• 제목/요약/키워드: Warm air

검색결과 307건 처리시간 0.021초

2차 공기 분사에 의한 스파크 점화 가솔린 엔진의 배기 Hydrocarbon 저감에 관한 실험적 연구 (An Experimental Study for Reducing the Exhaust Hydrocarbon Emission at SI Engine Using Timed Secondary Air Injection)

  • 심현성;김세준;정석호
    • 한국자동차공학회논문집
    • /
    • 제7권7호
    • /
    • pp.104-112
    • /
    • 1999
  • An experimental study for reducing the exhaust hydrocarbon emission at spark ignition engine using timed secondary air injection is carried out . In this study, secondary air injection timings and durations are controlled to decrease the hydrocarbon emission and to increase exhaust gas temperature at cold and warm-up engine conditions. The hydrocarbon reduction rate and exhaust gas temperature are compared between timed secondary air injection and continuous air injection. The optimum secondary air injection timing for reducing the hydrocarbon emission is at the exhaust valve open timing. At some engine conditions , the hydrocarbon emissions are decreased to 10% of engine raw values and exhaust gas temperatures increase by 20$0^{\circ}C$ with times secondary air injection . Timed secondary air injection has more hydrocarbon reduction rate that continuous secondary air injection except some engine conditions.

  • PDF

고온 우회가스 및 에어댐퍼 사용을 통한 히트펌프 건조기 승온단계 에너지 효율 향상을 위한 사이클 및 유동해석 연구 (A Study on Cycle and Flow Analysis for Improvement of Energy Efficiency of a Heat Pump Dryer with Hot Bypass Gas and Air Dampers During Warm-up Stage)

  • 박상준;황일선;이영림
    • 한국산학기술학회논문지
    • /
    • 제13권9호
    • /
    • pp.3827-3834
    • /
    • 2012
  • 최근 많은 열에너지를 필요로 하는 열풍식 건조기 대신 에너지 효율이 높은 히트펌프 건조기가 제지, 섬유, 목재, 식품 등 다양한 분야에서 사용되고 있다. 본 논문에서는 냉동 농산물 건조 초기에 전기히터 사용을 최소화하여 에너지 효율을 높이고자, 압축기 출구 고온가스 우회 시스템에 대한 히트펌프 사이클 특성을 이론적으로 고찰하였다. 또한, 추가 열을 확보하기 위하여 외부공기 유입을 위한 댐퍼를 고려하였고 이의 최적화를 통해 에너지 효율 향상이 가능함을 보였다.

보조 외부 증발기를 이용한 히트펌프 건조기 성능 향상에 관한 연구 (A Study on Performance Improvement of a Heat Pump Dryer with an Extra Evaporator Outside)

  • 이영림;박상준;황일선
    • 설비공학논문집
    • /
    • 제24권10호
    • /
    • pp.711-717
    • /
    • 2012
  • A heat pump dryer for the frozen food needs to preheat the air to a certain temperature where condensation can efficiently occur. In this study, an analysis of a heat pump dryer performance with operating conditions, an analysis of supplying heat with internal and external evaporators and a warm-up experiment with the evaporators have been performed. The results showed that the external evaporator can significantly accelerate the warm-up time of the dryer, so that it can reduce power consumption greatly. The use of the external evaporator is more efficient for higher ambient temperature. In addition, it was found that COP decreases and the range of evaporating pressure for the evaporator becomes narrower as the condensing temperature of the condenser increases.

대류 난방시 실내열환경에 관한 연구 -상하온도차에 대한 온열쾌적감- (The Study on Indoor Thermal Environment during Convection Heating - Thermal Comfort Sensation for Vertical Temperature Differences -)

  • 김동규;금종수
    • 한국환경과학회지
    • /
    • 제14권2호
    • /
    • pp.215-220
    • /
    • 2005
  • Thermal neutrality is not enough to achieve thermal comfort. The temperature level can be the optimal, and still people may complain. This situation is often explained by the problem of local discomfort. Local discomfort can be caused by radiant asymmetry, local air velocities, too warm and too cold floor temperature and vertical temperature difference. This temperature difference may generate thermal discomfort due to different thermal sensation in different body parts. Therefore, thermal comfort can not be correctly evaluated without considering these differences. This study investigates thermal discomfort sensations of different body parts and its effect on overall thermal sensation and comfort in air-heating room. Experimental results of evaluating thermal discomfort at different body parts in an air-heating room showed that thermal sensation on the shoulder was significantly related to the overall thermal sensation and discomfort. Although it is known that cool-head, warm-foot condition is good for comfort living, cool temperature around the head generated discomfort.

