• Title/Summary/Keyword: Volumetric Method

Search Result 607, Processing Time 0.025 seconds

Evaluation of the Volume Changes of Grafted Bone Materials in Sinus Augmentation Procedure Using Dental Cone-beam CT (치과용 Cone-beam CT를 이용한 상악동 골 이식 후 나타난 골 이식재의 부피 변화평가)

  • Ohn, Byung-Hun;Seon, Hwa-Kyeong;Chee, Young-Deok
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.29 no.1
    • /
    • pp.23-36
    • /
    • 2013
  • To evaluate the 3-dimensional features of the grafted bone with maxillary sinus augmentation and to assess the relation between the degree of bone resorption and the type of bone grafting source and implant, and the operation method. A retrospective chart review of patients receiving sinus augmentation procedures for implant positioning was conducted: radiographic analysis of the volume and area of bone grafts was performed. The volumetric remodeling.measured at 6 months after implant positioning as the percentage of residual bone graft.was correlated to type of graft materials and operation methods. 53 dental implants positioned with sinus bone graft in 15 patients at Wonkwang University Sanbon Dental Hospital. Computed tomography scans,taken implant positioning after 6 months, showed greater resorption values for the group of $Puros^{(R)}$ graft alone from the group of mixed with $Puros^{(R)}$ and various bone graft (P<0.05, respectively). And resorption values according to operation methods have statistically significant difference(P<0.05). Volume change ratio of bone graft showed greater values for the group of delayed implant position from the group of simultaneously implant placement with bone graft. Retrospective data analysis shows that the method of graft with $Puros^{(R)}$ alone may occur greater resorption of graft materials than mixed graft material with $Puros^{(R)}$ and other graft materials. The group of simultaneously implant placement with bone graft also display smaller resorption ratio of bone graft than the group of delayed implant placement.

Improvement of Marshall Mix Design and Comparative Evaluation with Current Marshall Mix Design Method (마샬 배합설계 방법의 개선과 기존 방법과의 비교 평가)

  • Hwang, Sung-Do;Yoon, An-Sang;Kim, Boo-Il
    • International Journal of Highway Engineering
    • /
    • v.6 no.4 s.22
    • /
    • pp.13-24
    • /
    • 2004
  • The Marshall mix design method used in Korea, which was described in the design & construction regulation, had been introduced from Japan Highway Cooperation standard guide. Most engineers have thought that it is the major reason that causes pavement distresses. Therefore, there is a need to modify the current Marshall mix design through using the volumetric design concept, which is most widely used in asphalt mix design. The modified mix design determines the preliminary optimum asphalt content at 4% VTM (Voids in Total Mix). If the Marshall properties, which are VFA, VMA, stability, and flow, were satisfied with the requirements, the preliminary optimum asphalt content is determined as the final optimum asphalt content. The modified Marshall mix design considers VMA. while the current Marshall mix design does not consider VMA. By considering the Marshall stability and flow as the criteria instead of design factors, the modified Marshall mix design is able to decrease the errors occurred in Marshall stability test The test was performed to compare the Marshall properties between current and modified Marshall mix design. The left results showed that there was no difference in the Marshall properties, except for VTM. Thus, the modified Marshall mix design can produce the asphalt mixtures with the constant VTM (4%), and it can improve the asphalt mixture quality in Korea.

  • PDF

Evaluation of the Accuracy of Distance Measurements on 3D Volume-rendered Image of Human Skull Using Multi-detector CT: Effects of Acquisition Section Thickness and Reconstruction Section Thickness

