• 제목/요약/키워드: Wastewater Recycling System

검색결과 84건 처리시간 0.024초

The investigation of combined ventilation-biofilter systems using recycled treated wastewater on odor reduction efficiency

  • Febrisiantosa, Andi;Choi, Hong L.;Renggaman, Anriansyah;Sudiarto, Sartika I.A.;Lee, Joonhee
    • Asian-Australasian Journal of Animal Sciences
    • /
    • 제33권7호
    • /
    • pp.1209-1216
    • /
    • 2020
  • Objective: The present study aimed to evaluate the performance of odor abatement by using two different ventilation-biofilter systems with recycled stablized swine wastewater. Methods: The performance of odor removal efficiency was evaluated using two different ventilation-biofilter-recycled wastewater arrangements. A recirculating air-flow ventilation system connected to a vertical biofilter (M1) and a plug-flow ventilation system connected to a horizontal biofilter (M2) were installed. Water dripping over the surface of the biofilter was recycled at a flow rate of 0.83 L/h in summer and 0.58 L/h in winter to reduce odorous compounds and particulate matter (PM). The experiments were performed for 64 days with M1 and M2 to investigate how these two ventilation-biofilter systems influenced the reduction of odor compounds in the model houses. Odorous compounds, NH3 and volatile organic compounds (VOCs) were analyzed, and microclimatic variables such as temperature, humidity, and PM were monitored. Results: Ammonia concentration inside M1 was about 41% higher on average than that in M2. PM and total suspended particles (TSPs) inside M1 were about 62.2% and 69.9%, respectively, higher than those in M2. TSPs in the model house were positively correlated with the concentration of NH3 and VOCs. Conclusion: M2 emitted lower concentration of odorous compounds than M1. Moreover, M2 could maintain the optimum temperature condition for a swine house during the cooler season. The plug-flow ventilation-horizontal biofilter system could be used for pig houses to minimize air pollution produced by swine farming activities and maintain optimum microclimate conditions for pigs.

완전혼합형 정석탈인반응조에서 미분말 전로슬래그를 이용한 고농도 인의 회수 (Recovery of High Concentrated Phosphates using Powdered Converter Slag in Completely Mixed Phosphorus Crystallization Reactor)

  • 김응호;임수빈;정호찬;이억재;조진규
    • 한국물환경학회지
    • /
    • 제21권1호
    • /
    • pp.59-65
    • /
    • 2005
  • A phosphate recovery system from artificial wastewater was developed using a completely mixed phosphorus crystallization reactor, in which powdered converter slag was used as a seeding crystal. In preliminary test, the optimal pH range for meta-stable hydroxyapatite crystallization for high phosphorus concentration was observed to be 6.0 to 7.0, which was different from the conventionally known pH range (8.0~9.5) for effective crystallization in relatively low phosphorus concentration less than 5 mg/L. The average phosphorus removal efficiency in a lab-scaled completely mixed crystallization system for artificial wastewater with about 100 mg/L of average $PO_4-P$ concentration was shown to be 60.9% for 40 days of lapsed time. XRD analysis exhibited that crystalline of hydroxyapatite formed on the surface of seed crystal, which was also observed in SEM analysis. In EDS mapping analysis, composition mole ratio (=Ca/P) of the crystalline was found to be 1.78, indicating the crystalline on the surface of seed crystal is likely to be hydroxyapatite. Particle size distribution analysis showed that average size of seed crystal increased from $28{\mu}m$ up to $50{\mu}m$, suggesting that phosphorus recycling from wastewater with high phosphorus concentration can be successfully obtained by using the phosphorus crystallization recovery system.

풍력(風力) 및 습식비중(濕式比重) 선별(選別)에 의한 혼합(混合)폐플라스틱 종말품(終末品)으로부터 PVC 제거(除去)에 관한 연구(硏究) (Removal of PVC from Mixed Plastic Waste by Combination of Air Classification and Centrifugal Process)

