• 제목/요약/키워드: Waste media

검색결과 326건 처리시간 0.032초

Brevibacterium ammoniagenes에 의한 글루탐산 제조에 관한 연구 (Studies on the Production of L-Glutamic Acid by Brevibacterium ammoniagenes)

  • 유영진;김택영
    • 한국식품과학회지
    • /
    • 제9권1호
    • /
    • pp.1-9
    • /
    • 1977
  • A bacterium strain (K-173-10) which was isolated from waste soil of Korea brewing factory, could be grown on acetate as the sole carbon source and accumulated a considerable amount of L-glutamic acid in the medium. This strain was identified as the new species Brevibacterium ammoniagenes. This study was concerned not only with the culture condition for the production of L-glutamic acid and the cell growth, but also with the effects on concentration of various kind of organic substances, growth factors and penicillin. The results obtained were summarized as follow; 1. It was found that the concentrations of acetate and ammonium ions affected the growth of the bacterium as well as its L-glutamate accumulation. The optimum conditions of the composition of grown media for the growth of the bacterium and its glutamic acid production was found to be 40 g/l of total acetate, $100\;{\mu}g/l$ thiamine, $0.5\;{\mu}g/l$ biotin and $1{\sim}2g/l$ corn steep liquor as the growth factors. 2. Organic acid such as succinic acid, malic acid and ${\alpha}-ketoglutaric$ acid inhibited the cell growth as well as its L-glutamic acid production. 3. The penicillin (20 units/ml) stimulated the production of glutamic acid at appropriate incubation period. 4. It was found that this strain could grow in the presence of urea and ammonium acetate but not in other nitrogen sources.

  • PDF

Application of Subirrigation Using Capillary Wick System to Pot Production

  • Lee, Chi-Won;So, In-Sup;Jeong, Sung-Woo;Huh, Moo-Ryong
    • 농업생명과학연구
    • /
    • 제44권3호
    • /
    • pp.7-14
    • /
    • 2010
  • Alternative subirrigation way, capillary wick system (CWS) was tested to reduce labor cost, waste water, contamination of ground water, and use of fungicide compared to overhead irrigation system (OIS). CWS helped reduce remarkably the working hours for watering from 4 hours in OSI to just 5 minutes. Labor cost was saved 98% in CWS compared to OIS. By the physical characteristics of various growing media, 1 coconut coir+2 perlite (v/v) mixture was selected because it had an ideal distribution of three phase, e.g. 1 solid: 1 liquid: 2 gas phase. Medium mixture containing scoria had so high bulk and particle density to hurt root. In bark-containing medium, the liquid phase and the percent saturation of liquid phase with time elapsed was lower than that of other mixture. It meant that the mixture contained very low level of water. Application of CWS for cyclamen pot production played an important role in reducing the incident of fusarium wilt symptom from 18% in conventional over watering system to 4%. Cyclamen pot irrigated by capillary wick had shorter petiole and more leaves than those by overhead watering. As a result, this system was highly beneficial to get uniform pot products with high quality. It improved water and nutrient solution efficiency relative to conventional overhead irrigation system (OIS).

Evaluation of a moving bed biofilm reactor for simultaneous atrazine, carbon and nutrients removal from aquatic environments: Modeling and optimization

  • Derakhshan, Zahra;Ehrampoush, Mohammad Hassan;Mahvi, Amir Hossein;Dehghani, Mansooreh;Faramarzian, Mohammad;Ghaneian, Mohammad Taghi;Mokhtari, Mehdi;Ebrahimi, Ali Asghar;Fallahzadeh, Hossein
    • Journal of Industrial and Engineering Chemistry
    • /
    • 제67권
    • /
    • pp.219-230
    • /
    • 2018
  • The present study examined a moving bed biofilm reactor (MBBR) bioreactor on a laboratory scale for simultaneous removal of atrazine, organic carbon, and nutrients from wastewater. The maximum removal efficiency of atrazine, chemical oxygen demand (COD), total phosphorus (TP) and total nitrogen (TN) were 83.57%, 90.36%, 90.74% and 87.93 respectively. Increasing salinity up to 40 g/L NaCl in influent flow could inhibit atrazine biodegradation process strongly in the MBBR reactor.Results showed that MBBR is so suitable process for efficiently biodegrading of atrazine and nitrogen removal process was based on the simultaneous nitrification-denitrification (SND) process.

