• Title/Summary/Keyword: Volunteers

Search Result 1,993, Processing Time 0.034 seconds

Understanding Voluntary Disaster Workers with Their Burnout Pattern and the Group Differences in Secondary Traumatic Stress and World Assumptions (재난 자원봉사인력의 소진 양상에 따른 이차외상스트레스와 세상에 대한 신념의 차이)

  • Jiwon Min;Hyesun Joo;Hyunnie Ahn
    • Korean Journal of Culture and Social Issue
    • /
    • v.22 no.3
    • /
    • pp.363-385
    • /
    • 2016
  • As the role of volunteers in disaster settings has been growing overtime, the present study was aimed to understand voluntary disaster workers with their burnout pattern and examine group differences in their secondary traumatic stress and world assumptions. Total of 70 voluntary workers who served for recovery from Sewol ferry disaster participated in this study. Using cluster analysis, we identified three distinct cluster groups on the basis of three burnout subscale scores(emotional exhaustion, personal accomplishment, depersonalization): Group 1 was characterized by the highest score on personal accomplishment and low levels of emotional exhaustion and depersonalization. Group 2 scored the highest on emotional exhaustion and depersonalization, and relatively high on personal accomplishment. Group 3 was characterized by the lowest scores on three subscales. Results from χ2 tests showed that groups differed significantly on types and the period of support activities. Analysis of variance was conducted to identify further group differences. The results indicated that Group 2 scored the highest on secondary traumatic stress, while Group 1 scored the highest on worthiness of the self. Finally, the clinical implications and limitations of these results as well as suggestions for further research were discussed.

  • PDF

Effect of forearm length applied on empirical models of maximum endurance time during isometric elbow flexion (등척성 팔굽 굽힘시 최대근지구력시간의 실증적 모델에 적용한 전완길이의 영향)

  • Sang-Sik Lee;Kiyoung Lee
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.16 no.5
    • /
    • pp.338-346
    • /
    • 2023
  • During isometric elbow flexion, forearm length should be an important factor to determine not only joint torque but also maximum endurance time (MET), when the forearm is perpendicular to the direction of the force. The purpose of this paper is to examine the effect of forearm length as an additional factor on empirical models of MET such as an exponential model and a power model during isometric elbow flexion. Thirty volunteers participated in our experiment to measure factor variables such as circumferences and lengths of their upper and lower arms. Their METs were measured according to the percent of maximum voluntary contraction intensity (%MVC). For the multiple linear regression model of ln(MET) using these measurements, significant variables could be observed in %MVC and forearm lengths (P<0.05). The empirical models were assessed by these models using forearm length as the additional factor. Mean absolute deviations (MAD) between the measured METs amd the two empirical models were about 19.4 [s], but MAD using models applied forearm lengths were reduced to about 16.2 [s]. The correlation coefficients and intraclass correlation coefficients were about 0.87, but those applied forearm lengths were increased to about 0.91. These results demonstrated that forearm length was a significant additional factor to the empirical model.

Automated Measurement of Native T1 and Extracellular Volume Fraction in Cardiac Magnetic Resonance Imaging Using a Commercially Available Deep Learning Algorithm

