• 제목/요약/키워드: Wall flow

검색결과 2,971건 처리시간 0.039초

수직벽면형 무동력 태양열 시스템 작동성능에 관한 실험적 연구 (An experimental study on the operating performance of facade installed natural circulation type solar thermal system)

  • 백남춘;이왕제;이진국;이순명
    • 한국태양에너지학회 논문집
    • /
    • 제35권4호
    • /
    • pp.1-7
    • /
    • 2015
  • The operation of the natural circulation type solar heating systems with facade integrated collector was analyzed by experiment. Two different types of flat plate solar collectors were used for these experiments. One was for the normal flat plate solar collector with the size of 1m*2m and the other was for the large size solar collector with $4m^2$(1m*4m). The experiments were carried out to investigate the effect of the series or parallel connection method on the performance of the collectors. As a result, the solar thermal system which is installed on the wall or facade would be applicable for the natural circulation type if the system design reflects various parameters, including collector connecting method(series or parallel), to provide enough vertical height between collector and storage tank, and to reduce pressure loss due to collector and piping network, etc. The natural circulation type of solar thermal system as proposed in this study can increase the system reliability by removing or minimizing the use of the components such as pump, controller, sensors which may cause serious troubles of the system for a long-time operation

오블롱 셀 플레이트 열교환기에서의 R-l34a, R-407C, R-410A의 증발 열전달에 관한 실험적 연구 (Study on Evaporation Heat Transfer of R-l34a, R-407C, and R-410A in the Oblong Shell and Plate Heat Exchanger)

  • 박재홍;김영수
    • 설비공학논문집
    • /
    • 제16권9호
    • /
    • pp.845-854
    • /
    • 2004
  • The evaporation heat transfer coefficient for R-l34a, R-407C (a mixture of 23wt% R-32, 25 wt% R-125, and 52 wt% R-l34a) and R-410A (a mixture of 50 wt% R-32 and 50 wt% R-125) flowing in the oblong shell and plate heat exchanger were investigated experimentally in this study. Four vertical counterflow channels were formed in the exchanger by four plates of commercial geometry with a corrugated sinusoid shape of a chevron angle of 45 degree. The effects of the mean vapor quality, mass flux, heat flux, and saturation temperature of different refrigerants on the evaporation heat transfer were explored in detail. Similar to the case of a Plate heat exchanger, even at a very low Reynolds number, the flow in the oblong shell and plate heat exchanger remains turbulent. It is found that the evaporation heat transfer coefficient in the plates is much higher than that in circular pipes. The present data show that the evaporation heat transfer coefficients of all refrigerants increase with the vapor quality. At a higher mass flux h, is higher than for the entire range of the vapor quality. Raising the imposed wall heat flux was found to slightly improve h$_{r}$, while h$_{r}$ is found to be lower at a higher refrigerant saturation temperature. A comparison of the performance of the various refrigerants reveals that R-410A has the highest heat transfer performance followed by R-l34a, and R-407C had the lowest performance of the refrigerants tested. Based on the present data, empirical correlations of the evaporation heat transfer coefficient were proposed.sed.

합성가스(H2/CO)/공기 예혼합 충돌화염의 연소 및 열전달 연구 Part II : 열전달 특성 (A Study on Combustion and Heat Transfer in Premixed Impinging Flames of Syngas(H2/CO)/Air Part II: Heat Transfer Characteristics)

  • 심근선;정병규;이용호;이기만
    • 한국수소및신에너지학회논문집
    • /
    • 제25권1호
    • /
    • pp.59-71
    • /
    • 2014
  • An experimental study has been conducted to investigate the heat transfer characteristics of laminar syngas/air mixture with 10% hydrogen content impinging normally to a flat plate of cylinder. Effects of impinging distance, Reynolds number and equivalence ratio as major parameters on heat fluxes of stagnation point and radial direction were examined experimentally by the direct photos and data acquisitions from heat flux sensor. In this work, we could find the incurved flame behavior of line shaped inner top-flame in very closed distance between flat plate and burner exit, which has been not reported from general gas-fuels. There were 3 times of maximum and 2 times minimum heat flux of stagnation point with respect to the impinging distance for the investigation of Reynolds number and equivalence ratio effect. It was confirmed that the maximum heat flux of stagnation point in 1'st and 2'nd peaks increased with the increase of the Reynolds number due to the Nusselt number increment. There was a third maximum rise in the heat flux of stagnation point for larger separation distances and this phenomenon was different each for laminar and turbulent condition. The heat transfer characteristics between the stagnation and wall jet region in radial heat flux profiles was investigated by the averaged heat flux value. It has been observed that the values of averaged heat flux traced well with the characteristics of major parameters and the decreasing of averaged heat flux was coincided with the decreasing trend of adiabatic temperature in spite of the same flow condition, especially for impinging distance and equivalence ratio effects.

