• 제목/요약/키워드: WAMS

검색결과 19건 처리시간 0.022초

RTDS 기반의 345kV, 115모선 전력계통 동적 데이터 감시를 위한 인프라 구축 (Establishing Infra-Structure in order to Monitor the Dynamic Data of 345kV, 115 buses Wide Area Power System based on RTDS)

  • 김상태;이원우;신정훈;남수철;김태균;최미화
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.240-242
    • /
    • 2006
  • In this paper, Infra system that can monitor and analyze the wide area power system phenomena based on RTDS is established. This system provide users with understandable viewer for monitoring power system as well as management system for RTDS simulation model cases. The tests are studied based on 345kV, 115 buses korean system using RTDS.

  • PDF

스마트그리드를 위한 자율형 상태관측기 연구 (The Study on Autonomous State Estimator for Smart Grid)

  • 박종찬;이세인
    • 전기학회논문지P
    • /
    • 제60권1호
    • /
    • pp.32-36
    • /
    • 2011
  • In this study, authors have proposed the autonomous state estimation which has been composed with IEC61850, GPS time synchronization and objective model design concept. The proposed method is able to supervise/correct measurement and communication error from SCADA. The major advantages of the proposed autonomous state estimation are that it is possible to evaluate integrity of data measured and transferred from SCADA, to reduce human intervention and to expense national-size applications such as EMS (Energy Management System), WAMS (Wide Area Monitoring System) or WAPS (Wide Area Protection System). This study addresses the issues related to the operation of the smart grid and proposes a new automated approach to achieve this goal. Through applying the proposed system to IEEE 14-bus test electric system, we prove the possibility of the proposed idea.

Synchro-Phasor 기반의 Smart WAMAC 인프라 아키텍쳐 설계 (Designing of Smart WAMAC Infra Architecture based on Synchro-Phasor)

  • 김지영;우덕제;김상태;최미화;김용광
    • 전기학회논문지
    • /
    • 제59권9호
    • /
    • pp.1549-1559
    • /
    • 2010
  • Modern power system is operated and managed in closed network environment with treating a great variety of data, and requirement of real time power system data is more increasing. However, it is difficult for operators to fast evaluate the condition of power system using only isolation network system such as SCADA or EMS regarding unexpecting situations occurring. Recent technology achievement in areas of distributed computing, networking high speed communications and digital control as well as the availability of accurate GPS time source are rapidly becoming the enabling factors for the development of a new generation of real time power grid monitoring tools. In this paper, architecture of WAMAC which is the wide area monitoring and control system not only to control but also to monitoring in real time is proposed and the plan of integration interface with legacy system such as EMS for providing power system analysis base data effectively is suggested.

광역 전력계통 감시를 위한 상위 Master System 설계 (Design and Development of Master System for Monitoring Wide Area Power System)

  • 김상태;이정현;김지영;이동철;문영환;김태현;윤재영;김동준;이병준;한상욱;남해곤;심관식;이승재;진보건
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.243-245
    • /
    • 2006
  • In this paper, the master system of Wide Area Monitoring System in order to prevent reaching a fault influence toward power system is proposed. This system has three real time algorithms and a on-line one using i-piu transfer data and provides operators with various understandable monitoring viewers in HMI based on raw data and algorithm results.

  • PDF

문헌 조사를 통한 국내 선박 수리 작업자들의 석면 노출 특성 분석 (Ship Repair Workers' Exposure to Asbestos by a Systematic Review in Korea)

  • 최상준;권효정;곽수경
    • 대한안전경영과학회지
    • /
    • 제14권3호
    • /
    • pp.135-141
    • /
    • 2012
  • This study was conducted to evaluate the characteristics of exposure to asbestos for ship repair workers in Korea by a systematic review. The number of articles studying asbestos exposure levels from ship repair workplaces was found to be 4. All asbestos concentration reported as either geometric mean and geometric standard deviation or ranges were transformed to arithmetic mean to estimate exposure level. In addition, weighted arithmetic means(WAMs) were calculated by weighing of the different number of samples. The WAM concentrations were 2.746 f/cc during asbestos dismantling work, 0.034 f/cc before asbestos dismantling work and 0.065 f/cc after working respectively. The maximum airborne concentration of asbestos during asbestos removal work was 7.02 f/cc which was 70 times higher than the occupational exposure limit of Korea, 0.1 f/cc. This study recommends that retrospective exposure to asbestos based on various ship types and operations should be assessed.

