• Title/Summary/Keyword: Voxel Finite Element

Search Result 11, Processing Time 0.027 seconds

Finite element modeling of the mandible using voxel mesh method (Voxel mesh 기법을 이용한 하악골의 유한요소모델링)

  • 이은택;오택열;변창환;이병권;유용석
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1997.10a
    • /
    • pp.600-604
    • /
    • 1997
  • Knowledge of the complex biomechanical behavior of the human mandible is of great importance in various clinical situations. Various approaches can be used to evaluate the physical behavior of bone. In this study, we developed the voxel mesh program(Bionix) and generated FE models of mandible using Bionix and using handmade work and compared them with free vibration results derived from finite element analysis(FEA). The data of FE models based on DICOM File exported from Computed tomography(CT). Comparing the two models, we found a good correlation about mode type and natural frequency. The voxel based finite element mesh is a valid and accurate method to predict parameters of the complex biomechanical behavior of human mandibles.

  • PDF

A Study on the Voxel Mesh Technique for Finite Element Modeling of Human Bone (인체 골(bone)의 유한요소 모델링을 위한 VOXEL MESH 기법에 관한 연구)

  • 변창환;오택열;백승민;채경덕
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2002.10a
    • /
    • pp.1081-1084
    • /
    • 2002
  • In this study, we perform 3-D reconstruction of human proximal femur from DICOM files by using voxel mesh algorithm. After 3-D reconstruction, the model converted to Finite Element model which developed for automatically making not only 3-D geometrical model but also FE model from medical image dataset. During this job, trabecular pattern, one of characteristic of human bone can be added to the model by means of giving it's own elastic property calculated from intensity in CT scanned image to the each voxel. And then another model is made from same image dataset which have two material properties - one corresponds to cortical bone, another to trabecular bone. Finally, validity of voxel mesh technique is verified through comparing results of FE analysis, free vibration and stress analysis.

  • PDF

Estimation of Natural frequencies in Osteoporotic Mouse Femur: A finite Element Analysis and a Vibration Test (골다공증에 걸린 쥐 대퇴골의 고유진동수 예측: 유한 요소 해석 및 진동 실험)

  • Kim, Yoon-Hyuk;Byun, Chang-Hwan;Oh, Taek-Yul
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.25 no.4
    • /
    • pp.239-246
    • /
    • 2005
  • In this study, a finite element analysis and a vibration test were performed to estimate the natural frequencies of mouse femurs with osteoporosis. Three groups of the femurs include the osteoporotic group, the treated group and the normal group. For the finite element analysis, the micro finite element model of the femur was reconstructed using the Micro-CT images and the Voxel mesh generation algorithm. In the vibration test, the natural frequencies were measured by the mobility test. from the results, the averaged natural frequencies in the osteoporotic group were the highest, followed by those in the treated group. The finite element models were validated within 15% errors by comparing the natural frequencies in the finite element analysis with those in the vibration test. The developed Micro-CT system, the Yokel mesh generation algorithm, the presented finite element analysis, and vibration test could be useful for the investigation of the structural change of the bone tissue, and the diagnosis and the treatment in the osteoporosis.

Normal and Reconstructed Mandibular Condyle Mechanics

  • Hollister, S.J.;Feinberg, S.E.
    • Journal of Mechanical Science and Technology
    • /
    • v.15 no.7
    • /
    • pp.974-981
    • /
    • 2001
  • One approach to reconstructing a damaged mandibular condyle is to replace it with a rib graft. This procedure requires removal of the lateral pterygoid muscle. The rib graft has significantly different shape and mechanical properties than the original condyle. These three factors can be expected to alter mandible (jaw) mechanics. We used voxel-based finite element methods to analysis both normal and a simulated reconstructed mandible using data from the US NIH Visible Human Female. Results demonstrated significant differences between normal and reconstructed mandible mechanics. The reconstructed mandible displaced more than the normal mandible. Stresses in the rib graft were 3 to 4 times higher than in a normal mandibular condyle. Stresses in the rest of the mandible were also higher in the reconstructed case. Further analyses are required to determine how each of the alterations in the reconstructed mandible contributes to the difference in reconstructed mandible mechanics.

  • PDF

Topology Optimization Using Digital Images (디지털 이미지를 이용한 위상최적설계)

  • Shin, Woon-Joo;Min, Seung-Jae
    • Korean Journal of Computational Design and Engineering
    • /
    • v.11 no.4
    • /
    • pp.265-272
    • /
    • 2006
  • For the design and analysis of 3D object featuring complexity and irregularity in shape, sectional digital images measured by an industrial CT scanner are employed to generate a finite element model with uniform voxels. The voxel model plays a key role in developing an integrated reverse engineering system including geometric modeling, simulation and optimization. Design examples applied to topology optimization show that the proposed approach can provide a remarkable reduction in time cost at the conceptual and detail design stages.

