• 제목/요약/키워드: Wastewater purification

검색결과 154건 처리시간 0.026초

시설원예 배출 배액의 수질환경 평가 및 정화 부하량 산정 (The Water Quality and Purification Load Assessment of Drain Water of Facility Horticulture Areas)

  • 손진관;최덕규;공민재;윤성욱;박민정;강동현
    • 한국환경과학회지
    • /
    • 제28권12호
    • /
    • pp.1199-1208
    • /
    • 2019
  • Korea's protected horticulture is rapidly increasing in scale due to various advantages such as year-round harvesting, labor savings through automation and shortened culture period, and greater income generation. This study was conducted to investigate the impact of protected horticulture on water quality. The results of this study are expected to provide basic data contributing to improvements towards sustainable agriculture and eco-friendly design of protected horticulture complex. The average T-N and T-P loads from vinyl greenhouses were 286.55± 143.98 mg/L and 59.14±13.77 mg/L, respectively and those from glass greenhouses 380.68 ± 150.41 mg/L and 61.85±20.72 mg/L. The annual discharge of wastewater derived from the monthly discharge from the horticulture greenhouses were estimated at 2597 ton/ha, with the annual phosphorus load amounting to 155.3 kg/ha. The average T-N and T-P loads in the tested greenhouse effluents were in excess of 8.3- and 13.5-fold the standards for the Korean wastewater plant effluent. The waste nutrient solution discharged from a protected horticulture complex can cause water contamination. Therefore, there is a need to conduct follow-up research using a water purification system or a trench method to develop a eco-friendly protected horticulture complex for sustainable agriculture.

고도정수처리에 따른 상수도 공급과정에서의 소독부산물 농도 예측모델 개발 (Development of a Concentration Prediction Model for Disinfection By-product according to Introduce the Advanced Water Treatment Process in Water Supply Network)

  • 서지원;김기범;김기범;구자용
    • 상하수도학회지
    • /
    • 제31권5호
    • /
    • pp.421-430
    • /
    • 2017
  • In this study, a model was developed to predict for Disinfection By-Products (DBPs) generated in water supply networks and consumer premises, before and after the introduction of advanced water purification facilities. Based on two-way ANOVA, which was carried out to statistically verify the water quality difference in the water supply network according to introduce the advanced water treatment process. The water quality before and after advanced water purification was shown to have a statistically significant difference. A multiple regression model was developed to predict the concentration of DBPs in consumer premises before and after the introduction of advanced water purification facilities. The prediction model developed for the concentration of DBPs accurately simulated the actual measurements, as its coefficients of correlation with the actual measurements were all 0.88 or higher. In addition, the prediction for the period not used in the model development to verify the developed model also showed coefficients of correlation with the actual measurements of 0.96 or higher. As the prediction model developed in this study has an advantage in that the variables that compose the model are relatively simple when compared with those of models developed in previous studies, it is considered highly usable for further study and field application. The methodology proposed in this study and the study findings can be used to meet the level of consumer requirement related to DBPs and to analyze and set the service level when establishing a master plan for development of water supply, and a water supply facility asset management plan.

畜産廢水處理시스템의 最適說計要因 導出 (Optimum Design of Animal Wastewater Treatment System)

  • 오인환;박정현;김범석;이상락;맹원재
    • 한국축산시설환경학회지
    • /
    • 제1권1호
    • /
    • pp.47-53
    • /
    • 1995
  • An efficient Treatment of animal wastewater is one of the hot issues for preventing the environmental pollution. It should be established the design parameter in order to purify the animal wastewater. A test is carried on in the pilot plant as a simplified activated sludge process. A vibration sieve separator is deviced to keep the pollution load constant by means of separation of solid matter. The BOD removal efficiency of the vibration sieve showed over 50%. As the test results, the BOD contents of the influent was in average of 3,000 mg/I and that of the effluent 85 mg/I. So, the BOD removal rate showed 97% in average. The SS-contents in the primary chamber was about 3,300 mg/I and that of effluent 92 mg/I. The SS removal efficiency showed 97%. The removal rate of total nitrogen and phosphore were in average of 82% respectively. Carrying out in winter season, it showed relatively good results; The design parameter approved in this test can be applied to the full-time farmers.

