• 제목/요약/키워드: Waste incinerators

검색결과 97건 처리시간 0.02초

산업폐기물 소각장 근로자에서 요중 PAHs 대사산물과 혈중 aromatic-DNA adducts (Association of PAH-DNA adducts and Urinary PAH metabolites influenced by polymorphisms of xenobiotic metabolism enzymes in industrial wase incinerating workers)

  • 이경호;;최인미;최재욱;조수헌;강대희
    • 한국환경성돌연변이발암원학회지
    • /
    • 제22권4호
    • /
    • pp.303-311
    • /
    • 2002
  • This study evaluated the concentrations of urinary metabolites of polycyclic aromatic hydrocarbons (PAHs) in industrial waste incineration workers. The effect of genetic polymorphisms of xenobiotic metabolism enzymes on urinary concentration of PAH metabolites was assessed. And, aromatic DNA adduct levels were also determined in total white blood cells. Fifty employees were recruited from a company handling industrial wastes located in Ansan, Korea: non-exposed group (n=21), exposed group (n=29). Sixteen ambient PAHs were determined by GC/MSD (NIOSH method) from personal breathing zone samples of nine subjects near incinerators. Urinary 1-hydroxypyrene glucuronide (1-OHPG), a major pyrene metabolite, was assayed by synchronous fluorescence spectroscopy after immunoaffinity purification using monoclonal antibody 8E11 (SFS/IAC). Multiplex PCR was used for genotyping for GSTMI/TI and PCR-RFLP for genotyping of CYP1A1 (MspI and Ile/Val). PAH-DNA adducts in peripheral blood WBC were measured by the nuclease P1-enhanced postlabeling assay. Smoking habit, demographic and occupational information were collected by self-administered questionnaire. The range of total ambient PAH levels were 0.00-7.00 mg/㎥ (mean 3.31). Urinary 1-OHPG levels were significantly higher in workers handling industrial wastes than in those with presumed lower exposure to PAHs (p=0.006, by Kruskal-Wallis test). There was a statistically significant dose-response increase in 1-OHPG levels with the number of cigarettes consumed per day (Pearson correlation coefficient=0.686, p<0.001). Urinary 1-OHPG levels in occupationally exposed smoking workers were highest compared with non-occupationally exposed smokers (p=0.053, by Kruskal-Wallis test). Smoking and GSTMI genotype were significant predictors for log-transformed 1-OHPG by multiple regression analysis (overall model R²=0.565, p<0.001), whereas smoking was the only significant predictor for log-transformed aromatic DNA adducts (overall model R²=0.249, p=0.201). Aromatic DNA adducts was also a significantly correlation between log transferred urinary 1-OHPG levels (pearson's correlation coefficient=0.307, p=0.04). However, the partial correlation coefficient adjusting for Age, Sex, and cigarette consumption was not significant (r=0.154, p=0.169). The significant association exists only in individuals with the GSTMI null genotype (pearsons correlation coefficient=0.516, p=0.010; partial correlation coefficient adjusting for age, sex, and cigarette consumption, r=0.363, p=0.038). Our results suggest that the significant increase in urinary 1-OHPG in the exposed workers is due to higher prevalence of smokers among them, and that the association between urinary PAH metabolites and aromatic DNA adducts in workers of industrial waste handling may be modulated by GSTMI genotype. There results remain to be confirmed in future larger studies.

  • PDF

안산지역 대기 중 다이옥신 및 dl-PCBs의 오염특성 조사 (Concentration and Gas-particle Partition of PCDDs/Fs and dl-PCBs in the Ambient Air of Ansan Area)

