• Title/Summary/Keyword: Volume Data

Search Result 5,156, Processing Time 0.036 seconds

Evaluation of Dynamic Delivery Quality Assurance Process for Internal Target Volume Based RapidArc

  • Song, Ju-Young
    • Progress in Medical Physics
    • /
    • v.28 no.4
    • /
    • pp.181-189
    • /
    • 2017
  • The conventional delivery quality assurance (DQA) process for RapidArc (Varian Medical Systems, Palo Alto, USA), has the limitation that it measures and analyzes the dose in a phantom material and cannot analyze the dosimetric changes under the motional organ condition. In this study, a DQA method was designed to overcome the limitations of the conventional DQA process for internal target volume (ITV) based RapidArc. The dynamic DQA measurement device was designed with a moving phantom that can simulate variable target motions. The dose distribution in the real volume of the target and organ-at-risk (OAR)s were reconstructed using 3DVH with the ArcCHECK (SunNuclear, Melbourne, USA) measurement data under the dynamic condition. A total of 10 ITV-based RapidArc plans for liver-cancer patients were analyzed with the designed dynamic DQA process. The average pass rate of gamma evaluation was $81.55{\pm}9.48%$ when the DQA dose was measured in the respiratory moving condition of the patient. Appropriate method was applied to correct the effect of moving phantom structures in the dose calculation, and DVH data of the real volume of target and OARs were created with the recalculated dose by the 3DVH program. We confirmed the valid dose coverage of a real target volume in the ITV-based RapidArc. The variable difference of the DVH of the OARs showed that dose variation can occur differently according to the location, shape, size and motion range of the target. The DQA process devised in this study can effectively evaluate the DVH of the real volume of the target and OARs in a respiratory moving condition in addition to the simple verification of the accuracy of the treatment machine. This can be helpful to predict the prognosis of treatment by the accurate dose analysis in the real target and OARs.

Root canal volume change and transportation by Vortex Blue, ProTaper Next, and ProTaper Universal in curved root canals

  • Park, Hyun-Jin;Seo, Min-Seock;Moon, Young-Mi
    • Restorative Dentistry and Endodontics
    • /
    • v.43 no.1
    • /
    • pp.3.1-3.10
    • /
    • 2018
  • Objectives: The aim of this study was to compare root canal volume change and canal transportation by Vortex Blue (VB; Dentsply Tulsa Dental Specialties), ProTaper Next (PTN; Dentsply Maillefer), and ProTaper Universal (PTU; Dentsply Maillefer) nickel-titanium rotary files in curved root canals. Materials and Methods: Thirty canals with $20^{\circ}-45^{\circ}$ of curvature from extracted human molars were used. Root canal instrumentation was performed with VB, PTN, and PTU files up to #30.06, X3, and F3, respectively. Changes in root canal volume before and after the instrumentation, and the amount and direction of canal transportation at 1, 3, and 5 mm from the root apex were measured by using micro-computed tomography. Data of canal volume change were statistically analyzed using one-way analysis of variance and Tukey test, while data of amount and direction of transportation were analyzed using Kruskal-Wallis and Mann-Whitney U test. Results: There were no significant differences among 3 groups in terms of canal volume change (p > 0.05). For the amount of transportation, PTN showed significantly less transportation than PTU at 3 mm level (p = 0.005). VB files showed no significant difference in canal transportation at all 3 levels with either PTN or PTU files. Also, VB files showed unique inward transportation tendency in the apical area. Conclusions: Other than PTN produced less amount of transportation than PTU at 3 mm level, all 3 file systems showed similar level of canal volume change and transportation, and VB file system could prepare the curved canals without significant shaping errors.

Correlation analysis of central corneal thickness, anterior chamber volume, and anterior chamber depth of 20 to 24 Years old population in Korea (한국인 20세부터 24세까지의 중심 각막 두께, 앞방 부피, 앞방 깊이에 대한 상관관계 분석)

  • Sang Yeul Park;Douk Hoon Kim
    • Journal of Korean Clinical Health Science
    • /
    • v.12 no.1
    • /
    • pp.1654-1659
    • /
    • 2024
  • Purpose: The aim of this study was to determine Correlation analysis of central corneal thickness, anterior chamber volume, and anterior chamber depth in Koreans aged 20 to 24 years using the Pentacam tool. Methods: The subjects of this study were 53 Korean adults with healthy eyes. The central corneal thickness(CCT), anterior chamber volume(ACV), and anterior chamber depth(ACD) was measured with Pentacam device. Data was analyzed by means of the Pearson's correlation cofficient. P-values<0.001 were considered statistically significant. Results: Mean age of subjects was 22.0±2.01 years. The mean +/- central corneal thickness of the right eye and left eye were 546.66±32.221mmg and 545.70±32.759mm, respectively. Also The mean central cornea thickness was 546.19 um in the whole sample. The mean anterior chamber volume the right eye and left eye was 181.66±33.738 mm3 and 180.12±30.84 mm3, respectively. The mean anterior chamber depth was 3.158±0.257 mm and 3.122±0.233 mm in right eye and left eye, respectively. There was a statistically significant difference between anterior camber volume and anterior chamber depth(p<0.001, Pearson's correlation). However there was no statistically significant difference between central cornea thickness and anterior chamber volume. Also there was no statistically significant difference between central cornea thickness and anterior chamber depth. Conclusion: The results of this study could be used as a clinical reference data for diagnosis and treatment of cornea in Korean adolescents.

