• Title/Summary/Keyword: Waste incinerators

Search Result 97, Processing Time 0.023 seconds

Comparison of Solid Waste Management System between Beijing and Seoul (베이징과 서울의 폐기물 관리체계 비교연구)

  • Yoo, Kee-Young
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.23 no.3
    • /
    • pp.42-50
    • /
    • 2015
  • Beijing and Seoul are the capital of China and Korea, and political, economic, cultural, and tourist centers as well. Beijing is most likely to follow the footsteps of Seoul in the process of urbanization. The purpose of this study is to find out differences and improvements by comparing the solid waste management system between Beijing and Seoul. China classifies waste into urban waste, industrial waste and hazardous waste, which is the same as Korea did in 1980s. Beijing's policy directions in the waste management is similar to Seoul's in the early 1990s when Seoul strived to construct incinerators and landfill. Beijing's waste management achievements are also similar to Seoul's in that the ratio of recycling and incineration is high and that of landfill is low. Hence, it is expected for the waste management policies and achievement of two cities to resemble more and more. Financial burdens of government, indifference of citizens, and decentralized organizations of waste management might be the issues for Beijing to solve. In particular, to implement the user fee system and to encourage citizens to participate in waste separation discharge appear to be key issues in Beijing. Seoul should take a look at which the Beijing government itself collects waste in station and central area.

Recycling of the Bottom Ash, Sourced from the Local MSW (Municipal Solid Waste) Incinerators, as a Fine Sand for Concrete (소각장(燒却場)에서 발생되는 바닥재의 콘크리트용 잔골재(骨材)로서의 재활용(再活用))

  • Lim, Nam-Woong
    • Resources Recycling
    • /
    • v.16 no.2 s.76
    • /
    • pp.40-47
    • /
    • 2007
  • This paper described recycling of the bottom ash, sourced from the local incinerators as a fine sand for concrete. 10% bottom ash was substituted for the ordinary beach sand in the mortar(on a weigh basis), in conjunction with the pozzolznic diatomite. The specimens were tested according to KS L 5105 and analysed by TCLP(Toxic Chemical Leaching Procedure). The results showed that the hazardous heavy metals in the bottom ash are within the maximum permissible limit of TCLP. The compressive strength of the mortar with 10% bottom ash was highly improved, compared to the control mortar when the pozzolanic diatomite was used. It revealed that the hazardous heavy metals of the mortar with 10% bottom ash were leached within the maximum permissible limit of TCLP. It was concluded that the bottom ash can be reused as a fine sand for concrete when the pozzolanic diatomite was used as a stabilizer.

Property Analysis of Municipal Solid Waste and Estimation of CO2 Emissions from Waste Incinerators (생활폐기물 특성 분석 및 소각시설의 CO2 배출량 평가)

  • Kim, Byung-Soon;Kim, Shin-Do;Kim, Chang-Hwan;Lee, Tae-Jung
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.26 no.6
    • /
    • pp.657-665
    • /
    • 2010
  • Carbon dioxide ($CO_2$) is known to be a major greenhouse gas partially emitted from waste combustion facilities. According to the greenhouse gas emission inventory in Korea, the quantity of the gas emitted from waste sector in 2005 represents approximately 2.5 percent of all domestic greenhouse gas emission. Currently, the emission rate of greenhouse gas from the waste sector is relatively constant partly because of both the reduced waste disposal in landfills and the increased amounts of waste materials for recycling. However, the greenhouse gas emission rate in waste sectors is anticipated to continually increase, mainly due to increased incineration of solid waste. The objective of this study was to analyze the property of Municipal Solid Waste (MSW) and estimate $CO_2$ emissions from domestic MSW incineration facilities. The $CO_2$ emission rates obtained from the facilities were surveyed, along with other two methods, including Tier 2a based on 2006 IPCC Guideline default emission factor and Tier 3 based on facility specific value. The $CO_2$ emission rates were calculated by using $CO_2$ concentrations and gas flows measured from the stacks. Other parameters such as waste composition, dry matter content, carbon content, oxidation coefficient of waste were included for the calculation. The $CO_2$ average emission rate by the Tier 2a was 34,545 ton/y, while Tier 3 was 31,066 ton/y. Based on this study, we conclude that Tier 2a was overestimated by 11.2 percent for the $CO_2$ emission observed by Tier 3. Further study is still needed to determine accurate $CO_2$ emission rates from municipal solid waste incineration facilities and other various combustion facilities by obtaining country-specific emission factor, rather than relying on IPCC default emission factor.