노즐 목 내부형 핀틀추력기의 추력 및 공력하중 특성 (Thrust and Aerodynamic Load Characteristics of an Internal Pintle Thruster)

  • 최준섭;김동연;허환일
    • 한국추진공학회지
    • /
    • 제21권3호
    • /
    • pp.1-9
    • /
    • 2017
  • 노즐 목 내부형 핀틀추력기에서 핀틀 행정거리가 추력기 성능에 미치는 영향에 대해 전산수치해석 연구를 수행하였다. 해석결과 핀틀 행정거리가 증가함에 따라 추력조절비는 2% 이내였고, 공력하중비는 최대 22%로 확인되었다. 노즐 목을 지난 유동이 핀틀의 형상으로 인해 급격히 팽창하며 충격파가 발생하였다. 특히, 핀틀 행정거리 4, 5 mm에서는 충격파가 노즐 벽면에 부딪치며 박리거품이 발생하였다. 고도에 따라서는 추력은 증가하였고 공력하중은 감소하였지만, 그 차이가 1.5% 이내로 작았다. 보어가 있는 경우 핀틀 팁의 면적 감소로 공력하중이 감소하는 결과를 보였다.

사각 덕트 내부 열전달 향상을 위한 요철의 단락 효과 (Effects of Discrete Rib-Turbulators on Heat/Mass Transfer Augmentation in a Rectangular Duct)

  • 권혁진;우성제;조형희
    • 대한기계학회논문집B
    • /
    • 제24권5호
    • /
    • pp.744-752
    • /
    • 2000
  • The influence of arrangement and length of discrete ribs on heat/mass transfer and friction loss is investigated. Mass transfer experiments are conducted to obtain the detailed local heat/mass transfer information on the ribbed wall. The aspect ratio (width/height) of the duct is 2.04 and the rib height is one tenth of the duct height, such that the ratio of the rib height to hydraulic diameter is 0.0743. The ratio of rib-to-rib distance to rib height is 10. The discrete ribs were made by dividing each continuous rib into 2, 3 or 5 pieces and attached periodically to the top and the bottom walls of the duct with a parallel orientation The combined effects of rib angle and length of the discrete ribs on heat/mass transfer ae considered for the rib angles $({\alpha})\;of\;90^{\circ}\;and\;45^{\circ}$. As the number of the discrete ribs increases, the uniformity of the heat/mass transfer distributions increases. For $(\alpha})=90^{\circ}$, the heat/mass transfer enhancement with the discrete ribs is remarkable, while the heat/mass transfer performances are slightly higher than that of the transverse continuous ribs due to the accompanied high friction loss penalty. For $(\alpha})=90^{\circ}$, the average heat/mass transfer coefficients and the heat/mass transfer performances decrease slightly with the discrete ribs compared to the case of the angled continuous ribs.

액적충돌침식 영향 배관의 설계변경에 관한 연구 (Study on Design Change of a Pipe Affected by Liquid Droplet Impingement Erosion)

  • 황경모;이찬규;방극진;임영식
    • 대한기계학회논문집B
    • /
    • 제35권10호
    • /
    • pp.1097-1103
    • /
    • 2011
  • 액적충돌침식은 증기나 공기에 포함된 액적이 금속 소재에 고속으로 충돌할 때 모재가 손상되는 현상이다. 액적충돌침식 손상은 증기터빈이나 빗방울과 부딪치는 항공기에서 주로 발생되어 왔으나 최근에는 원전 배관에서도 발생하고 있다. 원전 배관 중에서도 특히 높은 압력강하가 발생하고 2상 증기가 흐르는 배관에서 주로 발생한다. 실제 2011년 초반 국내 한 원전에서는 2상 증기가 흐르는 배관에서 액적충돌침식 손상으로 인한 누설이 발생한 바 있다. 본 논문에서는 액적충돌침식 손상이 발생한 배관에 대하여 손상을 억제할 수 있는 설계변경 방안에 관한 연구를 수행하였다. 설계변경은 유체 유동측면에서 분석하였으며, 상용 수치해석 코드인 FLUENT를 이용하였다.

