• Title/Summary/Keyword: Wall conditioning

Search Result 402, Processing Time 0.024 seconds

The Freezing Process of the Water Supply Pipe in an Exterior Wall (외벽측 급수관의 동결 과정에 관한 연구)

  • Kang, Han-Gi;Lee, Jae-Heon
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.19 no.11
    • /
    • pp.782-788
    • /
    • 2007
  • In this paper, the freezing process of the water supply pipe in the exterior wall of an apartment house was analyzed by numerical method. The thickness of the pipe insulation and the percentage of insulation damage were considered as parameters in this paper. In the cases of the 0%, 8% and 20% damaged of the 5mm thickness insulation, the freezing was completed after 13 hours, 10 hours and 7 hours respectively. And in cases of the 10mm thickness insulation, the freezing was completed after 18 hours, 10.5 hours and 8 hours respectively. As a result, it is predicted that the water freezing would occurred when the water supply pipe with 8% or 20% damaged insulation are installed in the exterior wall. However, the water freezing would not occurred when the water supply pipe with 10mm thickness insulation of 0% damage is installed in the exterior wall.

Numerical Investigation on Wall Flow Control for Preventing Contaminants Deposition inside a Duct (덕트 내 오염물질 퇴적 방지를 위한 벽면유동 제어에 관한 해석적 연구)

  • Lee, Banguk;Lee, Jeekeun
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.25 no.5
    • /
    • pp.261-268
    • /
    • 2013
  • Technologies for preventing contaminants deposition are a key issue in a modern duct system. When particulate matters deposit inside the exhaust pipes, which are widely used in the Urea-SCR system to reduce $NO_x$ emission from heavy duty diesel engines, many problems arise associated with increased flow resistance and corrosion. Therefore, the development of the urea deposition avoidance technologies is being treated as an important issue of the Urea-SCR system. An analytical study was carried out to investigate the effects of the wall flow around the mixer with the variation of the mixer housing surrounding and supporting the mixer, which is designed to increase the wall flow and then to reduce droplet deposition. The housing angles and the position of the mixer were changed:angles of $0^{\circ}$, $1^{\circ}$, $2^{\circ}$, and $3^{\circ}$, and mixer positions of 0 L, 0.5 L, and 1 L. The axial velocity distributions, maximum velocity, the half-width, and momentum distribution of the wall flow were investigated to examine the effect of the mixer-housing assembly geometry.

Effect of Radiation on Laminar Film Boiling of Binary Mixtures (2성분 혼합물질의 층류 막비등에서 복사열전달의 효과)

  • Seong Hyeon-Chan;Kim Kyoung-Hoon
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.16 no.10
    • /
    • pp.942-951
    • /
    • 2004
  • This paper presents the results of a theoretical study of the effect of radiation during free convective laminar film boiling for methanol/water binary mixtures on an isothermal vertical wall at atmospheric pressure. With the well-known boundary layer theory as a basis, a theoretical model has been formulated into consideration for mass diffusion at liquid phase. The equations are numerically solved by a similarity method to investigate the effects of radiation emissivity on the surface with various parameters such as wall superheat and composition of more volatile component at liquid phase far from the wall. From the results, the distributions of the physical quantifies are investigated in both phases. New correlations are proposed to predict the heat transfer coefficient of binary mixtures. It is shown that the proposed correlations are in good agreement with numerical results and with Bromley's correlation within maximum $11\%$ errors. It is also found that as the wall superheat is increased, radiation effect becomes more important.

A Prediction Model for Condensation of Zeotropic Refrigerant Mixtures Inside a Horizontal Smooth Tube (수평평활관내의 비공비 혼합냉매의 응축에 대한 예측모델)

  • ;;小山繁
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.13 no.4
    • /
    • pp.262-270
    • /
    • 2001
  • This paper deals with a prediction method for the condensation of ternary refrigerant mixture inside a horizontal smooth tube. Based on some reliable assumptions, the governing equations for the local heat and mass transfer characteristics are derived, and the prediction for the condensation of ternary zeotropic refrigerant mixtures composed of HFC32/HFC125/HFC134a, including R407C, is carried out. The local values of vapor quality, thermodynamic states at bulk vapor, vapor-liquid interface and bulk liquid, mass flux etc. are obtained for a constant wall temperature and a constant wall heat flux conditions, and the effects of the composition of HFC32/HFC125/HFC134a on heat transfer characteristics are examined. The prediction result is also compared with experimental data for condensation of ternary refrigerant mixtures. The predicted wall temperature distribution has a similar trend with experimental data but the predicted local heat transfer coefficients are 20-30% higher than the experimental data.

