• Title/Summary/Keyword: Von Graefe test

Search Result 15, Processing Time 0.023 seconds

Comparisons of Phoria Test Among Prism Settings of Von Graefe Technique (Von Graefe법의 프리즘 세팅에 따른 사위검사의 비교)

  • Yu, Dong-Sik;Ha, Eun-Mi
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.20 no.2
    • /
    • pp.211-218
    • /
    • 2015
  • Purpose: The aim of this study was to compare the differences among prism settings of the von Graefe technique for phoria measurement. Methods: Thirty eight healthy subjects (mean age $22.35{\pm}2.72years$) were tested with eye examination by interview, cover test, and refraction. Phorias were measured in a random order using four prism settings for the von Graefe method: base-in (BI) and base-up (BU), BI and base-down (BD), BU and BI, and BD and BI over the right and left eye, respectively. Results: Among the four prism settings in measurements of lateral and vertical phoria, there were not significant differences at distance, whereas there were significant at near. The reliability of near lateral phoria (ICC: 0.95) was good, but that of near vertical phoria was less reliable (ICC: 0.83). In comparisons of the paired t-test, the 95% limits of agreement, and mean difference between prism settings, BU had more useful than other prism settings at near phoria. Conclusions: Results from this study suggest that the von Graefe test with BU or BU including other setting prisms have useful methods, especially for near phoria measurements.

A study on the measurement and tendency of heterophoria using Von Graefe test and Maddox rod test (프리즘 분리법과 마독스 로드 검사법을 이용한 사위측정과 경향 연구)

  • Oh, Hyun-Jin;Doo, Ha-Young;Oh, Seung-Jin
    • Journal of Digital Convergence
    • /
    • v.10 no.11
    • /
    • pp.485-491
    • /
    • 2012
  • To investigate the difference in the value of horizontal heterophoria measured in phoria test of about normal 72 college students, using both Von Graefe test and Maddox rod test. We used two different methods which are Von Graefe test and Maddox rod test on full correction condition at the long distance. Using Von Graefe test of horizontal heterophoria Measurement, We measured 21 patients(29%) for orthophoria, 36 patients(50%) for exophoria and 15 patients(21%) for esophoria at distance. Using Maddox rod test of horizontal heterophoria Measurement, We measured 36 patients(50%) for orthophoria, 26 patients(36%) for exophoria and 10 patients(14%) for esophoria at distance. Each test average were $0.93{\Delta}$ BI for Von Graefe test, $0.96{\Delta}$ BI for Maddox rod test. We could not find the definite difference about the value of horizontal heterophoria aby testing method. Furthermore, heterphoria AC/A ratio was found to vary from 1.0 to 8.8 and its relationship to refractive error could not be determined.

Repeatability and Reliability of a New Phoria Test Using Flashed and Auto-flashed Presentation

  • Moon, Byeong-Yeon;Park, Sun-Young;Cho, Hyun Gug
    • Journal of the Optical Society of Korea
    • /
    • v.16 no.4
    • /
    • pp.418-424
    • /
    • 2012
  • The purpose of this study was to assess repeatability and reliability of a new phoria test as compared to established phoria tests and to assess the possibility of mobile or online testing using the auto-flashed presentation. Near dissociated phoria was measured using the von Graefe method, the Howell card test, the modified Thorington test, and a new dichromatic card test (Red-Blue Phoria card test; RBP card test) on 109 subjects. The inter-examiner difference and test-retest difference were calculated. With the auto-flashed presentation of the RBP card test, near dissociated phoria was measured and the intraclass correlation coefficient and test-retest repeatability was assessed on 26 subjects. The variation in inter-examiner repeatability was the smallest for the modified Thorington test (+3.1/-2.6). The RBP card test was +3.0/-3.1, the Howell card test was +3.5/-2.7, and the von Graefe test was +6.2/-6.0. The variation in test-retest repeatability was the smallest for the RBP card test (+0.4/-1.4). The modified Thorington test was +1.3/-1.3, the Howell card test was +1.27/-1.45, and the von Graefe test was +1.59/-2.20. The ICC was 0.919 for the auto-flashed presentation of the RBP card test. The RBP card test is considered a highly repeatable method clinically and can be made a useful application for testing in mobile or online.