  • Haijo Jung;Kim, Hee-Joung;Lee, Sang-Ho;Kim, Dong-Wook;Soonil Hong;Kim, Dong-Hyeon;Son, Hye-Kyung;Wonsuk Kang;Kim, Kee-Deog
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2002.09a
    • /
    • pp.457-460
    • /
    • 2002
  • The image quality of three-dimensional (3D) images has been widely investigated by the qualitative analysis method. A need remains for an objective and quantitative method to assess the image quality of 3D volume-rendered images. The purpose of this study was to evaluate the quantitative accuracy of distance measurements on 3D volume-rendered images of a dry human skull by using multi-detector computed tomography (MDCT). A radiologist measured five times the twenty-one direct measurement line items composed among twelve reference points on the skull surface with a digital vernier caliper. The water filled skull specimen was scanned with a MDCT according to the section thicknesses of 1.25, 2.50, 3.75, and 5.00 mm for helical (high quality; pitch 3:1) scan mode. MDCT data were reconstructed with its acquisition section thickness and with 1.25 mm section thickness for all scans. An observer also measured seven times the corresponding items on 3D volume-rendered images with measuring tools provided by volumetric analysis software. The quantitative accuracy of distance measurements on the 3D volume-rendered images was statistically evaluated (p-value < 0.05) by comparatively analyzing these measurements with the direct distance measurements. The accuracy of distance measurements on the 3D volume-rendered MDCT images acquired with 1.25, 2.50, 3,75 and 5.00 mm section thickness and reconstructed with its section thickness were 48%, 33%, 23%, and 14%, respectively. Meanwhile, there were insignificant statistical differences in accuracy of distance measurements among 3D volume-rendered images reconstructed with 1.25 mm section thickness for the each acquisition section thickness. MDCT images acquired with thick section thickness and reconstructed with thin section thickness in helical scan mode should be effectively used in medical planning of 3D volume-rendered images. The quantitative analysis of distance measurement may be a useful tool for evaluating the quantitative accuracy and the defining optimal parameters of 3D volume-rendered CT images.

  • PDF

Load Sharing Ratios Between the Cortex and Centrum in a Lumbar Vertebral Body with aging using Finite Element Method (유한 요소 법을 이용한 노화에 따른 요추의 피질 골과 해면 골 간의 하중 분담 비율)

  • Lim, JongWan
    • Journal of Biomedical Engineering Research
    • /
    • v.37 no.2
    • /
    • pp.90-103
    • /
    • 2016
  • This research was aimed to analyze load sharing ratios between cortical shell and trabecular bone of a degraded lumbar vertebra with aging, and also evaluate elastic moduli assigned into an FE model, using finite element method. For the better analysis of trabecular bone, effective elastic moduli, that is, nominal elastic moduli divided by the volumetric porosities was used. The elastic moduli of the cortical shell suitable for the trabecular bone were obtained from the equations on the basis of idealized stress-strain relations, including areal porosities. To minimize numerical errors, p-element was used. Using eight parameters that refer to some published papers, the geometry of L3 with a removed posterior part. After the constant compressive displacement was applied, the load sharing ratios were obtained by using both every elastic strain energy and every vertical force between two bones in each 8-volume. As results, 1) according to an increase in age from 20-year to 80-year, load sharing ratios of trabecular bone decreased from 55% to 49%; 2) the maximal ratios of each bone were occurred in the mid-plane of centrums and the endplate of cortical shells, respectively; 3) effective elastic moduli assigned into a porous centrum/cortex were found to be adequate; 4) for load sharing ratios, the difference of two methods showed that the total ratios were almost same within less than 1% but the partial ratios at every depth were more or less different each other.

Evaluation on the Possibility of Preparation of Nanosized Alumina Powder under W/O Emulsion Method Using Homogenizer (Homogenizer를 사용한 W/O 에멀젼법하에 나노크기 알루미나 분체 제조 가능성 평가)

