• Title/Summary/Keyword: Waste Combustion

Search Result 348, Processing Time 0.022 seconds

A study on the bed combustion of solid waste (고형 폐기물층 연소에 관한 연구)

  • Sin, Dong-Hun;Choe, Sang-Min
    • 한국연소학회:학술대회논문집
    • /
    • 1998.10a
    • /
    • pp.1-8
    • /
    • 1998
  • Waste combustion above a grate is the core process of incineration systems, stability of which should be guaranteed for emission minimization. However, complicated reactions and heat and mass transfer phenomena make understanding the process difficult. One dimensional bed combustor with a numerical combustion model is utilized to investigate the combustion process of the bed, using cubic wood particles as a simulated fuel. Bed combustion behavior is characterized with apparent flame propagation speed, which has close relationship with air supply rate and chemical and physical characteristics of the fuel. Base on the availability of oxygen, two distinct reaction zone is identified; the oxygen-limited and the reaction-limited zone leading to the extinction by excessive convection cooling. The numerical modeling shows good agreement with the experimental results. The transient bed combustion behavior of local temperature and oxygen consumption rate is adequately reproduced. The numerical model is extended to model the waste bed combustion of a commercial incineration plant, which shows meaningful results as well.

  • PDF

Physical and Chemical Characteristics of Waste Automotive Catalysts (자동차 폐촉매의 물리 화학적 특성)

  • Seo, Seong-Gyu;Moon, Joung-Sun
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.22 no.5
    • /
    • pp.819-825
    • /
    • 2000
  • The physico-chemical characteristics and the combustion activities of a waste automotive catalyst were carried out in this study. The physico-chemical characteristics of waste automotive catalyst was examined by EA(Elemental analysis), ICP-AES (Inductively coupled plasma-atomic emission spectrophotometer), and XRD(X-ray diffraction) analysis. Carbon deposit amount was higher in front brick than rear brick of catalyst, and increased with mileage. The content of Pt. Pd and Rh in waste automotive catalyst was different from the car manufacturing company. The combustion activities of waste automotive catalyst were investigated for acetaldehyde as a model VOC in a fixed bed reactor at atmospheric pressure. The catalytic activity of rear brick for acetaldehyde combustion was better than front brick of waste automotive catalyst. The catalytic activity of waste automotive catalyst for acetaldehyde combustion decreased with mileage. The linear relationship between catalytic activity and mileage was negative and has a very excellent correlation. Finally, the waste automotive catalyst has a good catalytic activity for acetaldehyde combustion. and can be used to control of small emission source.

  • PDF

A Study on Combustion Characteristics and Evaluating of RDFs(Refused Derived Fuels) from Mixture of Petrochemical Wastewater Sludge and Organic Matters (석유화학폐수슬러지와 유기성 폐기물 혼합에 의한 연소특성 및 고형연료 폐기물화 재활용에 관한 연구)

  • Han, Young-Rip;Choi, Young-Ik
    • Journal of Environmental Science International
    • /
    • v.24 no.2
    • /
    • pp.237-244
    • /
    • 2015
  • This objectives of research are to figure out combustion characteristics with increasing temperature with petrochemical sludge by adding wasted organic matters which are waste electric wire, anthracite coal and sawdust, and to exam heating value and ignition temperature for using refused derived fuels(RDFs). After analyzing TGA/DTG, petrochemical sludge shows a rapid weight reduction by vaporing of inner moisture after $170^{\circ}C$. Gross weight reduction rate, ignition temperature and combustion rates represent 68.6%, $221.9^{\circ}C$ and 54.1%, respectively. In order to assess the validity of the RDFs, the petrochemical sludge by adding wasted organic matters which are waste electric wire, anthracite coal and waste sawdust. The materials are mixed with 7:3(petrochemical sludge : organic matters)(wt%), and it analyzes after below 10% of moisture content. The ignition temperatures and combustion rates of the waste electric wire, anthracite coal and waste sawdust are $410.6^{\circ}C$, $596.1^{\circ}C$ and $284.1^{\circ}C$, and 85.6%, 30.7% and 88.8% respectively. In heating values, petrochemical sludge is 3,600 kcal/kg. And the heating values of mixed sludge (adding 30% of the waste electric wire, anthracite coal and waste sawdust) each increase up to 4,600 kcal/kg, 4,100 kcal/kg and 4,300 kcal/kg. It improves the ignition temperatures and combustion rates by mixing petrochemical sludge and organic matters. It is considered that the production of RDFs is sufficiently possible by using of petrochemical sludge by mixing wasted organic matters.

