• Title/Summary/Keyword: Vt. C

Search Result 57, Processing Time 0.025 seconds

Comparison of Water Potential Parameters in Aster scaber and Synurus deltoides Leaves Obtained from P-V Curves (P-V 곡선법에 의한 참취와 수리취의 수분포텐셜 비교)

  • Lee, Kyeong-Cheol;Jeon, Seong-Ryeol;Han, Sang-Sup
    • Korean Journal of Plant Resources
    • /
    • v.24 no.4
    • /
    • pp.413-418
    • /
    • 2011
  • This study was carried out to establish a proper cultivation site and diagnose the drought-tolerance of Aster scaber and Synurus deltoides leaves by using Pressure-volume curves. In order to measure pressure-volume (P-V) curves, Aster scaber and Synurus deltoides were cut off above ground part and the tip of the cutting were placed in water, which was covered with a plastic bag. Samples were kept overnight (about 12 hours) in darkness at room temperature (20~25$^{\circ}C$) to achieve maximal turgor (full saturation). The pressure in the chamber was gradually increased from 0.3MPa to 1.8MPa by nitrogen gas. After measured, leaf samples were dried at 80$^{\circ}C$ for 48 hours and dry weight of each samples were determined. The result of the original bulk osmotic potential at maximum turgor ${\Psi}^{sat}_o$ sat was lower -0.8 MPa in Aster scaber leaves than -0.7 MPa Synurus deltoides leaves. Also the osmotic potential at incipient plasmolysis ${\Psi}^{tlp}_o$ in Aster scaber leave was -0.9 MPa. In contrast, the value of maximum bulk modulus of elasticity $E_{max}$ of Aster scaber leaves were approximately two folds higher than that of Synurus deltoides leaves. The values of the relative water content at incipient plasmolysis $RWC^{tlp}$ are all above 90% showing that the function of osmoregulation is somewhat better, and Vo/DW, Vt/DW, Ns/DW of Synurus deltoides leaves were approximately 1~2 times higher than that of Aster scaber leaves. Thus, responses to water relations of Aster scaber and Synurus deltoides such as ${\Psi}^{sat}_o$, ${\Psi}^{tlp}_o$, $E_{max}$, ${\Psi}_{P,max}$, $RWC^{tl}$ were shown that the Aster scaber leaves was slightly higher drought-tolerance than Synurus deltoides leaves. However, in both of Aster scaber and Synurus deltoides, occurring incipient plasmolysis at the high water content, have a relatively lower drought-tolerance property indicating that growth of these plants are cultivated appropriate in high moisture soil sites.

백색 LED증착용 MOCVD 유도가열 장치에서 가스 inlet위치에 따른 기판의 온도 균일도 측정

  • Hong, Gwang-Gi;Yang, Won-Gyun;Ju, Jeong-Hun
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2010.08a
    • /
    • pp.115-115
    • /
    • 2010
  • 고휘도 고효율 백색 LED (lighting emitting diode)가 차세대 조명광원으로 급부상하고 있다. 백색 LED를 생산하기 위한 공정에서 MOCVD (유기금속화학증착)장비를 이용한 에피웨이퍼공정은 에피층과 기판의 격자상수 차이와 열팽창계수차이로 인하여 생성되는 에피결함의 문제로 기판과 GaN 박막층 사이에 완충작용을 해줄 수 있는 버퍼층 (Buffer layer)을 만든다. 그 위에 InGaN/GaN MQW (Multi Quantum Well)공정을 하여 고휘도 고효율 백색 LED를 구현 할 수 있다. 이 공정에서 기판의 온도가 불균일해지면 wafer 파장 균일도가 나빠지므로 백색 LED의 yield가 떨어진다. 균일한 기판 온도를 갖기 위한 조건으로 기판과 induction heater의 간격, 가스의 흐름, 기판의 회전, 유도가열코일의 디자인 등이 장비의 설계 요소이다. 본 연구에서는 유도가열방식의 유도가열히터를 이용하여 기판과 히터의 간격에 차이에 따른 기판 균일도 측정했고, 회전에 의한 기판의 온도분포와 자기장분포의 실험적 결과를 상용화 유체역학 코드인 CFD-ACE+의 모델링 결과와 비교 했다. 또한 가스의 inlet위치에 따른 기판의 온도 균일도를 측정하였다. 본 연구에서 사용된 가열원은 유도가열히터 (Viewtong, VT-180C2)를 사용했고, 가열된 흑연판 표면의 온도를 2차원적으로 평가하기 위하여 적외선 열화상 카메라 (Fluke, Ti-10)를 이용하여 온도를 측정했다. 와전류에 의한 흑연판의 가열 현상을 누출 전계의 분포로 확인하기 위하여 Tektronix사의 A6302 probe와 TM502A amplifier를 사용했다. 흑연판 위에 1 cm2 간격으로 211곳에서 유도 전류를 측정했다. 유도전류는 벡터양이므로 $E{\theta}$를 측정했으며, 이때의 측정 방향은 흑연판의 원주방향이다. 또한 자기장에 의한 유도전류의 분포를 확인하기 위하여 KANETEC사의 TM-501을 이용하여 흑연판 중심으로부터 10 mm 간격으로 자기장을 측정 했다. 저항 가열 히터를 통하여 대류에 의한 온도 균일도를 평가한 결과 gap이 3 mm일때, 평균 온도 $166.5^{\circ}C$에서 불균일도 6.5%를 얻었으며, 회전에 의한 온도 균일도 측정 결과는 2.5 RPM일 때 평균온도 $163^{\circ}C$에서 5.5%의 불균일도를 확인했다. 또한 CFD-ACE+를 이용한 모델링 결과 자기장의 분포는 중심이 높은 분포를 나타냄을 확인했고, 기판의 온도분포는 중심으로부터 55 mm되는 곳에서 300 W/m3로 가장 높은 분포를 나타냈다. 가스 inlet 위치를 흑연판 중심으로 수직, 수평 방향으로 흘려주었을 때의 불균일도는 각각 10.5%, 8.0%로 수평 방향으로 가스를 흘려주었을 때 2.5% 온도 균일도 향상을 확인했다.