  • Suyon Chang;Kyunghwa Han;Suji Lee;Young Joong Yang;Pan Ki Kim;Byoung Wook Choi;Young Joo Suh
    • Korean Journal of Radiology
    • /
    • v.23 no.12
    • /
    • pp.1251-1259
    • /
    • 2022
  • Objective: T1 mapping provides valuable information regarding cardiomyopathies. Manual drawing is time consuming and prone to subjective errors. Therefore, this study aimed to test a DL algorithm for the automated measurement of native T1 and extracellular volume (ECV) fractions in cardiac magnetic resonance (CMR) imaging with a temporally separated dataset. Materials and Methods: CMR images obtained for 95 participants (mean age ± standard deviation, 54.5 ± 15.2 years), including 36 left ventricular hypertrophy (12 hypertrophic cardiomyopathy, 12 Fabry disease, and 12 amyloidosis), 32 dilated cardiomyopathy, and 27 healthy volunteers, were included. A commercial deep learning (DL) algorithm based on 2D U-net (Myomics-T1 software, version 1.0.0) was used for the automated analysis of T1 maps. Four radiologists, as study readers, performed manual analysis. The reference standard was the consensus result of the manual analysis by two additional expert readers. The segmentation performance of the DL algorithm and the correlation and agreement between the automated measurement and the reference standard were assessed. Interobserver agreement among the four radiologists was analyzed. Results: DL successfully segmented the myocardium in 99.3% of slices in the native T1 map and 89.8% of slices in the post-T1 map with Dice similarity coefficients of 0.86 ± 0.05 and 0.74 ± 0.17, respectively. Native T1 and ECV showed strong correlation and agreement between DL and the reference: for T1, r = 0.967 (95% confidence interval [CI], 0.951-0.978) and bias of 9.5 msec (95% limits of agreement [LOA], -23.6-42.6 msec); for ECV, r = 0.987 (95% CI, 0.980-0.991) and bias of 0.7% (95% LOA, -2.8%-4.2%) on per-subject basis. Agreements between DL and each of the four radiologists were excellent (intraclass correlation coefficient [ICC] of 0.98-0.99 for both native T1 and ECV), comparable to the pairwise agreement between the radiologists (ICC of 0.97-1.00 and 0.99-1.00 for native T1 and ECV, respectively). Conclusion: The DL algorithm allowed automated T1 and ECV measurements comparable to those of radiologists.

COVID-19 Vaccination Alters NK Cell Dynamics and Transiently Reduces HBsAg Titers Among Patients With Chronic Hepatitis B

  • Hyunjae Shin;Ha Seok Lee;Ji Yun Noh;June-Young Koh;So-Young Kim;Jeayeon Park;Sung Won Chung;Moon Haeng Hur;Min Kyung Park;Yun Bin Lee;Yoon Jun Kim;Jung-Hwan Yoon;Jae-Hoon Ko;Kyong Ran Peck;Joon Young Song;Eui-Cheol Shin;Jeong-Hoon Lee
    • IMMUNE NETWORK
    • /
    • v.23 no.5
    • /
    • pp.39.1-39.15
    • /
    • 2023
  • Coronavirus disease 2019 (COVID-19) vaccination may non-specifically alter the host immune system. This study aimed to evaluate the effect of COVID-19 vaccination on hepatitis B surface Ag (HBsAg) titer and host immunity in chronic hepatitis B (CHB) patients. Consecutive 2,797 CHB patients who had serial HBsAg measurements during antiviral treatment were included in this study. Changes in the HBsAg levels after COVID-19 vaccination were analyzed. The dynamics of NK cells following COVID-19 vaccination were also examined using serial blood samples collected prospectively from 25 healthy volunteers. Vaccinated CHB patients (n=2,329) had significantly lower HBsAg levels 1-30 days post-vaccination compared to baseline (median, -21.4 IU/ml from baseline), but the levels reverted to baseline by 91-180 days (median, -3.8 IU/ml). The velocity of the HBsAg decline was transiently accelerated within 30 days after vaccination (median velocity: -0.06, -0.39, and -0.04 log10 IU/ml/year in pre-vaccination period, days 1-30, and days 31-90, respectively). In contrast, unvaccinated patients (n=468) had no change in HBsAg levels. Flow cytometric analysis showed that the frequency of NK cells expressing NKG2A, an NK inhibitory receptor, significantly decreased within 7 days after the first dose of COVID-19 vaccine (median, -13.1% from baseline; p<0.001). The decrease in the frequency of NKG2A+ NK cells was observed in the CD56dimCD16+ NK cell population regardless of type of COVID-19 vaccine. COVID-19 vaccination leads to a rapid, transient decline in HBsAg titer and a decrease in the frequency of NKG2A+ NK cells.