Radiation Heat Flux and Combustion Characteristics of Inverse Diffusion Flame Burner Using Synthesis Gas, Part 1 : Air-Fuel Combustion (합성가스를 이용한 역확산버너의 연소 및 복사열전달 특성, Part 1 : 공기-연료 연소)

  • Lee, Pil-Hyong;Park, Chang-Soo;Lee, Jae-Young;Park, Bong-Il;Hwang, Sang-Soon;Lee, Sung-Ho;Anh, Yong-Soo
    • Journal of the Korean Society of Combustion
    • /
    • v.14 no.4
    • /
    • pp.33-40
    • /
    • 2009
  • Waste Thermal Pyrolysis Melting process was proposed and has been studied in order to prevent air pollution by dioxin and fly ash generated from combustion process for disposal of waste. In this study, applicability as the fuel of diffusion burner of synthesis gas formed from Waste Thermal Pyrolysis process was addressed. Results showed that there is no big difference in the flame shape between MNDF and SNDF, and lift off was detected in MIDF but flame is more stable in SIDF which contains hydrogen with high combustion velocity as flow rate in first nozzle is increased. And radiation heat flux in inverse diffusion flame of synthesis gas was found to be more by 1.5 times than that in inverse diffusion flame of methane because of higher mole fraction of $CO_2$ with high emissivity in product gas.

  • PDF

An Experimental Study on the Bed Combustion Phenomena in MSW(Municipal Solid Waste) Incinerator (폐기물 소각로 베드에서의 연소현상 관찰을 위한 실험적 연구)

  • Min, Jee Hyun;Shin, Donghoon;Choi, Sangmin
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.23 no.2
    • /
    • pp.159-165
    • /
    • 1999
  • Experimental studies have been performed to observe the basic phenomena of waste bed combustion in MSW incinerator. A reduced scale apparatus was utilized to simulate the combustion behavior in real plant with 1-dimensional transient behavior at the experimental setup, which uses wet cubic wood with ash content as simulated waste. LHV (lower heating value) of solid fuel, fuel particle size and flow rate of combustion air were taken as important parameters of the bed combustion. For the quantitative analysis, FPR (flame propagation rate), TBT (total burn-out time) and PBT (particle burn-out time) was defined. LHV represent the capability of heat release of the fuel, so that a higher LHV results in faster reaction rate of the fuel bed, which is shown by higher FPR. Fuel particle size is related with surface area per unit mass as well as heat and mass transfer coefficient. As the particle size increases the FPR decreases owing to decreasing specific surface area. Air injection supplies oxygen to the reaction zone. However oversupply of combustion air increases convection cooling of the bed and possibly extinguishes the flame.

Combustion Characteristics of Waste Sewage Sludge using Oxy-fuel Circulating Fluidized Bed (슬러지 순산소 유동층 연소특성)

  • Jang, Ha-Na;Sung, Jin-Ho;Choi, Hang Seok;Seo, Yong-Chil
    • Korean Chemical Engineering Research
    • /
    • v.55 no.6
    • /
    • pp.846-853
    • /
    • 2017
  • Cold bed and $30kW_{th}$ pilot bed tests using circulating fluidized bed (CFB) were conducted to apply oxy-fuel technology for waste sludge combustion as a carbon capture and storage technology. In cold bed test, the minimum fluidization velocity ($u_{mf}$) and superficial velocity for fast fluidization was determined as 0.120 m/s and 2.5 m/s, respectively. In the pilot test, air and oxy-fuel combustion experiments for waste sludge were conducted using CFB unit. The flue-gas temperature in 21~25% oxy-fuel combustion was higher than that of air and up to 30% oxy-fuel combustion. In addition, the concentration of carbon dioxide was more than 80% with the oxygen injection range from 21% to 25% in oxy-fuel CFB waste sludge combustion.

