over 99.8, 99.9, 99.2, and 99.9% in livestock wastewater treatment plant, respectively.

Study for Biological Denitrification of High-Strength Nitrate and Nitrite Industrial Wastewater (고농도 질산 및 아질산성 질소 함유 폐수의 생물학적 탈질에 관한 연구)

  • Lee, Byong Hee
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.19 no.4
    • /
    • pp.446-454
    • /
    • 2005
  • An economic treatment method to remove oxidized nitrogen from wastewater is biological denitrification with organic matters. Several organics can be used, however, methanol is commonly used. When methanol is provided, M:N (Methanol to Nitrogen) ratio is used to define methanol demand for denitrification. In this study, two artificial wastewaters were provided to a biological system to evaluate denitrification performance. Differences of influent total CODcr from effluent soluble CODcr were converted to methanol equivalent and oxidized nitrogen difference between influent and effluent were converted to nitrate equivalent to define M:N ratios. Modes I, II, III, I-1 and IV showed 5.1, 2.7, 3.3, 2.3 and 2.6 of M:N ratios, respectively. Since denitrifying microorganisms had to build a new metabolic system for methanol and influent organics, initial operation mode, Mode I, required more methanol and this resulted in high M:N ratios compared with later operation mode, Mode I-1. Salt in influent did not show inhibitory effects on denitrfication, although this was believed to increase effluent SS and soluble CODcr concentrations in Mode III, I-1 and IV, respectively. The concentrations of effluent soluble $COD_{Mn}$ did not changed much with influent salt.

Fuzzy Control and Optimization for the Wastewater Treatment Process (퍼지제어기를 이용한 하폐수처리공정의 최적화)

  • 천성표;김봉철;김성신
    • Proceedings of the Korean Institute of Intelligent Systems Conference
    • /
    • 2000.11a
    • /
    • pp.452-455
    • /
    • 2000
  • There are increasingly important financial incentives and environmental consideration to improve the effluent quality of wastewater from domestic and industrial users. The activated sludge process is a widely used biological wastewater treatment process. The activated sludge process is complicated due to the many factors such as the variation of influent flowrate and concentration, the complexity of biological reactions and the various operation conditions. Nowadays, not only suspended solids and residual carbon, but also nitrogen and phosphorous concentration of the effluent water must be taken into account for the design and operation of wastewater treatment plants. Also, the effluent quality to be met are more stringent. Therefore, an intelligent control approach is required in order to successful biological nitrogen removal. In this paper, the strategies for dosage of extra carbon in the anoxic zone and DO concentration in the aerobic zone are presented and evaluated through the simulation using the denitrification layout of the IWA simulation benchmark implemented by Matlab$\^$/5.3/Simulink$\^$/3.0. The control strategy to achieve sufficient denitrification rates in an anoxic zone. Methanol is used as an external extra carbon source. The external extra carbon source is required for the nitrogen removal process because nitrogen and organic concentration are fluctuated in the influent flowrate. The dissolved oxygen is calculated by So concentration in the activated sludge model NO.1. The air flowrate of each aerobic reactor is intelligently controlled to achieve the predefined setpoints. Air flowrate is adjusted by the fuzzy logic controller that includes two inputs and one output. The objective function for the optimization procedure is designed to improve effluent quality and reduce the operating cost.

  • PDF

Empirical evaluation for design parameters and operating characteristics of the integrated sedimentation and dissolved air flotation (SeDAF) process at the pilot-scale plant (파일럿 플랜트 규모에서 일체형 침전부상공정 (SeDAF)의 설계인자 및 운전특성에 대한 실증적 평가)

  • Jang, Yeoju;Jung, Jinhong;Lim, Hyunman;Kim, Weonjae
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.35 no.1
    • /
    • pp.1-14
    • /
    • 2021
  • Eutrophication and algal blooms can lead to increase of taste and odor compounds and health problems by cyanobacterial toxins. To cope with these eco-social issues, Ministry of Environment in Korea has been reinforcing the effluent standards of wastewater treatment facilities. As a result, various advanced phosphorus removal processes have been adopted in each wastewater treatment plant nation-widely. However, a lot of existing advanced wastewater treatment processes have been facing the problems of expensive cost in operation and excessive sludge production caused by high dosage of coagulant. In this study, the sedimentation and dissolved air flotation (SeDAF) process integrated with sedimentation and flotation has been developed for enhanced phosphorus removal in wastewater treatment facilities. Design and operating parameters of the SeDAF process with the capacity of 100 ㎥/d were determined, and a demonstration plant has been installed and operated at I wastewater treatment facility (located in Gyeonggi-do) for the verification of field applicability. Several empirical evaluations for the SeDAF process were performed at demonstration-plant scale, and the results showed clearly that T-P and turbidity values of treated water were to satisfy the highest effluent standards below 0.2 mg/L and 2.0 NTU stably for all of operation cases.