Comparative Analysis of Two Pedobarography Systems (두 족저압 측정장비의 비교 분석)

  • Ho Won Kang;Soomin Pyeun;Dae-Yoo Kim;Yun Jae Cho;Min Gyu Kyung;Dong Yeon Lee
    • Journal of Korean Foot and Ankle Society
    • /
    • v.28 no.1
    • /
    • pp.21-26
    • /
    • 2024
  • Purpose: Foot pressure measurement devices are used widely in clinical settings for plantar pressure assessments. Despite the availability of various devices, studies evaluating the inter-device reliability are limited. This study compared plantar pressure measurements obtained from HR Mat (Tekscan Inc.) and EMED-n50 (Novel GmbH). Materials and Methods: The study involved 38 healthy male volunteers. The participants were categorized into two groups based on the Meary's angle in standing foot lateral radiographs: those with normal feet (angles ranging from -4° to 4°) and those with mild flatfeet (angles from -8° to -15°). The static and dynamic plantar pressures of the participants were measured using HR Mat and EMED-n50. The reliability of the contact area and mean force was assessed using the interclass correlation coefficient (ICC). Furthermore, the differences in measurements between the two devices were examined, considering the presence of mild flatfoot. Results: The ICC values for the contact area and mean force ranged from 0.703 to 0.947, indicating good-to-excellent reliability across all areas. EMED-n50 tended to record higher contact areas than HR Mat. The mean force was significantly higher in the forefoot region when measured with EMED-n50, whereas, in the hindfoot region, this difference was observed only during static measurements with HR Mat. Participants with mild flatfeet exhibited significantly higher contact areas in the midfoot region for both devices, with no consistent differences in the other parameters. Conclusion: The contact area and mean force measurements of the HR Mat and EMED-n50 showed high reliability. On the other hand, EMED-n50 tended to record higher contact areas than HR Mat. In cases of mild flatfoot, an increase in contact area within the midfoot region was observed, but no consistent impact on the differences between the two devices was evident.

A Study on the Financial Performance for Nonprofit Performing Arts Organizations: Focusing on American Symphony Orchestras (비영리 공연조직의 재정성과에 관한 연구 - 미국오케스트라를 중심으로 -)

  • Park, Sunmi;Choi, Young-Jun
    • Korean Association of Arts Management
    • /
    • no.50
    • /
    • pp.33-63
    • /
    • 2019
  • This study examines financial performance of nonprofit performing arts organizations to provide concrete suggestions and improve their financial performance so that they can build strategies to continue organizational activities. This study investigates empirical data of IRS 990 tax form of top 73 US orchestras and analyzed GLS pannel. Dependent variables are measured as contributions and ticket sales, and independent variables are measured as economic environment, cultural capital, orchestra characters, government grants, and social capital. Based on the finding from the research, determination of contribution outcomes is positively affected by state employment and orchestra's internal characteristics including age, size and conductor's US nationality, government grants, and volunteer. Ticket sales are affected by employment, education level, orchestra's resources, government grants, and volunteer. However, a size of cultural market negatively influences on financial outcomes and cultural capital doesn't influence on results. Interesting finding is a relationship between volunteers and organizations is vital of their fiscal achievement. This is significant in empirical analysis on nonprofit performing arts organizations from an economic view point, and will contribute on organizations to improve their strategic plan to sustain a business.

Quasi-breath-hold (QBH) Biofeedback in Gated 3D Thoracic MRI: Feasibility Study (게이트 흉부자기 공명 영상법과 함께 사용할 수 있는 의사호흡정지(QBH) 바이오 피드백)

