• 제목/요약/키워드: Wall Function

검색결과 948건 처리시간 0.03초

Microstructural Characteristics of the Ordered and Disordered Leaves in Citrus junos Sieb.

  • Park, Min-Hee;Boo, Hee-Ock;Kim, Hong-Sub;Lee, Sook-Young
    • Plant Resources
    • /
    • 제3권3호
    • /
    • pp.163-172
    • /
    • 2000
  • We compared microstructural features of the ordered cell and disordered leaves in Citrus junos Sieb. by electron microscopy. In the cell of the ordered leaves, many chloroplasts and large vacuoles were particularly observed. Also a lot of vessel, companion cell and big nucleus were presented in vascular bundle regions. The mitochondria and the other organelles were interspersed among the chloroplasts in a thin, peripheral layer of cytoplasm. The chloroplast possessed typical grana and intergranal lamellae, numerous starch grains and a few small osmophilic globules. Besides, microbodies were closely associated with the mitochondria and the chloroplast. The process of the formation of the secondary cell wall from primary cell wall was observed the vessel elements, the tonoplast wall and the secondary cell wall. It was observed that the oil sac with the unique perfume distributed the adjacent cell wall. In the cell of disordered leaves, the all of the organelles were thrust toward the cell wall due to the fusion of vacuoles in the cells. It was observed that a lot of the very small particles spreaded in the cytoplasm. The loss of unique perfume of the leaves was resulted in the destruction of the oil sac. Also, there was not observed grana, lamellae, starch and osmophillic globules in the chloroplast. The small distributed organelles was not observed but the elongation of the cell wall was proceed no longer. Therefore, the plasma membrane diverged from the cell wall. All of organelles in the cell had poor function and deformation. A massive vacuole was fulfilled in single cell and the vacuole contains a lot of large and small particles. The organelles were presented on the side of the cell wall according to the enlargement of vacuole and they were observed to be breakdown.

  • PDF

고유동 콘크리트의 거푸집 측압 측정에 관한 실험적 연구 (An Experimental Study on the Measuring Lateral Formwork Pressure Controlled by Super-Workable Fresh Concrete)

  • 이준구;박광수;김한중;배수호
    • 한국농공학회:학술대회논문집
    • /
    • 한국농공학회 1998년도 학술발표회 발표논문집
    • /
    • pp.142-145
    • /
    • 1998
  • The purpose of this study is to estimate lateral formwork pressure controlled by super-workable fresh concrete using prototype structrues such as, tall wall, retaining wall, and beam quantitativly. As a result of this experiment, a function which can be used to design a formwork system and to predict formwork pressure curve is formulated.

  • PDF

비선형 k-$\varepsilon$ 난류모델에 따른 정사각형 덕트내 난류유동 수치해석(8권1호 게재논문중 그림정정) (Simulation of Turbulent Flow in a Square Duct with Nonlinear k-$\varepsilon$ Models)

  • 명현국
    • 한국전산유체공학회지
    • /
    • 제8권2호
    • /
    • pp.57-63
    • /
    • 2003
  • Two nonlinear κ-ε models with the wall function method are applied to the fully developed turbulent flow in a square duct. Typical predicted quantities such as axial and secondary velocities, turbulent kinetic energy and Reynolds stresses are compared in details both qualitatively and quantitatively with each other. A nonlinear κ-ε model with the wall function method capable of predicting accurately duct flows involving turbulence-driven secondary motion is presented in the present paper. The nonlinear κ-ε model of Shih et al.[1] adopted in a commercial code is found to be unable to predict accurately duct flows with the prediction level of secondary flows one order less than that of the experiment.

인쇄형 열교환기 입구부의 최적설계 (Shape Optimization of Inlet Part of a PCHE)

  • 구경완;이상문;김광용
    • 한국유체기계학회 논문집
    • /
    • 제16권2호
    • /
    • pp.35-41
    • /
    • 2013
  • Inlet part of a printed circuit heat exchanger has been optimized by using three-dimensional Reynolds-Averaged Navier-Stokes analysis and surrogate modeling techniques. Kriging model has been used as the surrogate model. The objective function for the optimization has been defined as a linear combination of uniformity of mass flow rate and the pressure loss with a weighting factor. For the optimization, the angle of the inlet plenum wall, radius of curvature of the inlet plenum wall, and width of the inlet pipes have been selected as design variables. Twenty six design points are obtained by Latin Hypercube Sampling in design space. Through the optimization, considerable improvement in the objective function has been obtained in comparison with the reference design of PCHE.

게이트 심근 SPECT : 도약을 위한 준비 (Pulling Bowstring of Gated Myocardial SPECT)

  • 범희승
    • 대한핵의학회지
    • /
    • 제32권5호
    • /
    • pp.433-435
    • /
    • 1998
  • Recent progress of technology permits us to assess ventricular function and wall motion as well as myocardial perfusion using electrocardiographic gated myocardial perfusion single photon emission computed tomography (GM-SPECT). It is interesting that echocardiography and magnetic resonance imaging are moving in the same direction with the use of contrast medium to assess myocardial perfusion. A valid fundamental basis for a new technology is essential for a successful competition. Lee et al. report in this issue the reproducibility of serial measurement of left ventricular function including systolic wall thickening using a novel statistical method. It has important implications such as nitroglycerin or dobutamine application during GM-SPECT. The field of nuclear cardiology must continue to strive toward more sophisticated but straightforward evaluation of cardiac diseases.

