• 제목/요약/키워드: Wall blowing

검색결과 54건 처리시간 0.021초

자유유동 난류강도와 분사비가 터빈 블레이드 선단 막냉각 특성에 미치는 영향 (Effects of Free-Stream Turbulence Intensity and Blowing Ratio on Film Cooling of Turbine Blade Leading Edge)

  • 김성민;김윤제;조형희
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 추계학술대회논문집B
    • /
    • pp.746-751
    • /
    • 2001
  • We used a cylindrical model which simulates turbine blade leading edge to investigate the effects of free-stream turbulence intensity and blowing ratio on film cooling of turbine blade leading edge. Tests are carried out in a low-speed wind tunnel on a cylindrical model with three rows of injection holes. Mainstream Reynolds number based on the cylinder diameter was $7.1\times10^4$. Two types of turbulence grid are used to increase a free-stream turbulence intensity. The effect of coolant blowing ratio was studied for various blowing ratios. For each blowing ratios, wall temperatures around the surface of the test model are measured by thermocouples installed inside the model. Results show that blowing ratios have small effect on spanwise-averaged film effectiveness at high free-stream turbulence intensity. However, an increase in free-stream turbulence intensity enhances significantly spanwise-averaged film effectiveness at low blowing ratio.

  • PDF

고정된 분포 분사/흡입을 통한 채널 유동의 저항 감소 (Drag reduction in channel flow using stationary distributed blowing and suction)

  • 김주현;최해천
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2006년 제4회 한국유체공학학술대회 논문집
    • /
    • pp.195-198
    • /
    • 2006
  • The possibility of skin friction reduction in laminar channel flow is investigated when the flow is subjected to stationary distributed surface blowing and suction. Blowing and suction provided at the channel walls is steady in time but varies as a sine function along the streamwise direction. The skin friction changes depending on the wavelength and amplitude of the actuation. Especially, the skin friction is reduced below that of fully developed laminar flow as the wavelength decreases and amplitude increases. The optimal wavelength of producing minimum skin friction is $\pi/2{\delta}$, where $\delta$ is the channel half-height It is observed that the distributed blowing and suction induces strong negative Reynolds shear stress in the near-wall region at the end of the suction part.

  • PDF

주유동에 수직으로 분사되는 원형 충돌제트의 3차원 유동특성 (Three-Dimensional Flow Characteristics of a Circular Impinging Jet Normally Oriented to Crossflow)

  • 이상우;정철희
    • 대한기계학회논문집B
    • /
    • 제22권12호
    • /
    • pp.1735-1745
    • /
    • 1998
  • Oil-film surface flow visualizations and three-dimensional flow measurements using a straight five-hole probe have been conducted for a circular impinging jet which is normally oriented to the crossflow in a channel. Throughout the experiments, the ratio of channel height to injection hole diameter, H/D, is fixed to be 1.0, and blowing ratio is varied to be 1.0, 2.0, 3.0 and 4.0. From the surface flow visualizations for both top wall(target plate) and bottom wall, impinging jet region on the target plate can be clearly identified, and for the small value of H/D = 1.0, presence of the bottom wall changes the near-hole flow structure, significantly. The three-dimensional flow measurements show that in the dawnstream region of the injection hole, there exist a pair of counter-rotating vortices, called "scarf vortices", and the strength of the vortices strongly depends on the blowing ratio. In addition, a new flow model in the flow symmetry plane has been proposed for H/D = 1.0.

직선슬롯 분사유동에 의한 막냉각의 열유동 특성에 대한 수치적 연구 (Film Cooling Characteristics with Straight-Slot Coolant Injection by Numerical Study)

  • 노석만;손창호;이근식
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2000년도 춘계학술대회논문집B
    • /
    • pp.359-366
    • /
    • 2000
  • A numerical study has been performed for the 2-dimensional film cooling employed in the cooling of hot components such as gas turbines. The flow and heat transfer characteristics are numerically simulated using FLUENT software. Blowing ratios vary from 0.25 to 5.0 and coolant injection angles vary from $15^{\circ}\;to\;60^{\circ}\;in\;15^{\circ}$ increment. The result shows that, for all cases, there exists a blowing ratio which maximizes film cooling effect (measured by the distance from the slot exit to the downstream wall location at which temperature increases to 900 K) for a given injection angle. It is also observed that the film cooling effectiveness decreases when downstream wall is sunk or lifted. The simulation has been performed using both constant properties and temperature dependent variable properties. It is found that the cases with constant properties overestimate the film cooling effect considerably.

  • PDF

Application of the Goore Scheme to Turbulence Control for Drag Reduction(II)-Application to Turbulence Control-

  • 이창훈;김준
    • Journal of Mechanical Science and Technology
    • /
    • 제15권11호
    • /
    • pp.1580-1587
    • /
    • 2001
  • In Part I, we extended the capability of the Goore Scheme for application to multi-dimensional problems and improved convergence performance. In this paper, we apply the improved Goore Scheme to th e control of turbulence for drag reduction. Direct numerical simulations combined with the control scheme are carried out to simulate a controlled turbulent channel flow at low Reynolds number. The wall blowing and suction is applied through the Goore algorithm using the total drag as feedback. An optimum distribution of the wall blowing and suction in terms of the wall-shear stresses in the spanwise and streamwise directions is sought. The best case reduces drag by more than 20 %.