  • Kim, Taeho;Pooley, Robert;Lee, Danny;Keall, Paul;Lee, Rena;Kim, Siyong
    • Progress in Medical Physics
    • /
    • v.25 no.2
    • /
    • pp.72-78
    • /
    • 2014
  • The aim of the study is to test a hypothesis that quasi-breath-hold (QBH) biofeedback improves the residual respiratory motion management in gated 3D thoracic MR imaging, reducing respiratory motion artifacts with insignificant acquisition time alteration. To test the hypothesis five healthy human subjects underwent two gated MR imaging studies based on a T2 weighted SPACE MR pulse sequence using a respiratory navigator of a 3T Siemens MRI: one under free breathing and the other under QBH biofeedback breathing. The QBH biofeedback system utilized the external marker position on the abdomen obtained with an RPM system (Real-time Position Management, Varian) to audio-visually guide a human subject for 2s breath-hold at 90% exhalation position in each respiratory cycle. The improvement in the upper liver breath-hold motion reproducibility within the gating window using the QBH biofeedback system has been assessed for a group of volunteers. We assessed the residual respiratory motion management within the gating window and respiratory motion artifacts in 3D thoracic MRI both with/without QBH biofeedback. In addition, the RMSE (root mean square error) of abdominal displacement has been investigated. The QBH biofeedback reduced the residual upper liver motion within the gating window during MR acquisitions (~6 minutes) compared to that for free breathing, resulting in the reduction of respiratory motion artifacts in lung and liver of gated 3D thoracic MR images. The abdominal motion reduction in the gated window was consistent with the residual motion reduction of the diaphragm with QBH biofeedback. Consequently, average RMSE (root mean square error) of abdominal displacement obtained from the RPM has been also reduced from 2.0 mm of free breathing to 0.7 mm of QBH biofeedback breathing over the entire cycle (67% reduction, p-value=0.02) and from 1.7 mm of free breathing to 0.7 mm of QBH biofeedback breathing in the gated window (58% reduction, p-value=0.14). The average baseline drift obtained using a linear fit was reduced from 5.5 mm/min with free breathing to 0.6 mm/min (89% reduction, p-value=0.017) with QBH biofeedback. The study demonstrated that the QBH biofeedback improved the upper liver breath-hold motion reproducibility during the gated 3D thoracic MR imaging. This system can provide clinically applicable motion management of the internal anatomy for gated medical imaging as well as gated radiotherapy.

A Study on Home Visiting Hospice Care of the Terminally Ill Patients (가정 호스피스케어환자 방문간호 조사분석)

  • Lee, So-Woo;Lee, Eun-Ok;Park, Hyun-Ae;Oh, Hyo-Sook;Ahn, Hyo-Seop;Huh, Dae-Suk;Yun, Young-Ho;Kim, Dal-Sook;Rho, Yoo-Ja
    • Journal of Hospice and Palliative Care
    • /
    • v.1 no.1
    • /
    • pp.39-46
    • /
    • 1998
  • Purpose : Hospice Care is considered as one of the most perfect solutions for the problems brought up as the number of chronically ill patients are increasing rapidly and most of social welfare oriented countries are seeking the quality of life. Our former studies(1996, 1997) were to find out the current status of the hospice care in Korea by surveying terminally ill patients and their family members as well as medical professionals. The former study was also to conduct the operation research by developing an information service system for training of hospice care teams and volunteers, and hospice patients management. The purpose of this study was that hospice information service system was tested by home visiting hospice care through visiting nurses. Methods : From October 1, 1997 to March 31, 1998, Twenty six terminal cancer patients were included in this study from Seoul National University Hospital and other hospital. Databases and homepage, hospice information service system were designed and developed for the information needed for the hospice care before this study by our research team and this services were available through the internet. Visiting nurses were trained about this system and they visited the patients with PC notebook and provided them hospice care with hospice information system. They collected physical, psychiatric, social data of the subjects at the first visit and during hospice care at home. Results : Sixteen subjects(61.5%) died during the study and the mean survival was 20.7 days. Anorexia(96.2%), immobility(88.5%) and pain(84.6%) were the major symptom in the 26 subjects, Altered nutrition(26.1%) and pain(12.4%) were the most frequent diagnoses in 226 nursing diagnoses of the subjects. Families understood and demanded the hospice care more than patients. And most patients and families didn't demand spiritual or social care. Conclusion : Through this demonstration study, it was found that we have to provide the information of pain management and nutritional support for patients by the nurses and visiting hospice nurse. The information service system needs to be upgraded with information and manpower of spiritual and social care according to the findings.

