• Title/Summary/Keyword: Volume determination

Search Result 531, Processing Time 0.031 seconds

A Study on Determination of Boron Makeup Flow Rate During the Load Follow Operation (부하추종 운전시 보론 보충 수량 결정에 관한 연구)

  • Song, Yong-Mann;Lee, Un-Chul;Chung, Chang-Hyun
    • Nuclear Engineering and Technology
    • /
    • v.20 no.1
    • /
    • pp.1-8
    • /
    • 1988
  • During power plant operation, the flow rate from the CVCS makeup system is estimated using the continuity equation and mass balance equation, when the primary loop boron concentration change is required due to the power transient. For this purpose, primary loop, pressurizer and VCT(volume control tank)(in CVCS) are modeled by three control volumes which contain each mass and boron concentration. Connecting pipes between primary loop, pressurizer and CVCS are also modeled by time delay. Calculation for 14-2-6-2 (power 100-50-100) load follow case (at EOL, for KNU 7) is made using these models.

  • PDF

Determination of Maintenance Factor for Freeway Lighting Luminaires According Traffic Volume (교통량을 고려한 고속도로 조명기구의 보수율 산정법)

  • 여인선
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.12 no.2
    • /
    • pp.1-6
    • /
    • 1998
  • It is required to determine proper values for the maintenance factor according to traffic volume in the freeway lighting design. This paper presents a simple method to seperate of the effect of surrounding environment and that of traffic volume, which is based on the IESNA treatment with additional assumptions on their effects. Furthermore, it is found that prevailing concept for the maintenance factor does not necessarily yield a proper value for light loss factor, so that an additional factor of 0.9 should be included as an equipment factor.factor.

  • PDF

Simulation of Aggregate Slump Test Using Equivalent Sphere Particle in DEM (등가 구형입자를 이용한 DEM에서의 골재 슬럼프 실험 모사)

  • Yun, Tae Young;Ahn, Sang Hyeok;Nam, Jueong Hee;Yoo, Pyeong Jun
    • International Journal of Highway Engineering
    • /
    • v.15 no.5
    • /
    • pp.21-29
    • /
    • 2013
  • PURPOSES: Simulation of aggregate slump test using equivalent sphere particle in DEM and its validity evaluation against lab aggregate slump test METHODS : In this research, aggregate slump tests are performed and compared with DEM simulation. To utilize spheric particles in YADE, equivalent sphere diameter concept is applied. As verification measures, the volume in slump cone filled with aggregate is used and it is compared with volume in slump cone filled with equivalent sphere particle. Slump height and diameter are also used to evaluate the suggested numerical method with equivalent concept RESULTS : Simulation test results show good agrement with lab test results in terms of loose packing volume, height and diameter of slumped particle clump. CONCLUSIONS : It is concluded that numerical simulation using DEM is applicable to evaluate the effect of aggregate morphological property in loose packing and optimum gradation determination based on the aggregate slump test simulation result.

A Study on an Earthwork Calculation for Reclamation of the Harbor (해안매립을 위한 토공량 산정에 관한 연구)

  • Lee, Y.H;Mun, D.Y
    • Journal of Korean Port Research
    • /
    • v.11 no.2
    • /
    • pp.257-271
    • /
    • 1997
  • The calculation of earthwork plays a major role in plan or design of many civil engineering projects and thus it has become very important to advanced the accuracy of earthwork calculation. The purpose of this paper is to calculate the excavation volume of terrain using a proposal area formular in eathwork volume determination for reclamation of the harbor. A proposal area formular by first and third equation is compared with end area, middle area, prismoidal formula by trapezoidal, simpson formular to excavation volume for an experimental terrian $1\sim12$. As a result of this study, algorithm of a proposal area formula by prismoidal formula should provide a better accuracy than end area, middle area, prismoidal formula by trapezoidal formular, simpson formular.