  • PDF

SVM Classifier for the Detection of Ventricular Fibrillation (SVM 분류기를 통한 심실세동 검출)

  • Song, Mi-Hye;Lee, Jeon;Cho, Sung-Pil;Lee, Kyoung-Joung
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.42 no.5 s.305
    • /
    • pp.27-34
    • /
    • 2005
  • Ventricular fibrillation(VF) is generally caused by chaotic behavior of electrical propagation in heart and may result in sudden cardiac death. In this study, we proposed a ventricular fibrillation detection algorithm based on support vector machine classifier, which could offer benefits to reduce the teaming costs as well as good classification performance. Before the extraction of input features, raw ECG signal was applied to preprocessing procedures, as like wavelet transform based bandpass filtering, R peak detection and segment assignment for feature extraction. We selected input features which of some are related to the rhythm information and of others are related to wavelet coefficients that could describe the morphology of ventricular fibrillation well. Parameters for SVM classifier, C and ${\alpha}$, were chosen as 10 and 1 respectively by trial and error experiments. Each average performance for normal sinus rhythm ventricular tachycardia and VF, was 98.39%, 96.92% and 99.88%. And, when the VF detection performance of SVM classifier was compared to that of multi-layer perceptron and fuzzy inference methods, it showed similar or higher values. Consequently, we could find that the proposed input features and SVM classifier would one of the most useful algorithm for VF detection.

Cost-Benefit Analysis on Marine Transportation Safety Facility Using CVM(Contingent Valuation Method) (CVM을 이용한 해상교통안전시설 투자 편익 분석)

  • Kim, Sooyeob;Lee, Gunwoo
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2014.06a
    • /
    • pp.73-75
    • /
    • 2014
  • Marine transportation facility is public goods for the general public and their safety. The study used the Contingent Valuation Method (CVM), a method to estimate economic value of non-market goods, such as environmental goods. In order to analyze economic effects of marine accidents preventable by the VTS, the study estimated costs caused by marine accident cases. It conducted surveys with people and shipping companies in local areas where VTS is to be established in the future. According to a survey with people in areas where marine transportation control center is to be built (Tongyoung), the yearly benefit from building new VTS is estimated at KRW 11billion. If fees are paid in the form of income tax for five years from 2014, corresponding benefits during the same period will reach KRW 47.3 billion in current value. An analysis on economic validity of VTS establishment in Tongyong showed the B/C ration stood at 3.193, far higher than 1. The Net Present Value (NPV) was KRW 32.5 billion and the Internal Rate of Return (IRR) turned out to be 37.4% which was higher than social discount rates of 53.5%. On balance, the establishment has reasonable economic validity.