낙동강 구미 보의 증기 안개 발생 시의 미기상학적 특성 (Micro-meteorological Characteristics during the Steam Fog over the Gumi Reservoir of Nakdong River)

  • 김해동;조창범;서광수
    • 한국환경과학회지
    • /
    • 제25권3호
    • /
    • pp.405-415
    • /
    • 2016
  • We analyzed the micro-meteorological characteristics during typical steam fog over the Gumi Reservoir of Nakdong river with the field observation data for recent 2 year(1 April 2013~31 March 2015) collected by the national institute of meteorological research, KMA. Steam fog occur when the cold drainage flows over the warm water surface. As the sensible and latent heat from water are provided to the air, the instability of lower atmosphere is increased. The resultant vertical mixing of warm, moist air near water surface and cold air aloft causes the formation of status cloud. The convection strengthened by radiative cooling of the upper part of the stratus causes the fog to propagate downward. Also, the temperature at the lowest atmosphere is increased rapidly and the inversion near surface disappear by these processes when the fog forms. The increase of wind speed is observed because the downward transportation of momentum is caused by vertical mixing.

동계 한반도 동·서 연안역 기온에 미치는 수온의 영향 (Influence of Water Temperature on Air Temperature around Eastern and Western Coastal Areas of the Korean Peninsula during Winter)

  • 홍철훈
    • 한국수산과학회지
    • /
    • 제52권1호
    • /
    • pp.92-96
    • /
    • 2019
  • The influence of water temperature (WT) on air temperature (AT) in the eastern and western coastal regions of the Korean peninsula in the winter was investigated using historical data from the Korean Meteorological Agency (KMA) and the National Institute of Fisheries Science (NIFS), focusing on the relationship between AT and WT. The data analysis shows that, during winter, the AT is generally higher by +1.9 to $+2.7^{\circ}C$ at Kangreung ($37.2^{\circ}N$) in the eastern region than at Inchon ($37.4^{\circ}N$) in the western region, i.e., the AT in the eastern region of the Korean Peninsula tends to be higher overall than that in the western region when similar latitudes are compared. On the other hand, in the winters of 1977-2006, the WT at Sokcho was higher by $+0.8^{\circ}C$ (January) to $+2.3^{\circ}C$ (March) than that at Sochungdo, directly resulting in increased AT ($+1.22^{\circ}C$) at Sokcho. This study suggests that higher AT in the eastern region during winter is caused by the influence of water flow, such as the East Korean Warm Current in the East/Japan Sea.

Vinyl House 내의 환경조건과 인체적응에 관한 실험연구 (A Study on Experiments the Environmental Conditions and the Adaptation of the Human Body in the Vinyl House)

