• Title/Summary/Keyword: Volume Velocity

Search Result 1,300, Processing Time 0.025 seconds

Run-out Modeling of Debris Flows in Mt. Umyeon using FLO-2D (FLO-2D 모형을 이용한 우면산 토석류 유동 수치모의)

  • Kim, Seungeun;Paik, Joongcheol;Kim, Kyung Suk
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.33 no.3
    • /
    • pp.965-974
    • /
    • 2013
  • Multiple debris flows occurred on July 27, 2012 in Mt. Umyeon, which resulted in 16 casualties and severe property demage. Accurate reproducing of the propagation and deposition of debris flow is essential for mitigating these disasters. Through applying FLO-2D model to these debris flows and comparing the results with field observations, we seek to evaluate the performance of the model and to analyse the rheological model parameters. Representative yield stress and dynamic viscosity back-calculated for the debris flows in the northern side of Mt. Umyeon are 1022 Pa and 652 $Pa{\cdot}s$, respectively. Numerical results obtained using these parameters reveal that deposition areas of debris flows in Raemian and Shindong-A regions are well reproduced in 63-85% agreement with the field observations. However, the propagation velocities of the flows are significantly underestimated, which is attributable to the inherent limitations of the model that can't take the entrainment of bed material and surface water into account. The debris flow deposition computed in Hyeongchon region where the entrainment is not significant appears to be in very good agreement with the field observation. The sensitivity study of the numerical results on model parameters shows that both sediment volume concentration and roughness coefficient significantly affect the flow thickness and velocity, which underscores the importance of careful selection of these model parameters in FLO-2D modeling.

Numerical Simulation of Flow Characteristics behind a Circular Patch of Vegetation using a Two-Dimensional Numerical Model (2차원 수치모형을 이용한 원형군락 하류의 흐름특성 수치모의)

  • Kim, Hyung Suk;Park, Moonhyeong
    • Journal of Korea Water Resources Association
    • /
    • v.48 no.11
    • /
    • pp.891-903
    • /
    • 2015
  • This paper presents numerical simulations of flow around a circular patch of vegetation using a depth-averaged two-dimensional numerical model which is capable of simulating flow structure in vegetated open channel. In order to account for vegetation effect, drag force terms are included in governing equations. Numerical simulations are conducted with various solid volume fractions (SVF). Flow passes through a circular patch and low velocity region, which is called wake region, is formed downstream of the patch. When SVF is larger than 0.08, a recirculation is observed. The location of the recirculation is moved further downstream as SVF decreases. Von-$K{\acute{a}}rm{\acute{a}}n$ vortex street is developed beyond the wake region due to interaction between two shear layers induced by a circular patch of vegetation. The vortex is developed as SVF is larger than 0.08, and the location of the vortex is consistent with the maximum of turbulence kinetic energy. The location of the peak of turbulence kinetic energy is moved further downstream as SVF decreases.

A Study on the Basic Characteristics of In-situ Soil Flushing Using Surfactant (계면활성제를 이용한 원위치 토양세정 기법 적용을 위한 기초 특성 연구)

  • 최상일;소정현;조장환
    • Journal of Soil and Groundwater Environment
    • /
    • v.7 no.4
    • /
    • pp.87-91
    • /
    • 2002
  • Lab scale batch and column tests were performed to investigate the treatability of petroleum contaminated soil using the in-situ soil flushing method. The pyrex column (4.5$\times$25 cm) was used to investigate optimal washing agent, surfactant concentration, mixing ratio, and inlet velocity. The miked surfactant of $POE_{14}$ and SDS were determined as ideal systems for the batch tests. From the results of preliminary tests, mixed surfactant was found to be more harmful for microorganisms. So $POE_{5}$ and $POE_{14}$ were chosen as the surfactant system for the batch study. The washing efficiency for the diesel contaminated soil was increased until 1 %, and decreased after l %. When applied as selected mixed surfactant, the ideal mixed ratio was recognized as 1:1. Therefore we selected miked surfactant $POE_{5}$ and $POE_{14}$, surfactant concentration 1%, and mixed ratio 1:1 for the remediation of diesel contaminated soil. In column tests, the total removal efficiency was improved as the flux of washing agent was increased. At the same pore volume, small flux showed better removal efficiency.