  • PDF

사무소건설물(事務所建設物) 중수설비(中水設備)의 적정용량산정(適正容量算定)에 관한 연구(硏究) (A Study on the Optimal Sizing of Wastewater Recycling System for Office Buildings)

  • 정종림;이경회
    • KIEAE Journal
    • /
    • 제2권3호
    • /
    • pp.25-32
    • /
    • 2002
  • The demand for water in a city area has enormously increased due to the concentration of population and improvement of the living quality. In this reason, the water shortage and the pollution by city sewage seem to be inevitable. For saving city water and meeting the demands from the city, the wastewater recycling system can be used, which makes used water reusable by a certain purification process. In Korea, the application of a wastewater recycling system to the buildings has continuously been adopted since its first appearance at the Lotte World Complex in 1989. However, the system has not been in fashion because of its high cost and users' negative attitude against recycled water. A research based on literature review and a case study for a recycling water system was carried out and an estimation and evaluation model was proposed. The results from the present study suggest that the optimal size of the recycling water system should be designed within 30-40% of total water demand in a building. Also, it was found that economic benefits could be expected within the payback period of 5.3 years by securing the operation rate over 70%.

초전도 자기분리에 의한 제지폐수의 정수 (Purification of wastewater from paper factory by superconducting magnetic separator)

  • 하동우;김태형;권준모;손명환;백승규;오상수;하홍수;고락길;김호섭;김영훈;하태욱
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2009년도 하계학술대회 논문집
    • /
    • pp.342-343
    • /
    • 2009
  • Paper factories use a large amount of water and same amount of wastewater is generated. It is important to purity and recycle the wastewater because of water shortages and water pollution. The existing water treatment facilities like precipitation process need large-scale equipment and wide space to purity the wastewater of paper factory. High gradient magnetic separation (HGMS) system has the merits to purity rapidly because of large voids at filter and to occupy small space. In this paper, two types of superconducting magnets were used for HGMS systems. Cryo-cooled Bi-2223 superconducting magnet system with 70 mm room temperature bore and 200 mm of height was prepared. Cryo-cooled Nb-Ti superconducting magnet with 100 mm room temperature bore and 600 mm of height was used for magnetic separator. Magnetic filters were designed by the analysis of magnetic field distribution at superconducting magnets. The various magnetic seeding reactions were investigated to increase the reactivity of coagulation. The effects of magnetic separation of wastewater were investigated as variation of magnetic field strength and flow rate of wastewater.

  • PDF

전도냉각형 고온초전도 자석을 이용한 제지폐수의 자기분리에 의한 정수 (Purification of wastewater from paper factory by cryo-cooled high-$T_c$ superconducting magnetic separator)

  • 하동우;김태형;손명환;권준모;백승규;오상수;고락길;하홍수;김호섭;김영훈;강채훈;하태욱
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2009년도 춘계학술대회 논문집
    • /
    • pp.4-4
    • /
    • 2009
  • Paper factories use a large amount of water and same amount of wastewater is generated. It is important to recycle the wastewater because of water shortages and water pollution. The existing water treatment facilities like precipitation process need large-scale equipment and wide space to purify the wastewater of paper factory. High gradient magnetic separation (HGMS) system has the merits to purify rapidly because of large voids at filter and to occupy small space. In this paper, two types of superconducting magnets were used for HGMS systems. Cryo-cooled Bi-2223 superconducting magnet system with 70 mm room temperature bore and 200 mm of height was prepared. Cryo-cooled Nb-Ti superconducting magnet with 100 mm room temperature bore and 600 mm of height was used for magnetic separator. Magnetic filters were designed by the analysis of magnetic field distribution at superconducting magnets. The various magnetic seeding reactions were investigated to increase the reactivity of coagulation. The effects of magnetic separation of wastewater were investigated as variation of magnetic field strength and flow rate of wastewater.