중학생의 환경오염과 학교급식 음식물쓰레기 감량에 대한 태도 (An Attitude about Reduction of Environmental Pollution and School Lunch Leftovers in Middle School Students)

  • 최명윤;한명주
    • 한국식생활문화학회지
    • /
    • 제24권2호
    • /
    • pp.164-171
    • /
    • 2009
  • The objectives of this study were to determine the recognition of food waste, school lunch leftovers and satisfaction toward school lunch in middle school students in Seoul. Four hundred students were surveyed beginning April, 2007. The results are summarized as follows. The primary means in which students learned about environmental pollution were 'video media' (54.7% males, 39.2% females) and 'by teachers' (23.2% males, 33.0% females). The primary effects on food habits after participating in the school lunch program were 'having a balanced diet' (23.3%) in the females, and 'decreased intake of junk food' (24.9%) in the males. The serving sizes for cooked rice, soup, and meat were higher in the females (3.46, 3.46, and 2,91, respectively) than the males (3.18, 3.29, and 2.73, respectively). The primary school lunch leftovers for one week were cooked rice (4.55), meat (4.35), kimchi (3.84), fish (3.60), vegetables (3.38), and soup (3.08). Importance-performance analysis of the school lunch meal indicated that good taste had high importance, but low performance. Nutritional balance, food safety, cleanliness of tableware and supplies, clean uniforms of employees, and cleanliness of the dining area had both high importance and performance.

A Study on the Analysis of Solar Consumer Perception Using Big Data

  • Seungwon Lee
    • International Journal of Advanced Culture Technology
    • /
    • 제12권1호
    • /
    • pp.254-261
    • /
    • 2024
  • Among eco-friendly energy, solar energy is one of the renewable energy sources that is developing in the spotlight in many countries. In line with this, the Korean government and local governments are carrying out projects to provide subsidies for the distribution of household solar power, raising the spread of household solar power and awareness. However, due to the lack of research on consumer perception of household solar power, this study investigated the perception of household solar power from 2015 to 2022 by setting the central word as solar power. As a result, 2016 had the highest number of collections, and when the top 50 words for each year were analyzed, it was confirmed that words related to the installation and maintenance of household solar power dominated. And through CONCOR analysis, a total of four were derived: solar energy recognition, renewable and eco-friendly energy recognition, solar government policies, solar companies, and perceptions of households. Through emotional analysis, it was confirmed that 2021 had the most positive data. As a result, consumer perception of household solar power is positive based on what was mentioned above, but research on how to use negative opinions on waste control and installation and maintenance should be conducted.

산성광산배수로 오염된 지하수 정화용 투수성 반응벽체 반응매질 선정 기초실험 (Experiment of Reactive Media Selection for the Permeable Reactive Barrier Treating Groundwater contaminated by Acid Mine Drainage)

  • 지상우;정영욱
    • 자원환경지질
    • /
    • 제38권3호
    • /
    • pp.237-245
    • /
    • 2005
  • 중금속으로 오염된 산성 지하수의 현장 정화방법으로 투수성반응벽체 기술의 적용 가능성을 평가하기 위하여 반응매질 선정을 위한 실내실험을 수행하였다. 처리대상 오염지하수로 이용한 임기광산 폐석적치장 침출수는 낮은 pH와 높은 금속농도를 갖는다(산도부하량으로 65 kg $CaCO_3$/일, 금속부하량(Fe+Al+Mn)으로 11.6kg/일). 이러한 특성의 오염지하수는 반응매질로 유기탄소 혼합물을 이용하여 황산염환원 반응에 의한 처리가 가능할 것으로 판단된다. 다섯 가지 서로 다른 배합비를 갖는 버섯퇴비, 소나무 바크, 석회석의 혼합 반응매질을 이용한 배치실험 결과를 통해 보면 투수성반응벽체를 적용할 경우 산도부하량은 12.3kg $CaCO_3$/일, 금속부하량은 3.3kg/일로 줄일 수 있다. 대상 지하수의 낮은 pH와 높은 금속부하량을 고려하여 무기탄소를 위주로 한 완충용 반응벽체를 먼저 두고, 이어서 유기탄소 혼합물로 구성되는 반응벽체로 황산염 환원을 유도하는 방법 적용한다면 보다 효과적인 광산배수에 대한 정화를 기대할 수 있을 것이다.

