• Title/Summary/Keyword: Wall Removal

Search Result 310, Processing Time 0.028 seconds

Successful Removal of a Cardiac Fibroma in Infant (신생아에서 발생한 심장 섬유종의 외과적 치료 -1례 보고-)

  • Kim, Si-Ho;Jo, Beom-Gu;Hong, Yu-Seon
    • Journal of Chest Surgery
    • /
    • v.28 no.5
    • /
    • pp.491-494
    • /
    • 1995
  • A fibroma arising in the right ventricle outflow tract of a 14 month-old infant was successfully removed. The patient was first seen because of shortness of breath and tachycardia. Pertinent clinical and laboratory findings included a grade II/VI systolic murmur, blood pressure of 120/60 mmHg, slight cardiomegaly on chest X-ray, a mass obstructing the outflow tract of the right ventricle on echocardiography and magnetic resonance imaging. On october 30,1992, under cardiopulmonary bypass, a 4cm x 3cm x 3cm tumor was resected from the right ventricular outflow tract, together with a portion of the ventricular wall. Histologically, it was diagnosis as a fibroma. The patient was sent home on the 6th postoperative day following an uneventful recovery form the operation. Although cardiac fibroma is the second most common cardiac tumor in infancy and childhood, it is usually found in the left ventricle and one arising in the right ventricle is considered rare. Although it is a benign tumor, it could produce a severe cardiac dysfunction and even sudden death, depending on its size and location. With the advance in diagnostic techniques and operative management, there is a renewed interest in the early detection and operative removal of these tumors. The case herein presented is the first such case successfully managed and reported in the Korean literature.

  • PDF

Direct membrane filtration of wastewater under very short hydraulic retention time

  • Yoon, Seong-Hoon
    • Advances in environmental research
    • /
    • v.7 no.1
    • /
    • pp.39-52
    • /
    • 2018
  • Direct membrane filtration (DMF) of wastewater has many advantages over conventional biological wastewater treatment processes. DMF is not only compact, but potentially energy efficient due to the lack of biological aeration. It also produces more biosolids that can be used to produce methane gas through anaerobic digestion. Most of ammoniacal nitrogen in wastewater is preserved in effluent and is used as fertilizer when effluent is recycled for irrigation. In this study, a technical feasibility of DMF was explored. Organic and nitrogen removal efficiencies were compared between DMF and membrane bioreactor (MBR). Despite the extremely high F/V ratio, e.g., $14.4kg\;COD/m^3/d$, DMF provided very high COD removal efficiencies at ~93%. Soluble microbial products (SMP) and extracellular polymeric substances (EPS) were less in DMF sludge, but membrane fouling rate was far greater than in MBR. The diversity of microbial community in DMF appeared very narrow based on the morphological observation using optical microscope. On the contrary, highly diverse microbial community was observed in the MBR. Microorganisms tended to form jelly globs and attach on reactor wall in DMF. FT-IR study revealed that the biological globs were structurally supported by feather-like materials made of secondary amines. Confocal laser scanning microscopy (CLSM) study showed microorganisms mainly resided on the external surface of microbial globs rather than the internal spaces.

Structural design concept of the forced-draft sodium-to-air heat exchanger in the decay heat removal system of PGSFR (소듐냉각고속로 잔열제거계통 강제대류 소듐-공기 열교환기의 구조개념 설계)

  • Kim, Nak Hyun;Lee, Sa Yong;Kim, Sung Kyun
    • Transactions of the Korean Society of Pressure Vessels and Piping
    • /
    • v.12 no.1
    • /
    • pp.78-84
    • /
    • 2016
  • The FHX (Forced-draft sodium-to-air Heat Exchanger) employed in the ADHRS (active decay heat removal system) is a shell-and-tube type counter-current flow heat exchanger with M-shape finned-tube arrangement. Liquid sodium flows inside the heat transfer tubes and atmospheric air flows over the finned tubes. The unit is placed in the upper region of the reactor building and has function of dumping the system heat load into the final heat sink, i.e., the atmosphere. Heat is transmitted from the primary cold sodium pool into the ADHRS sodium loop via DHX (decay heat exchanger), and a direct heat exchange occurs between the tube-side sodium and the shell-side air through the FHX tube wall. This paper describes the DHRS and the structural design of the FHX.