  • Lee, Yoong;Hahm, Yeong-Min
    • Applied Chemistry for Engineering
    • /
    • v.21 no.5
    • /
    • pp.488-494
    • /
    • 2010
  • Under W/O emulsion method using a homogenizer, ${\alpha}$-alumina powder was prepared to evaluate the effects of experimental conditions on its properties, such as particle shape, extent of aggregation, average particle size and distribution. The experimental parameters were the change of type, quantity and composition of emulsifiers as well as the change of O : W volumetric ratio and agitation rate. As results, in the case of the use of single surfactant of SP80, sphere-like particles could be prepared and the average particle size was hardly affected by the agitation speed more than 16000 rpm regardless of SP80 quantity used. When the extent of aggregation among sphere-like particles prepared using $HLB_m$ = 5 of [SP80 & TW80] was compared with that prepared using SP80 at the same vol% surfactant and agitation speed, the former showed more or less low aggregation phenomena and average particle size was slightly reduced. In addition, the fraction of nano-sized particles with low aggregation was increased by the use of 0.1 vol% n-butanol, as a co-surfactant, with $HLB_m$ = 5 of [SP80 & TW80].

Proposal for Ignition Source and Flammable Material Safety Management through 3D Modeling of Hazardous Area: Focus on Indoor Mixing Processes (폭발위험장소 구분도의 3D Modeling을 통한 점화원 및 가연물 안전관리 방안 제안: 실내 혼합공정을 중심으로)

  • Hak-Jae Kim;Duk-Han Kim;Young-Woo Chon
    • Journal of the Society of Disaster Information
    • /
    • v.20 no.1
    • /
    • pp.47-59
    • /
    • 2024
  • Purpose: This study aims to propose measures for the prevention of fire and explosion accidents within manufacturing facilities by improving the existing classification criteria for hazardous locations based on the leakage patterns of flammable liquids. The objective is to suggest ways to safely manage ignition sources and combustible materials. Method: The hazardous locations were calculated using "KS C IEC 60079-10-1," and the calculated explosion hazard distances were visualized in 3D. Additionally, the formula for the atmospheric dispersion of flammable vapors, as outlined in "P-91-2023," was utilized to calculate the dispersion rates within the hazardous locations represented in 3D. Result: Visualization of hazardous locations in 3D enabled the identification of blind spots in the floor plan, facilitating immediate recognition of ignition sources within these areas. Furthermore, when calculating the time taken for the Lower Explosive Limit (LEL) to reach within the volumetric space of the hazardous locations represented in 3D, it was found that the risk level did not correspond identically with the explosion hazard distances. Conclusion: Considering the atmospheric dispersion of flammable liquids, it was concluded that safety management should be conducted. Therefore, a method for calculating the concentration values requiring detection and alert based on realistically achievable ventilation rates within the facility is proposed.

Development of New 4D Phantom Model in Respiratory Gated Volumetric Modulated Arc Therapy for Lung SBRT (폐암 SBRT에서 호흡동조 VMAT의 정확성 분석을 위한 새로운 4D 팬텀 모델 개발)

  • Yoon, KyoungJun;Kwak, JungWon;Cho, ByungChul;Song, SiYeol;Lee, SangWook;Ahn, SeungDo;Nam, SangHee
    • Progress in Medical Physics
    • /
    • v.25 no.2
    • /
    • pp.100-109
    • /
    • 2014
  • In stereotactic body radiotherapy (SBRT), the accurate location of treatment sites should be guaranteed from the respiratory motions of patients. Lots of studies on this topic have been conducted. In this letter, a new verification method simulating the real respiratory motion of heterogenous treatment regions was proposed to investigate the accuracy of lung SBRT for Volumetric Modulated Arc Therapy. Based on the CT images of lung cancer patients, lung phantoms were fabricated to equip in $QUASAR^{TM}$ respiratory moving phantom using 3D printer. The phantom was bisected in order to measure 2D dose distributions by the insertion of EBT3 film. To ensure the dose calculation accuracy in heterogeneous condition, The homogeneous plastic phantom were also utilized. Two dose algorithms; Analytical Anisotropic Algorithm (AAA) and AcurosXB (AXB) were applied in plan dose calculation processes. In order to evaluate the accuracy of treatments under respiratory motion, we analyzed the gamma index between the plan dose and film dose measured under various moving conditions; static and moving target with or without gating. The CT number of GTV region was 78 HU for real patient and 92 HU for the homemade lung phantom. The gamma pass rates with 3%/3 mm criteria between the plan dose calculated by AAA algorithm and the film doses measured in heterogeneous lung phantom under gated and no gated beam delivery with respiratory motion were 88% and 78%. In static case, 95% of gamma pass rate was presented. In the all cases of homogeneous phantom, the gamma pass rates were more than 99%. Applied AcurosXB algorithm, for heterogeneous phantom, more than 98% and for homogeneous phantom, more than 99% of gamma pass rates were achieved. Since the respiratory amplitude was relatively small and the breath pattern had the longer exhale phase than inhale, the gamma pass rates in 3%/3 mm criteria didn't make any significant difference for various motion conditions. In this study, the new phantom model of 4D dose distribution verification using patient-specific lung phantoms moving in real breathing patterns was successfully implemented. It was also evaluated that the model provides the capability to verify dose distributions delivered in the more realistic condition and also the accuracy of dose calculation.

