• Title/Summary/Keyword: Volume Efficiency

Search Result 2,126, Processing Time 0.031 seconds

Models of Wastewater Treatment by Rotating Discs (회전원판접촉법(回轉圓板接觸法)에 의한 폐수처리(廢水處理)의 모형(模型)에 관한 연구(研究))

  • Chung, Tai Hak;Park, Chung Hyun
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.2 no.2
    • /
    • pp.39-46
    • /
    • 1982
  • A model of substrate removal by rotating discs has been developed for a better understanding of the process, and the performance of the system has been evaluated under steady and unsteady state. The model was constructed based upon mass transfer of the substrate from the bulk solution to the biofilm and a simultaneous removal of the substrate by the biomass. The model is composed of a few sets of differential equations representing mass balance within the elements of a liquid film and a biofilm, and in the bulk solution. Substrate removal efficiency of the process is largely dependent on a diffusion coefficient of the substrate within the biofilm and a maximum rate of substrate removal of the biomass. The efficiency is affected to a greater extent when the substrate concentration is low and the maximum substrate removal rate is high. The efficiency increases proportionally with increasing film depth when the biofilm is shallow, however, the rate of increase gradually decreases with an increase of the film depth. As the film reaches a limiting depth, the efficiency remains constant. Unlike the steady state, the effluent quality is affected by the tank volume under dynamic state. Increasing tank volume decreases peak concentration of the effluent under peak loading. Additional tank volume provides a buffer capacitya.gainst a peak loading and the holding tank behaves like an equalization tank.

  • PDF

Optimization of Design Pressure Ratio of Positive Displacement Expander for Engine Waste Heat Recovery of Vehicle (자동차 엔진 폐열 회수 동력시스템에서 용적형 팽창기의 설계 팽창비 최적화)

  • Kim, Young Min;Shin, Dong Gil;Kim, Chang Gi;Woo, Se Jong;Choi, Byung Chul
    • Journal of Energy Engineering
    • /
    • v.21 no.4
    • /
    • pp.411-418
    • /
    • 2012
  • The effect of built-in volume ratio of expander on the performance of a two-loop Rankine cycle system for engine waste heat recovery of vehicle has been investigated. In the case of positive displacement expander in the various operating condition of the vehicle, it can operate in both under-expansion and over-expansion conditions. Therefore, the analysis of off-design performance for the expander is very important. Furthermore, the volume and weight of the expander as well as the efficiency must be considered in the optimization of the expander. This study shows that the built-in volume ratio of expander causing under-expansion at a target condition is more desirable considering the off-design performance and size of the expander, based on the simple modeling of off-design operation of the expander.

Treatment of Recycling Wastewater of Aquaculture Using DynaSand Filter( I ) (상향류식 연속역세여과를 이용한 양어장 순환수 재이용(I))

  • 박종호;김이오;황규덕;황금희;조규석;김동식
    • Journal of Aquaculture
    • /
    • v.15 no.2
    • /
    • pp.87-93
    • /
    • 2002
  • To improve the efficiency of biological filters used for treating recycled wastewater of aquaculture, the conventional and advanced DynaSand Filters were tested. Applying the fluid mechanics and physical chemistry theories to wastewater treatment plant, the advanced filter focuses on detection of wastewater characteristics and automatic operation of DynaSand Filter to improve backwashing, oxygen transport, turbidity removal and continuous head loss. The Filter removes COD, ammonia, and suspended solids (SS), the major pollutants in aquaculture wastewater. The total volume of the DynaSand Filter is 70 L, while the working volume is 35 L per cycle. The removal efficiency of the advanced DynaSand Filter is 71 % for SS (as against 55 % for the conventional filter), 84 % for ammonia, 85 % for T-P, and 88 % for SRP.

