• 제목/요약/키워드: Wake Flow Field

검색결과 237건 처리시간 0.029초

수직형 소형풍력터빈의 비정상 익력 평가 (Analysis of Unsteady Blade Forces in a Vertical-axis Small Wind Turbine)

  • 이상문;김철규;전석윤;알사지드;장춘만
    • 한국수소및신에너지학회논문집
    • /
    • 제29권2호
    • /
    • pp.197-204
    • /
    • 2018
  • In the present study, unsteady flow analysis has been conducted to investigate the blade forces and wake flow around a hybrid street-lamp having a vertical-axis small wind turbine and a photovoltaic panel. Uniform velocities of 3, 5 and 7 m/s are applied as inlet boundary condition. Relatively large vortex shedding is formed at the wake region of the photovoltaic panel, which affects the increase of blade torque and wake flow downstream of the wind turbine. It is found that blade force has a good relation to the variation of the angle of attack with the rotation of turbine blades. Variations in the torque on the turbine blade over time create a cyclic fluctuation, which can be a source of turbine vibration and noise. Unsteady fluctuation of blade forces is also analyzed to understand the nature of the vibration of a small wind turbine over time. The detailed flow field inside the turbine blades is analyzed and discussed.

인공어초 주변의 흐름장에 관한 수치해석 (Numerical Analysis of the Flow Field around Artificial Reefs)

  • 정칠훈;김헌태
    • 한국수산과학회지
    • /
    • 제40권1호
    • /
    • pp.31-38
    • /
    • 2007
  • This study investigated the fluid force acting on an artificial reef and the scour pattern at the bottom of the artificial reef in a steady-flow field using the finite difference method (Flow-3D). The structure was tetragonal in shape, like similar objects found in nature. The numerical analysis showed that the hydrodynamic characteristics and incipient scouring pattern matched natural phenomena. The velocity distribution around the tetragon was symmetric and wake occurred inside the tetragon and behind the bottom of the tetragon. The length of the recirculation flow behind the tetragon for each velocity was about 4-5 cm and the magnitude of the recirculation flow inside the tetragon generally increased with the Reynolds' number, although it decreased slightly for Reynolds' numbers from 11,000 to 12,000. In addition, the total fluid force acting on the tetragon increased with the inflow velocity, although the increment was smaller when the velocity exceed 18 cm/sec. The incipient pattern for the scouring of sediment matched the natural phenomenon.

배연탈질설비의 성능향상을 휘한 가스혼합에 관한 연구 (A Study on the Flue Gas Mixing for the Performance Improvement of De-NOx plant)

  • 류병남
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제23권4호
    • /
    • pp.462-472
    • /
    • 1999
  • De-NOx facility using Selective Catalytic Reduction method is the most widely applied one that removes NOx from flue gas emitted from combustion facility such as boiler for power generation engine incinerator etc. Reductant $NH_3\;or\;NH_4OH$ is sprayed into flue gas to convert NOx into $H_2O$ and $N_2.$ Good mixing between flue gas and $NH_3$ is the most important factor to increase reduction in catalytic layer and to reduce unreacted NH3 slip. Therefore the development of mixer device for mixing effect is one of the important part for SCR facility. Objectives of this study are to investigate the relation between flow and concentration field by observation at the wake of delta-wing type mixer. At the first stage qualitative measurement of flow field is conducted by flow visualization using laser light sheet in lab. scale wind tunnel. Also we have conducted the quantitative analysis by comparing flow field measurement using LDV with numerical simulation. On the basis of qualitative and quantitative analysis we investigate the dis-tribution of flow and concentration in flow model facility. The results of an experimental and compu-tational examination of the vortex structures shed from delta wing type vortex generator having $40^{\circ}$ angle of attack are presented, The effects of vortex structure on the gas mixing is discussed, too.