Development of a Solar Collector Performance of Cylindrical Parabolic Concentrating Solar Collector (태양열(太陽熱) 집열기개발(集熱器開發)에 관(關)한 연구(硏究) - 포물반사곡면(抛物反射曲面)으로된 2차원(二次元) 집광식(集光式) 태양열(太陽熱) 집열기(集熱器)의 성능분석(性能分析) -)

  • Song, Hyun Kap;Yon, Kwang Seok;Cho, Sung Chan
    • Journal of Biosystems Engineering
    • /
    • v.10 no.1
    • /
    • pp.54-68
    • /
    • 1985
  • It is desirable to collect the solar thermal energy at relatively high temperature in order to minimize the size of thermal storage system and to enlarge the scope of solar thermal energy utilization. So far the concentrating solar collector has been developed to collect solar thermal energy at relatively high temperature, but it has some difficulties in maintaining the volumetric body of solar collector for long term utilization. On the other hand, the flat-plate solar collector has been developed to collect the solar thermal energy at low temperature, and it has advantages in maintaining the system for long term utilization, since it's thickness is thin and not volumetric. In this study, to develop a solar collector that has both advantages of collecting solar thermal energy at high temperature and fixing conveniently the collector system for long term period, a cylindrical parabolic concentrating solar collector was designed, which has two rows of parabolic reflectors and thin thickness such as the flat-plate solar collector, maintaining the optical form of concentrating solar collector. The characteristics of the concentrating parabolic solar collector newly designed was analysed and the results are summarized as follows; 1. The temperature of the air enclosed in solar collector was all the same as $50^{\circ}C$ in both cases of the open and closed loop, and when the heat transfer fluid was not circulated in tubular absorber, the maximum surface temperature of the absorber was $118-120^{\circ}C$, this results suggested that the heat transfer fluid could be heated up to $118^{\circ}C$. 2. In case of longitudinal installation of the solar collector, the temperature difference of heat transfer fluid between inlet and outlet was $4^{\circ}-6^{\circ}C$ at the flow rate of $110-130{\ell}/hr$, and the collected solar energy per unit area of collector was $300-465W/m^2$. 3. The collected solar energy per unit area for 7 hours was 1960 Kcal/$m^2$ for the open loop and 220 Kcal/$m^2$ for the closed loop. Therefore it is necessary to combine the open and closed loop of solar collectors to improve the thermal efficiency of solar collector. 4. The thermal efficiency of the solar collector (C.P.C.S.C.) was proportional to the density of solar radiation, indicating the maximum thermal efficiency ${\eta}_{max}=58%$ with longitudinal installation and ${\eta}_{max}=45%$ with lateral installation. 5. The thermal efficiency of the solar collector (C.P.C.S.C.) was increased in accordance with the increase of flow rate of heat transfer fluid, presenting the flow rate of $110{\ell}/hr$ was the value of turning point of the increasing rate of the collector efficiency, therefore the flow rate of $110{\ell}/hr$ was considered as optimum value for the test of the solar collector (C.P.C.S.C.) performance when the heat transfer fluid is a liquid. 6. In both cases of longitudinal and lateral installation of the solar collector (C.P.C.S.C.), the thermal efficiency was decreased linearly with an increase in the value of the term ($T_m-T_a$)/Ic and the increasing rate of the thermal efficiency was not effected by the installation method of solar collector.

