• Title/Summary/Keyword: Volume quantification

Search Result 141, Processing Time 0.031 seconds

Determining Potassium Bromate in the Inhalable Aerosol Fraction in Workplace Air with Ion Chromatography

  • Kowalska, Joanna;Lis, Monika;Biesaga, Magdalena
    • Safety and Health at Work
    • /
    • v.12 no.2
    • /
    • pp.209-216
    • /
    • 2021
  • Background: The article presents the results of studies performed in order to develop a new method of airborne potassium bromate(V) determination at workplaces. Methods: The method is based on a collection of the inhalable fraction of potassium bromate(V) using the IOM Sampler, then extraction of bromates with deionized water and chromatographic analysis of the obtained solution. The analysis was performed using ion chromatography with conductometric detection. The tests were performed on a Dionex IonPac®AS22 analytic column (250 × 4 mm, 6 ㎛) with AG22 precolumn (50 × 4 mm 11 ㎛). Results: The method provides for potassium bromate(V) determination within the concentration range of 0.043 ÷ 0.88 mg/m3 for an air sample of 0.72 m3 in volume, i.e., 0.1-2 times the exposure limit value as proposed in Poland. The method was validated in accordance with PN-EN 482. The obtained validation data are as follows: measuring range: 3.1-63.4 ㎍/mL, limit of detection (LOD) = 0.018 ㎍/mL and limit of quantification (LOQ) = 0.053 ㎍/mL. The developed method has been tested in the work environment, on laboratory employees having contact with potassium bromate(V). Conclusion: The analytical method allowed the determination of the inhalable fraction of airborne potassium bromate(V) at workplaces and can be used to assess occupational exposure.

Development and validation of an analytical method to quantify baphicacanthin A by LC-MS/MS and its application to pharmacokinetic studies in mice

  • Jeon, So Yeon;Kim, San;Park, Jin-Hyang;Song, Im-Sook;Han, Young Taek;Choi, Min-Koo
    • Analytical Science and Technology
    • /
    • v.35 no.2
    • /
    • pp.60-68
    • /
    • 2022
  • In this study, we developed and validated a sensitive analytical method to quantify baphicacanthin A in mouse plasma using liquid chromatography-tandem mass spectrometry (LC-MS/MS). The standard calibration curves for baphicacanthin A ranged from 0.5 to 200 ng/mL and were linear, with an r2 of 0.985. The inter- and intra-day accuracy and precision and the stability fell within the acceptance criteria. Besides, we investigated the pharmacokinetics of baphicacanthin A following its intravenous (5 mg/kg) and oral administration (30 mg/kg). Intravenously injected baphicacanthin A showed biphasic elimination kinetics with high clearance and volume of distribution values. Furthermore, baphicacanthin A showed a rapid absorption but low aqueous solubility (182.51±0.20 mg/mL), resulting in low plasma concentrations and low oral bioavailability (2.49 %). Thus, we successfully documented the pharmacokinetic properties of baphicacanthin A using this newly developed sensitive LC-MS/MS quantification method, which could be used in future lead optimization and biopharmaceutic studies.

4D flow MRI based flow visualization and quantification of bicuspid valvular flow using ex-vivo porcine model (4차원 자기공명영상을 활용한 돼지 심장 ex-vivo 이첨판 모델 유동 가시화 및 유동 특성 분석)

  • Minseong Kwon;Sungho Park;Hyungkyu Huh
    • Journal of the Korean Society of Visualization
    • /
    • v.21 no.1
    • /
    • pp.12-17
    • /
    • 2023
  • Aortic valve stenosis is a heart valve disease caused by the accumulation of calcium in the valve, which can divide into tricuspid aortic valve (TAV) stenosis and bicuspid aortic valve (BAV) stenosis depending on the shape of natural valve. In this study, pig heart-based TAV and BAV ex vivo models were fabricated, and the flow characteristics behind a valve were analyzed using 4D flow MRI. Flow behind normal TAV was uniformly distributed, while BAV asymmetrically opened with an eccentric strong jet. Especially, BAV ex vivo model exhibited a secondary flow in the region where the valve closed. In addition, BAV had a 26% higher peak velocity while maintaining similar stroke volume compared with normal TAV. This study would be helpful for understanding the flow characteristics for BAV AS patients.