The pilot study on reclamation of incineration ashes of municipal waste in the demonstrative factory

  • Chang Hui-Lan;Liaw Chin-Tson;Leu Ching-Huoh
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 2003.11a
    • /
    • pp.573-580
    • /
    • 2003
  • In Taiwan there are 21 Municipal Solid Waste Incinerators (MSWI) built to treat 80% of the MSW nationwide. Approximately 2,000 tons of incineration ashes of municipal waste contain reaction ash and fly ash (3:1 by weight)will be produced daily, and this may cause a serious waste problem. According to EPA regulations, reaction ash and fly ash produced after incineration should be properly treated. Landfill capacity barely meets the general demands. More efficient actions should be planned and taken. The study found 'reclamation' should be the optimal solution to this problem. Only limited research and previous successful experiences are available among other countries. An incinerator in Northern Taiwan is chosen for this study to make environmental bricks from the reaction ash and fly ash. From the previous tests, the results of strength test were measured. From the previous test results, the fly ash products have not reached the desired strength; hence, reaction ash is chosen for further pilot study. In the experiment, incineration ashes, cement and gravel are mixed in the ratio of 1:1:1(by weight), to ground concretization aggregate and pelletization aggregate, the concrete products made from the aggregates were of the strength of 108 $kgf/cm^2$ and 142 $kgf/cm^2$ individually. For the purpose of making nonstructural walls which met the State Building Standards. In the study, 50 tons of concrete products was yielded from aggregate and environmental bricks. Further observation and supervision are recommended to ascertain the resource recycling and reclamation. EPA has planned to build three 'Recycling Plants' in northern, middle and southern Taiwan to develop efficient techniques to produce concrete products, sub-base course, soundproofing wall, gravel, artificial fishing reefs, tiles, drainage, bricks and etc. This experiment of the demonstrative plant solves the problem of the incineration ashes and opens another opportunity to reclaim them.

  • PDF

A study on the Concentrations of Sulfur compounds using a GC/FPD from Industrial Hazardous Waste Incinerators. (GC/FPD를 이용한 산업폐기물 소각시설의 황 화합물 농도분포특성 연구)

  • 김덕현;유병대;김완중;김선태;박민수;전의찬;박종호
    • Proceedings of the Korea Air Pollution Research Association Conference
    • /
    • 2003.05b
    • /
    • pp.279-280
    • /
    • 2003
  • 환경부에서 발표한 2001년도 사업장 배출시설계 폐기물 발생현황을 보면 소각에 의한 처리량이 1995년도에 5,691톤/일에서 2001년도에 7,875톤/일로 꾸준히 증가하는 추세를 보이고 있다(환경부 2001). 이러한 산업폐기물 소각장에서 발생하는 유해오염물질은 매우 다양하다. 그 중 최근 사회적 이슈로 떠오르는 것이 악취이다. 악취는 황화수소ㆍ메르캅탄류 아민류 등 기타 자극성 있는 기체상 물질이 사람의 후각을 자극하여 불쾌감과 혐오감을 주는 냄새로, 주로 인체 위해성 보다는 정신적ㆍ심리적 피해를 끼치는 감각공해이다(환경부, 2000). (중략)

  • PDF

The Content of Chlorobenzenes and Chlorophenols and Their Isomer in MSWI Fly Ash (소각잔사 중의 클로로벤젠과 클로로페놀의 함량 및 이성체 분포특성)

  • Lee, U-Geun;Sim, Yeong-Suk;Kim, Jin-Beom
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.14 no.3
    • /
    • pp.209-218
    • /
    • 1998
  • Chlorobenzenes (CBs) and chlorophenols (CPs) in fly ashy discharged from several municipal solid waste incinerators (MSWI) were investigated in terms of total content and isomer distribution. The content of CBs and CPs was highest in the fly ash from S incinerator, which were 1040.7ng CB/g-fly ash and 1156.4 ng CP/g-fly ash. According to the experimental results, while all samples contained a large amount of the higher chlorinated CBs, was almost constant regardless of season. The quantities of CBs and CPs depended closely on the chemical composition of MSW. while the isomer distribution of CBs and CPs was constant throughout all the year round.

