• 제목/요약/키워드: Wall Pressure

검색결과 2,438건 처리시간 0.028초

Atomization Improvement of a Liquid Jet with Wall Impingement and its Application to a Jet Engine Atomizer

  • Shiga, Seiichi
    • 한국분무공학회지
    • /
    • 제11권3호
    • /
    • pp.176-189
    • /
    • 2006
  • In the present study, capability of improving the liquid atomization of a high-speed liquid jet by using wall impingement is explored, and its application to a jet engine atomize. is demonstrated. Water is injected from a thin nozzle. The liquid jet impinges on a wall positioned close to the nozzle exit, forming a liquid film. The liquid film velocity and the SMD were measured with PDA and LDSA, respectively. It was shown that the SMD of the droplets was determined by the liquid film velocity and impingement angle, regardless of the injection pressure or impingement wall diameter. When the liquid film velocity was smaller than 300m/s, a smaller SMD was obtained, compared with a simple free jet. This wall impingement technique was applied to a conventional air-blasting nozzle for jet engines. A real-size air-blasting burner was installed in a test rig in which three thin holes were made to accommodate liquid injection toward the intermediate ring, as an impingement wall. The air velocity was varied from 41 to 92m/s, and the liquid injection pressure was varied from 0.5 to 7.5 MPa. Combining wall impinging pressure atomization with gas-blasting produces remarkable improvement in atomization, which is contributed by the droplets produced in the pressure atomization mode. Comparison with the previous formulation for conventional gas-blasting atomization is also made, and the effectiveness of utilizing pressure atomization with wall impingement is shown.

  • PDF

유한요소해석에 기초한 감육곡관 손상압력 평가 모델 개발 (Development of Failure Pressure Evaluation Model for Local Wall-Thinned Elbows Based on Finite Element Analysis)

  • 김진원;박종선
    • 대한기계학회논문집A
    • /
    • 제32권12호
    • /
    • pp.1063-1071
    • /
    • 2008
  • This paper provides a failure pressure evaluation model for local wall-thinned elbows. In this study, parametric finite element analyses are performed on the elbows containing local wall-thinning defect at their intrados and extrados, and the failure pressures are obtained from the analysis results by applying a local failure criterion that was validated by real-scale pipe tests. An evaluation model including the effects of thinning depth, length, circumferential angle, thinning location, and elbow geometries on the failure pressure is derived based on the evaluated failure pressures. The proposed model agrees well with the results of finite element analyses and reasonably estimates the dependence of failure pressure on the wall-thinning dimensions and elbow geometries. Also, the comparison with experimental data demonstrates that the proposed evaluation model can accurately predict the failure pressure of local wall-thinned elbows.

실배관 파열실험을 통한 국부감육 곡관 손상압력 평가 (Failure Pressure Evaluation of Local Wall-Thinned Elbows by Real-scale Burst Tests)

  • 김진원;박치용;이성호
    • 대한기계학회논문집A
    • /
    • 제31권10호
    • /
    • pp.1017-1024
    • /
    • 2007
  • This study performed a series of burst tests at ambient temperature using real-scale elbow specimen containing a local wall-thinning defect at it's intrados or extrados and evaluated failure pressure of locally wall-thinned elbows. In the experiment, a 90-degree 100A, Sch. 80 standard elbow was employed, and various wall-thinning geometries, such as length, depth, and circumferential angle, were considered. From the results of experiment, the dependences of failure pressure of wall-thinned elbows on the defect geometries and locations were investigated. In addition, the reliability of existing models was examined by comparing the tests data with the results predicted from existing failure pressure evaluation models for locally wall-thinned elbow.