  • PDF

냉각홀 형상 변화에 바른 원형봉 선단의 막냉각 특성 연구 (A Study of Film Cooling of a Cylindrical Leading Edge with Shaped Injection Holes)

  • 김성민;김윤제;조형희
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2002년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.298-303
    • /
    • 2002
  • Dispersion of coolant jets in a film cooling flow field is the result of a highly complex interaction between the film cooling jets and the mainstream. In order to investigate the effect of blowing ratios on the film cooling of turbine blade, cylindrical body model was used. Mainstream Reynolds number based on the cylinder diameter was $7.1{\times}10^4$. The effect of coolant flow rates was studied for blowing ratios of 0.7, 0.9, 1.2 and 1.5, respectively. The temperature distribution of the cylindrical model surface is visualized by infrared thermography (IRT). Results show that the film-cooling performance could be significantly improved by the shaped injection holes. For higher blowing ratio, the spanwise-diffused injection holes are better due to the lower momentum flux away from the wall plane at the hole exit.

  • PDF

Effect of variable viscosity on combined forced and free convection boundary-layer flow over a horizontal plate with blowing or suction

  • Mahmoud, Mostafa A.A.
    • Journal of the Korean Society for Industrial and Applied Mathematics
    • /
    • 제11권1호
    • /
    • pp.57-70
    • /
    • 2007
  • The effects of variable viscosity, blowing or suction on mixed convection flow of a viscous incompressible fluid past a semi-infinite horizontal flat plate aligned parallel to a uniform free stream in the presence of the wall temperature distribution inversely proportional to the square root of the distance from the leading edge have been investigated. The equations governing the flow are transformed into a system of coupled non-linear ordinary differential equations by using similarity variables. The similarity equations have been solved numerically. The effect of the viscosity temperature parameter, the buoyancy parameter and the blowing or suction parameter on the velocity and temperature profiles as well as on the skin-friction coefficient and the Nusselt number are discussed.

  • PDF

계단형 슬롯출구의 높낮이 변화에 따른 2차원 막냉각 특성 (2-Dimensional Film Cooling Characteristics with the Height Variation of a Stepped Slot Exit)

  • 손창호;김태묵;이근식
    • 대한기계학회논문집B
    • /
    • 제29권1호
    • /
    • pp.46-54
    • /
    • 2005
  • Film cooling characteristics has been examined numerically for the height variation of a stepped slot exit. In this study, the upstream wall height of the stepped slot exit varies from -2d (d = slot width) to 3d, blowing ratio ranges from 0.5 to 3, and injection angles are $15^{\circ},\;30^{\circ},\;and\;45^{\circ}$. The results showed that film cooling performance was mainly subjected to the magnitude of recirculation region near the downstream-side slot exit as well as the magnitude and the distribution region of turbulent kinetic energy due to the local velocity and momentum differences between the coolant and the main flow near the slot exit. The up-1d type slot at higher blowing ratios over 2 and the flat type slot at lower blowing ratios below 1 have the best film cooling performances, in case of the injection angles of $30^{\circ},\;and\;45^{\circ}$, respectively. Compared with the other injection angles, in case of the injection angles of $15^{\circ}$, the best film cooling performances was shown in even a higher upstream wall (up-3d) at higher blowing ratio like 3 by the gradual reduction of the coolant velocity which minimizes the local velocity differences between the coolant and the main flow near the slot exit.

채널유동에서 질량분사에 의한 표면유동의 진동 특성 (Oscillation Characteristics of Turbulent Channel Flow with Wall Blowing)

  • 나양;이창진
    • 한국항공우주학회지
    • /
    • 제37권1호
    • /
    • pp.62-68
    • /
    • 2009
  • 하이브리드 로켓 연소에서 발생하는 산화제 난류 유동과 연료의 기화로 인한 분출유동 사이의 상호 간섭은 매우 복잡하고 특별한 유동 간섭을 일으킨다. 이를 연구하기 위하여 연소반응을 제외하고, 산화제의 난류 유동과 연료 벽면에서의 분출 유동을 모사한 채널 유동에 대한 LES 해석을 수행하였다. 고체추진 로켓의 연소 과정에서 관찰되는 현상과 매우 흡사하게 벽면 근처에서 특정주파수로 진동하는 유동 현상이 존재한다는 것을 확인하였고, 산화제와 분출 유동의 간섭에 기인한 유동의 진동현상은 벽면 근처의 매우 얇은 영역에서만 존재하였다. 큰 길이 스케일의 유동현상을 보여주는 압력 섭동장으로부터 채널 내 주유동이 특정 주파수 특성을 갖고 하류로 진행해 가는데, 이는 산화제 유동이 분출유동과 상호작용을 하면서 발생된 전단유동의 특성을 나타낸 것이다. 그러나 하이브리드 로켓 연소실 유동의 진동 특성은 고체 추진 로켓에서 관찰되는 유동 특성과는 달리, 진동의 강도가 벽면에서 온도 구배를 변화시켜 열전달의 향상을 발생시키기에는 충분하지 못한 것으로 보인다. 그러나 벽면 근처에서 특정 주파수 특성을 갖는 유동현상이 존재한다는 사실은 비슷한 크기의 주파수를 갖는 음향 가진과 같은 외부교란이 작용한다면 공진으로 발전할 수 있는 가능성을 의미한다.