Evaluation of Progressive Collapse Resisting Capacity of Tall Buildings

  • Kwon, Kwangho;Park, Seromi;Kim, Jinkoo
    • International Journal of High-Rise Buildings
    • /
    • v.1 no.3
    • /
    • pp.229-235
    • /
    • 2012
  • In this paper the progressive collapse potential of building structures designed for real construction projects were evaluated based on arbitrary column removal scenario using various alternate path methods specified in the GSA guidelines. The analysis model structures are a 22-story reinforced concrete moment frames with core wall building and a 44-story interior concrete core and exterior steel diagrid structure. The progressive collapse resisting capacities of the model structures were evaluated using the linear static, nonlinear static, and nonlinear dynamic analyses. The linear static analysis results showed that progressive collapse occurred in the 22-story model structure when an interior column was removed. However the structure turned out to be safe according to the nonlinear static and dynamic analyses. Similar results were observed in the 44-story diagrid structure. Based on the analysis results, it was concluded that, compared with nonlinear analysis procedures, the linear static method is conservative in the prediction of progressive collapse resisting capacity of building structure based on arbitrary column removal scenario.

Efficiency of the Hybrid-type Air Purifier on Reducing Physical and Biological Aerosol (복합식 공기청정기의 물리적 및 생물학적 입자상 물질의 제거 효과)

  • Kim, Ki-Youn;Kim, Chi-Nyon;Kim, Yoon-Shin;Roh, Young-Man;Lee, Cheol-Min
    • Journal of Environmental Health Sciences
    • /
    • v.32 no.5 s.92
    • /
    • pp.478-484
    • /
    • 2006
  • There was no significant difference in the CADR (Clean Air Delivery Rate) between physical aerosols, NaCl and smoke, and biological aerosols, airborne MS2 virus and P. fluorescens, which implicate that the hybrid-type of air purifier, applying the unipolar ion emission and the radiant catalytic ionization, imposed identical reduction effect on both physical aerosol and bioaerosol. Ventilation decreases the efficiency of air cleaning by unipolar ionization because high ventilation diminishes the particle concentration reduction effect. The particle removal efficiency decreases with increase in the chamber volume because of the augmented ion diffusion and higher ion wall loss rate. Particle size affects the efficiency of air ionization. The efficiency is high for particles with very small diameter because reduction of charge increases with particle size. If there is no increasing supply of ions, the efficiency of air cleaning by unipolar ionization increases with respect to initial concentration of particles because of the large space charge effect at high particle concentration and amplified electric field.

Surgical Treatment of Primary Cardiac Tumor (원발성 심장종양에 대한 외과적 치험)

  • 차경태
    • Journal of Chest Surgery
    • /
    • v.24 no.7
    • /
    • pp.701-711
    • /
    • 1991
  • We experienced 6 cases of primary cardiac tumor, all received operation for removal of tumor. Mean age was 43.8 years-old ranging from 17 years-old to 66 years-old. Five cases were female, one case was male. Five cases were benign, myxoma, all located within left atrium. One case was malignant, angiosarcoma within right atrium. All patient showed cardiac manifestations. One case was in NYHA functional class II, two were in III, three were in IV. Four patients showed constitutional symptoms, but no one showed evidence of embolic phenomenon. All case of myxoma showed cardiomegaly except one malignancy. Only one case was regular sinus rhythm, three were sinus tachycardia 8z two were atrial fibrillation. The most common site of tumor origin was fossa ovalis limbus[four of all]. Two of five myxomas received emergency operation, one patient died postoperatively. Lived four patients showed no evidence of recurrence[mean follow-up, 3,5 years], but one patient has Grade II /IV mitral regurgitation & in OPD follow-up now, One malignant case, 17 years-old cerebral palsy female, was angiosarcoma occupied most of right atrial chamber originated from anterior wall of right atrium, received emergency operation which was removal of mass & reconstruction of right atrium with artificial pericardial patch. This patient died on postoperative 36th day due to persistent LCOS[low cardiac output syndrome] with combined sepsis.