A study on the finite element modeling of femur based marching cube algorithm (Marching cube 알고리즘을 이용한 대퇴골의 유한요소 모델링에 관한 연구)

  • 곽명근;오택열;변창환;이은택;유용석
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2002.10a
    • /
    • pp.1074-1077
    • /
    • 2002
  • Biomechanical behavior of the human femur is very important in various clinical situations. In this study, the data of FE models based on DICOM file exported from Computed tomography(CT). We generated FE models(voxel model, tetra model) of human femur using CT slide image. We compared them with Yon Mises stress results derived from finite element analysis(FEA). Comparing the two models, we found a correlation of them. As a result, the tetra model based proposed marching cube algorithm is a valid and accurate method to predict parameters of the complex biomechanical behavior of human femur.

  • PDF

MICRO-CT를 이용한 쥐 대퇴골의 유한요소 해석

  • 변창환;오택열
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2004.05a
    • /
    • pp.296-296
    • /
    • 2004
  • 실험상의 어려움으로 인하여 생체역학 분야에서 유한요소법은 최선의 대안으로 여겨지고 있다. 또한, CT를 비롯한 여러 디지털 장비로부터 얻은 영상데이터를 이용하여 유한요소모델을 생성하는 방법으로 모델 생성 속도의 향상을 가져와 더욱 효율을 높이고 있다. 그러나, 일반 CT의 해상도를 가지고는 골(bone) 변화의 주를 이루고 있는 해면골(trabecular bone)의 변화를 파악하기에는 큰 어려움이 따른다. 이에 본 논문에서는 10~20$\mu\textrm{m}$ 정도까지의 해상도를 가지는 Micro-CT의 영상데이터를 이용하여 유한요소 모델을 생성하고 해석하여 보았다.(중략)

  • PDF

Regional Morphological and Mechanical Characteristics in the Human Thoracic Vertebral Trabecular Bones (인체 흉추 해면골의 영역별 형태학적 및 기계적 특성 연구)

  • Lee, Tae-Woo;Woo, Dae-Gon;Ko, Chang-Young;Kim, Han-Sung
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.27 no.1
    • /
    • pp.134-141
    • /
    • 2010
  • This study analyzed the regional morphological and mechanical characteristics of vertebrae by using micro-computed tomography (micro-CT) and micro finite element analysis (FEA). For the present study, the $12^{th}$ human thoracic vertebral bones (an 85-years female and a 48-years male) were used. These were scanned by using micro-CT. Structural parameters were evaluated from the acquired 20 image data for fifteen $4{\times}4mm^2$ regions (five regions in respective layers of superior, middle and inferior part) in the thoracic vertebral trabecular bones. $4{\times}4{\times}4mm^3$ cubic finite element models of each regions were created at $70{\mu}m$ voxel resolution to investigate effective modulus ($E^+$). The present study indicated that there were significant differences in morphological and elastic mechanical characteristics of each region. There are close relationship between effective modulus and structural model index (SMI) in the bone of the 48-years male and between effective modulus and bone volume fraction (BV/TV) in the bone of the 85-years female. In addition, the effective modulus of central regions is about 80% stiffer than that of lateral regions at transverse plane. These findings may be likely to explain the previous result that a change of loading distribution of the vertebral trabecular bones is caused by spinal curvature and nucleus pulpous degeneration of the intervertebral disc.

Quadrilateral mesh fitting that preserves sharp features based on multi-normals for Laplacian energy

  • Imai, Yusuke;Hiraoka, Hiroyuki;Kawaharada, Hiroshi
    • Journal of Computational Design and Engineering
    • /
    • v.1 no.2
    • /
    • pp.88-95
    • /
    • 2014
  • Because the cost of performance testing using actual products is expensive, manufacturers use lower-cost computer-aided design simulations for this function. In this paper, we propose using hexahedral meshes, which are more accurate than tetrahedral meshes, for finite element analysis. We propose automatic hexahedral mesh generation with sharp features to precisely represent the corresponding features of a target shape. Our hexahedral mesh is generated using a voxel-based algorithm. In our previous works, we fit the surface of the voxels to the target surface using Laplacian energy minimization. We used normal vectors in the fitting to preserve sharp features. However, this method could not represent concave sharp features precisely. In this proposal, we improve our previous Laplacian energy minimization by adding a term that depends on multi-normal vectors instead of using normal vectors. Furthermore, we accentuate a convex/concave surface subset to represent concave sharp features.

The elastic and plastic behaviour of the micro-FE models for vertebral trabecular bones (척추 해면골에 대한 미세 유한요소모델의 탄성 및 소성특성에 관한 연구)

  • 우대곤;김한성;원예연;백명현;탁계래
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2003.06a
    • /
    • pp.1320-1323
    • /
    • 2003
  • In this study, the micro-FE analyses were carried out for the plastic behaviour of vertebral trabecular bones. Many researchers have investigated the elastic behaviour of trabecular bones by using the micro-finite element models based on the micro-CT images. However, there was no micro-FE model to account for the plastic behaviour of trabecular bones. Ulrich et at. reported that best results at coarser model were obtained when using 'compensated hexahedron models' with the same relative density. This study indicates that, for the elastic and plastic analysis, 'the compensated hexahedron FE model' is likely to be limited to about 63$\mu\textrm{m}$ image resolution in the vertebra trabecular bones.

  • PDF