Electrochemical Monitoring of NADH Redox with NPQD-modified Electrodes for Cell Viability Assessment

  • JuKyung Lee;Hye Bin Park;Chae Won Seo;Chae Won Seo;SangHee Kim
    • Journal of Sensor Science and Technology
    • /
    • v.32 no.6
    • /
    • pp.412-417
    • /
    • 2023
  • There is increasing interest in the rapid and highly sensitive monitoring of cell viability in biological and toxicological research. Conventional methods depend on optical assays using Water Soluble Tetrazolium-8 (WST-8) or 3-(4,5-dimethylthiazolyl-2)-2,5-diphenyltetrazolium bromide (MTT) assay, which requires a large volume of samples and special instruments, necessitating shipment of clinical samples to laboratories. This paper reports on the development of a rapid and sensitive electrochemical (EC) sensor using screen printed electrode (SPE) and surface modification using 4'-mercapto-N-phenylquinone diamine (4'-NPQD), as double electron mediators, for monitoring cell viability via the measurement of nicotinamide adenine dinucleotide (NADH). We used the sensor to observe the viability of MCF-7 and doxorubicin (Dox)-treated cells. The oxidation current of NADH was measured via chronoamperometry (CA), and the EC results showed a good linear relationship when compared with NADH quantification using WST-8 assay. The analysis time was only 10 s and limit of detection (LOD) of NADH was 1.78 µM. Our EC method has the potential to replace conventional WST assays for cell viability and cytotoxicity experiments.

Simultaneous HPLC Determination of Marker Compounds for the Standardization of Hedyotis diffusa (백운풀의 지표성분 설정 및 품질표준화를 위한 정량 분석법)

  • Bang, Han-Yeol;Yang, Eun-Ju;Kim, Jeong-Ah;Song, Kyung-Sik
    • Journal of Life Science
    • /
    • v.23 no.8
    • /
    • pp.1025-1031
    • /
    • 2013
  • From a 95% ethanolic extract of H. diffusa, four marker compounds (HD1~HD4) were isolated, which were relatively unique and exist in comparably high contents. The structures of marker compounds were identified as digitolutein (1), 2-hydroxy-3-methylanthraquinone (2), (E/Z)-6-O-p-coumaroyl scandoside methyl ester (4:1 mixture) (3), and (E/Z)-6-O-p-methoxycinnamoyl scandoside methyl ester (4:1 mixture) (4), respectively, on the basis of $^{13}C$ and $^1H$-NMR analyses. The calibration curves of marker compounds showed high linearity, as their correlation coefficient ($R^2$) were in the range of 0.9991~0.9999. In addition, the limit of detection (LOD) and the limit of quantification (LOQ) were $0.03{\sim}0.07{\mu}g/ml$ and $0.099{\sim}0.231{\mu}g/ml$, respectively. The intra-day/inter-day precision and accuracy were 0.23~2.00%/0.25~1.16% and 94.60~108.44%/94.73-110.23%, respectively. The optimal HPLC conditions for the simultaneous quantification of HD1~HD4 were as follows: stationary phase; Merck Chromolith RP-18e ($100{\times}4.6mm$, $5{\mu}m$), column temp.; room temperature, UV detection at 280 nm, flow rate; 2.0 ml/min, injection volume; $10{\mu}l$, mobile phase; start with the mixture of 80% solvent A ($H_2O$ containing 0.5% acetic acid) and 20% solvent B (methanol containing 0.5% acetic acid) and gradually decrease solvent A to 40% in 9 min., then retain this condition to 18 min. Under the HPLC condition, the four marker compounds 1~4 were successfully separated without any interference of other constituents. The results obtained in this study are expected to be helpful for the development of nutraceutics and natural medicines and for the quality control of this plant.

Comparison of Extraction Methods for Determination of Vitamin K1 in Vegetables (채소류의 비타민 K1 분석을 위한 추출방법의 비교)