Evaluation of Water Cycle Improvement in LH Institute Using SWMM-LID Model (SWMM-LID 모델을 이용한 토지주택연구원의 물순환 개선효과 평가)

  • Jung, Jong-Suk;Jung, Kwang-Wook;Kang, Suman;Hyun, Kyong-Hak
    • Journal of Korean Society on Water Environment
    • /
    • v.34 no.3
    • /
    • pp.308-315
    • /
    • 2018
  • SWMM-LID was calibrated with flow monitoring data in LHI to evaluate runoff after LID application. The flow rate in the B basin was estimated to be 0.94 and 6.15 for O/S and $D_v$, respectively. In the A and C basins, the difference between the observed and simulated data was greater than in the B basin. As a result of runoff reduction efficiency by the application of LID facilities, the change of infiltration increased from 34.6 % to 45.8 % in the entire watershed, and the runoff decreased from 58.8 % to 46.3 %. In the runoff reduction of each LID facility, rain garden E showed the highest effect with 99.9 % and bioretention B showed the lowest effect with 27.5 %. In order to evaluate the efficiency of each LID facility, a comparison is made between the pore volume (V) of the LID and the catchment area (A). The runoff showed a runoff reduction effect of about 70 % above the 0.1 volume/area (V/A) value. As a result of examining the runoff reduction with LID facilities by the LID module of SWMM, a reasonable design is possible by reflecting the appropriate LID volume to drainage area.

Operational Variables and Performance of Hydrodynamic Separator Treating Rainfall Runoff from Bridge (수리동력학적 분리장치에 의한 교량에서의 비점원 오염물질 처리시 운전변수와 분리효율에 관한 연구)

  • Kim, Yeonseok;Yu, Jianghua;Kim, Youngchul
    • Journal of Korean Society on Water Environment
    • /
    • v.27 no.3
    • /
    • pp.342-348
    • /
    • 2011
  • A hydrodynamic separator using natural free energy provided by bridge was operated for the treatment of stormwater runoff. The separator was automatically controlled by using electronic valve which is connected with pressure meter. Normally the separator was opened during dry days, but it was closed after the capture of first flush. The results indicated that the average pressure and the flow rate were directly affected by the rainfall intensity. The pressure was more than 3 meters as the rainfall intensity was above 5 mm/hr. The percent volume of underflow decreased as the pressure and flow rate increased, but the percent volume of overflow showed an opposite behavior. The concentration of total suspended solids (TSS) in underflow increased as a function of increasing pressure while it decreased in overflow. The TSS separation efficiency was evaluated based on mass balance. It ranged from 30% to 90% with the pressure ranging from 2 to 10 meters, and it was proportional to pressure and flow rate. The analysis of water balance indicated that around 13% of total runoff was captured by the separator as a first flush, and this runoff was separated as underflow and overflow with the respective percent volume of 29% and 71%. The pollutants budget was also examined based on mass balance. The results showed that the percent of TSS, $COD_{cr}$, TN and TP in underflow were 73%, 59%, 7.6% and 49%, respectively.

Analysis of Test Operations Effect of Open-Closed Loops Complex Geothermal System Combined with Groundwater Well (지하수정호 결합 복합지열시스템의 시범운영 효과분석)

  • Song, Jae-Yong;Kim, Ki-Joon;Lee, Geun-Chun;Jeong, Gyo-Cheol
    • The Journal of Engineering Geology
    • /
    • v.28 no.3
    • /
    • pp.475-488
    • /
    • 2018
  • This study evaluates geothermal system efficiency in terms of input power and heat exchange volume on the heat-source and load sides, by applying a combined open-closed type loop system comprising a geothermal system and a groundwater well to a cultivation site. In addition, this study analyzes the effects of heating and cooling for a complex geothermal system, by evaluating the temperatures of an external site and a cultivation site during operation. During cooling operations the heat exchange volume on the heat source side, average 90.0kW/h for an open type system with an input of 235L/minute groundwater, and 40.1kW/h for a closed type system with an input of 85L/minute circulating water, for a total average heat exchange volume of 130.1kW/h. The actual heat exchange volume delivered on the load side averages 110.4kW/h. The average EER by analysis of the geothermal system's cooling efficiency is 5.63. During heating operation analysis, the heat exchange volume on the heat source side, average 60.4kW/h in an open type system with an input of 266L/minute groundwater, and 22.4kW/h in closed type system with an input of 86L/minute circulating water, for a total average heat exchange volume of 82.9kW/h. The actual heat exchange volume delivered on the load side averages 112.0kW/h in our analysis. The average COP determined by analysis of the geothermal system's heating efficiency is 3.92. Aa a result of the tradeoff between the outside temperature and the inside temperature of the production facility and comparing the facility design with a combined well and open-closed loops geothermal(CWG) system, we determine that the 30RT-volume CWG system temperature are lower by $3.4^{\circ}C$, $6.8^{\circ}C$, $10.1^{\circ}C$ and $13.4^{\circ}C$ for ouside temperature is of $20^{\circ}C$, $25^{\circ}C$, $30^{\circ}C$ and $35^{\circ}C$, respectively. Based on these results, a summer cooling effect of about $10^{\circ}C$ is expected relative to a facility without a CWG system as the outside temperature is generally ${\geq}30^{\circ}C$. Our results suggest that a complex geothermal system provides improvement under a variety of conditions even when heating conditions in winter are considered. Thus It is expected that the heating-cooling tradeoffs of complex geothermal system are improved by using water screen.

