• Title/Summary/Keyword: Volume Reduction

Search Result 1,750, Processing Time 0.03 seconds

Development of an Oxide Reduction Process for the Treatment of PWR Spent Fuel (PWR 사용후핵연료 처리를 위한 금속전환공정 개발)

  • Hur, Jin-Mok;Hong, Sun-Seok;Jeong, Sang-Mun;Lee, Han-Soo
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.8 no.1
    • /
    • pp.77-84
    • /
    • 2010
  • Reduction of oxides has been investigated for the volume reduction and recycling of the spent oxide fuel from commercial nuclear power plants. Various oxide reduction methods were proposed and KAERI (Korea Atomic Energy Research Institute) is currently developing an electrochemical reduction process using a LiCl-$Li_2O$ molten salt as a reaction medium. The electrochemical reduction process, the front end of the pyroprocessing, can connect the PWR (Pressurized Water Reactor) oxide fuel cycle to a metal fuel cycle of the sodium cooled fast reactor. This paper summarizes KAERI efforts on the development, improvement, and scale-up of the oxide reduction process.

Casting Technology of an Aluminum Alloy Composite Brake Disc (알루미늄 복합재 제동디스크 주조 기술 개발)

  • Goo, Byeong-Choon;Kim, Myung-Ho
    • Proceedings of the KSR Conference
    • /
    • 2011.10a
    • /
    • pp.971-974
    • /
    • 2011
  • Aluminum matrix composites reinforced with SiC particles(AMC) are one of the candidate materials for the weight reduction of rolling stock brake discs. It is known that weight reduction of about 40% is possible when they replace conventional cast iron brake discs. But casting is not easy because of bad wettability of SiC with Al alloy. We developed two AMC brake discs with SiC volume fraction of 20% by a new casting method. It was found the developed method produced brake discs of good quality.

  • PDF

Evaluation of the Usefulness of Restricted Respiratory Period at the Time of Radiotherapy for Non-Small Cell Lung Cancer Patient (비소세포성 폐암 환자의 방사선 치료 시 제한 호흡 주기의 유용성 평가)

  • Park, So-Yeon;Ahn, Jong-Ho;Suh, Jung-Min;Kim, Yung-Il;Kim, Jin-Man;Choi, Byung-Ki;Pyo, Hong-Ryul;Song, Ki-Won
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.24 no.2
    • /
    • pp.123-135
    • /
    • 2012
  • Purpose: It is essential to minimize the movement of tumor due to respiratory movement at the time of respiration controlled radiotherapy of non-small cell lung cancer patient. Accordingly, this Study aims to evaluate the usefulness of restricted respiratory period by comparing and analyzing the treatment plans that apply free and restricted respiration period respectively. Materials and Methods: After having conducted training on 9 non-small cell lung cancer patients (tumor n=10) from April to December 2011 by using 'signal monitored-breathing (guided- breathing)' method for the 'free respiratory period' measured on the basis of the regular respiratory period of the patents and 'restricted respiratory period' that was intentionally reduced, total of 10 CT images for each of the respiration phases were acquired by carrying out 4D CT for treatment planning purpose by using RPM and 4-dimensional computed tomography simulator. Visual gross tumor volume (GTV) and internal target volume (ITV) that each of the observer 1 and observer 2 has set were measured and compared on the CT image of each respiratory interval. Moreover, the amplitude of movement of tumor was measured by measuring the center of mass (COM) at the phase of 0% which is the end-inspiration (EI) and at the phase of 50% which is the end-exhalation (EE). In addition, both observers established treatment plan that applied the 2 respiratory periods, and mean dose to normal lung (MDTNL) was compared and analyzed through dose-volume histogram (DVH). Moreover, normal tissue complication probability (NTCP) of the normal lung volume was compared by using dose-volume histogram analysis program (DVH analyzer v.1) and statistical analysis was performed in order to carry out quantitative evaluation of the measured data. Results: As the result of the analysis of the treatment plan that applied the 'restricted respiratory period' of the observer 1 and observer 2, there was reduction rate of 38.75% in the 3-dimensional direction movement of the tumor in comparison to the 'free respiratory period' in the case of the observer 1, while there reduction rate was 41.10% in the case of the observer 2. The results of measurement and comparison of the volumes, GTV and ITV, there was reduction rate of $14.96{\pm}9.44%$ for observer 1 and $19.86{\pm}10.62%$ for observer 2 in the case of GTV, while there was reduction rate of $8.91{\pm}5.91%$ for observer 1 and $15.52{\pm}9.01%$ for observer 2 in the case of ITV. The results of analysis and comparison of MDTNL and NTCP illustrated the reduction rate of MDTNL $3.98{\pm}5.62%$ for observer 1 and $7.62{\pm}10.29%$ for observer 2 in the case of MDTNL, while there was reduction rate of $21.70{\pm}28.27%$ for observer 1 and $37.83{\pm}49.93%$ for observer 2 in the case of NTCP. In addition, the results of analysis of correlation between the resultant values of the 2 observers, while there was significant difference between the observers for the 'free respiratory period', there was no significantly different reduction rates between the observers for 'restricted respiratory period. Conclusion: It was possible to verify the usefulness and appropriateness of 'restricted respiratory period' at the time of respiration controlled radiotherapy on non-small cell lung cancer patient as the treatment plan that applied 'restricted respiratory period' illustrated relative reduction in the evaluation factors in comparison to the 'free respiratory period.