  • Kim, Hyeongi;Choi, Youngmin;Cho, Young-Sook;Sung, Jeehye;Ham, Hyeonmi;Lee, Junsoo
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.43 no.11
    • /
    • pp.1791-1795
    • /
    • 2014
  • The objective of this study was to compare two extraction methods for determination of vitamin K1 (phylloquinone) in vegetables. In addition, analytical method validation parameters such as accuracy, precision, limit of detection (LOD), limit of quantification (LOQ), and linearity were calculated to ensure the method's validity. Vitamin K1 was quantified by reversed-phase HPLC using post-column derivatization and fluorescence detection ($Ex{\lambda}=243nm$, $Ex{\lambda}=430nm$). Higher analytical values were observed using solvent extraction compared to those from the enzyme extraction method. The results from the method validation showed high linearity in the calibration curve with a coefficient of correlation ($R^2$) of 0.9994. The LOD and LOQ were 0.1335 and 0.2784 ng/injection volume ($50{\mu}L$), respectively. The inter-day precision and inter-day precision were 2.0% and 2.1%, respectively. Overall recovery was close to 100% (n=5). The phylloquinone contents ranged from 9.42 to $1,212.57{\mu}g/100g$. Our study provides reliable data on the phylloquinone contents in commonly consumed vegetables in Korea.

Computed Tomography-Based Ventricular Volumes and Morphometric Parameters for Deciding the Treatment Strategy in Children with a Hypoplastic Left Ventricle: Preliminary Results

  • Goo, Hyun Woo;Park, Sang-Hyub
    • Korean Journal of Radiology
    • /
    • v.19 no.6
    • /
    • pp.1042-1052
    • /
    • 2018
  • Objective: To determine the utility of computed tomography (CT) ventricular volumes and morphometric parameters for deciding the treatment strategy in children with a hypoplastic left ventricle (LV). Materials and Methods: Ninety-four consecutive children were included in this study and divided into small LV single ventricle repair (SVR) (n = 28), small LV biventricular repair (BVR) (n = 6), disease-matched control (n = 19), and control (n = 41) groups. The CT-based indexed LV volumes, LV-to-right-ventricular (LV/RV) volume ratio, left-to-right atrioventricular valve (AVV) area ratio, left-to-right AVV diameter ratio, and LV/RV long dimension ratio were compared between groups. Proportions of preferred SVR in the small LV SVR group suggested by the parameters were evaluated. Results: Indexed LV end-systolic (ES) and end-diastolic (ED) volumes in the small LV SVR group ($6.3{\pm}4.0mL/m^2$ and $14.4{\pm}10.2mL/m^2$, respectively) were significantly smaller than those in the disease-matched control group ($16.0{\pm}4.7mL/m^2$ and $37.7{\pm}12.0mL/m^2$, respectively; p < 0.001) and the control group ($16.0{\pm}5.5mL/m^2$ and $46.3{\pm}10.8mL/m^2$, respectively; p < 0.001). These volumes were $8.3{\pm}2.4mL/m^2$ and $21.4{\pm}5.3mL/m^2$, respectively, in the small LV BVR group. ES and ED indexed LV volumes of < $7mL/m^2$ and < $17mL/m^2$, LV/RV volume ratios of < 0.22 and < 0.25, AVV area ratios of < 0.33 and < 0.24, and AVV diameter ratios of < 0.52 and < 0.46, respectively, enabled the differentiation of a subset of patients in the small LV SVR group from those in the two control groups. One patient in the small LV biventricular group died after BVR, indicating that this patient might not have been a good candidate based on the suggested cut-off values. Conclusion: CT-based ventricular volumes and morphometric parameters can suggest cut-off values for SVR in children with a hypoplastic LV.

A Study on Liquified Petroleum Gas(LPG) Fuel Quantitative Method using Coriolis Mass Flowmeter (코리올리 질량유량계를 이용한 액화석유가스(LPG) 정량 측정 방법 연구)

  • Park, Tae-Seong;Seong, Sang-Rae;Yim, Eui-Soon;Lee, Joung-Min;Lee, Myung-Sig;Kang, Hyung-Kyu
    • Journal of the Korean Institute of Gas
    • /
    • v.22 no.6
    • /
    • pp.109-122
    • /
    • 2018
  • Domestic LPG meters are being tested for LPG quantification in accordance with the "Measures Act". The LPG meter is re-tested every three years in accordance with the "Enforcement Decree of the Measures Act". The maximum permissible error within the test is within ${\pm}1.0%$, and the tolerance is within ${\pm}1.5%$. For the quantitative measurement of LPG, a hydrometer for LPG, a balance, and a pressure vessel are used. The volume of LPG varies in depending on the temperature and pressure. The current quantitative measurement method of LPG requires the measurement of temperature, pressure and density in order to determine the volume of LPG, respectively, and some equipments are needed accordingly. Coriolis mass flowmeter, on the other hand, measure the mass flow, density and temperature at the same time, and can be converted and calculated to the required values using a computer program, also it is widely applied in the industrial field. In this study, the volume of LPG was measured using a Coriolis mass flowmeter as a basic study of LPG quantitative measurement. In addition, it is shown that it is possible to apply for the LPG quantitative measurement using the Coriolis mass flowmeter by comparing it with the conventional LPG quantitative measurement method.