중심정맥카테터 삽입의 이상위치로 발생한 편측성 흉수 1례 (A Case of Pleural Effusion after Malposition of Central Venous Catheter)

  • 김재석;김상하;이낙원;권우철;최훈;변종원;홍태원;신계철;용석중
    • Tuberculosis and Respiratory Diseases
    • /
    • 제60권6호
    • /
    • pp.690-693
    • /
    • 2006
  • 중심정맥카테터 삽입 후 생길 수 있는 드문 합병증 중에 하나인 흉수 발생은 카테터와 관련된 혈관벽의 손상을 흉수 발생의 기전으로 설명하고 있다. 저자들은 우측 쇄골하정맥으로 이어지는 이상혈관 내로 카테터가 위치한 후 혈관 파열로 인하여 발생한 흉수 1례를 경험하였기에 문헌고찰과 함께 보고하는 바이다.

저 잡음 수중 청음기의 설계 방안 연구 -Ⅰ. 잡음 전달 특성 및 구조 변경 영향 - (Design and Evaluations of Underwater Hydrophone with Self Noise Suppressing Structures -Part Ⅰ. Noise Transfer Characteristics & Effects of Structure Modifications -)

  • 임종인;노용래
    • 한국음향학회지
    • /
    • 제16권2호
    • /
    • pp.10-15
    • /
    • 1997
  • 수중 청음기는 진동하는 물체 위에 설치되어 다양한 외부 잡음 원이 유입되는 환경에 노출되어 있다. 외부 잡음 원으로는 수중 청음기가 설치된 구조물 자체의 진동, 프로펠러 잡음, 그리고 유동 유기 잡음들이 있고, 이들 외부 잡음원은 실제 강도가 상당히 높아서 센서의 정확한 작동에 장애가 되고 있다. 본 연구에서는 외부 잡음에 무관한 고 정밀도, 저 잡음 특성을 갖는 수중 청음기를 개발하기 위하여 유한 요소법(FEM)을 사용하여 잡음 전달 특성의 분석 및 air pocket과 음향 감쇠층의 다양한 조합으로 이루어진 개선된 구조의 수중 청음기를 설계하고, 내 잡음성 평가를 하였다. 그 결과 센서 측면 하단부에 잡음 원이 위치할 경우 가장 큰 잡음 신호로 작용하므로 구조를 변경한 결과 기존 수중 청음기에 비해 59% 이상 내 잡음성을 증진 시켰다.

  • PDF

사각 및 원형 팁의 횡운동에 의한 물 메니스커스 형상변화에 관한 연구 (Study on a Shape Deformation of Water Meniscus for the Rectangular and Circular Tips Moving Horizontally)

  • 김상선;손성완;하만영;윤현식;김형락
    • 설비공학논문집
    • /
    • 제23권12호
    • /
    • pp.843-851
    • /
    • 2011
  • A two-dimensional immiscible water meniscus deformation phenomena on a moving tip in a channel has been investigated by using lattice Boltzmann method involving two-phase model. We studied the behavior of a water meniscus between the tip and a solid surface. The contact angles of the tip and a solid surface considered are in the range from $10^{\circ}$ to $170^{\circ}$. The velocity of the tip used in the study are 0.01, 0.001, and 0.0001. The shapes of tip considered are rectangular and circular. The behavior of water confined between the tip and a solid surface depends on the contact angles of the tip and a solid surface, and the tip velocity. When the tip is moving, we can observe the various behaviors of shear deformation of a water meniscus. As time goes on, the behavior of a water meniscus can be classified into three different patterns which are separated from the tip or adhered to the tip or sticked to a solid surface according to the contact angles and the tip velocity.

동시냉난방 열펌프의 전열회수 성능 특성에 관한 연구 (Experimental Study on the Performance of a Simultaneous Heating and Cooling Heat Pump in the Heat Recovery Mode)

  • 최종민;정현준;주영주;강훈;김용찬
    • 설비공학논문집
    • /
    • 제20권11호
    • /
    • pp.718-726
    • /
    • 2008
  • The cooling load in winter is significant in buildings and hotels because of the usage of office equipments and the high efficiency of wall insulation. Hence, the development of a multi-heat pump that can cover heating and cooling simultaneously for each indoor unit is required. In this study, the performance of a simultaneous heating and cooling heat pump was investigated in the heat recovery mode (HR mode). The system adopted a variable speed compressor using R410A with four indoor units and one outdoor unit. In the HR mode, the capacity and COP were improved as compared with those in the cooling or heating mode because the waste heat in the outdoor unit was utilized as useful heat in the indoor units. However, energy imbalance between heating and cooling capacity of each indoor unit was observed in the 2H-1C HR mode. Therefore, the performance of the system in the 2H-1C HR mode was enhanced by controlling refrigerant flow rate through the outdoor unit.