  • PDF

Intraoral Removal of Submental Epidermoid Cyst Extended Inferior to Mylohyoid Muscle (악설골근 하부까지 연장된 이악하부 표피양 낭종의 구강내 적출 1례)

  • Lee, Joon-Kyoo;Cho, Hyu-Chae;Yoon, Tae-Mi;Lim, Sang-Chul
    • Korean Journal of Head & Neck Oncology
    • /
    • v.24 no.2
    • /
    • pp.211-213
    • /
    • 2008
  • Epidermoid cysts located in floor of mouth can be easily removed intraorally. The cysts inferior to mylohyoid muscle have been excised transcervically. However, an intraoral removal of a cyst extended inferior to mylohyoid muscle has not been reported yet. A 20-year-old female visited to the hospital with a cystic mass in submental region. Neck computed tomography revealed a 6.0${\times}$4.3cm sized circumscribed cystic mass in midline of submental area. The cyst lied external to the genioglossal and geniohyoid muscle, extending inferior to mylohyoid muscle. The mass was removed successfully by intraoral approach. It was performed under the exposure by the division of genioglossal and geniohyoid muscle, traction of the cystic wall after aspiration of the cyst, and digital compression externally.

Removal Properties of Nickel and Copper ions by Activated Carbon and Carbon Nanotube (활성탄과 카본나노튜브를 이용한 수용액상의 니켈과 구리 제거 특성)

  • Jung, Yong-Jun
    • Journal of Wetlands Research
    • /
    • v.20 no.4
    • /
    • pp.410-416
    • /
    • 2018
  • This experiment was carried out with the purpose of testing nickel and copper adsorption abilities of multi wall carbon nanotube (MWCNT) and activated carbon. In the acidic condition, only MWCNT was effective for removing nickel and copper ion in the aqueous phase while activated carbon rarely remove them. The MWCNT and heavy metals adsorption reaction followed pseudo-first order kinetic. When the initial pH value was neutral (pH=7), nickel was rapidly removed by MWCNT and activated carbon in 4 hr (99.02 %, 80.30 %). Also, copper ion was rapidly removed by both adsorbents in 4 hr when the initial pH was 7 (100 %, 99.73 %). Increasing of adsorbent dosages affect the pH evolution and heavy metal ions removal (0 ~ 99%). Also, oxidation pretreatment enhanced the adsorption efficiency of MWCNT.

Parasitic Leiomyoma with Lymphatic Dilatation in Trocar Port-Site of Abdominal Wall: A Case Report (트로카 삽입 부위에 생긴 림프관 확장을 동반한 기생 평활근종: 증례 보고)

  • Gayoung Jeon;Seo Young Park
    • Journal of the Korean Society of Radiology
    • /
    • v.84 no.1
    • /
    • pp.280-285
    • /
    • 2023
  • Uterine leiomyoma is the most common benign pelvic tumor in female and being symptomatic is an indication for surgical removal. As laparoscopic surgery has been developed, some cases related to parasitic leiomyomas in the port site have been reported. A 40-year-old female who a history of previous laparoscopic surgery to remove uterine myoma 2 years ago visited in outpatient clinic of general surgery with palpable mass in left lower abdomen. Contrast enhanced abdomen CT and pelvis MRI were done to evaluate the mass. It was diagnosed parasitic leiomyoma in pathologic study after surgical removal and parasitic leiomyoma should be considered when patient visited presenting abdominal mass with the history of laparoscopic myomectomy.

Numerical analysis of the coupled heat and mass transfer phenomena in a metal hydride hydrogen storage reactor(I) - Model development of analyzation for hydrogen absorption reaction using the $LaNi_5$ bed (금속수소화물 수소저장 용기 내부의 열 및 물질전달 현상에 대한 수치적 연구(I) - $LaNi_5$ 베드를 이용한 수소 흡장반응 해석 모델 개발)

  • Nam, Jinmoo;Ju, Hyunchul
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2010.06a
    • /
    • pp.225.1-225.1
    • /
    • 2010
  • Within recent years attention has been focused on the method of hydrogen storage using metal hydride reactor due to its high energy density, durability, safety and low operating pressure. In this paper, a numerical study is carried out to investigate the coupled heat and mass transfer process for absorption in a cylindrical metal hydride hydrogen storage reactor using a newly developed model. The simulation results demonstrate the evolution of temperature, equilibrium pressure, H/M atomic ratio and velocity distribution as time goes by. Initially, hydrogen is absorbed earlier from near the wall which sets the cooling boundary condition owing to that absorption process is exothermic reaction. Temperature increases rapidly in entire region at the beginning stage due to the initial low temperature and enough metal surface for hydrogen absorption. As time goes by, temperature decreases slowly from the wall region due to the better heat removal. Equilibrium pressure distribution appears similarly with temperature distribution for reasons of the function of temperature. This work provides a detailed insight into the mechanism and corresponding physicochemical phenomena in the reactor during the hydrogen absorption process.

  • PDF