  • PDF

Effects of wind direction on the flight trajectories of roof sheathing panels under high winds

  • Kordi, Bahareh;Traczuk, Gabriel;Kopp, Gregory A.
    • Wind and Structures
    • /
    • 제13권2호
    • /
    • pp.145-167
    • /
    • 2010
  • By using the 'failure' model approach, the effects of wind direction on the flight of sheathing panels from the roof of a model house in extreme winds was investigated. A complex relationship between the initial conditions, failure velocities, flight trajectories and speeds was observed. It was found that the local flow field above the roof and in the wake of the house have important effects on the flight of the panels. For example, when the initial panel location is oblique to the wind direction and in the region of separated flow near the roof edge, the panels do not fly from the roof since the resultant aerodynamic forces are small, even though the pressure coefficients at failure are high. For panels that do fly, wake effects from the building are a source of significant variation of flight trajectories and speeds. It was observed that the horizontal velocities of the panels span a range of about 20% - 95% of the roof height gust speed at failure. Numerical calculations assuming uniform, smooth flow appear to be useful for determining panel speeds; in particular, using the mean roof height, 3 sec gust speed provides a useful upper bound for determining panel speeds for the configuration examined. However, there are significant challenges for estimating trajectories using this method.

축대칭 몰수체의 유효반류 추정 (Prediction of the Effective Wake of an Axisymmetric Body)

  • 김기섭;문일성;안종우;김건도;박영하;이창섭
    • 대한조선학회논문집
    • /
    • 제56권5호
    • /
    • pp.410-417
    • /
    • 2019
  • An axisymmetric submerged body(L=5.6m, Diam=0.53m) is installed in Large Cavitation Tunnel (LCT) of KRISO and the nominal and total velocities without and with the propeller in operation, respectively, are measured using Laser Doppler Velocimeter (LDV). The flow field is nearly axisymmetric except the wake of the supporting strut, and is considered ideal to study the hydrodynamic interaction between the propeller and the oncoming axisymmetric sheared flow. The measured velocity data are then provided to compute the propeller-induced velocity to get the effective velocity, which is defined by subtracting the propeller-induced velocity from the total velocity. We adopted, in computing the induced velocity, two different methods including the vortex lattice method and the vortex tube actuator model to evaluate the resultant effective velocity distribution. To secure a fundamental base of experimental data necessary for the research on the effective wake, we measured the drag of the submerged body, the nominal and total velocity distributions at various axial locations for three different tunnel water speeds.

프로즌 로터 기법을 이용한 부분흡입형 터빈 수치해석 (Numerical Flow Analysis of a Partial Admission Turbine Using a Frozen Rotor Method)

  • 노준구;정은환;이은석;김진한
    • 한국유체기계학회 논문집
    • /
    • 제7권6호
    • /
    • pp.15-20
    • /
    • 2004
  • Numerical analysis of the partial admission turbine in the KARI turbopump has been performed. Flow field of the partial admission turbine is intrinsically unsteady and three dimensional. To avoid heavy computational efforts, the frozen rotor method is adopted in computation and compared with the mixing plane approach. The frozen rotor method can represent the variation of a flow field along the circumferential direction of rotor blades, which have the different relative positions to the nozzle with one another. It also illustrates the wake loss mechanism starting from the lip of a nozzle, which is not captured in the mixing plane method. The frozen rotor method has proven to be an efficient tool for the design of a partial admission turbine.

구 주위의 유동으로 인해 발생하는 유동 소음의 특성 (Characteristics of Flow-Induced Noise around a Sphere)

  • 윤기웅;최해천
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2003년도 추계학술대회
    • /
    • pp.810-815
    • /
    • 2003
  • Flow-induced noise propagated from flow over a sphere is numerically investigated for laminar flow at Re = 300 and 425, and for turbulent flow at Re = 3700 and $10^4$, where the Reynolds number is based on the freestream velocity and the sphere diameter. The numerical method used for obtaining the flow over a sphere is based on an immersed boundary method in a cylindrical coordinate system. The Curle’s solutions of the Lighthill’s acoustic analogy with and without the far-field and compact-source approximation are used in order to investigate the noise field from flow over a sphere. Since the drag and lift forces change irregularly in time at Re = 425, 3700 and $10^{4}$, the noise propagates in a complicated manner. At Re = 300, 425 and $10^{4}$, the noise from dipole sources is much larger than that from quadrupole sources. On the other hand, at Re = 3700, the quadrupole source becomes dominant. The temporal variation of the flow-induced noise around a sphere is obtained at some observation points, which shows that the peak frequency corresponds to the Strouhal number associated with the wake instability.