  • PDF

Evaporation of Water in an Aqueous Lithium Bromide Solution flowing over a Horizontal Tube

  • Kim, Dong-Kwan;Kim, Moo-Hwan
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.9 no.3
    • /
    • pp.57-62
    • /
    • 2001
  • Falling film heat transfer analyses with aqueous lithium bromide solution were performed to investigate the transfer characteristics of the copper tubes. Finned (knurled) tube and a smooth tube were selected as test specimens. Averaged generation fluxes of water and the heat flux were obtained. As the film flow rate of the solution increased, the generation fluxes of water decreased for both tubes due to the fact that the heat transfer resistance increased with the film thickness. The effect of the enlarged surface area at the knurled tube was supposed to be dominant at a small flow rate. The generation fluxes of water increased with the increasing degree of tube wall superheat. Nucleate boiling is supposed to occur at a wall superheat of 20K for a smooth tube, and at 10K for a knurled tube. The increased performance of the knurled tube was supposed to mainly come from the effect of the increased heating surface area.

  • PDF

Heat Transfer Characteristics of Micro-encapsulated Phase-Change-Material Slurry (잠열 마이크로캡슐 슬러리의 열전달 특성)

  • Kim, Myoung-Jun;Park, Ki-Won
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.18 no.6
    • /
    • pp.518-525
    • /
    • 2006
  • The present experiments have been performed for obtaining the melting heat transfer characteristics of micro-encapsulated solid-liquid phase-change material and water mixture slurry flow in a circular tube heated with constant wall heat flux. The phase change material having a low melting point was selected for a domestic cooling system in the present study. The governing parameters were found to be latent heat material concentration, heat flux, and the slurry velocity. The experimental results revealed that the increase of tube wall temperature of latent microcapsule slurry was lower than that of water caused by the heat absorption of fusion.

Experimental Study on Measuring the Intermittency in the Transitional Boundary Layer (천이경계층에서의 간헐도 측정에 관한 실험적 연구)

  • 임효재;안재용;백성구;정명균
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.15 no.1
    • /
    • pp.9-18
    • /
    • 2003
  • An experimental study was performed to investigate the turbulence intermittency measuring methods across the boundary layer in the transition region. A single type hot-wire probe was used to measure instantaneous streamwise velocities in laminar, transitional and turbulent boundary layer To estimate wall shear stresses on the flat plate, near wall mean velocities are applied to the principle of CPM. Distribution of intermittency factor is obtained by dual-slope method and compared to the results of four methods,$\'{u},\;\{U}$, TERA and M-TERA method. In these methods, M-TERA shows a good agreement in the near wall region. However, the result of M-TERA method shows that intermittency factor is underestimated in the outer part and outside of the boundary layer and the dimensional constant of M-TERA method should be changed appropriately depending on measuring point.

Approximate Solution of Absorption Process in an Air-Cooled Vertical Plate Absorber (공냉식 수직평판형 흡수기의 흡수과정에 대한 근사해법)

  • Jeong, E.S.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.6 no.4
    • /
    • pp.453-462
    • /
    • 1994
  • An unsteady quasi one-dimensional model of momentum, heat and mass transfer in a falling film of a vertical plate absorber which is cooled by air was developed using the integral method. Energy conservation of the absorber wall is considered in the model. The model can predict absorption rate, film thickness and mean velocity as well as concentration and temperature profiles. Predictions of steady state temperature and concentration profiles for LiBr/water system for constant wall temperature condition are in good agreement with the two-dimensional finite difference method solutions. Effects of operating conditions, such as convective heat transfer coefficient between the cooling air and the absorber wall, cooling air temperature and film thickness at inlet, on absorption rate of water vapor into LiBr/water solution were shown.

  • PDF

Study on the Turbulent Boundary Layer Disturbed by a Triangular Prism near the Wall (벽근방의 3각주에 의하여 교란받는 난류경계층에 관한 연구)

  • Sim, W.G.;Lee, K.J.;Cho, Y.C.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.3 no.3
    • /
    • pp.161-167
    • /
    • 1991
  • This paper presents the results of some measurement of the fluctuating velocity field in the turbulent boundary layer disturbed by a triangular prism and discusses the discovery of the disturbed boundary layer. A prism of height 8mm was used for experiments. The streamwise location of the prism was fixed at 1200mm downstream from the leading edge and the space between the prism center and the wall was set at three different values, 6, 15 and 33.5mm. The results show that the near-wall region of the disturbed boundary layer recovers original state much more quickly than the outer region. In the case h=6mm the recovery is faster than the other cases. Moreover, it was found that peak of fluctuating velocities moves outwards somewhat rapidly with increasing ${\times}$ mainly due to the turbulent diffusion of the fluctuating velocity.

  • PDF

Two-Dimensional Laminar Natural Convection Heat Transfer with Surface Radiation in a Cavity (캐비티내에서 표면복사를 고려한 2차원 층류 자연대류 열전달)

  • Park, H.Y.;Park, K.W.;Han, C.H.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.4 no.3
    • /
    • pp.217-232
    • /
    • 1992
  • A Numerical study on two-dimensional laminar natural convection with and without surface radiation in fully or partially open square cavity was performed. The cavity has one vertical heated wall facing a vertical opening and two horizontal insulated walls. The pressure boundary condition was applied to the opening instead of the velocity boundary condition. The results of this study showed that the increase of partition length decreased the convective and the radiative Nusselt numbers. It was also found that the increase of wall emissivity decreased the convective Nusselt numbers but increased the radiative Nusselt numbers.

  • PDF