• 제목/요약/키워드: Warm working

검색결과 63건 처리시간 0.026초

정수압 압출 소재의 열처리 조건에 따른 마그네슘합금(AZ31)의 특성 변화 (Characteristics of Extruded Mg alloy(AZ31) for various annealing temperatures)

  • 서영원;최호준;윤덕재
    • 한국소성가공학회:학술대회논문집
    • /
    • 한국소성가공학회 2005년도 추계학술대회 논문집
    • /
    • pp.463-466
    • /
    • 2005
  • Restoring ductility or removing residual stresses is a necessary operation when a large amount of cold working is to be performed, such as in a cold-forging or warm forging process. The advantage of annealing temperatures was investigated. After Hydrostatic Extrusion process, extruded materials were annealed at $200^{\circ}C,\;350^{\circ}C,\;450^{\circ}C$ for 1 hour. Microstructure of the annealed material was observed to make an understand about the difference in mechanical properties.

  • PDF

북서태평양 명태 어장의 해황 - 2 . 기후의 특성 - (Oceanography in the Waters Adjacent to Kamchatka and Kurile islands in the Northwestern Pacific - II)

  • 한영호
    • 수산해양기술연구
    • /
    • 제13권1호
    • /
    • pp.17-25
    • /
    • 1977
  • For four calender years (1971-1974), daily observations of weather conditions (air temperature, humidity, wind speed, wind direction, cloud amount, fog, precipitation etc.) at six stations in the north western Pacific Ocean are used to calculate mean monthly values and to check extra-conditions. At Petropavlosk and Miko'skoe, where indicate the characteristics of modified continental climate, the temperature and humidity are high in summer, and Iow in winter. At A Dak and She Mya, where indicate the characteristics of warm current type maritime climate, humidity is high in all season and annual range of air temperature is nearly negligible. At Simusir and Vasi!' eva, where indicate the characteristics of cold current type maritime climate, humidity is high in all season and annual range of air temperature is $15^{\circ}C.$ As dry cooling power is relatively high in winter, working condition on deck is bad. Most of fogs are advection fog in the area of cold current type climate in summer.

  • PDF

유한요소 시뮬레이션을 이용한 알루미늄 7075 복합 압출재에 대한 공정개선 연구 (A Study on Process Improvement of Combined Extrusion with Aluminum Alloy 7075)

  • 김진복;이지억;강범수
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 1996년도 제6회 학술강연회논문집
    • /
    • pp.197-205
    • /
    • 1996
  • A combined extrusion process studied here consists of forward and backward extrusion, and it is formed in single operation. The metal flow involved in the operation has appeared to be difficult to analyze accurately because of mixed directions of the flow. In this study, conventional two operations of a forward and a backward extrusions is transformed into one operation of mixed extrusion. A process designed by an industry expert is simulated by the rigid-plastic finite element method to investigate the metal flow and defects. In addition to the FEM simulation, experimental analysis has been carried out to confirm the design in industry, which includes material characterization, preliminary expriment, and whole experimental forming operation. The experimental results show that warm forming of extrusion is more desirable than cold working and hot forming in view of grain growth. Also two conditions of lubrication between workpiece and die has been investigated.

  • PDF

성층 축열 시스템에서의 열 저장 특성에 관한 실험적 연구 (An experimental study on thermal storage characteristics in the thermally stratified water storage system)

  • 고재윤;김영기;이채문;임장순
    • 한국태양에너지학회 논문집
    • /
    • 제21권4호
    • /
    • pp.37-46
    • /
    • 2001
  • This study describes the experimental study that focuses on the effects that distributor shapes and flow rate variations have an influence on the stratification in a rectangular thermal storage tank. Experiments were carried out under the conditions that the flow rates of working fluid are 20, 10 and $5\ell$/min. The storage tank is initially filled with chilled water of $1^{\circ}C$, and is extracted through the bottom at the same rate as the return warm water from load is entered through the distributor at the top of the tank. The thermo-cline forms at the top of the storage tank as the warm water enters the tank from the load through the distributor and the thermo-cline thickness increases with time. Emphasis is given to the effects of mixing at the inlet that increases the thermo-cline decay Flow rate variation and inlet distributor shapes are the important parameters in deciding the performance of a storage system. Stratification degree increases with decreasing in inlet flow rate under $10\ell$/min. Experiments shows that better thermal stratification can be obtain using the distributor to limit momentum mixing at the inlets and outlets. Also, 12% of improvement in the thermal energy usage has been achieved using the modified distributor discharging same flow rate in each lateral ports.