  • PDF

로터리 버너의 축류형 팬 주위 유동특성 연구 (A Study on the Flow Characteristics Around an Axial Fan of Rotary Burner)

  • 고동국;조대진;윤석주
    • 한국분무공학회지
    • /
    • 제8권1호
    • /
    • pp.1-8
    • /
    • 2003
  • The flow analysis of the axial fan of rotary burner was performed by SIMPLE(Semi Implicit Method for Pressure Linked Equations) algorithm and finite volume mothod performed in the case of 3-D, incompressible, turbulent flow. In this study, the coordinate transformation was adapted for the complex geometry of axial fan, and the standard $k-{\varepsilon}$ model and wall function method were used for analysis of turbulent flow. Multi-block grid system was used for flow field and divided into four domains such as the inlet, outlet, flow field of rotating vane, and tip clearance. Fan rotation was simulated by rotational motion using MRF(Multiple Rotating Reference Frame) in steady, incompressible state flow.

  • PDF

비선형 ${\kappa}-{\epsilon}$ 난류모델에 따른 정사각형 덕트내 난류유동 예측 (Prediction of Turbulent Flow in a Square Duct with Nonlinear ${\kappa}-{\epsilon}$ Models)

  • 명현국
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2003년도 춘계학술대회
    • /
    • pp.1980-1985
    • /
    • 2003
  • Two nonlinear ${\kappa}-{\epsilon}$ models with the wall function method are applied to the fully developed turbulent flow in a square duct. Typical predicted quantities such as axial and secondary velocities, turbulent kinetic energy and Reynolds stresses are compared in details both qualitatively and quantitatively with each other. A nonlinear ${\kappa}-{\epsilon}$ model with the wall function method capable of predicting accurately duct flows involving turbulence-driven secondary motion is presented in the present paper. The nonlinear ${\kappa}-{\epsilon}$ model adopted in a commercial code is found to be unable to predict accurately duct flows with the prediction level of secondary flows one order less than that of the experiment.

  • PDF

심근 관류 SOECT의 새로운 방법 (New Imaging Techniques in Myocardial Perfusion SPECT)

  • 이동수
    • 대한핵의학회지
    • /
    • 제32권1호
    • /
    • pp.1-9
    • /
    • 1998
  • Gated myocardial SPECT and attenuation correction gave birth to new insights into the pathophysiology of ischemic myocardial perfusion and function in clinical routine practice. Gated myocardial Tc-99m-compound SPECT improved diagnostic accuracy of coronary artery disease and enabled us to observe motion and thickening of myocardial walls as well as myocardial perfusion at the same time. Quantitative and qualitative assessment of myocardial performance and perfusion let us to understand the myocardial physiology in ischemia and infarction. In every patient who underwent gated perfusion SPECT, we will find ejection fraction, left ventricular volumes and regional wall motion. There are hopes to use gated TI-201 SPECT for the same purpose and to use gated SPECT for evaluation of wall motion and thickening at stress or immediate post-stress. Attenuation correction could improve diagnostic accuracy mainly by increasing normalcy ratio or performance of non-expert physicians. Both gated methods and attenuation correction improved specificity of non-expert physicians in diagnosing patients with moderate pretest likelihood. New imaging techniques will fill the desire of cardiologists to examine function and perfusion, and possibly metabolism in their clinical routine practice.

  • PDF

Development of Viscous Boundary Conditions in an Immersed Cartesian Grid Framework

  • Lee, Jae-Doo
    • Journal of Ship and Ocean Technology
    • /
    • 제10권3호
    • /
    • pp.1-16
    • /
    • 2006
  • Despite the high cost of memory and CPU time required to resolve the boundary layer, a viscous unstructured grid solver has many advantages over a structured grid solver such as the convenience in automated grid generation and vortex capturing by solution adaption. In present study, an unstructured Cartesian grid solver is developed on the basis of the existing Euler solver, NASCART-GT. Instead of cut-cell approach, immersed boundary approach is applied with ghost cell boundary condition, which can be easily applied to a moving grid solver. The standard $k-{\varepsilon}$ model by Launder and Spalding is employed for the turbulence modeling, and a new wall function approach is devised for the unstructured Cartesian grid solver. Developed approach is validated and the efficiency of the developed boundary condition is tested in 2-D flow field around a flat plate, NACA0012 airfoil, and axisymmetric hemispheroid.

EPS의 압축성을 이용한 콘크리트 옹벽 시스템 연구 (Retaining Wall System Using the Compressible Inclusion Function of EPS)

  • 김진만;김호비;조삼덕;주태성;최봉혁
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2001년도 봄 학술발표회 논문집
    • /
    • pp.411-418
    • /
    • 2001
  • The last 30 years have been significant worldwide growth in the use of EPS as a lightweight fill material. This paper analyzes the compressible inclusion function of EPS which can results in reduction of static earth pressure by accomodating the movement of retained soil. A series of model tests was conducted to evaluate the reduction of static earth pressure using EPS inclusion and determine the optimum stiffness of EPS, Also, field test was conducted to evaluate the reduction of static earth pressure using EPS inclusion. Based on field test it is found that the magnitude of static earth pressure was reduced about 20% compared with theoretical active earth pressure.

  • PDF