• Title/Summary/Keyword: Waste gas

Search Result 1,141, Processing Time 0.026 seconds

Research Investigations at the Municipal (2×35) and Clinical (2×5 MW) Waste Incinerators in Sheffield, UK

  • Swithenbank, J.;Nasserzadeh, V.;Ewan, B.C.R.;Delay, I.;Lawrence, D.;Jones, B.
    • Clean Technology
    • /
    • v.2 no.2
    • /
    • pp.100-125
    • /
    • 1996
  • After recycle of spent materials has been optimised, there remains a proportion of waste which must be dealt with in the most environmentally friendly manner available. For materials such as municipal waste, clinical waste, toxic waste and special wastes such as tyres, incineration is often the most appropriate technology. The study of incineration must take a process system approach covering the following aspects: ${\bullet}$ Collection and blending of waste, ${\bullet}$ The two stage combustion process, ${\bullet}$ Quenching, scrubbing and polishing of the flue gases, ${\bullet}$ Dispersion of the flue gases and disposal of any solid or liquid effluent. The design of furnaces for the burning of a bed of material is being hampered by lack of an accurate mathematical model of the process and some semi-empirical correlations have to be used at present. The prediction of the incinerator gas phase flow is in a more advanced stage of development using computational fluid dynamics (CFD) analysis, although further validation data is still required. Unfortunately, it is not possible to scale down many aspects of waste incineration and tests on full scale incinerators are essencial. Thanks to a close relationship between SUWIC and Sheffield Heat&Power Ltd., an extended research programme has been carried out ar the Bernard Road Incinerator plant in Sheffield. This plant consists of two Municipal(35 MW) and two Clinical (5MW) Waste Incinerators which provide district heating for a large part of city. The heat is distributed as hot water to commercial, domestic ( >5000 dwelling) and industrial buildings through 30km of 14" pipes plus a smaller pipe distribution system. To improve the economics, a 6 MW generator is now being added to the system.

  • PDF

Measurement of the Radiolysis Gases Generated in Several Waste Forms by External Irradiation (${\gamma}$-조사에 의한 방사성폐기물의 방사분해가스 발생량 평가)

  • Kwak, Kyung-Kil;Ryue, Young-Gerl;Kim, Ki-Hong;Je, Whan-Gyeong;Kim, Dong-Ho
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.4 no.4
    • /
    • pp.345-352
    • /
    • 2006
  • The cemented and paraffin wastes form which are incorporated the concentrated wastes, the cemented waste form which is incorporated the spent ion-exchange resins, and the miscellaneous waste(decontamination paper) were irradiated up to $10^{+8}$ rads at $5.43{\times}10^{+5}$ rads/hr with Co-60(72,023.9 Ci) as an external irradiation source. As a result, the radiolysis gases such as $H_2,\;CH_4,\;N_2,\;C_2H_6,\;O_2,\;CO\;and\;CO_2$, were measured in all the wastes. The major gas which was generated in all the wastes was hydrogen($H_2$). The volume of the generated gases showed a difference from $0.029{\sim}0.788\;cm^3.atm/1.1g$ according to the type of wastes, and more was generated in the cemented waste form incorporated a spent ion-exchange resin than in the other wastes. More hydrogen($H_2$) gas was generated in the decontamination paper waste than in the other wastes, and the G($H_2$) value was 0.12.

  • PDF

가스상 TCE 처리를 위한 추출막 생물반응기의 수학적 모사

  • Kim, Ji-Seok;Kim, Gwan-Su;Jang, Deok-Jin
    • 한국생물공학회:학술대회논문집
    • /
    • 2000.04a
    • /
    • pp.370-373
    • /
    • 2000
  • In this work, an extractive membrane bioreactor containing coulture broth of Burkholderia cepacia G4 PR1 constitutively expressing the TCE-degrading enzyme, tolune-ortho-monooxygenase(TOM), was used for the degradation of TCE. The membrane bioreactor operates by seperating the TCE-containing waste gas from the aerated biomedium, by which the air-stripping of TCE without degradation was overcome that could occur in conventional aerobic biological treatments of TCE-contaminated waste gases. This was achieved by a silicone rubber membrane which was coiled around a perspex draft tube. TCE from the gas phase diffuses across the silicone rubber membrane into microbial culture broth that was continuously fed from a separate aerobic CSTR. Therefore, TCE degradation occured without the TCE being directly exposed to the aerating gas stream. Of the TCE supplied to the membrane bioreactor, 72.6% was biodegraded during the operation of this system. To construct a mathematical model for this system, parameters describing microbial growth kinetics on TCE were determined using a CSTR bioreactor. Else parameters used for numerical simulation were determined from either indepedent experiments or values reported in the literature. The model was compared with the experimental data, and there was a good agreement between the predicted and the measured TCE concentrations in the system. To achieve a higher treatment efficiency, various operating conditions were simulated as well.