  • PDF

Tracheal gas insufflation (TGI) in patients with increased deadspace fraction: the effect and its determining factors (사강호흡율이 증가된 환자에서 기관내 가스주입법(Tracheal Gas Imsufflation)이 가스교환에 미치는 효과와 그 결정인자)

  • Lim, Chae Man;Jung, Bok Hyun;Koh, Youn Suck;Lee, Sang Do;Kim, Woo Sung;Park, Pyung Hwan;Kim, Dong Soon;Kim, Won Dong
    • Tuberculosis and Respiratory Diseases
    • /
    • v.44 no.1
    • /
    • pp.136-145
    • /
    • 1997
  • Background : Tracheal Gas Insufflation (TGI) is one of the newer ancillary measures in mechanical ventilation employed to enhance carbon dioxide elimination. TGI exerts its effect through reduction of deadspace ventilation, but the factors determining its effect are not well studied yet. Method : The subjects were seven mechanically-ventilated patients ($58.8{\pm}10.6$ yrs) who showed increased physiologic deadspace greater than 60%. After 30 nun of stabilization with 100% oxygen on pressure control ventilation, continuous flow TGI was administered via the insufflation lumen of Hi-Lo Jet Tracheal Tube (Mallincrodt, USA) for 15 min at 3 L/min and 5 L/min each. Results : $PaCO_2$ was decreased ($51.4{\pm}17.6$ at baseline, $49.1{\pm}18.9$ at TGJ 3 L/min $45.0{\pm}14.9$ mm Hg at TGI 5 L/min, p=0.050), and pH was increased ($7.37{\pm}0.12$, $7.38{\pm}0.13$, $7.39{\pm}0.12$, respectively, p=0.037) while mixed expired $CO_2$ ($P_ECO_2$) was not changed significantly from baseline (p=0.336) by TGI. Physiologic deadspace(Vdphy) was decreased ($73.0{\pm}7.9$% at baseline, $69.8{\pm}10.0$% at TGI 3 L/min, and $67.1{\pm}10.1$% at TGI 5 L/min, p=0.015). $AaDO_2$(p=0.147), Vt(p=0.2140), Pmean(p=0.7788) and mean arterial pressure(p=0.4169) were not changed. The correlation between % maximal decrease of Vdphy were r=0.790 with the ratio of baseline Vdana/Vdphy(p=0.035) and r=-0.754 with baseline Vdalv(p=0.050). Conclusion: TGI was effective in reducing $PaCO_2$ and deadspace, and the deadspace-reducing effect was best correlated with baseline anatomic/physiologic deadspace ratio.

  • PDF

Improvement of Rotary Tine for Barley Seeder Attached to Rotary Tiller (로우터리 맥류파종기 경운날의 개량시험)

  • 김성래;김문규;김기대;허윤근
    • Journal of Biosystems Engineering
    • /
    • v.4 no.1
    • /
    • pp.1-23
    • /
    • 1979
  • The use of barley seeder attached to rotary tiller in the rural area has a significant meaning not only for the solution of labor peak season, but also for the increase of land utilization efficiency. The facts that presently being used barley seeders are all based on the mechanical principles of the reverse rotation, center drive and are all using forward rotating tine, which is used to be easily and heavily worn out when it rotates reversely, raise problem of recommending them to rural area in Korea. Therefore, the main objective of the study was to develop new type of rotary tine attachable to barley seeders. To attain the objective the following approaches were applied. (1) The kinematic analysis of reverse rotating barley seeders. (2) The studies on the soil bin and artificial soil. (3) The comparative experiment on the power requirement of prototype tine. The results obtained from the studies are summarized as follow: 1. The kinematic analysis of barley seeder attached to rotary tiller: The following results were obtained from the kinematic analysis for deriving general formulae of the motion and velocity characterizing the rotary tine of barley seeders presently being used by farmers. a) The position vector (P) of edge point (P) in the rotary tine of reverse rotating, center drive was obtained by the following formula. $$P=(vt+Rcos wt)i+Rsin wt j+ \{ Rcos \theta r sin \alpha cos (wt- \beta +\theta r) +Rsin \theta r sin \alpha sin (wt-\beta + \theta r) \} lk $$ b) The velocity of edge point $(P^')$ of reverse rotating, center drive rotary tine was obtained by the following formula. $$(P^')=(V-wR sin wt)i+(w\cdot Rcoswt)j + \{ -w\cdot Rcos \theta r\cdot sin \alpha \cdot sin (wt-\beta +\theta r) + w\cdot Rsin \theta r\cdot sin \alpha \cdot cos (wt- \beta + \theta r \} k $$ c) In order to reduce the power requirement of rotary tine, the angle between holder and edge point was desired to be reduced. d) In order to reduce the power requirement, the edge point of rotary tine should be moved from the angle at the begining of cutting to center line of machine, and the additional cutting width should be also reduced. 2. The studies on the soil bin and artificial soil: In order to measure the power requirement of various cutting tines under the same physical condition of soil, the indoor experiments Viere conducted by filling soil bin with artificially made soil similar to the common paddy soil and the results were as follows: a) When the rolling frequencies$(x)$ of the artificial soil were increased, the densIty$(Y)$ was also increased as follows: $$y=1.073200 +0.070780x - 0.002263x^2 (g/cm^3)$$ b) The absolute hardness $(Y)$ of soil had following relationship with the rolling frequencies$(x)$ and were increased as the rolling frequencies were increased. $$Y=37.74 - \frac {0.64 + 0.17x-0. 0054x^2} {(3.36-0.17x + 0.0054x^2)^3} (kg/cm^3)$$ c) The density of soil had significant effect on the cohesion and angle of internal friction of soil. For instance, the soil with density of 1.6 to 1.75 had equivalent density of sandy loam soil with 29.5% of natural soil moisture content. d) The coefficient of kinetiic friction of iron plate on artificial soil was 0.31 to 0.41 and was comparable with that of the natural soil. e) When the pulling speed of soil bin was the 2nd forward speed of power tiller, the rpm of driving shaft of rotary was similar to that of power tiller, soil bin apparatus is indicating the good indoor tester. 3. The comparative experiment on the power requirement of prototype tine of reverse rotating rotary: According to the preliminary test of rotary tine developed with various degrees of angle between holder and edge pcint due to the kinematic analysis, comparative test between prototype rotary tine with $30 ^\circ $ and $10 ^\circ$ of it and presently being used rotary tine was carried out 2nd the results were as follows: a) The total cutting torque was low when the angle between holder and edge point was reduced. b) $\theta r$ (angle between holder and edge point) of rotary tine seemed to be one: of the factors maximizing the increase of torque. c) As the angle between holder and edge point ($\theta r$) of rotary tine was $30 ^\circ $ rather than $45 ^\circ $, the angle of rotation during cutting soil was reduced and the total cutting torque was accordingly reduced about 10%, and the reduction efficiency of total cutting torque was low when the angle between holder and edge point ($\theta r$) of rotary tine was $10 ^\circ $, which indicates that the proper angle between holder and edge point of rotary tine should be larger than $10 ^\circ $ and smaller than $30 ^\circ $ . From above results, it could be concluded that the use of the prototype rotary tine which reduced the angle between holder and edge point to $30 ^\circ $, insted of $45 ^\circ $, is disirable not only decreasing the power requirements, but also increasing the durabie hour of it. Also forward researches are needed, WIlich determine the optimum tilted angle of rotary brocket, and rearrangement of the rotary tine on the rotary boss.