Coordinated Control Strategy for Power Systems with Wind Farms Integration Based on Phase-plane Trajectory

  • Zeng, Yuan;Yang, Yang;Qin, Chao;Chang, Jiangtao;Zhang, Jian;Tu, Jingzhe
    • Journal of Electrical Engineering and Technology
    • /
    • 제13권1호
    • /
    • pp.20-29
    • /
    • 2018
  • The dynamic characteristics of power systems become more and more complex because of the integration of large-scale wind power, which needs appropriate control strategy to guarantee stable operation. With wide area measurement system(WAMS) creating conditions for realizing realt-ime transient stability analysis, a new coordinated control strategy for power system transient stability control based on phase-plane trajectory was proposed. When the outputs of the wind farms change, the proposed control method is capable of selecting optimal generators to balance the deviation of wind power and prevent transient instability. With small disturbance on the base operating point, the coordinated sensitivity of each synchronous generator is obtained. Then the priority matrix can be formed by sorting the coordinated sensitivity in ascending order. Based on the real-time output change of wind farm, coordinated generators can be selected to accomplish the coordinated control with wind farms. The results in New England 10-genrator 39-bus system validate the effectiveness and superiority of the proposed coordinated control strategy.

Power System Enhanced Monitoring through Strategic PMU Placement Considering Degree of Criticality of Buses

  • Singh, Ajeet Kumar;Fozdar, Manoj
    • Journal of Electrical Engineering and Technology
    • /
    • 제13권5호
    • /
    • pp.1769-1777
    • /
    • 2018
  • This paper proposes a method for optimal placement of Phasor Measurement Units (PMUs) considering system configuration and its attributes during the planning phase of PMU deployment. Each bus of the system is assessed on four diverse attributes; namely, redundancy of measurements, rotor angle and frequency monitoring of generator buses, reactive power deficiency, and maximum loading limit under transmission line outage contingency, and a consolidated 'degree of criticality' is determined using Technique for Order of Preference by Similarity to Ideal Solution (TOPSIS). The major contribution of the proposed work is the development of modified objective function which incorporates values of the degree of criticality of buses. The problem is formulated as maximization of the aggregate degree of criticality of the system. The resultant PMU configuration extends complete observability of the system and majority of the PMUs are located on critical buses. As budgetary restrictions on utilities may not allow installation PMUs even at optimal locations in a single phase, multi-horizon deployment of PMUs is also addressed. The proposed approach is tested on IEEE 14-bus, IEEE 30-bus, New England (NE) 39-bus, IEEE 57-bus and IEEE 118-bus systems and compared with some existing methods.

Complete and Incomplete Observability Analysis by Optimal PMU Placement Techniques of a Network

  • Krishna, K. Bala;Rosalina, K. Mercy;Ramaraj, N.
    • Journal of Electrical Engineering and Technology
    • /
    • 제13권5호
    • /
    • pp.1814-1820
    • /
    • 2018
  • State estimation of power systems has become vital in recent days of power operation and control. SCADA and EMS are intended for the state estimation and to communicate and monitor the systems which are operated at specified time. Although various methods are used we can achieve the better results by using PMU technique. On placing the PMU, operating time is reduced and making the performance reliable. In this paper, PMU placement is done in two ways. Those are 'optimal technique with pruning operation' and 'depth of unobservability' considering incomplete and complete observability of a network. By Depth of Unobservability Number of PMUs are reduced to attain Observability of the network. Proposed methods are tested on IEEE 14, 30, 57, SR-system and Sub systems (1, 2) with bus size of 270 and 444 buses. Along with achieving complete observability analysis, single PMU loss condition is also achieved.

${\ll}$영추(靈樞).논용(論勇)${\gg}$ 에 대(對)한 연구(硏究)

  • 이남구;장대원
    • 대한한의학원전학회지
    • /
    • 제13권1호
    • /
    • pp.328-344
    • /
    • 2000
  • YoungChu NonYong(靈樞 論勇)seems to be named as such by its explanation in detail about the brave man who can and the coward who cannot stand pain respectively. In the first chapter, it is considered that the factors of diseases are dependent upon the state of skin and flash. In the second chapter, it is put about the problem of standing pain and not. In the third chapter, about the causes of resulting in brave or unbrave man. And in the fourth chapter, about drunken frenzy(酒悖). More concretely speaking, in the first chapter, it is explained that the factors of pathogenesis are related closely with the state of skin and flash, so to speak, though the outer factors which can arouse diseases should exist, the sensitivity of skin and flash which are the first defense tissue in human body, is more important factor. Undoubtedly, the environmental factors existing in physical nature which surrounds human life, have influenced upon human health, especially in ancient times. But, this chapter exhibits some reflections that ultimately the inner conditions of human body decide the attack of diseases. However, this chapter may have some corruptions for it reveals the contents which are not fit with the headline. In the second chapter, it is written that the sensitivity to pain is not only dependent upon the character of bravery but also upon the thickness of skin, the strength of flesh and the speed of response. In this we evidence that the ancient people had the idea that human pain-feeling is more dependent upon the degree of development of sensory neuron of physical body than one's character of bravery. In the third chapter, ti is described that the differences of physical development mainly influence the differences of the degree of mental bravery. In the fourth chapter, the drunken frenzy is explained. The implication is that as civilization has been growing, the drinking culture has made both in dividual and social health affair. The alcohol has the function of pleasing mind improving the quality of human life but it can also destroy both human body and mind when abused. About the harms like this, this part wams by the examples of drunken man's abnormal behaviors.

  • PDF