  • PDF

Determination of the repair grout volume to fill voids in external post-tensioned tendons

  • Im, Seok Been;Hurlebaus, Stefan
    • Structural Engineering and Mechanics
    • /
    • v.42 no.1
    • /
    • pp.25-38
    • /
    • 2012
  • Recently, investigated failures of external post-tensioned (PT) tendons have called attention to the corrosion of strands in PT bridges, and the prevention of ongoing corrosion is required to secure their structural integrity. Since voids inside ducts can be a source for the ingress of water or deleterious chemicals, the vacuum grouting (VG) method and a volumeter for estimating amount of repair grouts were employed to fill voided ducts. However, the VG method is expensive and time-consuming for infield application because it requires an air-tight condition of entire ducts. Thus, latest research assessed three different repair grouting methods, and the pressure vacuum grouting (PVG) method was recommended in the field because it showed good filling capability in voided ducts and did not require an air-tight condition. Thus, a new method is required to estimate the volume of repair grouts because the PVG method is not applied in air-tight ducts. This research assesses the relationship between voided areas on ducts identified with soundings and required grout volume for repair using experimental results. The results show that the proposed equations and assumptions for estimating repair grout volume provide a sufficient amount of repair grouts for filling voided ducts.

Effect of Concentration and Surface Property of Silica Sol on the Determination of Particle Size and Electrophoretic Mobility by Light Scattering Method (광산란법에서 실리카 졸의 농도 및 표면특성이 입자 크기 및 전기영동 이동도 측정결과에 미치는 영향)

  • Cho, Gyeong Sook;Lee, Dong-Hyun;Kim, Dae Sung;Lim, Hyung Mi;Kim, Chong Youp;Lee, Seung-Ho
    • Korean Chemical Engineering Research
    • /
    • v.51 no.5
    • /
    • pp.622-627
    • /
    • 2013
  • Colloidal silica is used in various industrial products such as chemical mechanical polishing slurry for planarization of silicon and sapphire wafer, organic-inorganic hybrid coatings, binder of investment casting, etc. An accurate determination of particle size and dispersion stability of silica sol is demanded because it has a strong influence on surface of wafer, film of coatings or bulks having mechanical, chemical and optical properties. The study herein is discussed on the effect of measurement results of average particle size, sol viscosity and electrophoretic mobility of particle according to the volume fraction of eight types of silica sol with different size and surface properties of silica particles which are presented by the manufacturer. The measured particle size and the mobility of these sol were changed by volume fraction or particle size due to highly active surface of silica particle and change of concentration of counter ion by dilution of silica sol. While in case the measured sizes of small particles less than 60 nm are increased with increasing volume fraction, the measured sizes of larger particles than 60 nm are slightly decreased. The mobility of small particle such as 12 nm are decreased with increase of viscosity. However, the mobility of 100 nm particles under 0.048 volume fraction are increased with increasing volume fraction and then decreased over higher volume fraction.

Estimation of Body Weight Using Body Volume Determined from Three-Dimensional Images for Korean Cattle (한우의 3차원 영상에서 결정된 몸통 체적을 이용한 체중 추정)

  • Jang, Dong Hwa;Kim, Chulsoo;Kim, Yong Hyeon
    • Journal of Bio-Environment Control
    • /
    • v.30 no.4
    • /
    • pp.393-400
    • /
    • 2021
  • Body weight of livestock is a crucial indicator for assessing feed requirements and nutritional status. This study was performed to estimate the body weight of Korean cattle (Hanwoo) using body volume determined from three-dimensional (3-D) image. A TOF camera with a resolution of 640×480 pixels, a frame rate of 44 fps and a field of view of 47°(H)×37°(V) was used to capture the 3-D images for Hanwoo. A grid image of the body was obtained through preprocessing such as separating the body from background and removing outliers from the obtained 3-D image. The body volume was determined by numerical integration using depth information to individual grid. The coefficient of determination for a linear regression model of body weight and body volume for calibration dataset was 0.8725. On the other hand, the coefficient of determination was 0.9083 in a multiple regression model for estimating body weight, in which the age of Hanwoo was added to the body volume as an explanatory variable. Mean absolute percentage error and root mean square error in the multiple regression model to estimate the body weight for validation dataset were 8.2% and 24.5kg, respectively. The performance of the regression model for weight estimation was improved and the effort required for estimating body weight could be reduced as the body volume of Hanwoo was used. From these results obtained, it was concluded that the body volume determined from 3-D of Hanwoo could be used as an effective variable for estimating body weight.