A Study on the Combustion Characteristics of Food Waste Using the Experimental Apparatus for Combustibility (소형 연소장치를 이용한 음식폐기물 연소 특성 연구)

  • Chae, JongSeong;Yang, SeungJae;Kim, SeokWan;Lee, JaeHee;Ohm, TaeIn
    • New & Renewable Energy
    • /
    • v.16 no.2
    • /
    • pp.47-53
    • /
    • 2020
  • The amount of food waste and its water content depends on both the season and region. In particular, the water content typically varies between 73.8 wt.% and 83.3 wt.%, depending on the proportion of vegetables. Current food waste drying technologies are capable of reducing the water content to less than 10 wt.%, while increasing the heating value. Ongoing studies aim to utilize dried food waste as fuel. Food waste can be used to produce solid refuse fuel (SRF) by mixing it with various solid fuels or other types of waste. The analysis of specimens is very important when considering the direct combustion of food waste or its co-firing with solid fuels. In this study, the weight reduction of specimens after burning them in a small combustor, and compared with the results of thermogravimetric analysis (TGA). The concentration of various chemicals was also measured to define the characteristics of waste generation. Performed proximate analysis, elemental analysis, TGA, combustion experiment, the heating value, and derivative thermogravimetry (DTG).

A Study on the Gasification of Combustible Waste (가연성 폐기물의 가스화에 관한 연구)

  • 정준화
    • Journal of Environmental Health Sciences
    • /
    • v.16 no.2
    • /
    • pp.89-95
    • /
    • 1990
  • This study was investigated to the energy recovery by the pyrolysis of waste tyre. the pyrolysis of the waste tyre was made by using the pyrolysis chamber for the gasification and the combustion chamber for the combustion of the pyrolysis gas. In batch system, the amount of waste tyre was put 150kg in the pyrolysis chamber and the proper air flow rate for the stable production of the pyrolysis gas was 0.95Nm$^{3}$ /min. the production time of the pyrolysis gas was stable above 210minutes, and the stable production rate was above 3.8Nm$^{3}$ /min. The production temperature of pyrolysis gas was 170$^{\circ}$C and combustion temperature of pyrolysis gas was 1,000$^{\circ}$C. The combustible component of washing gas in pyrolysis gas of waste tyre was CO, CH$_{4}$, $C_{2}H_{6}$ and $C_{3}H_{8}$, and total amount was 22.7%. Heat value of condensed material was 9,804Kcal/kg. The average concentration of air pollutants between cyclone and scrubber was CO 420.4ppm, SO$_{x}$ 349.8ppm. NO$_{x}$ 68.Sppm, HCl 24.4ppm and Dust 240.0g / Nm$^{3}$, respectively.

  • PDF

A Study on Recycling of Waste Tire (폐타이어 재 자원화를 위한 연구)

  • 이석일
    • Journal of Environmental Health Sciences
    • /
    • v.26 no.4
    • /
    • pp.38-44
    • /
    • 2000
  • Compared to other waste, waste tire has much discharge quantity and calorie. When we use waste heat from waste tire, it can be definitely better substitute energy than coal and anthracite in high oil price age. To use as a basic data for providing low cost and highly effective heating system, following conclusion was founded. Annual waste tire production was 19,596 million in 1999, Recycling ratio was almost 55% and more than 8.78 million was stored. Waste tire has lower than 1.5% sulfur contain ratio which is resource of an pollution, So it is a waste fuel which can be combustion based on current exhaust standard value without any extra SOx exclusion materials. Waste tire has 9,256Kcal/kg calorific value and it is higher than waste rubber, waste rubber, waste energy as same as B-C oil. When primary and second air quantity was 1.6, 8.0 Nm$^3$/min, dry gas production time was 270min and total combustion time was 360 min. In the SOx, NOx, HC of air pollution material density were lower than exhaust standard value at the back of cyclone and dusty than exhaust standard value without dust collector.

  • PDF

The Study of Waste Treatment using Advanced Oxygen Enriched Combustion System (산소부하 연소 시스템을 이용한 폐기물 열처리에 관한 연구)

  • Lee, Keon-Joo
    • 한국연소학회:학술대회논문집
    • /
    • 2003.05a
    • /
    • pp.231-239
    • /
    • 2003
  • In this study, the waste of landfill was treated using advanced enriched oxygen combustion system. The oxygen concentration of this study was 21%, 25%, 30% and 40% and the operating capacity was 200 g/min and the residence time was 10 minutes. As increased the oxygen concentration of combustion air. temperature of the incinerator was increased and the temperature was increased rapidly when the oxygen concentration was 30%. As increased the oxygen concentration, the NOx (ppm) of flue gas increase d for thermal NOx, however the CO (ppm) of flue gas decreased according to the increase of combustion efficiency . The optimum operation condition of incineration was obtained when the oxygen concentration is 30%${\sim}$40%. The unburned carbon of ash decreased from 10% to 4% when the oxygen concentration was increased from 21% to 30%, therefore the high combustion efficiency can be obtained if used the oxygen enriched combustion system.

  • PDF