  • PDF

Development of Respiratory Motion Reduction Device System (RMRDs) for Radiotherapy in Moving Tumor: Construction of RMRDs and Patient Setup Verification Program

  • Lee, Suk;Chu, Sung-Sil;Lee, Sei-Byung;Jino Bak;Cho, Kwang-Hwan;Kwon, Soo-Il;Jinsil Seong;Lee, Chang-Geol;Suh, Chang-Ok
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2002.09a
    • /
    • pp.86-89
    • /
    • 2002
  • The purpose is to develop a system to reduce the organ movement from the respiration during the 3DCRT or IMRT. This research reports the experience of utilizing personally developed system for mobile tumors. The patients clinical database was structured for 10 mobile tumors and patient setup error measurement and immobilization device effects were investigated. The RMRD system is composed of the respiratory motion reduction device utilized in prone position and abdominal strip device(ASD) utilized in the supine position, and the analysis program, which enables the analysis on patients setup reproducibility. Dose to normal tissue between patients with RMRDs and without RMRDs was analyzed by comparing the normal tissue volume, field margins and dose volume histogram(DVH) using fluoroscopy and CT images. And, reproducibility of patients setup verify by utilization of digital images. When patients breathed freely, average movement of diaphragm was 1.2 cm in prone position in contrast to 1.6 cm in supine position. In prone position, difference in diaphragm movement with and without RMRDs was 0.5 cm and 1.2 cm, respectively, showing that PTV margins could be reduced to as much as 0.7 cm. With RMRDs, volume of the irradiated normal tissue (lung, liver) reduced up to 20 % in DVH analysis. Also by obtaining the digital image, reproducibility of patients setup verify by visualization using the real-time image acquisition, leading to practical utilization of our software. Internal organ motion due to breathing can be reduced using RMRDs, which is simple and easy to use in clinical setting. It can reduce the organ motion-related PTV margin, thereby decrease volume of the irradiated normal tissue.

  • PDF

Twelve-Month Volume Reduction Ratio Predicts Regrowth and Time to Regrowth in Thyroid Nodules Submitted to Laser Ablation: A 5-Year Follow-Up Retrospective Study

  • Roberto Negro;Gabriele Greco;Maurilio Deandrea;Matteo Rucco;Pierpaolo Trimboli
    • Korean Journal of Radiology
    • /
    • v.21 no.6
    • /
    • pp.764-772
    • /
    • 2020
  • Objective: Laser ablation is a therapeutic modality used to reduce the volume of large benign thyroid nodules. Unsatisfactory reduction and regrowth are observed in some treated nodules. The aim of the study was to evaluate the long-term outcomes of laser treatment for solid nodules during a 5-year follow-up period, the regrowth rate, and the predictive risk factors of nodule regrowth. Materials and Methods: We retrospectively evaluated patients with benign, solid, cold thyroid nodules who underwent laser ablation and were followed-up for 5 years. According to the selection criteria, 104 patients were included (median baseline nodule volume, 12.5 mL [25.0-75.0%, 8-18 mL]; median energy delivered, 481.5 J/mL [25.0-75.0%, 370-620 J/mL]). Nodule volume, thyroid function test results, and ultrasound were evaluated at baseline and then annually after the procedure. Results: Of 104 patients, 31 patients (29.8%) had a 12-month volume reduction ratio (VRR) < 50.0% and 39 (37.5%) experienced nodule regrowth. Of these 39 patients, 17 (43.6%) underwent surgery and 14 (35.9%) underwent a second laser treatment. The rate of nodule regrowth was inversely related to the 12-month VRR, i.e., the lower the 12-month VRR, the higher the risk of regrowth (p < 0.001). The mean time for nodule regrowth was 33.5 ± 16.6 months. The 12-month VRR was directly related to time to regrowth, i.e., the lower the 12-month VRR, the shorter the time to regrowth (p < 0.001; R2 = 0.3516). Non-spongiform composition increased the risk of regrowth with an odds ratio of 4.3 (95% confidence interval [CI] 1.8-10.2; p < 0.001); 12-month VRR < 50.0% increased the risk of regrowth with an odds ratio of 11.7 (95% CI 4.2-32.2; p < 0.001). Conclusion: The VRR of thyroid nodules subjected to similar amounts of laser energy varies widely and depends on the nodule composition; non-spongiform nodules are reduced to a lesser extent and regrow more frequently than spongiform nodules. A 12-month VRR < 50.0% is a predictive risk factor for regrowth and correlates with the time to regrowth.