Navier-Stokes Analysis of Pitching Delta Wings in a Wind Tunnel

  • Lee, Yung-Gyo
    • International Journal of Aeronautical and Space Sciences
    • /
    • 제2권2호
    • /
    • pp.28-38
    • /
    • 2001
  • A numerical method for the assessment and correction of tunnel wall interference effects on forced-oscillation testing is presented. The method is based on the wall pressure signature method using computed wall pressure distributions. The wall pressure field is computed using unsteady three-dimensional full Navier-Stokes solver for a 70-degree pitching delta wing in a wind tunnel. Approximately-factorized alternate direction implicit (AF-ADI) scheme is advanced in time by solving block tri-diagonal matrices. The algebraic Baldwin-Lomax turbulence, model is included to simulate the turbulent flow effect. Also, dual time sub-iteration with, local, time stepping is implemented to improve the convergence. The computed wall pressure field is then imposed as boundary conditions for Euler re-simulation to obtain the interference flow field. The static computation shows good agreement with experiments. The dynamic computation demonstrates reasonable physical phenomena with a good convergence history. The effects of the tunnel wall in upwash and blockage are analyzed using the computed interference flow field for several reduced frequencies and amplitudes. The corrected results by pressure signature method agree well with the results of free air conditions.

  • PDF

원형수직구의 흙막이 벽체에 작용하는 주동토압 (Active Earth Pressure Acting on the Cylindrical Retaining Wall of a Shaft)

  • 천병식;신영완
    • 한국지반환경공학회 논문집
    • /
    • 제7권4호
    • /
    • pp.15-24
    • /
    • 2006
  • 원형 오픈 케이슨과 원형 수직구에 설치된 흙막이 벽에 작용하는 토압은, 벽체의 변위와 응력해방으로 인한 수평 및 연직 아칭효과로 인하여, 평면 변형조건에서의 옹벽에 작용하는 토압보다는 작은 토압이 발생한다. 원형벽체에 작용하는 토압분포를 조사하기 위해서, 건조한 모래지반에서 깊이에 따른 벽체변형이 균등한 조건의 모형실험을 실시하였다. 벽체 변위, 벽면 마찰, 벽체 형상비 등을 조절할 수 있는 모형 실험 장치가 개발되었고, 모형실험을 통하여 원통형 벽체에 작용하는 토압에 대한 다양한 인자의 영향이 분석되었다.

  • PDF

연직보강재의 토압경감 효과 (An Experimental Study on the Earth Pressure Effect of Vertical Reinforcements)

  • 문경선;이상덕
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 1999년도 가을 학술발표회 논문집
    • /
    • pp.457-464
    • /
    • 1999
  • The active earth pressure on the retaining wall is reduced by 3-Dimensional effects of the ground. Therefore, the test was focused on reducing the earth pressure on the retaining wall by inserting the vertical reinforcement in the backfill ground to develope the 3-Dimensional effects. Model tests in sand were peformed to measure the 3-Dimensional effects of the vertical reinforcement on the active earth pressure and its distribution and results were compared with the theories. The size of the vertical reinforcement, the geometry of the backfill space, and the wall friction of vertical reinforcement were varied. It was observed that the active earth pressure and its distribution on the underground structure were affected by the size of the vertical reforcements and wall friction.

  • PDF

내부 감육 배관의 손상압력 평가 모델 개발 (Development of Failure Pressure Evaluation Model for Internally Well Thinned Piping Components)

  • 나만균;박치용;김진원
    • 대한기계학회논문집A
    • /
    • 제29권7호
    • /
    • pp.947-954
    • /
    • 2005
  • The purpose of this study is to develop failure pressure evaluation models, which are applicable to straight pipes and elbows containing an internally wall thinning defect induced by flow-accelerated-corrosion (FAC). In this study, thus, three dimensional finite element (FE) analyses are performed to investigate the dependences of failure pressure of internally wall thinned pipe on the defect shape, the pipe geometry, and the defect location and bend radius of elbow. Also, the existing failure pressure assessment models for externally wall thinned pipes are examined. Based on these, the new models for assessing failure pressure of piping components with an internally wall thinning defect are proposed. Comparison of failure pressure, predicted by proposed models, with FE analysis result shows good agreement regardless of pipe type, defect shape, and defect location and bend radius.

