• 제목/요약/키워드: W-beam

검색결과 1,046건 처리시간 0.032초

열린 균열이 있는 보의 효율적 모델링 방법 (An Efficient Modeling Method for Open Cracked Beam Structures)

  • Kim, M. D.;Park, S. W.;S. W. Hong;Lee, C. W.
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2002년도 추계학술대회논문초록집
    • /
    • pp.372.2-372
    • /
    • 2002
  • This paper presents an efficient modeling method fur open cracked beam structures. An equivalent bending spring model is introduced to represent the structural weakening effect in the presence of open cracks. The proposed method adopts the exact dynamic element method (EDEM) to avoid the difficulty and numerical errors in association with re-meshing the structure. The proposed method is rigorously compared with a commercial finite element code. (omitted)

  • PDF

PPLN 비선형 결정과 이중통과법을 이용한 DOFA 시스템에서 증폭된 연속발진형 파장가변 적외선 레이저광의 제 2고조파 발생 (Double-pass Second Harmonics Generation of Tunable CW Infrared Laser Beam of DOFA System in Periodically Poled LiNbO3)

  • 유길상;조재흥;고광훈;임권;정도영
    • 한국광학회지
    • /
    • 제19권3호
    • /
    • pp.229-236
    • /
    • 2008
  • 주기적으로 분극 반전된 비선형 결정 중에 하나인 PPLN(Periodically Poled MgO(5%) doped Lithium Niobate)과 수 W급의 고출력 연속발진형 파장가변 적외선 레이저 시스템인 DOFA(Diode Laser Oscillator & Fiber Amplifier) 시스템을 이용하여, 이 결정에서 펌핑광을 한번 통과시키는 단일통과와 두 번 통과시키는 이중통과에서의 효율적인 제2고조파 발생 조건을 실험적으로 구하였다. 단일통과에서는 최적의 위상정합온도 $108.9^{\circ}C$에서 최대 출력 2.45 W의 적외선(파장 = 1070 nm) 펌핑광을 사용하여 최대 245 mW의 녹색광원(파장 = 535 nm)인 제 2고조파를 만들었고, 이때의 주파수 변환 효율은 10%였다. 또한 제 2고조파 발생의 효율을 증가시키기 위해서 되 반사용 오목거울과 위상보정을 위한 쐐기유리판을 이용하여 이중통과의 제2고조파 발생장치를 구성하였다. 이때 최적의 위상정합온도 $108.5^{\circ}C$에서 최대 출력 2.45 W의 적외선(파장 = 1070 nm) 펌핑광을 사용하여 최대 383 mW의 녹색광원(파장 = 535 nm)인 제 2고조파를 만들었다. 이때의 변환 효율은 15.6%로써 단일통과에서의 제 2고조파 발생 효율보다 크게 증가함을 확인하였다.

에너지 흡수 장치를 부착한 트라이빔 가드레일 시스템의 거동 (Performance of Thrie-Beam Guardrail System withe Impact Attenuator)

  • 고만기;김기동
    • 한국강구조학회 논문집
    • /
    • 제13권4호
    • /
    • pp.381-393
    • /
    • 2001
  • 최근 교통상항은 교통량의 급격한 증가와 차종의 다양성에 그 특성이 있다. 우리나라에서 가장 많이 사용되고 있는 W형 보를 사용한 가드레일은 $14ton-60Km/h-15^{\circ}$ 의 충돌조건에 대하여 구조물의 강성이 충분치 못한 반면에, 보다 현실적인 충돌속도에 대하여 소형차의 탑승자 안전을 충족시키지 못하는 것으로 나타났다. 대형차에 대응하기 위하여 구조물의 강성을 증가시키는 일과 소형차에 대하여 탑승자의 안전을 도모(에너지 소산)해야하는 두 가지의 서로 상반된 목표를 달성하기 위하여, 두께 3.2mm의 강판을 이용한 보의 고무로 만든 충격 흡수재를 이용한 트라이-빔 가드레일 시스템을 고안하여 정적 실내실험, 컴퓨터 시뮬레이션 및 실차 충돌실험을 통하여 거동 및 성능을 조사하였다. 2%의 무게증가로 기존의 W형 보에 비하여 보의 높이가 약 100mm 증가된 트라이-빔(450mm)가드레일 시스템은 범퍼 높이가 다른 다양한 차종에 보다 좋은 수용능력을 보였고 강성과 충격흡수 능력 또한 W-보 가드레일 시스템에 비하여 크게 향상되었다. 그리고 실차 충돌실험을 실시한 결과 NCHRP 350의 Test 3-10 충돌시 성능 요건을 만족시켰다.