Effects of no-till direct seeding on irrigation water and cost reduction - A field case study (무경운 직파재배가 논 용수량 및 비용절감에 미치는 효과 - 현장 사례 연구)

  • Chung, Sang-Ok;Kim, Ji-Yong
    • Current Research on Agriculture and Life Sciences
    • /
    • v.18
    • /
    • pp.33-42
    • /
    • 2000
  • A field case study was performed to investigate the effect of shallow ponding in paddy field on irrigation water requirement of direct seeded rice. In addition, an economic analysis was made to see the effect of no-till direct seeded rice on cost reduction. A field study was performed at a 2.1ha paddy field in Kimjae city, Chonbuk province from 1991 to 1999. Various direct seeding methods such as dryland seeding, wetland seeding, and no-till wetland seeding were introduced. Then, cost reductions due to the direct seeding and no-till were calculated. In addition, to investigate the effect of shallow ponding on irrigation water requirement, field measurements such as irrigation water volume, drainage water volume, rainfall depth, and ponding depth, were made at a 40a plot within the same area in 1988 and 1990. The results of the shallow ponding study showed that the irrigation water depth, rainfall, and the drainage depth were 379mm, 458mm, and 448mm in 1988 growing season, and 274mm, 819mm, and 736mm in 1990, respectively. The shallow ponding irrigation method saved irrigation water by about 20% with higher yield compared with the traditional method. The economic analysis showed that won \640,000 per ha can be saved by direct seeding due to no nursery cost, and \1,220,000 per ha due to no-till and no nursery cost. The yields ranged 540 to 640 kg per 10a during the study period with an average of 590kg per 10a. If these cropping techniques with no-till direct seeding and shallow ponding depth for rice cropping prove to be advantageous with further study, they can be adopted for the most of the paddy fields in Korea.

  • PDF

The Activity of Proliferating Cell Nuclear Antigen(PCNA) of Uterine Myoma after Treatment with Gonadotropin Releasing Hormone(GnRH) Analogue (자궁근종 환자에서 Gonadotropin Releasing Hormone(GnRH) 유사체 투여 후 자궁근종 세포 증식에 관한 연구)

  • Lee, Byung-Seok;Lee, Bo-Yeon;Park, Ki-Hyun;Cho, Dong-Jae;Lee, Kook;Song, Chan-Ho;Kim, Ho-Keun
    • Clinical and Experimental Reproductive Medicine
    • /
    • v.19 no.2
    • /
    • pp.175-179
    • /
    • 1992
  • The factors involved in the initial neoplastic transformation and subsquent growth of uterine fibroid are poorly understood. The reduction in uterine fibroid volume associated with the chronic administration of the mechanisms mediating the decrease in fibroid volume in GnRH-a treated patients are poorly defined. The purpose of this study was to determine the proliferating cell nuclear antigen(PCNA) in fibroid from-women pretreated with GnRH analogue(GnRH-a) compared with controls. Tissue was obtained from 16 premenopausal women with uterine fibroid who received GnRH-a(D-Trp6-GnRH) intramusculary every 28 days for four injections. The mean proliferating index(PI) in patients with uterine fibroids was $2.25{\pm}0.9$, and in controls was $8.82{\pm}1.8$(P<0.001). The proliferating index was not corrleated with the reduction of fibroid volume. In this clinical study, although hypoestrogenism may be the main factor that reduce the volume of fibroid, other factors are also considered to be involved in that process. And the regrowth of uterine fibroid may be affected by increased production of PCNA after stopping GnRH-a.