  • PDF

단위공정별 기초실험을 통한 다기능 융복합부도의 설계·운전인자 도출 (Design and operating parameters of multi-functional floating island determined by basic experiments of unit processes)

  • 임현만;장여주;정진홍;윤영한;박재로;김원재
    • 상하수도학회지
    • /
    • 제32권6호
    • /
    • pp.487-497
    • /
    • 2018
  • Water quality improvement processes for stagnant area consist mainly of technologies applying vegetation and artificial water circulation, and these existing technologies have some limits to handle pollution loads effectively. To improve the purification efficiency, eco-friendly technologies should be developed that can reinforce self-purification functions. In this study, a multi-functional floating island combined with physical chemical biological functions ((1) flotation and oxidization using microbubbles, (2) vegetation purification and (3) bio-filtration with improved adsorption capacity) has been developed and basic experiments were performed to determine the optimal combination conditions for each unit process. It has been shown that it is desirable to operate the microbubble unit process under conditions greater than $3.5kgf/cm^2$. In vegetation purification unit process, Yellow Iris (Iris pseudacorus) was suggested to be suitable considering water quality, landscape improvement and maintenance. When granular red-mud was applied to the bio-filtration unit process, it was found that T-P removal efficiency was good and its value was also stable for various linear velocity conditions. The appropriate thickness of filter media was suggested between 30 and 45 cm. In this study, the optimal design and operating parameters of the multi-functional floating island have been presented based on the results of the basic experiments of each unit process.

Electrochemical treatment of wastewater using boron doped diamond electrode by metal inter layer

  • KIM, Seohan;YOU, Miyoung;SONG, Pungkeun
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2016년도 제50회 동계 정기학술대회 초록집
    • /
    • pp.251-251
    • /
    • 2016
  • For several decades, industrial processes consume a huge amount of raw water for various objects that consequently results in the generation of large amounts of wastewater. Wastewaters are consisting of complex mixture of different inorganic and organic compounds and some of them can be toxic, hazardous and hard to degrade. These effluents are mainly treated by conventional technologies such are aerobic and anaerobic treatment and chemical coagulation. But, these processes are not suitable for eliminating all hazardous chemical compounds form wastewater and generate a large amount of toxic sludge. Therefore, other processes have been studied and applied together with these techniques to enhance purification results. These include photocatalysis, absorption, advanced oxidation processes, and ozonation, but also have their own drawbacks. In recent years, electrochemical techniques have received attention as wastewater treatment process that could be show higher purification results. Among them, boron doped diamond (BDD) attract attention as electrochemical electrode due to good chemical and electrochemical stability, long lifetime and wide potential window that necessary properties for anode electrode. So, there are many researches about high quality BDD on Nb, Ta, W and Si substrates, but, their application in effluents treatment is not suitable due to high cost of metal and low conductivity of Si. To solve these problems, Ti has been candidate as substrate in consideration of cost and property. But there are adhesion issues that must be overcome to apply Ti as BDD substrate. Al, Cu, Ti and Nb thin films were deposited on Ti substrate to improve adhesion between substrate and BDD thin film. In this paper, BDD films were deposited by hot filament chemical vapor deposition (HF-CVD) method. Prior to deposition, cleaning processes were conducted in acetone, ethanol, and isopropyl alcohol (IPA) using sonification machine for 7 min, respectively. And metal layer with the thickness of 200 nm were deposited by DC magnetron sputtering (DCMS). To analyze microstructure X-ray diffraction (XRD, Bruker gads) and field emission scanning electron microscopy (FE-SEM, Hitachi) were used. It is confirmed that metal layer was effective to adhesion property and improved electrode property. Electrochemical measurements were carried out in a three electrode electrochemical cell containing a 0.5 % H2SO4 in deionized water. As a result, it is confirmed that metal inter layer heavily effect on BDD property by improving adhesion property due to suppressing formation of titanium carbide.

  • PDF

Studies on the Production of Artificial Zeolite from Coal Fly Ash and Its Utilization in Agro-Environment