  • 최우진;유재명
    • 자원리싸이클링
    • /
    • 제16권5호
    • /
    • pp.71-76
    • /
    • 2007
  • 가정에서 분리 배출된 폐플라스틱은 일반적으로 수선별 등 분리선별 공정을 거친 후 종말품으로 회수되어, 현재 대부분이 매립이나 소각되고 있다. 혼합폐플라스틱 종말품의 경우 2006년 약 175만톤 발생된 것으로 예측되고 있으나, EPR실시 이후로 발생량은 2000년에 비해 2배 이상 크게 증가한 실정이다. 특히, 혼합폐플라스틱 종말품의 경우 PVC 함량(4 wt.% 이하)이 매우 높아 이들의 재활용에 커다란 제약이 되고 있다. 본 연구에서는 혼합폐플라스틱 종말품으로부터 풍력 및 습식 비중선별장치를 이용하여 폴리올리핀계 (PE, PP, PS) 플라스틱을 경량물로 회수하는 선별시스템을 개발하였다. 본 선별시스템은 풍력선별, 자력선별, 1단계 파쇄, 정량공급 및 습식 비중선별 공정으로 구성되어 있으며, 습식 비중선별 공정은 원심분리를 기본으로 혼합-세척-선별 및 탈수가 단일장치내에 집약된 특징이 있다. 또한, 본 연구에서는 연질 플라스틱의 분쇄 효율을 크게 개선한 파쇄기를 개발하였다. 개발된 습식 비중선별장치의 용량은 시간당 0.5 톤으로, 이를 이용하여 회수된 경량물의 PVC 함량은 0.3wt.% 이하이며, 경량 및 중량 회수물의 수분 함량도 각각 10% 이하를 달성하였다.

우리 나라의 환경정책 방향 (Environmental Health Strategies in Korea)

  • 조병극
    • 환경위생공학
    • /
    • 제7권2호
    • /
    • pp.1-10
    • /
    • 1992
  • Since 1960's along with industrialization and urbanization, economic growth has been . achieved, however, at the same time, environmental condition has been seriously deteriorated. . Currently, volume of wastewater has been increasing at annual rate of 7% in sewage and 20% in industrial wastewater. However, the nation's sewage treatment serves only 33% of the municipal wastewater as of 1991. Major portion of air pollutants comes from combustion of oil and coal which comprise 81% of total energy use and emission gases from motor vehicles increasing at an accelerated rate. It is known that Korea generates the highest amount of waste per capta. Nevertheless, it is not sufficient to reduce the volume of waste by means of resources recovery and recycling. Recognizing the importance of global environmental problems such as ozone layer depletion, global warming and acid rain, international society has been making various efforts since the 1972 Stockholm conference. In particular, it is expected that the Rio conference which has adopted the Rio declaration and Agenda 21 will form a crucial turning point of the emerging new world order after the Cold War confrontation. To cope with such issues as domestic pollution and global environmental problems, the fundamental national policy aims at harmonizing "environmental protection and sustainable development". The Ministry of Environment has recently set up a mid-term comprehensive plan which includes annual targets for environmental protection. According to the government plan, gradual improvement of various environmental conditions and specific measures to achieve them is planned in time frame. Additional sewage treatment plants will be constructed in urban areas with the target to treat 65% of the nation's municipal sewage by 1996. Supply of clean fuels such as LNG will also be expanded starting from large cities as a cleaner substitute energy for coal and oil. In parallel with expansion of LNG, emphasis will be placed on installation of stack monitoring system. Due to the relatively limited land, government's basic policy for solid waste treatment is to develop large scale landfill facilities rather than small sized ones. Thirty three regional areas have been designated for the purpose of waste management. For each of these regions, big scale landfill site is going to be developed. To increase the rate of waste recycling the government is planning to reinforce separate collection system and to provide industries with economic incentives. As a part of meeting the changing situation on global environmental problems after UNCED, and accommodation regulatory measures stipulated in the global environmental conventions and protocols, national policy will try to alter industrial and economic structure so as to mitigate the increasing trends of energy consumption, by encouraging energy conservation and efficiency. In this regard, more attention will be given to the policy on the development of the cleaner technology. Ultimately, these policies and programs will contribute greatly to improving the current state of national public health.

  • PDF

신경회로망을 이용한 순환식 돈분폐수 처리시스템의 모니터링

  • 최정혜;손준일;양현숙;정영륜;이민호;고성철
    • 한국생물공학회:학술대회논문집
    • /
    • 한국생물공학회 2000년도 춘계학술발표대회
    • /
    • pp.125-128
    • /
    • 2000
  • 본 연구에서는 순환식 돈분 폐수 처리 시스템에서의 미생물 분포에 따른 폐수 처리 효과를 모델링하기 위해 신경회로망과 PCA를 이용하는 새로운 방법을 제안하였다. PCA 분석 결과를 바탕으로 신경회로망의 최적 입력 조건을 찾고, 실측 데이터를 이용하여, 폐수 처리 시스템의 각 탱크를 별도로 학습함으로써 비교적 적은 수의 데이터에도 불구하고 정확한 모델링 결과를 얻었다. 제안한 시스템은 폐수 처리 시스템의 효과적인모니터링 시스템으로 사용할 수 있으며, 향후 실제 돈분 처리 시스템에서 원하는 기준의 방류수를 얻기 위한 최적의 입력조건 (미생물밀도 등)을 결정하는데 있어서 에뮬레이터로 사용될 수 있을 것으로 기대된다.