  • PDF

A Study on Logistics Cost Management to Using Cost Volume Profit (CVP를 이용한 물류비 관리에 관한 연구)

  • Kim Jin-Sep;Kim Ong-Soo
    • The Journal of the Korea Contents Association
    • /
    • v.6 no.7
    • /
    • pp.22-30
    • /
    • 2006
  • The goal of the company and profit maximization can be achieved by creating revenue or reducing costs. What can be done by the effort of the firm itself is possible through cost-reduction rather than through revenue-creation. Under this economic situation, one of the best way for cost-reduction is to reduce cost of logistics. But logistics costs of a firm is continually increased because of the various customer-satisfaction, competition. This study considers that logistics cost management system be able to apply business practice through to used only a merit of CVP(Cost - Volume Profit) analysis method for effective decision making. To conclude, this study depicts that logistics cost management according to used a merit of CVP analysis method can provide information useful for making strategy of logistics. In short, It is reduce to more costs of logistics investment than are necessary. and, I will expect a man who charge logistics to improvement, adaptation, and application.

  • PDF

A retrospective computed tomography analysis of maxillary fractures and the clinical outcomes of their unreduced parts

  • Chung, Chan Min;Tak, Seung Wan;Lim, Hyoseob;Cho, Sang Hun;Lee, Jong Wook
    • Archives of Craniofacial Surgery
    • /
    • v.20 no.6
    • /
    • pp.370-375
    • /
    • 2019
  • Background: Some parts of a maxillary fracture-for example, the medial and posterior walls-may remain unreduced because they are unapproachable or hard to deal with. This study aimed to investigate the self-healing process of unreduced maxillary membranous parts of fractures through a longitudinal computed tomography (CT) analysis of cases of unilateral facial bone injuries involving the maxillary sinus walls. Methods: Thirty-two patients who had undergone unilateral facial bone reduction surgery involving the maxillary sinus walls without reduction of the medial and posterior walls were analyzed in this retrospective chart review. Preoperative, immediate postoperative, and 3-month postoperative CT scans were analyzed. The maxillary sinus volume was calculated and improvements in bone continuity and alignment were evaluated. Results: The volume of the traumatized maxillary sinuses increased after surgery, and expanded significantly by 3 months postoperatively (p< 0.05). The significant preoperative volume difference between the normal and traumatized sides (p= 0.024) resolved after surgery (p> 0.05), and this resolution was maintained at 3 months postoperatively (p > 0.05). The unreduced parts of the maxillary bone showed improved alignment and continuity (in 75.0% and 90.6% of cases, respectively), and improvements in bone alignment and bone continuity were found to be correlated using the Pearson chi-square test (p= 0.002). Conclusion: Maxillary wall remodeling through self-healing occurred concomitantly with an increase in sinus volume and simultaneous improvements in bone alignment and continuity. Midfacial surgeons should be aware of the natural course of unreduced fractured medial and posterior maxillary walls in complex maxillary fractures.

A Rapid Preconcentration Method Using Modified GP-MSE for Sensitive Determination of Trace Semivolatile Organic Pollutants in the Gas Phase of Ambient Air

  • He, Miao;Xu, Qingjuan;Yang, Cui;Piao, Xiangfan;Kannan, Narayanan;Li, Donghao
    • Bulletin of the Korean Chemical Society
    • /
    • v.35 no.10
    • /
    • pp.2995-3000
    • /
    • 2014
  • A sensitive concentration method utilising modified gas-purge microsyringe extraction (GP-MSE) was developed. Concentration (reduction in volume) to a microlitre volume was achieved. PAHs were utilised as semivolatile analytes to optimise the various parameters that affect the concentration efficiency. The injection rate and temperature were the key factors that affected the concentration efficiency. An efficient concentration (75.0-96.1%) of PAHs was obtained under the optimised conditions. The method exhibited good reproducibility (RSD values that ranged from 1.5 to 9.0%). The GP-MSE concentration method enhances the volume reduction (concentration factor), leading to a low method detection limit ($0.5-15ngL^{-1}$). Furthermore, this method offers the advantage of small-volume sampling, enabling even the detection of diurnal hourly changes in the concentration of PAHs in ambient air. Utilising this method in combination with GC-MS, the diurnal hourly flux of PAHs from the gas phase of ambient air was measured. Indeed, the proposed technique is a simple, fast, low-cost and environmentally friendly.