  • Lee, Deog-Bae;Henmi, Teruo;Lee, Kyung-Bo;Kim, Jae-Duk
    • 한국환경농학회지
    • /
    • 제19권5호
    • /
    • pp.401-418
    • /
    • 2000
  • 1. Production of the artificial zeolite from coal ash Coal fly ash is mainly composed of several oxides including $SiO_2$ and $Al_2O_3$ derived from inorganic compounds remained after burning. As minor components, $Fe_2O_3$ and oxides of Mg, Ca, P, Ti (trace) are also contained in the ash. These components are presented as glass form resulting from fusion in the process of the combustion of coal. In other word, coal ash may refer to a kind of aluminosilicate glass that is known to easily change to zeolite-like materials by hydrothermal reaction. Lots of hot seawater is disposing near thermal power plants after cooling turbine generator periodically. Using seawater in the hydrothermal reaction caused to produce low price artificial zeolite by reduction of sodium hydroxide consumption, heating energy and water cost. As coal ash were reacted hydrothermally, peaks of quartz and mullite in the ash were weakened and disappeared, and new Na-Pl peaks were appeared strengthily. Si-O-Si bonding of the bituminous coal ash was changed to Si-O-Al (and $Fe^{3+}$) bonding by the reaction. Therefore the produced Na-Pl type zeolite had high CEC of 276.7 $cmol^+{\cdot}kg^{-1}$ and well developed molecular sieve structure with low concentration of heavy metals. 2. Utilization of the artificial zeolite in agro-environment The artificial zeolite(1g) could remove 123.5 mg of zinc, 164.7 mg copper, 184.4 mg cadmium and 350.6 mg lead in the synthetic wastewater. The removability is higher 2.8 times in zinc, 3.3 times in copper, 4.7 times in cadmium and 4.8 times in lead than natural zeolite and charcoal powder. When the heavy metals were treated at the ratio of 150 $kg{\cdot}ha^{-1}$ to the rice plant, various growth inhibition were observed; brownish discoloration and death of leaf sheath, growth inhibition in culm length, number of panicles and grains, grain ripening and rice yield. But these growth inhibition was greatly alleviated by the application of artificial zeolite, therefore, rice yield increased $1.1{\sim}3.2$ times according to the metal kind. In addition, the concentration of heavy metals in the brown rice also lowered by $27{\sim}75%$. Artificial Granular Zeolites (AGZ) was developed for the purification of wastewater. Canon exchange capacity was 126.8 $cmol^+{\cdot}kg^{-1}$. AGZ had Na-Pl peaks mainly with some minor $C_3S$ peaks in X-ray diffractogram. In addition, AGZs had various pore structure that may be adhere the suspended solid and offer microbiological niche to decompose organic pollutants. AGZ could remove ammonium, orthophosphate and heavy metals simultaneously. Mixing ratio of artificial zeolite in AGZs was related positively with removal efficiency of $NH_4\;^+$ and negatively with that of $PO_4\;^{3-}$. Root growth of rice seedling was inhibited severely in the mine wastewater because of strong acidity and high concentration of heavy metals. As AGZ(1 kg) stayed in the wastewater(100L) for 4days, water quality turned into safely for agricultural usage and rice seedlings grew normally.

  • PDF

코크스폐수에 함유된 $S^{-2}$$SCN^-$이 미생물 활성에 미치는 영향 (Inhibitory Effects of Toxic Materials on Activation of Microorganisms in Coke Plant Wastewater)

  • 김상식;이기세
    • 공업화학
    • /
    • 제24권4호
    • /
    • pp.423-427
    • /
    • 2013
  • 본 연구에서는 코크스공장의 Coke Oven Gas (COG) 정제 과정에서 발생되는 폐수의 특성을 규명하고 폐수를 안정적으로 처리하기 위한 최적 운전조건을 도출하였다. 코크스 제조공장에서 발생되는 폐수 중에는 미생물에 유해한 $S^{-2}$, $SCN^-$이 각각 6.8~11.2 mg/L, 190~320 mg/L로 높은 농도로 함유되어 있다. $S^{-2}$ 이온농도가 10 mg/L 이하인 경우 활성슬러지의 $SV_{30}$값이 280~340 mL로 슬러지 침강성이 양호했지만 $S^{-2}$ 이온농도가 15 mg/L 이상에서는 $SV_{30}$가 560~680 mL로 슬러지 침강성이 악화되었다. 또한 $SCN^-$ 이온의 경우는 $SCN^-$ 이온의 농도가 300 mg/L 이하인 경우 $SV_{30}$값이 245~320 mL로 슬러지 침강성이 양호했지만, $SCN^-$ 이온농도가 400 mg/L 이상에서는 $SV_{30}$ 값이 470~567 mL로 슬러지 침강성이 악화되었다. 따라서 코크스공장 가스 정제공정에서 발생되는 폐수를 효율적이고 안정적으로 처리하고 미생물활성을 양호하게 유지하기 위해서는 폐수처리설비의 유입원수 중 $S^{-2}$$SCN^-$ 이온농도를 각각 15 mg/L, 400 mg/L 이하로 유지해주어야 바람직하다는 것을 알 수 있었다.