A Comparative Study for Estimation of Greenhouse Gas for Local Government`s Sustainable Transport (지속가능교통 평가를 위한 온실가스 배출량 산정 방법론의 지자체 적용 및 비교 연구)

  • Yu, Byeong-Yong;Bae, Sang-Hun;Han, Sang-Yong;Kim, Geon-Yeong
    • Journal of Korean Society of Transportation
    • /
    • v.29 no.5
    • /
    • pp.55-65
    • /
    • 2011
  • In effort to estimate sustainability of the transportation sector, this study conducts a comparative analysis of methodology suggested for measuring greenhouse gas emission. There are two approaches proposed by the UN IPCC: 1) top-down approach (TDA) based on the amount oil sales, and 2) bottom-up approach (BUA) utilizing the velocity of moving source and traffic volume data. The subject areas for analysis were selected based on research results by the Korea Transportation Institute that evaluate traffic sustainability of each local government. Gwacheon-si being one of the top ranked areas in sustainability, and Anseong-si being ranked at the 7th level were analyzed. By the tier 1 methodology, Gwacheon-si and Anseong-si are estimated to create 74,813ton/yr, and 584,125ton/yr of the greenhouse gas emission, respectively. The tier 3 methodology, however, estimates Gwacheon-si and Anseong-si to create 91,462ton/yr, and 163,801ton/yr of the emission, respectively. Comparison of the two estimated emissions shows considerable differences; i.e., the tier 3 method over estimates Gwacheon-si's emission by 22.3% whereas it underestimates Anseong-si's greenhouse gas emission by the factor of about 3.5 compared to the emissions obtained from the tier 1 method. The result from this study implies that the traffic-sustainability-index based grade of each local government can be evaluated differently by the method adopted for measuring greenhouse gas emission.

The Usability Evaluation of Application that is Developed the Dynamic Kidney Phantom System in Nuclear Medicine

  • Kim, Jae-Hyun;Lee, Juyoung;Park, Hoon-Hee
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.16 no.2
    • /
    • pp.15-24
    • /
    • 2014
  • Currently commercially available phantom can reproduce and evaluate only a static situation, the study is incomplete research on phantom and system which is can confirmed functional situation in the kidney by time through dynamic phantom and blood flow velocity, various difference according to the amount of radioactive. Therefore, through this study, it has produced the dynamic kidney phantom to reproduce images through the dynamic flow of the kidney, it desires to evaluate the usefulness of nuclear medicine imaging. The production of the kidney phantom was fabricated based on the normal adult kidney, in order to reproduce the dynamic situation based on the fabricated kidney phantom, in this study it was applied the volume pump that can adjust the speed of blood flow, so it can be integrated continuously radioactive isotopes in the kidney by using 99mTc-pertechnate. Used the radioactive isotope was supplied through the two pump. It was confirmed the changes according to the infusion rate, radioactive isotopes and the different injection speeds on the left and right, analysis of the acquired images was done by drawn five times ROI in order to check the reproducibility of each on the front and rear of the kidney and bladder. Depending on the speed of injection, radioisotope was a lot of integrated and emissions up when adjusting the pressure of the pump as 30 stroke, it was the least integrated and emissions up when adjusting as 40 stroke. The integration of the left & right kidney was not reached in the amount of the highest when adjusting as 10 stroke. In the changes according to the amount of the radioactive isotope, 0.6 mCi(22.2 MBq), 0.8 mCi (29.6 MBq)was showed up similar tendency but, in the result of the injection 0.8 mCi, it was showed up counts close to double of 0.6 mCi. In the result of the differently injection speed of the left & right kidney, as a result of different conditions that injection speed was 20 stroke through left kidney phantom, the injection speed was 30 stroke through right kidney phantom, it was enough difference in the resulting image can be easily distinguished with the naked eye. Through this study, the results showed that the dynamic kidney phantom system is able to similarly reproduce renogram in the actual clinical. Especially, the depicted over time for the flow to be excreted through the kidney into the bladder was adequately reproduce, it is expected to be utilized as basic data to check the quality of the dynamic images. In addition, it is considered to help in the field of functional imaging and quality control.

