• 제목/요약/키워드: Wall Element

검색결과 1,246건 처리시간 0.035초

유한요소법을 이용한 방폭벽 프로파일에 대한 응력해석 (Stress Analysis on the Profile of Blast Wall with Finite Element Method)

  • 김병탁;고성위;김광희
    • 한국기계가공학회지
    • /
    • 제11권3호
    • /
    • pp.130-137
    • /
    • 2012
  • Blast walls are integral structures at the typical offshore topside module to provide safety barriers for personnel and critical equipment against any blast loading and hydrocarbon explosions. The blast wall structures are usually configured with stainless steel. It can be referred as the good mechanical properties of the stainless steel against blast load, which features the characteristics of significant energy absorption and ductility. In this study, the proposed designs of corrugated panel are examined in order to determine the best design which satisfies the design criteria. The criteria on maximum deflection and stress are used to decide the best design. The effect of inclined angle of profile on deformation characteristics of blast wall is also performed. The numerical study was performed by using NX Nastran 7.5.

유한요소해석을 이용한 국부 감육배관에 대한 응력집중계수 제시 (Finite Element Based Stress Concentration Factors for Pipes with Local Wall Thinning)

  • 손범구;김윤재;김영진
    • 대한기계학회논문집A
    • /
    • 제28권7호
    • /
    • pp.1014-1020
    • /
    • 2004
  • The present work complies the elastic stress concentration factor for a pipe with local wall thinning, based on detailed three-dimensional elastic FE analysis. To cover practically interesting cases, a wide range of pipe and defect geometries are considered, and both internal pressure and global bending are considered. Resulting values of stress concentration factors are tabulated for practical use, and the effect of relevant parameters such as pipe and defect geometries on stress concentration factors are discussed. The present results would provide valuable information to estimate fatigue damage of the pipe with local wall thinning under high cycle fatigue.

부분보강 엄지말뚝을 이용한 굴착시공방법의 수치해석적 타당성검토 (A Numerical Analysis of Excavation Method Using Partially Reinforced Soldier Pile)

  • 김준석;김주용;이승래
    • 한국지반공학회논문집
    • /
    • 제16권2호
    • /
    • pp.5-12
    • /
    • 2000
  • The hazard of excavation may be very high until a supporting system is completely installed. In this paper, an excavation method which uses partially reinforced soldier pile($\square$-shape) inserted by a short length steel bar was proposed and simulated by the finite element method. The reinforcing steel bar is moved down along the stage of excavation to reinforce the stiffness of the supporting system. The result of analysis showed that the risk of failure by bending moment or shear stress could be significantly reduced by the reinforcing effect of the steel bar. The proposed method could be applied to the strut-supporting wall or the diaphragm wall.

  • PDF

감육이 존재하고 내압과 굽힘하중의 복합하중을 받는 T 분기관의 한계하중 (Limit Loads for Piping Branch Junctions with Local Wall-thinning under Internal Pressure and In-plane Bending)

  • 한재준;이국희;김윤재;이성호;박치용
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2008년도 추계학술대회A
    • /
    • pp.299-304
    • /
    • 2008
  • This paper presents plastic limit loads of piping branch junctions with local wall thinning under combined pressure and in-plane bending, based on systematic three-dimensional finite element limit analyses using elastic-perfectly plastic materials. An ideal branch junction without weld or reinforcement around the intersection is considered with two locations of wall thinning; one in the run pipe, and the other in the branch pipe. Based on FE results, effects of thinning geometries on plastic limit moments are quantified and simple approximations of plastic limit loads are proposed.

  • PDF

Seismic behavioral fragility curves of concrete cylindrical water tanks for sloshing, cracking, and wall bending

  • Yazdabad, Mohammad;Behnamfar, Farhad;Samani, Abdolreza K.
    • Earthquakes and Structures
    • /
    • 제14권2호
    • /
    • pp.95-102
    • /
    • 2018
  • Seismic fragility curves of concrete cylindrical tanks are determined using the finite element method. Vulnerabilities including sloshing of contents, tensile cracking and compression failure of the tank wall due to bending are accounted for. Effects of wall flexibility, fixity at the base, and height-diameter ratio on the response are investigated. Tall, medium and squat tanks are considered. The dynamic analysis is implemented using the horizontal components of consistent earthquakes. The study shows that generally taller tanks are more vulnerable to all of the failure modes considered. Among the modes of failure, the bending capacity of wall was shown to be the critical design parameter.