균열 암반 매질에서의 핵종의 붕괴사슬 이동을 위한 연속시간 마코프 프로세스 모델 (Continuous Time Markov Process Model for Nuclide Decay Chain Transport in the Fractured Rock Medium)

  • 이연명;강철형;한필수;박헌휘;이건재
    • Nuclear Engineering and Technology
    • /
    • 제25권4호
    • /
    • pp.539-547
    • /
    • 1993
  • 이전에 제시한 모델 1-3을 다시 확장하여 균열 암반에서의 일차원적 핵종이동에 관한 추계적인 모델을 제시하였다. 이 모델은 처분장 근처의 암반내의 균열을 통한 무한 길이를 갖는 핵종의 붕괴 사슬에 의한 이동을 연속시간 마코프 프로세스를 이용하여 모사한다. 이전의 결정론적 해석해에 의한 모델들이 균일한 다공성매질과 같은 단순성을 요구하고 핵종의 붕괴사슬의 수를 제한하며 균열암반매질내에서의 이동의 경우에는 균열에서 암반으로의 확산등이 고려되지 않거나 그 해의 형태가 복잡하다. 또다른 결정론적인 해를 제시하는 수치모델의 경우에도 해를 얻기 위한 과정이 상당히 복잡하고 정확한 해를 제공하지는 못한다. 이에 반해 이 모델은 매질에서의 핵종의 농도에 관한 기대값과 그 분산으로서 비교적 용이하게 해를 제시한다. 모델을 검증하고 그 효율성가 정착성을 예시하기 위하여 암반으로의 확산이 무시된 단순화된 매질에 대하여 3개의 붕괴 사슬을 갖는 가상의 핵종에 대하여 이동거리와 시간에 대한 농도에 대하여 정확한 해석해와의 비교가 행하여 졌다. 매질을 나눈 구획의 수에 종속 하는 수치분산을 보정하여 계산된 결과에서 이 모델이 해석해와 잘 일치하는 것을 알 수 있었다.

  • PDF

나선형 부유 고분자 여재의 Coalescence 특성을 이용한 비점오염원 저감시설의 유수분리특성 연구 (A Study on the Characteristics of Oil-water Separation in Non-point Source Control Facility by Coalescence Mechanism of Spiral Buoyant Media)

  • 강성원;김석구;김영임;윤상린;김수해;김미경
    • 대한환경공학회지
    • /
    • 제29권8호
    • /
    • pp.950-955
    • /
    • 2007
  • 본 연구에서 개발한 시스템은 기존에 사용되던 유수분리기를 유류가 혼입되어 발생하는 도로, 교량 등의 도시 불투수면 비점 오염저감장치로 업그레이드한 것으로서 유적입자가 coalescence 원리에 의하여 고밀도 고분자 폴리에틸렌 소재를 사용하여 제작된 메디아의 표면과 공간 사이를 타고 이동하면서 합체되어 유적의 크기가 증가한 후 부상하여 제거되는 기전과 SS 성분의 고형물이 침전에 의해 제거되는 원리를 이용한 도시 비점오염저감시설이다. 따라서 본 연구에서는 coalescence 기전을 통해 유수분리가 일어나는 나선형 고분자 여재의 유수분리 특성을 image analysis를 통해 규명하였으며 또한 도로노면 먼지와 폐엔진오일을 이용하여 비점오염원 저감시설에 유입되는 폐수를 모사하여 비점오염원 저감시설의 유수분리 성능을 실험하였다. 연구에 사용된 여재는 부정형의 투명한 나선형 구조를 갖고 있으며, SEM 사진 및 BET 측정 결과 매끄러운 표면 특성을 나타내고 있다. 직접 측정 방법으로 여재의 표면적을 측정한 결과, 여재 1립당 표면적은 1,428 $mm^2$으로 나타났으며, 단위당 중량은 45.3 $kg/m^3$으로 조사되었다. 또한 폐수 내 기름 입자의 액적크기를 현미경으로 촬영하여 이미지 분석을 수행한 결과, 메디아를 통한 폐수내 기름성분의 제거가 coalescence에 의해 일어나고 있음을 증명하였다. 마지막으로 나선형 부유 메디아를 적용한 비점오염저감시설의 성능평가 결과, 유량에 따라서 부유성 고형물은 $86.6\sim95.2%$, $COD_{Cr}$, $87.3\sim95.4%$, n-Hexane 추출물 $71.8\sim94.8%$의 제거효율을 나타내어 본 장치의 처리성능은 기존의 비점오염원 저감시설의 처리대상물질인 유기물과 부유물질 뿐만 아니라 유류의 제거에도 효과적인 것으로 평가되었다.