Case Study of Cost Effect Analysis for Toxic Compounds to Developing Effluent Limitation Standards : Focus on 1,4-Dichlorobenzene (수질유해물질 배출허용기준 설정에 따른 배출시설 비용영향 분석사례 연구: 1,4-Dichlorobenzene을 중심으로)

  • Kim, Kyeongjin;Kim, Wongi;Heo, Jin;Kim, Kwangin;Kim, Jaehoon;Kim, Sanghun;Yeom, Icktae
    • Journal of Korean Society on Water Environment
    • /
    • v.26 no.4
    • /
    • pp.557-565
    • /
    • 2010
  • Recently, regulations on toxic compounds in aquatic environment have been strengthened in korea due to the increasing public awareness of the water quality. Typically, these regulations include introduction of emerging toxic compounds and stricter effluent limitations for the already regulated compounds. However, too strict regulations may cause excessive burden on the industry. Therefore it is also important to assess the economic impacts when the new effluent limitation guidelines are introduced. The estimation of the additional cost for the wastewater dischargers to meet the new guidelines are based on the selected treatment technology to handle the hazardous substances and the regulatory levels for effluent limitations. To explore the procedures for cost estimation in enforcing new effluent limitations, a case study was performed specially for 1,4-dichlorobenzene. The pollutants of concern are surveyed for different industrial categories and various treatment technologies. For a given pollutant, the general performances of the treatment technologies are surveyed and a representative technology is selected. For a given technology, the capital cost and annual Operation and Maintenance (O&M) cost was calculated. The calculation of baseline costs to operate ordinary treatment technologies is also important. The ratio between the cost for introducing new treatment process and the baseline cost required for conventional technology was used to evaluate the economic impact on the industry. For 1,4-dichlorobenzene, steam stripping and activated carbon processes were selected as the specific treatment technologies. The cost effects to the regulation of the compound were found to be 6.4% and 14.5% increase in capital cost and O&M cost, respectively, at the flow rate over $2,000m^3/d$ for the categories of synthetic resin and other plastics manufacturing industry. For the case of petrochemical basic compounds manufacturing industry, the cost increases were 5.8% and 12.4%, respectively. It was suggested that cost effect analysis to evaluate the economic impacts of new effluent limitations on the industry is crucial to establish more balanced and reasonable effluent limitations to manage the industrial wastewater containing emerging toxic compounds in the wastewater.

Risk assessment of wastewater reuse for Irrigation water (하수처리수의 관개용수 재이용을 위한 위해성 평가)

  • Han, Jung-Yoon;Yoon, Chun-Gyeong;Jung, Kwang-Wook;Jang, Jae-Ho
    • Proceedings of the Korean Society of Agricultural Engineers Conference
    • /
    • 2005.10a
    • /
    • pp.661-666
    • /
    • 2005
  • Wastewater reuse are exposed public health risk by pathogens. Therefore, this study was examined for microbial risk assessment after irrigation as treated wastewater in paddy rice plots. Five treatments were used: biofilter effluent, UV disinfected water, pond treatment, wetland treatment and conventional irrigation water. Risk assessment was calculated based on the beta-Poisson model by concentration of E. coli from 2003 to 2005. Monte-Carlo simulation (n=10,000) was used to estimate the risk characterization of uncertainty. The risk range was from $10^{-5}$ to $10^{-8}$ except biofilter effluent was $10^{-4}$ in June. The USEPA(1992) has recommended that risk of < $10^{-4}$ is acceptable level of safety for potable waters. In 2005, risk value was lower than 2003, 2004 because of the first irrigation for plowing water is lower E. coli concentration used tap water. It is shown that the first irrigation water quality was important for wastewater irrigation in paddy. UV disinfection and natural treatment used pond and wetland were thought to be an effective for wastewater reuse.

  • PDF