  • PDF

상변화물질과 열관을 병렬 조합한 위성부품 열제어장치의 수치해석적 연구 (Numerical Study on the Thermal Control Device for Satellite Components Using the Phase Change Material Combined with Heat Pipe in Parallel)

  • 신윤섭;김태수;김택영;서영배;서정기;현범석;전형열
    • 한국항공우주학회지
    • /
    • 제44권4호
    • /
    • pp.373-379
    • /
    • 2016
  • 주기적 단속적으로 작동하는 위성부품의 열제어를 위하여 고상-액상 상변화물질(PCM, Phase Change Material)과 열관을 병렬로 결합한 열제어장치를 제안하였으며, 이의 성능을 수치해석을 통하여 검증하였다. 상변화 중 큰 잠열과 일정하게 유지되는 온도에 의하여 작은 방열판 면적에서도 부품의 최고온도를 제어할 수 있으며, 냉각기에는 PCM에 축적된 에너지가 방출됨으로써 보온히터 소모전력을 절약할 수 있다. 동일한 형태의 Al TBM(Thermal Buffer Mass)을 사용하면 비슷한 효과를 기대할 수 있으나, 질량과 보온히터의 소모전력이 증가하므로 PCM에 비하여 비효율적이다. 설계된 PCM 열제어장치는 발열량과 작동시간에 따라 그 양을 최적화할 수 있다.

직장 남성들의 근무복 실태조사 연구(1) -근무복 만족도와 선호도를 중심으로- (A Research Study on Work-Man's Uniform(1))

  • 박선희;서미아
    • 복식문화연구
    • /
    • 제4권1호
    • /
    • pp.75-91
    • /
    • 1996
  • The work-man's uniform should be coincident wit the image of his firm and accounted of the function according as its purpose. We made questions to 404 workers at 8 firm in our country through the questionnaire papers to know about a work-man's uniform and researched whether the satisfactory in wearing his uniform had relation with his type of business, grade, carrier, age, marriage, and monthly income. The results of this study is as follows; 1. In the uniform status of the fir, thee were many jumper styles in he design of the uniform. The color of that was more dark than bright and the materials of one was used much more chemical fiber than natural fiber. Each of the field office supplied the uniform to his work-man more frequently than the main office. All of firm payed off the uniform expense and decision of the uniform design was almost made both the firm and the labour union. 2. In he satisfaction of the uniform, the satisfaction of uniform was shown high in the design, color, materials, size and function. The highest dissatisfaction reason is as follows; it was disagreeable to concrete design in the design and dark color and keeping warm or draft was bad in the materials, the bust and pant's length was long in the size. 3. In preference of the uniform, the older of preference in the design was what the working environment and the image of firm was suitable, the characteristic uniform. The order of preference in the color was beige, blue, grey. The preference of in the materials was good to keep warm and draft. The preference in the pattern was 'no pattern' every type of business. The experts, or administrators and office workers than others preferred 'no pattern' of the uniform in the pattern.

  • PDF

Vinyl House 내의 환경조건과 인체적응에 관한 실험연구 (A Study on Experiments the Environmental Conditions and the Adaptation of the Human Body in the Vinyl House)

  • 심부자
    • Journal of Preventive Medicine and Public Health
    • /
    • 제27권1호
    • /
    • pp.59-73
    • /
    • 1994
  • The purpose of this study is to experiments the environmental conditions and the adaption of the human body in the vinyl house. The study was done in spring and winter and experimental clothes were used working clothes in the vinyl house. The results are as follows. 1. Environmental Conditions In the spring season, the indoor air temperature was $27.4{\pm}3.7^{\circ}C$ and the outdoor air temperature was $14.4{\pm}2.7^{\circ}C$. In the winter season, the indoor air temperature was $18.3{\pm}4.8^{\circ}C$ and the outdoor air temperature was $7.6{\pm}2.5^{\circ}C$ on the average. 2. Skin Temperature In the spring season, the mean skin temperatures indoor and outdoor were $33.81{\pm}0.7^{\circ}C\;and\;31.57{\pm}0.8^{\circ}C$ respectively, a difference of $2.24^{\circ}C$. In the winter season, they were $31.95{\pm}1.93^{\circ}C\;and\;29.86{\pm}0.55^{\circ}C$ respectively, a difference of $2.09^{\circ}C$. 3. Clothing Climate In the spring season, the temperature and humidity in the inner layer of clothing were $34.77{\pm}0.80^{\circ}C\;and\;70.75{\pm}1.65%$ indoor, $31.9{\pm}0.52^{\circ}C\;and\;51.9{\pm}3.70%$ outdoor respectively. In the winter season, those were $32.52{\pm}1.04^{\circ}C\;and\;64.65{\pm}3.68%$ indoor, $30.27{\pm}0.96^{\circ}C\;and\;45.07{\pm}2.68%$ outdoor respectively. 4. Physiological Factors Body temperature increased slightly and the pulse rate also rises, but blood pressure decreased a little with the rise of environmental temperature both in the spring and winter seasons. 5. Psychological Factors Thermal sensation in the spring season was expressed as 'slightly warm' or 'warm' indoor and as 'neutral' in the open air, while in the winter it was expressed as 'neutral' or 'slightly warm' outdoor the house and as 'cold' in the open air. Comfort sensation was characterized as 'uncomfortable' or 'slightly uncomfortable' indoor both in the spring and winter seasons, but in the open air it was characterized as 'comfortable' in the spring and as 'slightly uncomfortable' in the winter.