시설하우스 폐양액 처리를 위한 소형 인공습지의 최적 조합방법, 여재깊이 및 폐양액 부하량 (Optimum Configuration, Filter Media Depth and Wastewater Load of Small-scale Constructed Wetlands for Treating the Hydroponic Waste Solution in Greenhouses)

  • 박우영;서동철;임종서;박성규;조주식;허종수;윤혜숙
    • 한국환경농학회지
    • /
    • 제27권3호
    • /
    • pp.217-224
    • /
    • 2008
  • 시설하우스 폐양액 처리를 위한 소형 폐양액처리장치 개발을 위해 소형 폐양액처리장치를 VF-HF, VF-VF, HF-VF 및 HF-HF 조합형으로 구분하여 조합방법별, 여재깊이별 및 폐양액 부하량별로 각각 최적 조건을 조사하였으며, 개발된 시설하우스 폐양액처리장치의 적용성을 검증하기 위해 상기 최적조건하에서 실제 오이, 파프리카 및 딸기 시설하우스에서 배출되는 폐양액의 수처리효율을 조사하였다. 여재 깊이에 따른 오염물질의 수처리 효율은 BOD, COD, SS, T-N 및 T-P 모두에서 깊이가 깊어짐에 따라 수처리효율이 점점 증가하였으며,여재깊이70 cm에서 모든 조합의 BOD, COD 및 SS의 처리효율은 각각 87, 84 및 82% 이상으로 조합방법에 따라 큰 차이 없이 안정적인 수처리 효율을 보였다. T-N 및 T-P의 경우 HF-HF 및 HF-VF 조합형의 처리효율이 타 조합방법에 비해 약간 높았다. 폐양액 부하량에 따른 BOD, COD, SS, T-N 및 T-P의 처리효율은 $150L\;m^{-2}\;day^{-1}{\approx}300L\;m^{-2}\;day^{-1}>450L\;m^{-2}\;day^{-1}$순으로 폐양액의 부하량이 증가함에 따라 수처리 효율이 점점 감소하였다.모든 폐양액 부하량에서의 오염물질 처리효율은HF-VF 및 HF-HF 조합형이 다른 조합형에 비해 높았으며, 특히 총 질소의 경우 HF-HF 조합형이 가장 높은 처리효율을 보였다. 장치의 최적 여재깊이는 70 cm이상이었고, 최적 폐양액 부하이상의 결과를 미루어 볼 때 시설하우스 소형 폐양액처리량은 $300L\;m^{-2}\;day^{-1}$이하이었으며, 최적 조합방법은HF-HF 조합형이었다.

고온 금속필터 element 표면에 생성된 반점에 대한 평가 (Evaluation of Dark Spots Formated on the High Temperature Metal Filter Elements)

  • 박승철;황태원;문찬국
    • 방사성폐기물학회지
    • /
    • 제6권3호
    • /
    • pp.171-178
    • /
    • 2008
  • 중 저준위 방사성폐기물 유리화 실증시설의 고온필터(HTF)시스템에 금속필터를 도입하여 일련의 성능시험을 수행하였다. 고온필터시스템의 여과재는 총 19개의 필터 element로 구성되는데 필터로서 금속 재질별 특성을 알기 위해 316L, 904L, Inconel 600 등 3종의 element를 혼합하여 필터set를 구성하였다. 매 시험을 종료한 후에는 필터하우징에서 종류별로 필터 element를 꺼내어 육안으로 변화를 관찰하였다. 그 결과 일부 element 표면에서 어두운 색깔의 반점들이 관찰되었으며, 특히 AISI 316L 재질의 element에서 많은 반점들이 발견되었다. 이 반점들이 부식을 의미하는 것인지 확인하기 위해 두 가지 분석을 수행하였다. 첫째 재질별로 1개씩의 element를 절단하여 정상적인 곳과 반점이 있는 곳의 표면 및 단면을 SEM/EDS로 분석하였다. 그 결과 반점은 Na, S, Si 등 무기계 산화물이 집중적으로 침적되어 필터의 미세기공을 막고 있는 현상으로 밝혀졌으며, 이 침적물들은 폐기물 및 유리용탕으로 부터 휘발된 물질로 판단된다. 둘째, 재질별로 필터 element에 대해 ring tensile시험을 수행하였다. 그 결과 반점을 포함한 시험 필터 element의 인장강도 값이 규정값 이상으로 나타나서 필터에 부식이 없는 것으로 확인되었다. 앞서 두 가지 분석결과로 볼 때 시험한 금속필터 표면에 생성된 반점은 부식생성물이라기 보다는 필터 전단으로부터 유입된 무기산화물 필터기공을 막고 있는 현상으로 판단되며, 이 반점이 반점형태로 국부적 지점에만 나타나는 것은 시험 중단시기 필터에 응축된 수분과 관련이 있는 것으로 판단된다. 반점의 생성은 필터의 유효 여과면적이 줄어 결과적으로 필터에 걸리는 압력손실이 커지기 때문에 필터하우징의 상시보온을 통한 응축 방지가 필요할 것으로 판단된다. 아울러, 보다 장시간의 시험을 통해 필터 부식현상에 대한 검증 필요하다고 판단된다.

  • PDF