  • 허종원;김동기;송일석;이강웅
    • 한국대기환경학회지
    • /
    • 제26권5호
    • /
    • pp.517-532
    • /
    • 2010
  • After establishment of Banwol industrial complex in 1987, Ansan city becomes the largest industrial sector development in Gyeonggi-do, Korea. As the population and industrial activity grow over this region, toxic air pollutants, particularly POPs (Persistent Organic Pollutants) from various emission sources have been major public concerns. Air samples for POPs monitoring were collected at the industrial sites ($A_2$), residential sites ($B_1$, $B_2$), commercial site (C), and rural/remote site (D) of the area of Ansan during 2008 with a prolonged industrial sampling site $A_1$ from 2001 to 2008. All samples were analysed for 2,3,7,8 substituted-polychlorinated dibenzo-p-dioxin and dibenzofurans (PCDD/Fs) and dioxin like polychlorinatd diphenyls (dl-PCBs). In site $A_1$, a steady decline of their concentrations from 2003 to 2008 was observed due to the reinforced emission guideline from waste incinerators. The average concentration of the PCDD/Fs and dl-PCBs ranged between 0.118 pg-TEQ/$m^3$ (rural/remote site D) and 0.532 pg-TEQ/$m^3$ (industrial area $A_2$). These level were generally consistent with previous studies in Gyeonggi-do, while higher than other places. Most of PCDD/Fs congener were partitioned into particle phase, whereas dl-PCBs were partitioned into gas phase. The logarithm of gas-particle partition coefficient $K_P$ of dl-PCBs and PCDD/Fs were well correlated with sub-cooled liquid vapor pressure $P_L$. The slope $m_T$ of log $K_P$ versus log $P_L$ for PCDD/Fs (-1.22) and dl-PCBs (-1.02) in industrial area ($A_2$) were high compared to other residential/commercial area. It suggests that this area was likely influenced by the direct emission source of PCDD/Fs and dl-PCBs. To simulate the partition of PCDD/Fs and dl-PCBs between gas and particle phase, Junge-Pankow model ($P_L$-base) and $K_{oa}$ model were applied. It was found that J-P model was more suitable than the $K_{oa}$ model in this study.

아연제련시설에서의 수은 배출특성 (Emission Characteristics of Mercury in Zn Smelting Process)

  • 박정민;이상보;김형천;송덕종;김민수;김민정;김영희;이상학;김종춘;이석조
    • 한국대기환경학회지
    • /
    • 제26권5호
    • /
    • pp.507-516
    • /
    • 2010
  • Stationary combustion sources such as coal-fired power plants, waste incinerators, industrial manufacturing, etc. are recognized as major sources of mercury emissions. Due to rapid economic growth, zinc production in Korea has increased significantly during the last 30 years. Total zinc production in Korea exceeded 739,000 tons in 2008, and Korea is currently the third largest zinc producing country in the world. Previous studies have revealed that zinc smelting has become one of the largest single sectors of total mercury emissions in the World. However, studies on this sector are very limited, and a large gap in the knowledge regarding emissions from this sector needs to be bridged. In this paper, Hg emission measurements were performed to develop emission factors from zinc smelting process. Stack sampling and analysis were carried out utilizing the Ontario Hydro method and US EPA method 101A. Preliminary data showed that $Hg^0$ concentrations in the flue gas ranged from 4.56 to $9.90\;{\mu}g/m^3$ with an average of $6.40\;{\mu}g/m^3$, Hg(p) concentrations ranged from 0.03 to $0.09\;{\mu}g/m^3$ with an average of $0.04\;{\mu}g/m^3$, and RGM concentrations ranged from 0.23 to $1.17\;{\mu}g/m^3$ with an average of $6.40\;{\mu}g/m^3$. To date, emission factors of 7.5~8.0 g/ton for Europe, North America and Australia, and of 20 or 25 g/ton for Africa, Asia and South America are widely accepted by researchers. In this study, Hg emission factors were estimated using the data measured at the commercial facilities as emissions per ton of zinc product. Emission factors for mercury from zinc smelting pross ranged from 4.32 to 12.96 mg/ton with an average of 8.31 mg/ton. The emission factors that we obtained in this study are relatively low, considering Hg contents in the zinc ores and control technology in use. However, as these values are estimated by limited data of single measurement of each, the emission factor and total emission amount must be updated in future.