Low Attenuation Waveguide for Structural Health Monitoring with Leaky Surface Waves

  • Bezdek, M.;Joseph, K.;Tittmann, B.R.
    • 비파괴검사학회지
    • /
    • 제32권3호
    • /
    • pp.241-262
    • /
    • 2012
  • Some applications require structural health monitoring in inaccessible components. This paper presents a technique useful for Structural Health Monitoring of double wall structures, such as double wall steam pipes and double wall pressure vessels separated from an ultrasonic transducer by three layers. Detection has been demonstrated at distances in excess of one meter for a fixed transducer. The case presented here is for one of the layers, the middle layer, being a fluid. For certain transducer configurations the wave propagating in the fluid is a wave with low velocity and attenuation. The paper presents a model based on wave theory and finite element simulation; the experimental set-up and observations, and comparison between theory and experiment. The results provide a description of the technique, understanding of the phenomenon and its possible applications in Structural Health Monitoring.

Lessons from the analysis of a 3-D concrete shear wall

  • Vecchio, F.J.
    • Structural Engineering and Mechanics
    • /
    • 제6권4호
    • /
    • pp.439-455
    • /
    • 1998
  • A three-dimensional static nonlinear finite element analysis was performed on the NUPEC large-scale flanged shear wall, which was the subject of an international study program. Details of the constitutive models and analysis procedures used are provided, and the results of the analysis are presented and discussed. The analytical results are compared to the experimentally observed behaviour, and reasonable correlation is observed. Deficiencies in the modelling are identified. In addition, a parametric study is undertaken to investigate factors and mechanisms influencing both the observed behaviour and the calculated response. Finally, a cyclic load analysis of the wall is described and discussed. The paper serves to point out aspects in modelling that are critical to both producing realistic results, and correctly interpreting those results.

수평하중을 받는 전단벽 아웃리거 시스템의 거동특성 평가 (Structural Behavior Characteristics Evaluation of Shear Wall Outrigger System Subject to Horizontal Loads)

  • 김호수;이한주;홍석일;임영도
    • 한국공간구조학회:학술대회논문집
    • /
    • 한국공간구조학회 2006년도 춘계 학술발표회 논문집 제3권1호(통권3호)
    • /
    • pp.110-117
    • /
    • 2006
  • This study presents an effective stiffness-based optimal technique to consider floor rigid diaphragm action and a technique to evaluate the structural behavior characteristics and efficiency for tall shear wall outrigger system subject to horizontal loads. To this end, isoparametric plane stress element with rotational stiffness is used for shear wall element and stiffness gradient is calculated. Also, the approximation concept to solve effectively the large scaled problems, member grouping technique and resizing technique are considered. To verify the effectiveness and usefulness of this technique, the efficient evaluation method for three types of 50 story model with core and outrigger system is presented.

  • PDF

A simplified method for free vibration analysis of wall-frames considering soil structure interaction

  • Kara, Dondu;Bozdogan, Kanat Burak;Keskin, Erdinc
    • Structural Engineering and Mechanics
    • /
    • 제77권1호
    • /
    • pp.37-46
    • /
    • 2021
  • In this study, a method for free vibration analysis of wall-frame systems built on weak soil is proposed. In the development of the method, the wall-frame system that constitutes the superstructure was modeled as flexural-shear beam. In the study, it is accepted that the soil layers are isotropic, homogeneous and elastic, and the waves are only vertical propagating shear waves. Based on this assumption, the soil layer below is modeled as an equivalent shear beam. Then the differential equation system that represented the behavior of the whole system was written for both regions in a separate way. Natural periods were obtained by solving the differential equations by employing boundary conditions. At the end of the study, two examples were solved and the suitability of the proposed method to the Finite Element Method was evaluated.

지하주차장과 아파트 연결 벽체의 균열 원인 분석 및 저감방안 연구 (A Study on the Cause and Reduction of Cracks in the Wall Connecting the Underground Parking Lot and the Apartment)

  • 심학보;박순전
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2020년도 봄 학술논문 발표대회
    • /
    • pp.161-162
    • /
    • 2020
  • Cracks are caused by drying shrinkage between the upper part of the underground parking lot and the apartment wall. As a result of the investigation, the distance between the apartment and the apartment is more than 45m, and the top slab of the underground parking lot is usually flat when there is not with steps. Therefore, the crack occurs more when the underground parking lot is a PC slab than a RC slab. In this study, the reduction of cracks was conducted by extending the slab, expanding the beam size, increasing the wall thickness, and installing a delay joint on slab. In each case, a finite element analysis was performed to examine the crack reduction method.

  • PDF