Developing volume equation of street tree and its carbon stock for urban forest in Seoul (서울시 가로수의 재적식 개발 및 탄소저장량 평가)

  • Son, Yeong Mo;Kim, Kyeong Nam;Pyo, Jung Kee
    • Journal of agriculture & life science
    • /
    • v.50 no.1
    • /
    • pp.95-104
    • /
    • 2016
  • The objective of this paper is to develop volume equation of street tree and its carbon stock for urban forest in Seoul. To develop the volume equation by major species in Seoul, data for street trees were obtained from four-species (e.g. Gingko biloba, Platanus occidentalis, Zelkova serrata, and Metasequoia glyptostroboides), which accounted for 79% all street trees in Seoul. This study used a variable based on diameter on breast height and four equation for calculating volume. The coefficient of determination, bias, and root mean square error were used to evaluate the precision of four equations. From these methods, the most suitable equations for Platanus occidentalis was aDb, the other was aD+bD2; coefficient of determination upper on 0.873. From the volume equation developed in this research, the estimated carbon stock were derived as about 33,760tC for four-species of urban forest in Seoul. The results of this paper offered volume equation and carbon stock that present growth information for street trees in urban forestry and these can be made available for evaluating the management for carbon in settlement.

Left Ventricle Segmentation Algorithm through Radial Threshold Determination on Cardiac MRI (심장 자기공명영상에서 방사형 임계치 결정법을 통한 좌심실 분할 알고리즘)

  • Moon, Chang-Bae;Lee, Hae-Yeoun;Kim, Byeong-Man;Shin, Yoon-Sik
    • Journal of KIISE:Software and Applications
    • /
    • v.36 no.10
    • /
    • pp.825-835
    • /
    • 2009
  • The advance in medical technology has decreased death rates from diseases such as tubercle, pneumonia, malnutrition, and hepatitis. However, death rates from cardiac diseases are still increasing. To prevent cardiac diseases and quantify cardiac function, magnetic resonance imaging not harmful to the body is used for calculating blood volumes and ejection fraction(EF) on routine clinics. In this paper, automatic left ventricle(LV) segmentation is presented to segment LV and calculate blood volume and EF, which can replace labor intensive and time consuming manual contouring. Radial threshold determination is designed to segment LV and blood volume and EF are calculated. Especially, basal slices which were difficult to segment in previous researches are segmented automatically almost without user intervention. On short axis cardiac MRI of 36 subjects, the presented algorithm is compared with manual contouring and General Electronic MASS software. The results show that the presented algorithm performs in similar to the manual contouring and outperforms the MASS software in accuracy.

Determination of Trace Amounts of Zirconium by Flotation - Spectrophotometric Method (부유 - 분광광도법에 의한 지르코늄의 극미량 측정)

  • Pourreza, N.;Parham, H.;Shiri, S.
    • Journal of the Korean Chemical Society
    • /
    • v.54 no.3
    • /
    • pp.283-286
    • /
    • 2010
  • A sensitive and reproducible method for the flotation-spectrophotometric determination of zirconium is reported. The method is based on the complex formation zirconium and xylenol orange (XO) which is floated in the interface of aqueous phase and n-hexane by vigorous shaking. By discarding the aqueous solution and n-hexane, the adsorbed complex on to the wall of a separating funnel was dissolved in a small volume of methanol solvent and its absorbance was measured at 429 nm. The effect of different parameters such as pH, concentrations of HCl, and XO, and volume of n-hexane flotation dissolvent, standing and shaking time were studied. The calibration curve was linear in the range of 7-120 ng $mL^{-1}$ of zirconium with a correlation coefficient of 0.9991. The limit of detection (LOD) was 5.8 ng $mL^{-1}$. The relative standard deviation (RSD) for seven replicate measurements of 50 and 110 ng $mL^{-1}$ of zirconium were 4.4 and 3.0%, respectively. The method was successfully applied to the determination of zirconium in water samples.