A Study on the Characteristic Analysis of Winding Method and Slot Structure for Single Phase Induction Motor (단상유도기의 권선법 및 슬롯 구조에 따른 특성 해석 연구)

  • Hwang, Yo-Han;Kim, Ki-Chan;Won, Sung-Hong;Jung, Dae-Sung;Lee, Ju
    • Proceedings of the KIEE Conference
    • /
    • 2006.04b
    • /
    • pp.203-205
    • /
    • 2006
  • This paper presents a study on the winding method and structure of core of single phase induction motor in order to design the high efficiency motor. In case of single phase induction motor, winding fill factor and the number of turns in each slot are not uniform in general. Moreover, these can be the critical parameters for high efficiency design in case the size of motor should be restricted within certain volume. Therefore, we should analyze the effects of these parameters related to efficiency parameter. The characteristic analysis was performed by using FEM.

  • PDF

A DEA analysis on Container Terminals in Northern Vietnam, 2005-2014

  • NGUYEN, Minh Duc;KIM, Sung-June
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2015.07a
    • /
    • pp.165-166
    • /
    • 2015
  • Sea-ports in Northern Vietnam have experienced a rapid growth of container throughput volume in recent years. To accompany with such development, huge investments also have been performed to enhance local ports capacity. It becomes a crucial task for the port authorities or the port stevedoring industry to improve the ports efficiency in order to customize national resources. In this paper, Data Envelopment Analysis (DEA) is employed to evaluate the relative efficiency of container terminals in Northern Vietnam by collecting data from terminals since 2005 up to now. The development progress of the given terminals will be presented before providing a relative comparison among those year by year. The DEA result is then analyzed and suggestions with regard to changes in local economic environment in near future are contributed.

  • PDF

Study on the Performance of the Cascade System Using Alternative Refrigerants (대체냉매를 사용한 이원냉동 시스템의 성능에 관한 연구)

  • 박종훈;조금남
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.13 no.7
    • /
    • pp.564-571
    • /
    • 2001
  • The present study investigated the effect of key parameters on the performance of a cascade system using R-22 and R-23 refrigerants. Experimental data for the cascade system have been compared with simulation results using thermodynamic analysis. The cascade system tested at the evaporating temperature of $-80^{\circ}C $ and the condensing temperature of$40^{\circ}C $. The key experimental parameters were the evaporating temperature of the HTC(-35, -30, -25, -20, $-15^{\circ}C $) and mass flux of the HTC(200, 250, 300kg/$m^2$s). As the evaporating temperature and the mass flux of the HTC were increased respectively, the COP and the refrigerating efficiency were increased and then decreased while the volume flow rate per unit refrigeration capacity showed the opposite trend. The maximum COP and refrigerating efficiency were obtained at the evaporating temperature of the HTC of $-25^{\circ}C $ and the mass flux of 250 kg/$m^2$s.

  • PDF

Design of an Aquifer Thermal Energy Storage System (I) : Isothermal Analysis (지하대수층을 이용한 축열시스템의 설계 (I) : 등온해석)

  • Song, Y.K.;Lee, K.S.;Lee, T.H.;Kim, Y.H.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.5 no.2
    • /
    • pp.102-110
    • /
    • 1993
  • An isothermal analysis was conducted to develop the design tool of an aquifer thermal energy storage system. Taejeon aquifer was chosen for the analysis, and the variation of FRE(Fluid Recovery Efficiency) with respect to the aquifer natural velocity and thermal load were investigated. The analysis results were compared with those of ATESSS(Aquifer Thermal Energy Storage System Simulator) and agreed within 2% of discrepancy. It is recommended, based on the result of this study, that the system may be suitable for a large volume of hot or chill thermal energy storage system, such as for district heating or cooling.

  • PDF