  • PDF

축류터빈 동익 내부의 누설유동에 관한 수치해석 (Numerical Analysis of Tip Leakage Flows in Axial Flow Turbine Rotors)

  • 정희택
    • 동력기계공학회지
    • /
    • 제9권1호
    • /
    • pp.23-29
    • /
    • 2005
  • Numerical analysis of three-dimensional viscous flow-fields in the turbine rotor passages was carried out to investigate flow physics including the interaction between secondary vortices, tip leakage vortex, and the rotor wake. The blade tip geometry was accurately modeled adopting the embedded H grid system. An explicit four-stage Runge-Kutta scheme was used for the time integration of both the mean flow and turbulence equations. The computational results for the entire turbine rotor flows, particularly the tip clearance flow and the secondary flows, were interpreted and compared with the experimental data from the Penn State turbine stage. The predictions for major features of the flow field have been found to be in good agreement with the experimental data.

  • PDF

SVA Potsdam 프로펠러 단독 및 캐비테이션 성능 수치해석 (Numerical Analysis of Non-Cavitating and Cavitating Performance of a SVA Potsdam Propeller)

  • 김제인;박일룡;김기섭;안종우
    • 대한조선학회논문집
    • /
    • 제54권3호
    • /
    • pp.215-226
    • /
    • 2017
  • This paper presents numerical results of the performance of a marin propeller in cavitating and non-cavitating flow conditions. The geometry and experimental validation data of the propeller are provided in Potsdam Propeller Test Case(PPTC) in the framework of the second International Symposium on Marine Propulsors 2011(SMP'11) workshop. The PPTC includes open water tests, velocity field measurements and cavitation tests. The present numerical analysis was carried out by using the Reynolds averaged Navier-Stokes(RANS) method on a wall-resolved grid ensuring a y+=1, where the SST k-${\omega}$ model was mainly used for turbulence closure. The influence of the turbulence model was investigated in the prediction of the wake field under a non-cavitating flow condition. The propeller tip vortex flows in both cavitating and non-cavitating conditions were captured through adaptation of additional grids. For the cavitation flows at three operation points, Schnerr-Sauer's cavitation model was used with a Volume-Of Fluid(VOF) approach to capture the two-phase flows. The present numerical results for the propeller wake and cavitation predictions including the open water performance showed a qualitatively reasonable agreement with the model test results.

Across-wind excitation mechanism for interference of twin tall buildings in tandem arrangement

  • Zu, G.B.;Lam, K.M.
    • Wind and Structures
    • /
    • 제26권6호
    • /
    • pp.397-413
    • /
    • 2018
  • Excitation mechanism of interference effect between two tall buildings is investigated with wind tunnel experiments. Synchronized building surface pressure and flow field measurements by particle image velocimetry (PIV) are conducted to explore the relationship between the disturbed wind flow field and the consequent wind load modification for twin buildings in tandem. This reveals evident excitation mechanisms for the fluctuating across-wind loads on the buildings. For small distance (X/D < 3) between two buildings, the disturbed flow pattern of impaired vortex shedding is observed and the fluctuating across-wind load on the downstream building decreases. For larger distance ($X/D{\geq}3$), strong correlation between the across-wind load of the downstream building and the oscillation of the wake of the upstream building is found. By further analysis with conditional sampling and phase-averaged techniques, the coherent flow structures in the building gap are clearly observed and the wake oscillation of the upstream building is confirmed to be the reason of the magnified across-wind force on the downstream building. For efficient PIV measurement, the experiments use a square-section high-rise building model with geometry scale smaller than the usual value. Interference factors for all three components of wind loads on the building models being surrounded by another identical building with various configurations are measured and compared with those from previous studies made at large geometry scale. The results support that for interference effect between buildings with sharp corners, the length scale effect plays a minor role provided that the minimum Reynolds number requirement is met.