  • PDF

Microhabitat Analysis of Endangered Species (I), Cobitis choiiwith Rapid Decreases of Population by Environmental Pollution for a Habitat Replacement (환경오염에 의해 급감하는 멸종위기 1급 어종인 미호종개의 대체 서식지 마련을 위한 미소서식지 분석)

  • Kim, Jiyoon;An, Kwangguk
    • Journal of Environmental Impact Assessment
    • /
    • v.23 no.4
    • /
    • pp.271-284
    • /
    • 2014
  • The objectives of this research were to analyse the microhabitat of Cobitis choii which is designated as an endangered fish species (I) and national monument species in Korea (No. 454), and provide valuable information of suitable replacement habitat in the future for a conservation of the population with rapid decreases by environmental pollution. Sampling and microhabitat analysis in three streams such as Baekgok, Yugu and Gap Stream, known as one of the least habitats in Korea showed that the mean number of Cobitis choii observed was 2.6. This result indicated that the richness was too low, so the species conservation was very urgent. Optimal physical microhabitat of the population was determined as environmental conditions with > 60% sand with 1 mm particle size, optimal water depth of 20 - 60 cm in the habitats, and the optimal current velocity of < 0.4 m/s. Under the circumstances of the microhabitat, optimal water volume (discharge) was 0 - 2 m3/s in the each sectional analysis and this reach was mainly composed of the stream section with intermittant slow runs and pools. These microhabitats were largely disturbed by physical modifications of habitat and chemical pollutions due to direct influences of nutrient-rich water inputs from the urban area and intensive agricultural pollutants. For these reasons, optimal habitat replacement are required in the future for the conservation of the species.

Risk based policy at big data era: Case study of privacy invasion (빅 데이터 시대 위험기반의 정책 - 개인정보침해 사례를 중심으로 -)

  • Moon, Hyejung;Cho, Hyun Suk
    • Informatization Policy
    • /
    • v.19 no.4
    • /
    • pp.63-82
    • /
    • 2012
  • The world's best level of ICT(Information, Communication and Technology) infrastructure has experienced the world's worst level of ICT accident in Korea. The number of major accidents of privacy invasion has been three times larger than the total number of Internet user of Korea. The cause of the severe accident was due to big data environment. As a result, big data environment has become an important policy agenda. This paper has conducted analyzing the accident case of data spill to study policy issues for ICT security from a social science perspective focusing on risk. The results from case analysis are as follows. First, ICT risk can be categorized 'severe, strong, intensive and individual'from the level of both probability and impact. Second, strategy of risk management can be designated 'avoid, transfer, mitigate, accept' by understanding their own culture type of relative group such as 'hierarchy, egalitarianism, fatalism and individualism'. Third, personal data has contained characteristics of big data such like 'volume, velocity, variety' for each risk situation. Therefore, government needs to establish a standing organization responsible for ICT risk policy and management in a new big data era. And the policy for ICT risk management needs to balance in considering 'technology, norms, laws, and market'in big data era.

  • PDF

Hemodynamic Evaluation of Acute Mitral Valve Insufficiency Model induced by Chordae Tendinae Rupture in Normal Dogs (개에서 건삭파열로 유발한 급성 이첨판 폐쇄부전 모델의 혈류역학적 평가)