Investigation of the horizontal heterophoria measurement at distance by various testing method (사위검사 방법의 차이에 따른 원거리 수평사위 검사값 비교)

  • Sim, Hyun-Seog;Lee, Seang-Wook;Jang, Seong-Joo
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.6 no.2
    • /
    • pp.155-160
    • /
    • 2001
  • To investigate the subjective refractive error with Von Graefe test. Maddox Rod test and polarizing lens test of Horizontal Heterophoria Measurement at distance on normal 109 subjects aged from 18 to 30 years old. The results were as follows: 1. Using Von Graefe Horizontal Heterophoria Measurement, they were measured 15% for orthophoria, 65% for exophoria and 20% for esophoria at distance. 2. Using Maddox Rod Horizontal Heterophoria Measurement, they were measured 14% for orthophoria, 57% for exophoria and 29% for esophoria at distance. 3. Using polarizing lens test of Horizontal Heterophoria Measurement, they were measured 15% for orthophoria, 72% for exophoria and 13% for esophoria at distance. 4. Each test average were $1.32{\Delta}BI$ for Von Graefe test, $0.88{\Delta}BI$ for Maddox Rod test and $1.76{\Delta}BI$ for polarizing lens test. 5. Patient's preference distribution were 44% for Von Graefe test, 28% for Maddox Rod test and 28% for polarizing lens test.

  • PDF

Analysis of far & near distance of lateral phoria by various testing methods (검사 방법에 따른 원·근거리 수평사위의 분석)

  • Hong, Dong-Gyun;Jung, Han-Sub;Park, Sang-An
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.9 no.2
    • /
    • pp.423-430
    • /
    • 2004
  • This Study on three different methods which are Von Graefe test, Maddox Rod test and Howell card test of measuring far and near lateral phoria investigated. It reviewed that 420 subjects aged from 15 to 35 years old. The result were as follows; 1. Using Von Graefe lateral phoria measurement, they were measured 6% for orthophoria, 62% for exophoria, 32% for esophoria at far distance. 2. Using Von Graefe lateral phoria measurement, they were measured 2% for orthophoria, 74% for exophoria, 24% for esophoria at near distance. 3. Using Maddox Rod lateral phoria measurement, they 59% for exophoria, 37% for esophoria at far distance. 4. Using Maddox Rod lateral phoria measurement, they 67% for exophoria, 30% for esophoria at near distance. 5. Using Howell card lateral phoria measurement, they 60% for exophoria, 32% for esophoria at far distance. 6. Using Howell card lateral phoria measurement, they 69% for exophoria, 27% for esophoria at near distance.

  • PDF

The Effects of Visual Training on Binocular Anomalies (양안시 기능 이상의 시훈련(Visual Training)의 효과)

  • Kim, In-Suk;Hong, Dong-Gyun;Kim, Jung-Hee
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.10 no.1
    • /
    • pp.53-61
    • /
    • 2005
  • In this study, we measured Near Point of Convergence(N.P.C) tests, Phoria tests using Von Grafe method and relative convergence tests on 138 men and 162 women, so a total of 300 subjects aged between 8~45 to examine the improvement of the fusion vergence through visual training and obtained as follows. 1. According to the results, the near point of convergence of 57 (19%) subjects were shorter than 7cm, and 243 (81%) were 7cm or longer, having a problem in convergence. After visual training, the number of subjects have the value shorter than 7 cm increased from 57 to 111 (37%), and the number of those have the value 7cm or longer decreased significantly form 243 to 189 (63%). 2. The results of the measure of lateral Phoria at far distance by Von Grafe method showed orthophoria 18 (6%), exophoria 198 (66%), esophoria 84 (28%). After phoria test, we examined the N.R.C and P.R.C test. The results showed that the hope finger was improved after V.T using B.l, B.O card. 3. The results of the measure of lateral Phoria at near distance by Von Grafe method showed orthophoria 6 (2%), exophoria 222 (74%), esophoria 72 (24%). After phoria test, we examine the N.R.C and P.R.C test. The results showed that the hope finger was improved after V.T using B.I, B.O card.

  • PDF

A study on the distance and near horizontal phoria of the young people in Korea (한국 청년의 원거리와 근거리 수평사위에 관한 연구)

  • Kim, Hye-Dong;Lee, Dong-Hee
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.9 no.2
    • /
    • pp.251-255
    • /
    • 2004
  • Our research is about the measurement of the distance & near horizontal phoria by the Von Graefe test. The inspection was processed about normal 60 subjects(120eyes) aged from 20 to 30) years old by the subjective method of refraction. Among 120 eyes, the myopia is 64eyes(53%) and the emmetropia is 56eyes(47%). In the measurement of the distance horizontal phoria, we could know that the exophoria is 40%(24 subjects), the esophoria is 40%(24 subjects), and the orthophoria is 20%(12 subjects). In case of the near horizontal phoria, we could know that the exophoria is 65%(39 subjects), the esophoria is 23.3%(14 subjects), and the orthophoria is 11.7%(7 subjects).