  • PDF

혐기-호기 상향류 필터 공정에서 양식배출수의 질산화 및 탈질 연구 (Nitrification and Denitrification of Land-based Fish Farm Wastewater using an Anaerobic-Aerobic Upflow Biological Aerated Filter)

  • 박노백;이현영;김성민;이준상
    • 한국수산과학회지
    • /
    • 제47권5호
    • /
    • pp.622-629
    • /
    • 2014
  • This study induced biological denitrification and nitrification via a biofiltration process with the view of removing nitrogen from land-based fish farm effluent. To achieve this, we operated an aquaculture nitrogen-removal system that includes a denitrification and nitrification reactor [working volume 40 L, flow rate 64.8 L, HRT (hydraulic retention time) 14.8 h, HRT considering recycling of NOx 7.4 h]. In the continuous process, the nitrification rate of ammonium nitrogen exceeded 90% at a steady state and the denitrification efficiency exceeded 80% with recycling to a pre-anoxic reactor. In addition, the pH in the final effluent was lower with a low influent water alkalinity averaging 100 mg/L (as $CaCO_3$). For effective denitrification reactions, carbon must be supplied via particulate organic matter (POM) hydrolysis because of the low C/N (carbon/nitrogen) ratio in the water.

하수슬러지 소각재 중의 인 회수방법의 사례 연구 (Reviews on the Phosphorus Recovery from Incinerated Sewage Sludge Ash)

  • 윤석표
    • 유기물자원화
    • /
    • 제29권1호
    • /
    • pp.5-17
    • /
    • 2021
  • 본 연구는 하수슬러지 소각재에 비교적 높은 함량으로 존재하는 인을 회수하기 위한 국내외 사례를 조사한 문헌연구로서 습식방법 및 열화학적 방법에 의한 인의 회수 및 중금속 제거와 관련한 실험조건과 영향인자 등을 논의하였다. 하수슬러지 소각재의 인 회수 기술 상용화를 위해서는 인 회수과정에서 발생되는 폐수, 잔재물의 처분, 첨가 약품과 에너지 소모의 최소화 등 전체 시스템의 경제성 측면에서 소각시설과 연계한 집적처리공정이 바람직할 것으로 판단된다.

비순환식 양액재배에서 발생하는 폐양액, 폐배지, 폐작물이 환경에 미치는 영향 (Environmental impact of hydroponic nutrient wastewater, used hydroponic growing media, and crop wastes from acyclic hydroponic farming system)

  • 박병록;조홍목;김민상
    • 유기물자원화
    • /
    • 제29권1호
    • /
    • pp.19-27
    • /
    • 2021
  • 양액재배는 기존 비닐하우스 안의 토양재배 방식에서 물이나 배지에 작물을 심고 생육에 필요한 양분(비료)을 녹인 양액을 공급하여 재배하는 방식으로 기존 시설재배 방식에서 영농기술이 발전하여 양액재배는 작물의 생산성을 극대화할 수 있는 큰 장점을 가지고 있다. 본 연구는 폐양액이 다량의 비료 물질을 함유하고 있기에 하천으로 유입되면 인근 하천을 오염시키며, 양액재배에 사용되고 폐기되는 폐배지, 폐작물의 처리에 대한 문제점을 제시하고 있다. 또한, 처리시 처리비용의 발생과 현재 국내 양액재배 농장의 대부분이 비순환식 양액재배 시스템을 사용하여 배출되는 양액의 잔여비료로 인한 환경오염 및 비료의 불필요한 과다 사용 문제점을 지적하는 선행연구를 바탕으로 사전조사와 실험을 진행하였다. 현재 양약재배 비순환식 시스템 재배방식 농장에서 발생하는 폐양액, 폐배지, 폐작물이 농장 주변 환경에 미치는 영향을 수질, 토양분석 결과 수치를 통해 규명하고자 현장자료 연구를 진행하였다. 현장 수질, 토양분석을 위해서 지역별 양액재배 5개 농가의 작형, 양액재배 시스템를 확인하였으며, 강원 C지역 토경재배 3개 농장의 작형, 양액재배 시스템 농장 현장을 방문하여 농장의 시설내·외부 수질, 토양 샘플을 채취하였다. 추가적으로 폐작물 야적지에서 발생되는 침출수 및 토양샘플을 채취하여 수질, 토양분석을 하였다. 연구 결과 비순환식 시스템 재배방식 농장에서 발생되는 폐양액의 평균 total nitrogen(TN) 농도는 402 mg/L 이였고, total phosphate(TP)의 경우 77.4mg/L 이였으며, 이는 환경정책기본법 시행령상 하천의 생활환경 TP기준 993.7배 초과한 수치였다. 또한, 물환경보전법의 산업폐수 배출기준 TN기준 6~19배, TP기준 2~27배 초과한 수치결과를 확인하였다. 폐작물 야적지에서 발생된 침출수의 경우 환경정책기본법 시행령상 하천의 생활환경 COD 기준 11,828배 초과, TP기준 395~2663배 초과한 수치이며, 물환경보전법의 산업폐수 배출기준 TN기준 788배, TP기준 5배 초과한 수치결과를 확인하였다. 비순환식 양액재배에서 발생하는 폐양액, 폐배지, 폐작물이 환경에 미치는 영향에 대한 더 정밀한 연구를 위해 전국 양액재배 농가수(호), 재배면적(ha)를 기준으로 하여 양액재배면적이 넓은 지역 도출해내어야 한다. 이를 통해 넓을 지역의 양액재배 시설 주변 소하천을 중심으로 계절적 요인, 기후 요인, 날씨 요인, 재배면적, 재배지역, 농가 재배특성 등의 다양한 요인을 고려한 수질 및 토양 샘플링 채취와 분석에 관한 추가 연구가 필요할 것으로 판단된다.