  • PDF

The Improvement of Bio-gas Production through the Change of Sludge-Recycle Ratio with Two-Stage Anaerobic Digestion (2단 혐기성소화조의 슬러지 반송율 변화를 통한 Bio-Gas 생산 증대)

  • Kwon, Kooho;Lee, Taewoo;Jung, Yongjun;Min, Kyungsok
    • Journal of Environmental Science International
    • /
    • v.23 no.6
    • /
    • pp.1061-1066
    • /
    • 2014
  • This study has cross checked the change of internal sludge-recycle in Anaerobic-Digestion, and researched about not only the improvement of Bio-gas production from the digested sludge but also the efficient method of sludge minimization. Ultimate object of the study is to reduce the amount of sludge by the improved efficiency of contact with the organic-matter and the microbes in Anaerobic-Digestion. The sludge-recycle fluidized sludge layer and raised the activity of the sludge, the optimal sludge-recycle ratio, VS and COD removal ratio were 1,000%, 28.2% and 27.7%, respectively. Through these results of this study, it may be of use to treat waste sludge by the sludge-recycle ratio in terms of minimization and circulation of resources.

Thermodynamic Performance Characteristics of Organic Rankine Cycle (ORC) using LNG Cold Energy (LNG 냉열을 이용하는 유기랭킨사이클(ORC)의 열역학적 성능 특성)

  • Kim, Kyoung Hoon;Ha, Jong Man;Kim, Kyung Chun
    • Journal of the Korean Institute of Gas
    • /
    • v.18 no.2
    • /
    • pp.41-47
    • /
    • 2014
  • In this work a thermodynamic performance analysis is carried out for a combined cycle consisted of an organic Rankine cycle (ORC) and a LNG cycle. The combined system uses a low grade waste heat in the form of sensible energy and the LNG cold energy is used for power generation as well as for heat sink. The effects of the key parameters of th system such as turbine inlet pressure, condensation temperature and source temperature on the characteristics of system are throughly investigated. The simulation results show that the thermodynamic performance of the combined system can be significantly improved compared to the normal ORC which is not using the LNG cold energy.

A Study on Greenhouse Gas Emissions Characteristics of Local Government for the Achievement of the National Reduction Goal (국가 온실가스 감축목표 달성을 위한 지자체 온실가스 배출특성 연구)

  • Park, Ji Hui;Kim, Hyung Suk;Song, Kwon Bum;Yi, Sung Ju
    • Journal of Climate Change Research
    • /
    • v.8 no.3
    • /
    • pp.247-255
    • /
    • 2017
  • In this study, GHG inventory on 17 local government between 2005 and 2014 is build up using 'GHG emission estimation guideline (2016. 2) for local government' developed and distributed by KECO. This covers all the sectors should be included in national GHG inventory, which are energy, industrial process, agriculture, AFOLU, and waste. In addition, six GHGs, carbon dioxide, metane, nitrous oxide, hydrofluorocarbons, perfluorocarbons, sulphur hexafluoride declared in Kyoto protocol are estimated to reflect utmost precision. Indirect esissions, such as electricity, heat and waste generation are separately estimated as well as direct emissions to help local government to establish substantial and implementable reduction measures of GHGs.

A Study on the Efficiency of Fuel Cells for Marine Generators (선박 발전기용 연료전지 시스템의 효율에 관한 연구)

  • Lee, Jung-Hee;Kwak, Jae-Seob;Kim, Kwang-Heui
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.17 no.5
    • /
    • pp.52-57
    • /
    • 2018
  • Most current ships have adopted on-board diesel generators to produce electricity, but the overall efficiency of equipment is down to about 50% due to thermal losses from operations such as exhaust gas, jacket water cooler, scavenge air cooler, etc. Recently, fuel cells have been highlighted as a promising technology to reduce the effect on the environment and have a higher efficiency. Therefore, this paper suggested a solid oxide fuel cell (SOFC)-gas turbine (GT) using waste heat from a SOFC and SOFC-GT-steam turbine (ST) with Rankine cycle. To compare both configurations, the fuel flow rate, current density, cell voltage, electrical power, and overall efficiency were evaluated at different operating loads. The overall efficiency of both SOFC hybrid systems was higher than the conventional system.

Development of power system and degradation technology using arc plasma for the degradation of non degradable waste water (플라즈마를 이용한 액상 폐기물 처리 전원장치 개발 및 분해 기술 개발)

  • Han, Chul-Woo;Kim, June-Sung;Park, Sang-Hoon;Hwang, Lee-Ho;Rhee, Byong-Ho;Kang, Duk-Won;Kim, Jin-Kil
    • Proceedings of the KIEE Conference
    • /
    • 2004.07c
    • /
    • pp.1900-1902
    • /
    • 2004
  • The degradation systems of non degradable waste water consist of the arc plasma torch, power supply, a feeder of liquid waste and reactors. Output of stable plasma torch, suitable air flux, microscopic atomizing state of waste water and long reaction section must be to degrade waste water more efficiently. In this paper, we are designed the stable power system, the microscopic atomizing state of waste water and the efficient reactors to satisfy various conditions. Non degradable wast water used in this work was $Na_2$EDTA of 1.0 mol. The concentration of $CO_2$ and EDTA was analyzed using GC (Gas Chromatography) and HPLC (High Performance Liquid Chromatography). In the result show that $CO_2$ concentration was about 96% and EDTA was degraded approximately 96%.

  • PDF