  • PDF

Comparison of three different methods of measuring horizontal phoria and vertical phoria (검사방법에 따른 수평·수직사위량의 비교)

  • Kim, Hye-Dong;Kim, Dae-Nyoun;Park, Eun-Kyeu
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.8 no.2
    • /
    • pp.13-18
    • /
    • 2003
  • We did the comparison research about three different methods of measuring horizontal phoria and vertical phoria which are Von Graefe test, Maddox Rod test and polarizing lens test. The inspection was don with the subjective method of refraction about normal 63 subjects aged from 20 to 28 years old. The analysis of date resulted in as follows : 1. Using Von Graefe Horizontal phoria Measurement, they were measured 5% for orthpharia, 51% for exophoria and 44% for esophoria. 2. Using Von Graefe vertical phoria Measurement, they were measured 68% for orthphoria, 20% for left hypophoria against the right and 12% for left hyperphoria against the right. 3. Using Maddox Rod Horizontal phoria Measurement, they were measured 7% for orthphoria, 49% for exophoria and 44% for esophoria. 4. Using Maddox Rod vertical phoria Measurement, they were measured 70% for orthphoria, 19% for left hypophoria against the right and 11% for left hyperphoria against the right. 5. Using Polarizing Horizontal phoria Measurement, they were measured 10% for orthphoria, 49% for exophoria and 41% for esophoria. 6. Using Polarizing vertical phoria Measurement, they were measured 92% for orthpharia, 5% for left hypophoria against the right and 3% for left hyperphoria against the right.

  • PDF

A Comparative Study on Quantity of Phoria between New Phoria Measurement with 3D Display and Existing Methods (개발된 3D Display 장치를 이용한 사위검사법과 기존 사위검사법으로 측정한 사위량 비교에 관한 연구)

  • Kang, Seok Hyon;Hong, Hyungki
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.18 no.3
    • /
    • pp.313-320
    • /
    • 2013
  • Purpose: This study compared the quantity of phoria for distance by new method with that by existing methods. Methods: For this study, it was selected to two existing phoria measurements, von Graefe and Maddox rod. And new method named "3D polarizing phoria measurement" was designed to measure the quantity of phoria using polarizing glasses and 3D display. Unlike existing measurement using polarized lens, newly considered method measured the quantity of phoria in condition removed perfect binocular fusion using field stop on apparatus and polarized lens. For using new method for distance, it was developed a phoria test chart. It supports three kinds of phoria measurements. Subjects were 12 (male 6, female 6). They had three phoria tests (1 sets) including new method. It was considered the effect of experimental order, so we tested all cases about experimental order. The number of cases was 6 sets, and the sample size in this experiment was 72 sets. For removing binocular fusion, lighting of the laboratory that was below 10 lx and the background color of phoria test chart was dark, RGB=(20, 20, 20). Results: Subjects were sorted into three groups. Samples with exophoria and orthophoria were 30 sets each, and those with esophoria were 12 sets. The quantity of phoria measured three tests differ from each other like "newmethod < von Graefe < Maddox rod", and there were statistically significant difference each other. Conclusions: This study has great significance in the sense that new method was the measurement with naturally removing binocular fusion without dizziness during the tests.

Changes in Visual Function After Viewing an Anaglyph 3D Image (Anaglyph 3D입체 영상 시청 후의 시기능 변화)

  • Lee, Wook-Jin;Kwak, Ho-Won;Son, Jeong-Sik;Kim, In-Su;Yu, Dong-Sik
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.16 no.2
    • /
    • pp.179-186
    • /
    • 2011
  • Purpose: This study aimed to compare and assess changes of visual functions in viewing an anaglyph 3D image. Methods: Visual functions were examined before and after viewing a 2D image and an anaglyph 3D image with red-green glasses on seventy college students (mean age = 22.29${\pm}$2.19 years). Visual function tests were carried out for von Graefe phoria test, accommodative amplitude test by (-) lens addition, negative relative accommodation (NRA) and positive relative accommodation (PRA) test, negative relative convergence (NRC) and positive relative convergence (PRC) test, accommodative facility, and vergence facility test. Results: Assessment of the visual functions indicated that near exophoria and accommodative amplitude were reduced after viewing a 3D image, and although there were small changes in relation to these findings, NRC and PRC showed tendencies to increase and decrease at near, respectively. There were no significant changes with NRA and PRA, and accommodative and vergence facility were shown to have improved. Conclusions: Changes of visual functions were more in the 3D image than the 2D image, especially at near than distance. Particularly, the improvement of accommodative and vergence facility could be related to an effect of subsequent accommodation and vergence shift to have stereopsis in the 3D image. These results indicate that an anaglyph 3D image may, to some extent, be the effect of vision training such as anaglyphs.