  • PDF

Evaluation of the Accuracy for Respiratory-gated RapidArc (RapidArc를 이용한 호흡연동 회전세기조절방사선치료 할 때 전달선량의 정확성 평가)

  • Sung, Jiwon;Yoon, Myonggeun;Chung, Weon Kuu;Bae, Sun Hyun;Shin, Dong Oh;Kim, Dong Wook
    • Progress in Medical Physics
    • /
    • v.24 no.2
    • /
    • pp.127-132
    • /
    • 2013
  • The position of the internal organs can change continually and periodically inside the body due to the respiration. To reduce the respiration induced uncertainty of dose localization, one can use a respiratory gated radiotherapy where a radiation beam is exposed during the specific time of period. The main disadvantage of this method is that it usually requests a long treatment time, the massive effort during the treatment and the limitation of the patient selection. In this sense, the combination of the real-time position management (RPM) system and the volumetric intensity modulated radiotherapy (RapidArc) is promising since it provides a short treatment time compared with the conventional respiratory gated treatments. In this study, we evaluated the accuracy of the respiratory gated RapidArc treatment. Total sic patient cases were used for this study and each case was planned by RapidArc technique using varian ECLIPSE v8.6 planning machine. For the Quality Assurance (QA), a MatriXX detector and I'mRT software were used. The results show that more than 97% of area gives the gamma value less than one with 3% dose and 3 mm distance to agreement condition, which indicates the measured dose is well matched with the treatment plan's dose distribution for the gated RapidArc treatment cases.

Assessment of Parameters Measured with Volumetric Pulmonary Artery Catheter as Predictors of Fluid Responsiveness in Patients with Coronary Artery Occlusive Disease (관상동맥 질환을 가진 환자에서 폐동맥카테터로 측정한 전부하 지표들은 수액부하 반응을 예상할 수 있는가?)

  • Lee, Ji-Yeon;Lee, Jong-Hwa;Shim, Jae-Kwang;Yoo, Kyung-Jong;Hong, Seung-Bum;Kwak, Young-Lan
    • Journal of Chest Surgery
    • /
    • v.41 no.1
    • /
    • pp.41-48
    • /
    • 2008
  • Background: Accurate assessment of the preload and the fluid responsiveness is of great importance for optimizing cardiac output, especially in those patients with coronary artery occlusive disease (CAOD). In this study, we evaluated the relationship between the parameters of preload with the changes in the stroke volume index (SVI) after fluid loading in patients who were undergoing coronary artery bypass grafting (CABG). The purpose of this study was to find the predictors of fluid responsiveness in order to assess the feasibility of using. certain parameters of preload as a guide to fluid therapy. Material and Method: We studied 96 patients who were undergoing CABG. After induction of anesthesia, the hemodynamic parameters were measured before (T1) and 10 min after volume replacement (T2) by an infusion of 6% hydroxyethyl starch 130/0.4 (10 mL/kg) over 20 min. Result: The right ventricular end-diastolic volume index (RVEDVI), as well as the central venous pressure (CVP) and pulmonary capillary wedge pressure (PCWP), failed to demonstrate significant correlation with the changes in the SVI (%). Only the right ventricular ejection fraction (RVEF) measured at T1 showed significant correlation. with the changes of the SVI by linear regression (r=0.272, p=0.017). However, when the area under the curve of receiver operating characteristics (ROC) was evaluated, none of the parameters were over 0.7. The volume-induced increase in the SVI was 10% or greater in 31 patients (responders) and under 10% in 65 patients (non-responders). None of the parameters of preload measured at T1 showed a significant difference between the responders and non-responders, except for the RVEF. Conclusion: The conventional parameters measured with a volumetric pulmonary artery catheter failed to predict the response of SVI following fluid administration in patients suffering with CAOD.