사질토에 시공된 앵커토류벽의 토압분포에 관한 연구 (Earth Pressuroes of Tieback Walls in Sand)

  • 김낙경
    • 한국지반공학회지:지반
    • /
    • 제14권5호
    • /
    • pp.17-28
    • /
    • 1998
  • 사질토 지반에 시공된 앵커토류벽의 설 설계하중을 결정함으로서 토류벽의 설계에 있어 가장 기본적이고 필수적인 요소택에 있다. 앵커토류벽에 작용하는 토압분포는 배성, 흙의 아칭 효과 등에 따라 크게 변하 토류벽에 작용하는 토압분포의 가정은 크 한 직사각형 분포의 겉보기토압이 적용되 본 연구에서는 실물크기의 앵커토류 Function을 이용하여 토류벽에 작용하는 토압분포를 시공단계별로 산정하여 설계에 이용되는 토압 분포와 비교하였다. 또한 앵커 토류벽의 설계에 적용되는 Rankine 토압분포를 이용하는 Canadian Geotechnical Society 방법과 TerBaghi와 Peck이 제안한 겉보기토압을 이용한 설계방법을 현장시험 결과와 비교하여 분석하였다. 본 연구의 결론으로는 앵커 설계하중, 최대 휨모멘트의 산정 방법에 있어 30% 정도의 안전율을 고려할 때 Tereaghi 와 Peck 토압을 이용한 단순보 힌지법이 Rankine의 주동토압보다 적합하다는 사실을 입증하였다.

  • PDF

사각 감육을 고려한 중수로 공급자관 파열압력 평가 (Evaluation of the Burst Pressure for Rectangular Wall-thinning of CANDU Feeder Pipe)

  • 김광수;김민규;조두호;정재준
    • 한국압력기기공학회 논문집
    • /
    • 제17권1호
    • /
    • pp.28-35
    • /
    • 2021
  • The flow accelerated corrosion (FAC) is one of significant aging and degradation mechanism and can affect structural integrity of CANDU feeder pipes. Pipe burst can occur under normal operation pressure (min. 10 MPa) if wall-thinning of the feeder pipe due to FAC is accumulated. Previous studies considered simple shapes of feeder pipe with local wall-thinning in order to conservatively assess structural integrity of wall-thinned feeder pipe. In this paper, a new FE model is developed, having an actual shape of the feeder pipe (double bent) as well as the actual wall-thinning shape and location based on the in-service inspection result. Then, the burst pressure assessment of the wall-thinned feeder pipe is performed using lower bound limit load analysis considering elastic-perfectly plastic material. In addition, an improved formulation to predict the burst pressure of the wall-thinned feeder pipe is presented and the safety margin is compared with an existing assessment method.

내압을 받는 내/외부 국부 감육 곡관의 파손거동 (Damage Behavior of Elbow Pipe with Inner or Outer Local Wall Thinning under Internal Pressure)

  • 김수영;남기우
    • 동력기계공학회지
    • /
    • 제18권5호
    • /
    • pp.66-73
    • /
    • 2014
  • This study was considered to occur the local wall thinning at elbow which is flowing the steam and high-pressure water of high-temperature. The angle of elbow is ${\Theta}=45^{\circ}$ and $67.545^{\circ}$. The damage behaviors of inner or outer wall thinning elbow under internal pressure were calculated by FEA(finite element analysis). We compared the simulated results by FEA with experimental data. The FEA results are as follows: In the FEA results of three types of wall thinning ratio, the circumferential and longitudinal stresses show the similar values regardless of the angle of elbow, respectively. The circumferential strain was greater at elbow of small angle, but the longitudinal strain was nearly same. The FEM stress of outer wall thinning elbow was slightly higher than that of the inner wall thinning elbow, and strain was also slightly higher. In the experiments, the circumferential strain was increased with the increase in the internal pressure, and increased rapidly on about 0.2% of strain. The longitudinal strain was small. The strain at break was much smaller than 0.2%. In the relation between pressure and eroded ratio, the criteria that can be used safely under operating pressure and design pressure were obtained. The results of FEA were in relatively good agreement with those of the experiment.