• Title/Summary/Keyword: Volumetric Heat Sink

Search Result 5, Processing Time 0.035 seconds

Design of Cooling System of Over-molding Mold for Socket Component of Automobile Wiper (자동차 와이퍼 소켓 부품 제작용 오버몰딩 금형의 냉각 시스템 설계)

  • Lee, Dong-Gi;Park, Min-Woo;Ahn, Dong-Gyu
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.35 no.12
    • /
    • pp.1635-1640
    • /
    • 2011
  • The objective of this study is to design of a cooling system of the over-molding mold for a socket component of an automobile wiper by performing numerical analyses. Hot spots in which the temperature distributions are higher than those of other region, were estimated by an initial over-molding analysis for the initial design of the mold. On the basis of the initial over-molding analysis, two types of cooling system designs with a linear cooling channel and a volumetric heat sink, were considered to improve the cooling characteristics of hot spots. To obtain an appropriate cooling system design, the effects of the diameter and the position of the linear cooling channels on the cooling characteristics and the product qualities were quantitatively examined. In addition, the effects of the design of the volumetric heat sink on the cooling characteristics and deformation distributions in the molded product were investigated. The results of the over-molding analysis of the two types of cooling systems showed that the multi-sliced over-molding mold with a volumetric heat sink can improve both the product quality and the cooling characteristics of the mold.

A Study on the Design of a Fan-Sink Considering the Flow Fields Behind the Fan Outlet (홴 후방 유동장을 고려한 홴싱크 설계에 관한 연구)

  • Jo, Jin-Su;Han, Seung-Ho;Han, Cheol-Hui
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.26 no.8
    • /
    • pp.1055-1061
    • /
    • 2002
  • A numerical and experimental study on the flow fields behind the fan outlet was carried out to improve the performance of a conventional fan-sink(fan and heat sink). Conventional fan-sinks have a heat sink of which fin configurations tend to increase the flow resistance, thus decreasing the performance and the cooling capabilities of a fan-sink. Lifting surface method is used for the prediction of flow fields behind the fan outlet. Oil-dot flow visualization technique is applied for the validation of numerical results. The numerical results and experimental data show agreement each other. A conventional heat sink is modified and redesigned using flow patterns behind the fan outlet. The newly designed heat sink has the configuration of curved fins which minimize flow resistance. It showed improvements in both cooling: capabilities and volumetric flow rate compared to the conventional one.

Integral effect test for steam line break with coupling reactor coolant system and containment using ATLAS-CUBE facility

  • Bae, Byoung-Uhn;Lee, Jae Bong;Park, Yu-Sun;Kim, Jongrok;Kang, Kyoung-Ho
    • Nuclear Engineering and Technology
    • /
    • v.53 no.8
    • /
    • pp.2477-2487
    • /
    • 2021
  • To improve safety analysis technology for a nuclear reactor containment considering an interaction between a reactor coolant system (RCS) and containment, this study aims at an experimental investigation on the integrated simulation of the RCS and containment, with an integral effect test facility, ATLAS-CUBE. For a realistic simulation of a pressure and temperature (P/T) transient, the containment simulation vessel was designed to preserve a volumetric scale equivalently to the RCS volume scale of ATLAS. Three test cases for a steam line break (SLB) transient were conducted with variation of the initial condition of the passive heat sink or the steam flow direction. The test results indicated a stratified behavior of the steam-gas mixture in the containment following a high-temperature steam injection in prior to the spray injection. The test case with a reduced heat transfer on the passive heat sink showed a faster increase of the P/T inside the containment. The effect of the steam flow direction was also investigated with respect to a multi-dimensional distribution of the local heat transfer on the passive heat sink. The integral effect test data obtained in this study will contribute to validating the evaluation methodology for mass and energy (M/E) and P/T transient of the containment.

Experimental Study on the Development of Food Drying Machine for Home Use Using Low Electricity (저전력 가정용 식품건조기 개발에 관한 실험적 연구)

  • Kim, Soon-Ho;Kim, Ki-Wan;Kim, Hoon
    • Journal of Power System Engineering
    • /
    • v.19 no.4
    • /
    • pp.43-49
    • /
    • 2015
  • This study has been analyzed and investigated the possibility for the substitution of a heat source with the application of PTC(Positive Temperature Coefficient Heater) in a food drying machine. And this experiment was conducted to measure temperatures at the upper part of the vessel and the heat sink. And the structure has the many holes plane connected with the external air in the upper part of similar volumetric vessel, and attached to the PTC heater (3sets) of total consumption electricity of 120[W] in Al radiant heat structure and the small fan (2sets) in the suitable space of the lower part. Consequently, it was found that at the most conditions of food drying test with the seven holes(5mm) under the control temperature $62^{\circ}C$, the optimum drying condition formatted and the optimum time range especially appeared from 6,500 second to 7,000 second in case of drying test on banana sample.