  • 심부자
    • Journal of Preventive Medicine and Public Health
    • /
    • 제27권1호
    • /
    • pp.59-73
    • /
    • 1994
  • The purpose of this study is to experiments the environmental conditions and the adaption of the human body in the vinyl house. The study was done in spring and winter and experimental clothes were used working clothes in the vinyl house. The results are as follows. 1. Environmental Conditions In the spring season, the indoor air temperature was $27.4{\pm}3.7^{\circ}C$ and the outdoor air temperature was $14.4{\pm}2.7^{\circ}C$. In the winter season, the indoor air temperature was $18.3{\pm}4.8^{\circ}C$ and the outdoor air temperature was $7.6{\pm}2.5^{\circ}C$ on the average. 2. Skin Temperature In the spring season, the mean skin temperatures indoor and outdoor were $33.81{\pm}0.7^{\circ}C\;and\;31.57{\pm}0.8^{\circ}C$ respectively, a difference of $2.24^{\circ}C$. In the winter season, they were $31.95{\pm}1.93^{\circ}C\;and\;29.86{\pm}0.55^{\circ}C$ respectively, a difference of $2.09^{\circ}C$. 3. Clothing Climate In the spring season, the temperature and humidity in the inner layer of clothing were $34.77{\pm}0.80^{\circ}C\;and\;70.75{\pm}1.65%$ indoor, $31.9{\pm}0.52^{\circ}C\;and\;51.9{\pm}3.70%$ outdoor respectively. In the winter season, those were $32.52{\pm}1.04^{\circ}C\;and\;64.65{\pm}3.68%$ indoor, $30.27{\pm}0.96^{\circ}C\;and\;45.07{\pm}2.68%$ outdoor respectively. 4. Physiological Factors Body temperature increased slightly and the pulse rate also rises, but blood pressure decreased a little with the rise of environmental temperature both in the spring and winter seasons. 5. Psychological Factors Thermal sensation in the spring season was expressed as 'slightly warm' or 'warm' indoor and as 'neutral' in the open air, while in the winter it was expressed as 'neutral' or 'slightly warm' outdoor the house and as 'cold' in the open air. Comfort sensation was characterized as 'uncomfortable' or 'slightly uncomfortable' indoor both in the spring and winter seasons, but in the open air it was characterized as 'comfortable' in the spring and as 'slightly uncomfortable' in the winter.

  • PDF

개별환경제어시스템의 열 및 유동 해석 (Air Flow and Heat Transfer Analysis of Personal Environment Module System)

  • 조은준;서태범;박영철
    • 설비공학논문집
    • /
    • 제13권4호
    • /
    • pp.252-261
    • /
    • 2001
  • Room air flow and temperature distribution was numerically investigated where a PAC(personal air conditioning) system was installed. The calculated results were compared with those from experiments. The effects of the important operation parameters such as the air flow rate, velocity, and temperature at the diffuser on the thermal performance of the system were studied. The possibility of energy saving using the PAC system was verified from the results, It was shown that the warm air from the diffuser could not spread over the whole task area if the inlet temperature was too high.

  • PDF

실내 공기질 개선을 위한 환기기술에 관한 연구 (A Study on the ventilation Technology for Indoor Air Quality Improvement)

  • 장태현;조현욱
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제29권5호
    • /
    • pp.540-551
    • /
    • 2005
  • In this research, We'll focus on warm environment and ventilation characteristics when utilizing intake ports, exhaust port and 4-way cassettes for removing heat and polluted air. Four way cassettes have been typical air conditioning units for offices since the multi air-conditioner was introduced. The following installation cases will also be discussed: 1) 4-way cassette's operation without intake ports and exhaust port. 2) Effect of the position of intake port and exhaust ports. 3) cooling air flow, temperature. distribution and local supply index according to the air flow rate from 4-way cassettes.

낙동강 유역 안개 발생시 기상 특성: 강정고령보 사례를 중심으로 (Atmospheric Characteristics of Fog Incidents at the Nakdong River : Case Study in Gangjeong-Goryeong Weir)

  • 박준상;임윤규;김규랑;조창범;장준영;강미선;김백조
    • 한국환경과학회지
    • /
    • 제24권5호
    • /
    • pp.657-670
    • /
    • 2015
  • Visibility and Automatic Weather System(AWS) data near Nakdong river were analyzed to characterize fog formation during 2012-2013. The temperature was lower than its nearby city - Daegu, whereas the humidity was higher than the city. 157 fog events were observed in total during the 2 year period. About 65% of the events occurred in fall (September, October, and November) followed by winter, summer, and spring. 94 early morning fog events of longer than 30 minutes occurred when south westerly wind speed was lower than 2 m/s. During these events, the water temperature was highest followed by soil surface and air temperatures due to the advection of cold and humid air from nearby hill. The observed fog events were categorized using a fog-type classification algorithm, which used surface cooling, wind speed threshold, rate of change of air temperature and dew point temperature. As a result, frontal fog observed 6 times, radiation 4, advection 13, and evaporation 66. The evaporation fog in the study area lasted longer than other reports. It is due to the interactions of cold air drainage flow and warm surface in addition to the evaporation from the water surface. In particular, more than 60% of the evaporation fog events were accompanied with cold air flows over the wet and warm surface. Therefore, it is needed for the identification of the inland fog mechanism to evaluate the impacts of nearby topography and land cover as well as water body.