Flexo 인쇄폐수의 처리 및 재활용에 관한 연구 (A study on the flexo printing wastewater treatment and recycling)

  • 전용보;허훈;조계민;배우근
    • 청정기술
    • /
    • 제9권3호
    • /
    • pp.107-113
    • /
    • 2003
  • 인쇄 및 출판 산업의 발전으로 인쇄공정에서는 다량의 유독성 폐기물 및 폐수등이 발생한다. 인쇄공정에서 필수적으로 사용되는 각종 환경오염물질에 대한 규제가 강화되고 있기에 환경친화형 청정기술 개발이 필요하며 또한 인쇄업계의 적극적인 환경대응책이 필요한 시점이다. 따라서 본 연구에서는 인쇄폐수에 대한 정밀여과, 한외여과, 역삼투 등의 막분리 시스템의 효용성을 검토하고 공정을 개선할 수 있는 기본 자료를 도출하여 처리수의 재이용 방안을 모색하고 공정의 최적화를 도모하고자 하였다. 그 결과 U/F System의 운전압력은 $2kg/cm^2$이 적당하였으며, U/F처리수는 탁도 3NTU 이하로서 인쇄공정 현장에서 기계세척수로 사용가능할 것으로 판단되었다.

  • PDF

하수처리장 에너지자립화사업에서 혐기성소화공정으로부터 용출되는 용존성질소($NH_3-N$)의 처리 필요성 연구 (The Study of the Need to Remove Soluble nitrogen ($NH_3-N$) Generated from Anaerobic digestor Retrofitted in Municipal Wastewater Treatment Plants)

  • 안세영
    • 유기물자원화
    • /
    • 제22권3호
    • /
    • pp.68-75
    • /
    • 2014
  • 하수슬러지를 혐기성 소화하는 과정에서 용출되는 용존성질소는 다시 수처리시설로 반송되어 질산화 효율이 떨어지는 동절기 법적 방류수 질소 수질기준에 영향을 준다. 컴퓨터 시뮬레이션 소프트웨어(GPS-X)를 이용하여 A하수처리시설을 대상으로 소화조에서 발생하는 용존성질소의 영향을 조사한 결과, 소화조가 있는 처리시설에서의 총 반송수와 1차침전지 유입수 용존성질소 농도는 소화조가 없는 시설에서의 농도보다 각각 214.1 mg/L, 6.2 mg/L 높게 산출되었다. 슬러지 처리시설에서의 반송수를 처리하는 반송수처리시설(부상분리조)을 설치하는 경우 총반송수 용존성질소 농도는 반송수처리시설이 없는 경우보다 6.0 mg/L 높게 나타났으며 1차침전지 유입수 용존성질소 농도를 0.7 mg/L 낮게 산정되었다. 시뮬레이션 결과, 하수슬러지를 혐기성소화하여 에너지자립화율을 향상시키는 사업에서 슬러지 처리시설에서 발생하는 여액과 상등액의 용존성질소($NH_3-N$)를 처리할 수 있는 시설이 필요한 것으로 나타났다.