이성체 정보를 이용한 토양 중 다이옥신 오염원 해석 (Source Estimation of Dioxin in Soil Using a Congener Pattern)

  • 김종국;김경수;김재식;신선경;정영희;정일록
    • 대한환경공학회지
    • /
    • 제27권3호
    • /
    • pp.316-322
    • /
    • 2005
  • 폐기물 소각시설 주변토양 중 다이옥신 농도를 분석하여 소각시설로부터 거리와 방향에 따른 농도변화를 고찰하고, 시료에 대한 군집분석을 수행하여 발생원이 수용체에 미치는 영향에 대해 검토 하였다. 토양 중 다이옥신 총 농도 및 I-TEQ 농도는 각각 $31.065{\sim}7,257.499\;pg/g\;d.w.$$0.099{\sim}35.191\;pg\;I-TEQ/g\;d.w.$로 나타났다. 조사대상 소각시설 이외의 주변에 소형 소각시설들이 산재해 있어 토양 중 다이옥신 농도와 풍향 및 거리와의 상관성은 약한 것으로 나타났다. 반면 소각시설 배출가스의 영향을 파악하기 위하여 PCDFs와 PCDDs의 비율을 조사한 결과, 소각시설에서 멀어질수록 배출가스에서 높은 비율로 검출되는 PCDFs의 비율이 감소하는 경향을 보였다. 조사대상 소각시설이 주변 토양 중 다이옥신 농도에 미치는 영향권은 500 m 이내인 것으로 판단되었고 먼거리에서 고농도가 검출된 것은 주변에 존재하고 있는 소형 소각시설이나 농약(PCP) 등 다른 오염원에 의한 복합적인 영향을 동시에 받고 있는 것으로 사료되었다. 다이옥신 발생원과 수용체인 토양의 이성체 패턴을 이용한 군집분석 결과, 4개의 그룹으로 나눌 수 있었으며, 각 그룹의 이성체 패턴 비교를 통해 소각시설 배출가스와 농약 등의 발생원이 수용체에 미치는 영향정도에 대해 정성적인 추정이 가능하게 되어 군집 분석이 통계적 수법의 하나로 이용될 수 있을 것으로 사료되었다.

생활쓰레기 유동상(流動床) 소각로(燒却爐) 불연물(不燃物)의 재활용에 관한 연구(硏究) (Study on Recycling of Incombustion Materials from MSWI Fluidized Bed Incinerator Ash)

  • 최우진;박은규;강승균
    • 자원리싸이클링
    • /
    • 제17권4호
    • /
    • pp.3-9
    • /
    • 2008
  • 국내의 경우 2006년 유동상 소각로에서 발생한 소각재는 약 13,952톤에 달하고 있으며, 대부분 자력선별 후 매립처리 되고 있는 실정이다. 본 연구에서는 유동상 소각로에서 발생한 불연물로부터 분리 회수한 무기물 시료와 점토를 일정비율로 배합하여 소결체를 제작하였으며, 물성평가를 통하여 세라믹스(요업)원료로서의 재활용 가능성을 검토하였다. 체가름 및 자력선별 후 회수된 불연물 시료에 대한 중금속 함량 분석결과 Pb 등 일부 중금속의 농도는 여전히 높게 나타났으나 $Cr^{6+}$의 경우는 0.4ppm이하로 낮게 나타났으며, 용출실험결과는 모두 KSLP 기준치 이하로 조사되었다. 최종 회수한 불연물 시료의 XRF 분석결과 금속산화물이 선별공정에서 효율적으로 제거된 것으로 조사되었다. 회수된 불연물 시료를 점토와 일정비율로 배합하여 제조된 소결체의 물성조사 결과 $1,000^{\circ}C$$1,050^{\circ}C$에서 소성한 제품의 경우 불연물을 첨가하면 융제로서의 역할이 가능하여 소성온도를 약 $50^{\circ}C$정도 낮출 수 있다. 또한, 불연물의 첨가량이 증가할수록 소성수축률 및 흡수율이 낮아져서 소결체의 압축강도가 개선되었다.