  • PDF

폐쇄형 해양온도차발전 사이클에 관한 연구 (A Study of Closed OTEC Power Plants)

  • 신상호;정동수;김종보;서태범;천원기;오정무
    • 태양에너지
    • /
    • 제17권4호
    • /
    • pp.23-33
    • /
    • 1997
  • 본 연구에서는 Rankine 사이클을 이용한 해양 온도차 발전 시스템을 컴퓨터로 모사했고 작동유체를 변화시켜 가면서 그 성능을 비교하였다. 증발기와 응축기는 UA(총괄열전달계수$\times$전열면적)와 LMTD(대수평균온도차) 방법으로 모사하였으며 터빈과 펌프는 등엔트로피 효율로 모사하였다. 작동유체로는 R22, R290, R1270, R134a, R125, R143a, R32, R410A 그리고 암모니아 등을 사용하였다. 모사 결과 OTEC 발전 시스템의 효율은 작동유체에 상관없이 거의 일정한 것으로 드러났다. 한편 증발기 출구에서의 과열도와 응축기 출구에서의 과냉도는 시스템의 성능에 거의 영향을 미치지 않는 것으로 나타났지만 터빈의 효율과 열교환기의 크기는 시스템 성능에 큰 영향을 미치는 것으로 나타났다. 마지막으로 따뜻한 표층수와 차가운 심해수 사이의 온도차가 $20^{\circ}C$이상일 때 실제로 전기를 생산할 수 있다는 사실을 확인했다.

  • PDF

Observations on Normal Body Temperatures in Differently Climate Conditions

  • Nguyen, My-Hang;Hiromi Tokura
    • Journal of Photoscience
    • /
    • 제9권2호
    • /
    • pp.406-408
    • /
    • 2002
  • In order to know the characteristics of circadian rhythms in core temperature in tropical inhabitants, we measured rectal temperatures every 10 min for 24 hrs in 6 Vietnamese, 20 - 22 yrs (5 males and I females) under natural conditions. Average light intensity was 16000 lx. Ambient temperatures ranged from 33 to 36 oC. These data obtained were compared with those in Japanese setters and the Polish inhabitants. The participants were sitting mostly during wakefulness and lying in bed during sleep. The results obtained are summarized as follows: I) The average maximum value was 37.7 oC, which was significantly higher than in the Japanese and Polish as well. 2) The average minimum value was 36.4 oC, which was also lower. 3) A range of oscillation was 1.3 oC, which was clearly greater than in the people living in the temperate areas. The higher maximum value of core temperature, which was actively regulated under warm temperature, seemed of adaptive significance in order to reduce water consumption. A greater rage of oscillation in tropical Vietnamese people might have ecological significance for efficient acclimatization in the environment with strong light intensity and high ambient temperature, suggesting that the setpoint of core temperature could show a greater range of oscillation.

  • PDF

원자력발전소 온배수를 이용한 해양 온도차발전 사이클 해석 (Cycle Simulation on OTEC System using the Condenser Effluent from Nuclear Power Plant)

  • 김남진;전용한;김종보
    • 한국태양에너지학회 논문집
    • /
    • 제27권3호
    • /
    • pp.37-44
    • /
    • 2007
  • For the past few years, the concern for clean energy has been greatly increased. Ocean Thermal Energy Conversion(OTEC) power plants are studied as a viable option for the supply of clean energy. In this paper, the thermodynamic performance of OTEC cycle was examined. Computer simulation programs were developed under the same condition and various working fluids for closed Rankine cycle, regeneration cycle, Kalina cycle, open cycle and hybrid cycle. The results show that the regeneration cycle using R125 showed a 0.17 to 1.56% increase in energy efficiency, and simple Rankine cycle can generate electricity when the difference in warm and cold sea water inlet temperatures are greater than $15^{\circ}C$. Also, the cycle efficiency of OTEC power plant using the condenser effluent from nuclear power plant instead of the surface water increased about 2%.