  • PDF

대면적 전자빔 폴리싱 공정 시 발생하는 온도 분포 유한요소해석 연구 (Finite Element Analysis of Large-Electron-Beam Polishing-Induced Temperature Distribution)

  • 김지수;김진석;강은구;이석우;박형욱
    • 한국생산제조학회지
    • /
    • 제22권6호
    • /
    • pp.931-936
    • /
    • 2013
  • Recently, the use of large-electron-beam polishing for polishing complex metal surfaces has been proposed. In this study, the temperature induced by a large electron beam was predicted using the heat transfer theory. A finite element (FE) model of a continuous wave (CW) electron beam was constructed assuming Gaussian distribution. The temperature distribution and melting depth of an SUS304 sample were predicted by changing electron-beam polishing process parameters such as energy density and beam velocity. The results obtained using the developed FE model were compared with experimental results for verifying the melting depth prediction capability of the developed FE model.

GafChromic RTQA Film을 이용한 광역학적 치료용 레이저의 선질 측정 (GafChromic RTQA Film Dosimetry for Laser Beam with Photodynamic Therapy)

  • 이병구;임현수;네클라 커나르
    • 대한의용생체공학회:의공학회지
    • /
    • 제34권2호
    • /
    • pp.73-79
    • /
    • 2013
  • Purpose: The purposes of this study were to measure the dose distribution of Photodynamic therapy(PDT) laser with 635 nm wavelength using GafChromic film. Method & Result: We made each output 300 J by changing mW and sec using the laser beam radiation mode such as C.W(Continuous Wave) mode, Pulse mode and Burst Pulse mode and measured the does at 0 mm and 5 mm of distance from optic fiber catheter end to the film, and at 5 mm distance by changing the angle of the end of the optic fiber catheter as $0^{\circ}$ and $0.5^{\circ}$. The radiated film was scanned and OD(Optical Density) was compared. And two-dimensional isodose curves were obtained and the consistency of shapes was compared. It was confirmed that there was consistency between optic density and the dose radiated on the film when we radiated GafChromic film by changing distance and angle of 300 J output in each radiation mode coordinating mW and sec. Conclusion: In this study, we could identify the stability according to changes in laser beam modes, changes in output according to distance, changes in uniformity according to angle, and beam profiles using GafChromic film, and we could also get two-dimensional isodose curve. It was found that small change in the distance and angle that is made when optic fiber catheter was contacted on the treatment area did not make big effects on the output of beam and the uniformity of dose, and it was also found that GafChromic film could be utilized for the purpose of QA of PDT laser beam.

Effects of Material Anisotropy on Ultrasonic Beam Propagation: Diffraction and Beam Skew

  • Jeong, Hyun-Jo;Schmerr, W.
    • 비파괴검사학회지
    • /
    • 제26권3호
    • /
    • pp.198-205
    • /
    • 2006
  • The necessity of nondestructively inspecting austenitic steels, fiber-reinforced composites, and other inherently anisotropic materials has stimulated considerable interest in developing beam models for anisotropic media. The properties of slowness surface playa key role in the beam models based on the paraxial approximation. In this paper, we apply a modular multi-Gaussian beam (MMGB) model to study the effects of material anisotropy on ultrasonic beam profile. It is shown that the anisotropic effects of beam skew and excess beam divergence enter into the MMGB model through parameters defining the slope and curvature of the slowness surface. The overall beam profile is found when the quasilongitudinal(qL) beam propagates in the symmetry plane of transversely isotropic austenitic steels. Simulation results are presented to illustrate the effects of these parameters on ultrasonic beam diffraction and beam skew. The MMGB calculations are also checked by comparing the anisotropy factor and beam skew angle with other analytical solutions.