한국 환경오염 취약지역 주민 건강영향조사 문헌고찰(1997~2021) (Literature Review on Health Effect Surveys of Residents in Environmentally Contaminated Areas in South Korea from 1997 to 2021)

  • 최경화;김수정;장현아;한다희;권호장;조용민
    • 한국환경보건학회지
    • /
    • 제49권3호
    • /
    • pp.134-148
    • /
    • 2023
  • Background: The conducting of health effect surveys (HESs) in environmentally contaminated vulnerable areas (ECVAs) by the central and local governments has been increasing apace with the increase in demand for HESs since the Environmental Health Act was enacted in South Korea in 2008. Objectives: This study aimed to review the HESs of residents in ECVAs conducted in South Korea. Methods: An analysis was performed on 125 reports obtained from the Environment Digital Library, PRISM, and local government websites after selecting from 803 projects obtained as ECVAs from the Korea ON-Line E-Procurement System (1997~2021), National Institute Environment Research (2000~2021), and Korea Environmental Industry and Technology Institute (2009~2021). The reports were classified by background (residents' demand, HES, and more), research design (cross-sectional study, cohort, ecological study, and panel), pollution source (abandoned metal mine (AMM), industrial complex (IC), and more), and assessment method of exposure and health effects. The survey area was converted into administrative district codes for geographical mapping. Results: There were 37, 34, 18, and 10 cases associated with AMM, IC, waste incinerators, and coal-fired power plants, respectively. Most of the studies conducted were cross-sectional studies and ecological studies. The proportion of epidemiological investigations by residents' demand showed an increase from 0.0% to 8.9% for the central government while decreasing from 16.7% to 14.3% for local governments after 2008 compared to before 2008. HESs increased at both the central and local government levels since 2014. For the evaluation method, 365 environmental hazards, 319 health outcomes, and 302 biological markers were investigated, with the most commonly investigated items being metals, cancer, and blood metals. Conclusions: HESs of residents in ECVAs in South Korea have been continuously developed both quantitatively and qualitatively. Future improvements are expected, and systematic review and classification of the HESs is warranted.

Risk perceptions of a population living near a municipal waste incinerator and associated factors with the prevalence of environmental disease

  • Dong Hyun Kim;Chae Kwan Lee;Jeong Ho Kim;Byung Chul Son;Chunhui Suh;Kunhyung Kim;Byeong Jin Ye
    • Annals of Occupational and Environmental Medicine
    • /
    • 제34권
    • /
    • pp.38.1-38.9
    • /
    • 2022
  • Background: This study investigated the risk perceptions, prevalence of environmental diseases (EDs) and associated factors with the prevalence of environmental disease among the population living near an incinerator Methods: Study area were divided into 3 local areas near the incinerator by distance (A, B, C) and control area (D) by distance and geographic isolation. A Questionnaire was conducted with 1,380 in local residents (A, B, C) and 390 in control area (D), gathered information of demographic characteristics, lifestyle, perception of damage by incinerators, experience of EDs (atopic dermatitis, allergic rhinitis, asthma) diagnosed by physician. Analysis of variance, χ2 test, and Kruskal Wallis test was applied to determine the difference by area. Logistic regression analysis was performed to identify factors associated with the prevalence of allergic rhinitis. Results: Residents residing closer to the incinerator had negative perception in most items in questionnaire compared with control. The prevalence of allergic rhinitis was higher as they lived nearby the incinerator (p = 0.008). The associated factors with the prevalence of allergic rhinitis were carpet (odds ratio [OR]: 1.79, p = 0.001), residential area (marginally significant), duration of residence (OR: 1.09, p < 0.001). The perception of environmental pollution around the residential area was inversely associated with the prevalence of allergic rhinitis: perceived as very dissatisfied (OR: 4.21, p = 0.02) compared with very satisfied. Conclusions: As closer to the incinerator, the risk perception tend to negative and prevalence of EDs were increased. Carpet, residential area, duration of residence and perception of environmental air pollution around the residential area were associated with prevalence of allergic rhinitis. These results may be useful for the communication with residents to discuss the environmental problems caused by the incinerator.