  • PDF

Estimation of Greenhouse Gas Emission from Solid Waste Incinerators (폐기물 소각시설에서 발생하는 온실가스 배출량 조사)

  • Jang, Young-Gi;Choi, Sang-Jin;Kim, Gwan;Jeon, Eui-Chan;Kim, Deuk-Su
    • Proceedings of the Korea Air Pollution Research Association Conference
    • /
    • 1999.10a
    • /
    • pp.274-276
    • /
    • 1999
  • 지구 기온상승에 영향을 주는 가스는 여러 부문에서 배출되지만, 환경기초시설에서는 소각시설에서 이산화탄소($CO_2$)와 아산화질소($N_2$O), 쓰레기매립지에서 메탄(CH$_4$), 하폐수처리장에서 메탄(CH$_4$)과 아산화질소($N_2$O)가 주로 배출된다. 그러나 우리나라에서는 이 부문의 배출량에 대하여 아직 체계적인 조사가 이루어지지 못하였다. 본 연구의 목적은 우리나라의 폐기물 소각시설에서 발생하는 온실가스 배출량을 산출하는 것이다.(중략)

  • PDF

Operation Scheduling of Industrial Cogeneration System with Each other Generation Mode (서로다른 발전방식으로 운전되는 산업용 열병합발전시스템의 최적운전계획 수립)

  • Jeong, Ji-Hoon;Lee, Jong-Beom;Oh, Sung-Keun
    • Proceedings of the KIEE Conference
    • /
    • 2000.07a
    • /
    • pp.354-356
    • /
    • 2000
  • This paper describes the strategy of a daily optimal operational scheduling on cogeneration systems with each other generation mode. The cogeneration systems consists of three generators. auxiiiary devices which are three auxiliary boilers, two waste boilers and three sludge incinerators. One unit that using the back pressure turbin generates the electrical and the thermal energy. The other two units that using the extraction condensing turbine generate the energy. Auxiliary devices operate to supplement the thermal energy to the thermal load with three units. The cogeneration system has a large capacity which is able to supply enough the thermal energy to the thermal load, however the electric power generated is insufficient to satisfy the electrical load. Therefore the insufficient electric energy is supplemented by buying electrical energy from the utility. Simulation was carried out using optimization toolbox. The result reveals that the proposed modeling and strategy can be effectively applied to cogeneration systems with each other generation mode.

  • PDF

A Study on the Concentrations of Ammonia Compounds Using a UV/vis from Industrial Hazardous Waste Incinerators (UV/vis를 이용한 산업폐기물 소각시설에서 배출되는 Ammonia 화합물의 농도분포특성 연구)

  • 김덕현;유병대;김완중;김선태;박민수;전의찬;홍지형;이석조
    • Proceedings of the Korea Air Pollution Research Association Conference
    • /
    • 2003.11a
    • /
    • pp.398-399
    • /
    • 2003
  • 악취는 황화수소ㆍ메르캅탄류ㆍ아민류 등 기타 자극성 있는 기체상 물질이 사람의 후각을 자극하여 불쾌감과 혐오감을 주는 냄새로, 주로 인체 위해성 보다는 정신적 ·심리적 피해를 끼치는 감각공해이다(김덕현, 2001). 특히 암모니아는 현재 환경부에서 규제하는 8대 악취물질 중 하나로 지정되어있어 이에 대한 많은 연구가 필요한 실정이다 2001년 지정폐기물의 총 발생량은 2,820톤/일 으로 지정폐기물은 매년 증가하고 있는데 이의 상당량을 소각으로 처리하고 있다. 폐기물 처리 소각공정은 크게 쓰레기 반입부, 소각로, 가스냉각설비, 방지시설, 소각재 처리시설 등으로 분류될 수 있다. (중략)

  • PDF

A Rational Operation Scheduling Using Genetic Algorithms on Cogeneration System for Paper Mill (제지공장용 열병합발전시스템에서 유전알고리즘을 이용한 합리적 운전계획 수립에 관한 연구)

  • Choi, Kwang-Beom;Lee, Jong-Beom;Jeong, Ji-Hoon
    • Proceedings of the KIEE Conference
    • /
    • 1999.11b
    • /
    • pp.291-293
    • /
    • 1999
  • This paper proposed the optimal operational scheduling of cogeneration system for paper mill connected with several auxiliary devices. Auxiliary devices that include auxiliary boilers, waste heat boilers and sludge incinerators operate with multi-cogeneration systems. Especially environment element was considered in objective function to solve the environment problem. And GAs(Genetic Algorithms) was applied to optimize and to analyse nonlinear operational property of cogeneration system of paper mill connected with several auxiliary devices. C-language was used to GAs computation. Electricity can be purchased through power system from utility. The proposed operational strategy on cogeneration system for paper mill to increase energy efficiency can be applied to the similar cogeneration system of industrial field.

  • PDF