Determination of Phosphatidylcholine in Korea Functional Foods Containing Lecithins using HPLC with Evaporative Light-Scattering Detector (ELSD) (ELSD를 이용한 레시틴중의 포스파티딜콜린의 분석)

  • Lee Chang-Hee;Bahn Kyeong-Nyeo;Cho Tae-Yong;Lee Ju-Yeon;Lee Young-Ja;Chae Gae Yong
    • Journal of Food Hygiene and Safety
    • /
    • v.20 no.4
    • /
    • pp.267-271
    • /
    • 2005
  • Lecithin is a naturally occurring group of phospholipids found in nearly every living cell and has been widely used as the ingredient of functional foods. Lecithin has high content of phosphatidylcholine(PC), pharmaceutical material which promotes metabolism through the cell membrane. This study was carried out to improve the present inconvenient analytical method of PC in law for health & functional foods. The commodities used in this experiment, were two kinds of egg yolk and eight kinds of soybean lecithin functional foods. PC was separated with isocratic elution with hexane : isopropanol : D.W (30:60:8) through silica column (2.1$\times$150 mm) by HPLC with Evaporative Light-Scattering Detector (ELSD). The flow rate of the eluent was 0.5 ml/mim and infect volume was 10ul. The neubilizer temperature of detector was $60^{\circ}C$, drift tube temperature of that was $75^{\circ}C$ and gas flow was 30 psi. Quantification was carried out by external standardization. Limit of quantification was 0.15ppm. Lecithin contents of egg yolk and soybean Products were > $66\%$ and > $81\%$), respectively. Phosphatidylcholine contents of egg yolk and soybean products were > $74\%$ and > $18\%$, respectively.

Simultaneous Analysis of Bangpungtongseong-san and Its Antioxidant Effect (방풍통성산의 동시분석 및 항산화 효능 연구)

  • Seo, Chang-Seob;Kim, Ohn Soon;Shin, Hyeun-Kyoo
    • Herbal Formula Science
    • /
    • v.21 no.2
    • /
    • pp.133-143
    • /
    • 2013
  • Objectives : We carry out the simultaneous quantification for quality control of four components in Bangpungtongseong-san (BPTSS) sample. In addition, we assessed the antioxidant effects of BPTSS sample. Methods : The used column for separation and analysis of four compounds was Luna C18 column and column oven temperature was maintained at $40^{\circ}C$. The mobile phase for simultaneous determination consisted of two solvent systems, 1.0% acetic acid in water and 1.0% acetic acid in acetonitrile. High performance liquid chromatography-photodiode array (HPLC-PDA) method for analysis was performed at a flow rate of 1.0 mL/min with PDA detection at 254 and 280 nm. The injection volume was 10 ${\mu}L$. The antioxidant activities of BPTSS were evaluated by measuring free radical scavenging activities on 2,2'-Azinobis-3-ethyl-benzothiazoline-6-sulfonic acid (ABTS) and 1-1-diphenyl-2-picrylhydrazyl (DPPH). The inhibitory effects on low-density lipoprotein (LDL) oxidation were evaluated by the formation of thiobarbituric acid relative substances (TBARS) and relative electrophoretic mobility (REM). Results : Calibration curves were acquired with $r^2{\geq}0.9999$. The values of limit of detection (LOD) and quantification (LOQ) were 0.06-0.29 ${\mu}g/mL$ and 0.20-0.98 ${\mu}g/mL$, respectively. The amounts of geniposide, liquiritin, baicalin, and glycyrrhizin in BPTSS were 5.06, 7.33, 27.56, and 7.81 mg/g, respectively. The BPTSS showed the radical scavenging activity in a dose-dependent manner. The concentration required for 50% reduction (RC50) against ABTS and DPPH radicals were 72.51 ${\mu}g/mL$ and 128.49 ${\mu}g/mL$. Furthermore, GMGHT reduced the oxidation properties of LDL induced by CuSO4. Conclusions : The established HPLC-PDA method will be helpful to improve quality control of BPTSS. In addition, BPTSS has potentials as therapeutic agent on anti-atherosclerosis.