  • PDF

Effect of Trace Elements in Alcohol Beverages on the Type of Radiation-induced Cell Death (인체 임파구세포에서 X-선 조사에 의한 세포사의 형태에 주정성분이 미치는 영향)

  • Sohn, Jong-Gi
    • Journal of Radiation Protection and Research
    • /
    • v.35 no.2
    • /
    • pp.49-56
    • /
    • 2010
  • Developments of radioprotective agents are important issues for minimizing the troubles and the effective treatments in radiotherapy. But few agents are useful in clinical and practical fields. It was shown that trace elements in alcohol beverages might have radioprotective effect. In this study, the types of cell death of lymphocytes according to the commercial alcohol beverage was investigated. Normal healthy volunteers ingested distilled water, beer or soju containing $81.5mg{\cdot}dl^{-1}$ ethyl ahcohol, respectively. After 2 hours, their blood were sampled with their consents. Fraction of lymphocytes was isolated by density gradient method with Histopaque-1077 (Sigma) and irradiated with dose from 0.5 to 5 Gy. After 60 hour incubation, the cells were harvested and analysed by flow cytometry. Cell viability was decreased by dose dependent manner. Cell viability of beer group was reduced about 15% compared with control group. Apoptosis in soju group was reduced about 20% compared with control group. Apoptosis of beer and control groups are similar. Necrosis of soju group significantly increased about 35% compared with control group. Early apoptosis of beer group was increased compared with control group. Early apoptosis of soju group was decreased about 25% compared with control group. Late apoptosis of beer and control group was increased by dose dependent manner. Late apoptosis of soju group was increased about 20-30% compared with control group. Late apoptosis of soju was increased and the radioprotective effect of soju was minimal because late apoptosis induced the cell necrosis. In case of soju trace elements, total cell apoptosis was decreased about 20% and early cell apoptosis was remarkably low. In this case, mitotic cells death may be dominant mechanism. Therefore, trace elements in soju may not be effective radioprotective agents.

Reconstruction of Stereo MR Angiography Optimized to View Position and Distance using MIP (최대강도투사를 이용한 관찰 위치와 거리에 최적화 된 입체 자기공명 뇌 혈관영상 재구성)

  • Shin, Seok-Hyun;Hwang, Do-Sik
    • Investigative Magnetic Resonance Imaging
    • /
    • v.16 no.1
    • /
    • pp.67-75
    • /
    • 2012
  • Purpose : We studied enhanced method to view the vessels in the brain using Magnetic Resonance Angiography (MRA). Noticing that Maximum Intensity Projection (MIP) image is often used to evaluate the arteries of the neck and brain, we propose a new method for view brain vessels to stereo image in 3D space with more superior and more correct compared with conventional method. Materials and Methods: We use 3T Siemens Tim Trio MRI scanner with 4 channel head coil and get a 3D MRA brain data by fixing volunteers head and radiating Phase Contrast pulse sequence. MRA brain data is 3D rotated according to the view angle of each eyes. Optimal view angle (projection angle) is determined by the distance between eye and center of the data. Newly acquired MRA data are projected along with the projection line and display only the highest values. Each left and right view MIP image is integrated through anaglyph imaging method and optimal stereoscopic MIP image is acquired. Results: Result image shows that proposed method let enable to view MIP image at any direction of MRA data that is impossible to the conventional method. Moreover, considering disparity and distance from viewer to center of MRA data at spherical coordinates, we can get more realistic stereo image. In conclusion, we can get optimal stereoscopic images according to the position that viewers want to see and distance between viewer and MRA data. Conclusion: Proposed method overcome problems of conventional method that shows only specific projected image (z-axis projection) and give optimal depth information by converting mono MIP image to stereoscopic image considering viewers position. And can display any view of MRA data at spherical coordinates. If the optimization algorithm and parallel processing is applied, it may give useful medical information for diagnosis and treatment planning in real-time.