  • PDF

Effects of Selenium and Vitamin E Administration on the Semen Characteristics, Blood Chemical Values and Hormone in Hanwoo Sires II. Changes of Selenium and Vitamin E Concentrations of Blood in Hanwoo Sires after Selenium, Vitamin E and rBST Administration (Selenium 과 Vitamin E 투여가 한우 종모우의 정액성상, 혈액성분 및 호르몬 변화에 미치는 효과 II. Selenium, Vitamin E 및 rBST 투여가 한우 종모우의 혈중내 Selenium 과 Vitamin E 의 농도 변화에 미치는 효과)

  • 박동헌;양부근;김종복;전기준;정희태;박춘근;이성수;박노형;원유석
    • Korean Journal of Animal Reproduction
    • /
    • v.23 no.3
    • /
    • pp.205-212
    • /
    • 1999
  • The present study was designed to examine the effects of selenium(Se), vitamin E(Vit. E) and recombinant Bovine Somatotropin(rBST) administration on the selenium and vitamin E concentrations of blood in Hanwoo sires Hanwoo sires were randomly assigned to five groups; 1. control, 2. rBST, 0.09mg/kg body weight (BW) 3. Vit E, 1,500IU/kg BW, 4. Se 0.lmg/kg BW, 5. Vit E, 1.500IU plus Se 0.1mg/kg BW. rBST, Vit. E and Se for each experimental group were given 6 times at 15 days interval by intramuscular injection. Blood samples were collected 10 times for experimental periods, separated the serum by centrifugation, and stored at -7$0^{\circ}C$. Se and Vito E concentrations in blood were measured by fluorophotometer and HPLC. Se concentrations of blood in control, rBST, Vito E, Se and Se plus Vito E groups were 64.55, 65.50, 68.15, 73.11 and 74.09 ppb/$m\ell$, respectively. Se concentration in Vit. E plus Se group was significantly higher than in control and rBST groups (P<0.05), but Vito E group was not significantly different in control and rBST groups(P>0.05). The Vit. E concentrations of blood in control, rBST, Vit. E, Se and Se plus Vit. E groups were 2.27, 2.32, 2.80, 2.58 and 2.75 ppm/$m\ell$, respectively. Vit. E and Vit. E plus Se groups were slightly higher than those of any other groups, but not significantly difference in 외 I experimental groups(P<0.05). These results indicate that Se and Vit. E concentrations of blood were slightly increased with the injection of Se and Vit. E in Hanwoo sires.

  • PDF