  • Kim, Sehoon;Kim, Nam-Soo;Lee, Ki-Chang;Kim, Jong Min;Kim, Min-Su
    • Journal of Veterinary Clinics
    • /
    • v.31 no.5
    • /
    • pp.367-370
    • /
    • 2014
  • The study was to observe hemodynamic alterations of cardiac function to design a model of canine mitral valve insufficiency (MVI) based on chordae tendinae rupture (CTR). Ten healthy beagles with normal heart function were used in this study. To measure hemodynamics, the patient monitor was equipped for invasive blood pressure and a Swan-Ganz catheter. Hemodynamic alterations were checked promptly during CTR procedures. MVI model was made by transection of the chordae tendinae with small arthroscopy hook knife through $5^{th}$ intercostal open chest. Color Doppler at the level of the mitral valve showed high-velocity regurgitant flow immediately after CTR at intraoperative echocardiography. In hemodynamic measurements, pulmonary capillary wedge pressure (PCWP) was significantly increased, while mean arterial pressure (MAP), venous pressure (VP), pulmonary arterial pressure (PAP), cardiac output (CO) and cardiac index (CI) were significantly decreased after CTR. It was known that the left atrium was overloaded by regurgitant volume from the left ventricle. In conclusion, the MVI model induced by CTR technique in this study should be used as suitable one for the effective research of canine mitral valve disease. Further study should be needed to measure the chronic alternation of mitral valve in the model.

The Method for Evaluating Unsaturated Hydraulic Conductivity of the Bentonite-buffer Using Relative Humidity (상대습도를 이용한 벤토나이트 완충재의 불포화 수리전도도 평가방안)

  • Lee, Hang-Bok;Kim, Jin-Seop;Choi, Young-Chul;Choi, Heui-Joo;Kim, Kyungsu
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.12 no.1
    • /
    • pp.69-77
    • /
    • 2014
  • Unsaturated hydraulic conductivity of the bentonite-buffer was evaluated using the relative humidity data. The method for calculating unsaturated hydraulic conductivity was deduced from the general analytical equation representing the movement of water in unsaturated media, which was applied to the experimental results of water infiltration tests for identifying the behavior of unsaturated hydraulic conductivity according to the water saturation. Unlike the saturated condition, the hydraulic gradient and water flux were irregularly changed, and the unsaturated hydraulic conductivity was increased with increasing the experimental time. Swelling of bentonite grains due to the water absorption increased the volume and size of pore within bentonite, resulting in the increase of water velocity and unsaturated hydraulic conductivity. This result suggested the necessity of further investigation on the correlation between the swelling degree of bentonite-buffer and unsaturated hydraulic conductivity. The method used in this study can be useful technique for evaluating long-term hydraulic performance of bentonite-buffer in the radioactive waste disposal system.

VOC/HAPs Emission Characteristics & Adsorption Evaluation for Paint Products in Busan Area (부산지역 페인트제조시설의 VOC/HAPs 배출특성 및 흡착능 평가)

  • Song, Bok-Joo;Lee, Seung-Min;Cho, Gab-Je;Cho, Jeong-Gu;You, Pyung-Jong;Kim, Gi-Gon
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.34 no.5
    • /
    • pp.316-325
    • /
    • 2012
  • In this study, we suggested adequate control technology by analyzing emission process and main chemical of VOC/HAPs generated from four paint factories in Busan area. And we estimated whether Kapok fiber, which is a natural material, can be commercially used for an absorbent by testing adsorption ability. As a result of this sturdy, above 60% of VOC/HAPs was volatilized and dispersed inside the working place without conducting control system of facilities during manufacturing paints. Concentration profile of VOC/HAPs, which is volatile naturally outside the factories, is surveyed above 70% at Toluene, Ethylbenzene, and Xylene. And a result of evaluation of odor attribution level about the component whose Odor Threshold is known, it is estimated that major cause material of A, B, C factories is Toluene and that of D factory is m/p-Xylene. And that result presented design arguments such as facilities specifications, activated carbon filling volume, and replace cycle of activated carbon as control technology. Also, that result presented emission process improvement such as adsorption of central-controlled ventilation device, installation of inlet flenge, and potable cleaning process. The rate of pollutant adsorption of Kapok fiber, which is natural material, is indicated about 91.9%, 66.7%. That result validated the possibility as replacement of activated carbon.