Medical data visualization using Unity3D game engine (Unity3D 게임 엔진을 이용한 의료 데이터 가시화)

  • Ha, Taejun;Kye, Heewon
    • Journal of the Korea Computer Graphics Society
    • /
    • v.23 no.3
    • /
    • pp.87-94
    • /
    • 2017
  • Due to improvements in the capabilities of commercial game engines, there are increasing instances of applying game engines to scientific visualization applications. This study describes a case of creating a virtual reality application that visualizes medical volume data based on the Unity3D game engine. When using a game engine, there is an advantage that various functions required for an application are basically provided, such as depth sorting of translucent objects or virtual reality hardware support. On the other hand, there is a restriction that the structure of the application program should be modified to suit the characteristics of the game engine. This paper describes a method for visualizing medical volume data using the structure of a game engine. As a result, we were able to create a virtual reality scene that consisted of surface data and medical volume data fragments together. And we confirmed the possibility of game engine as a future medical simulation production tool.

Stereoscopic Imaging and Interpretation of the three Dimensional Seismic Data by Numerical Projection (뉴메리컬 프로젝션에 의한 3차원 탄성파 데이터의 영상화 및 해석)

  • 정성종;김태균
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.13 no.6
    • /
    • pp.490-500
    • /
    • 1988
  • In recent years the acquisition, processing and interpretation of three dimensional seisimic data, for the purpose of locating gas and reservoirs, have become practical. This paper exlores one way in which the volume data can be searched and visualized, which may aid the interpreter. The illusion of looking at a three dimensional volume can be obrained by fusing a stereoscopic pair of pictures. Each picture can be made by projecting each data point of the volume into a plane from a point where the eye is placed. The data valuse along any projection line can be summed to form the picture, or only a segment along the line can be selected. By selective projection, the volume can be searched and obscuring layers removed. The stereoscopic pictures show the physical models in there ture spatial positions. Projection of the envelope function of the seismic traces is shown to give improved depth perception compared with projection of the position amplitudes.

  • PDF

Analytic Generation of Reach Volume Based on Range of Two Degrees of Freedom Motion (2자유도 동작범위를 고려한 reach volume의 해석적 생성)

  • Kee, Do-Hyung
    • Journal of Korean Institute of Industrial Engineers
    • /
    • v.23 no.1
    • /
    • pp.147-162
    • /
    • 1997
  • When designing workplaces or arranging controls on panel, devices and controls should be placed within the reach of operator's arm or foot to guarantee effective performances. Most of the existing research on the reach volume were based on measurements of a few subject's arm reach, and limited to Caucasian and Chinese populations. Furthermore, reach volume considering foot or trunk motion have not been investigated. Range of human joint motion and that of two degrees of freedom motion are needed to generate reach volume analytically using the sweeping algorithm. However, range of two degrees of freedom motion has not been measured up to now. Therefore, range of two degrees of freedom motion was measured in this research, where 47 college students were participated voluntarily as subjects. The results showed that the motion of one joint can be limited by the motion of another motion, that is to say, the shoulder flexion was decreased significantly when the shoulder was adducted or abducted. Second, new approximate algorithms generating reach volumes were suggested, in which range of two degrees of freedom motion was used as input data. Depending upon the body segment included such as trunk, arm and leg, three types of reach volume were provided, in which the human body was modeled as a multilink system based on the robot kinematics and the sweeping method was employed. Reach volume generated analytically in this study showed statistically reasonable results when compared with that obtained from direct measurement.

  • PDF

Robust Ultrasound Multigate Blood Volume Flow Estimation

  • Zhang, Yi;Li, Jinkai;Liu, Xin;Liu, Dong Chyuan
    • Journal of Information Processing Systems
    • /
    • v.15 no.4
    • /
    • pp.820-832
    • /
    • 2019
  • Estimation of accurate blood volume flow in ultrasound Doppler blood flow spectrograms is extremely important for clinical diagnostic purposes. Blood volume flow measurements require the assessment of both the velocity distribution and the cross-sectional area of the vessel. Unfortunately, the existing volume flow estimation algorithms by ultrasound lack the velocity space distribution information in cross-sections of a vessel and have the problems of low accuracy and poor stability. In this paper, a new robust ultrasound volume flow estimation method based on multigate (RMG) is proposed and the multigate technology provides detail information on the local velocity distribution. In this method, an accurate double iterative flow velocity estimation algorithm (DIV) is used to estimate the mean velocity and it has been tested on in vivo data from carotid. The results from experiments indicate a mean standard deviation of less than 6% in flow velocities when estimated for a range of SNR levels. The RMG method is validated in a custom-designed experimental setup, Doppler phantom and imitation blood flow control system. In vitro experimental results show that the mean error of the RMG algorithm is 4.81%. Low errors in blood volume flow estimation make the prospect of using the RMG algorithm for real-time blood volume flow estimation possible.

Volumetric NURBS Representation of Multidimensional and Heterogeneous Objects: Modeling and Applications (VNURBS기반의 다차원 불균질 볼륨 객체의 표현: 모델링 및 응용)

  • Park S. K.
    • Korean Journal of Computational Design and Engineering
    • /
    • v.10 no.5
    • /
    • pp.314-327
    • /
    • 2005
  • This paper describes the volumetric data modeling and analysis methods that employ volumetric NURBS or VNURBS that represents heterogeneous objects or fields in multidimensional space. For volumetric data modeling, we formulate the construction algorithms involving the scattered data approximation and the curvilinear grid data interpolation. And then the computational algorithms are presented for the geometric and mathematical analysis of the volume data set with the VNURBS model. Finally, we apply the modeling and analysis methods to various field applications including grid generation, flow visualization, implicit surface modeling, and image morphing. Those application examples verify the usefulness and extensibility of our VNUBRS representation in the context of volume modeling and analysis.

Comparison Analysis of Donor Liver Volumes Estimated with 3D Magnetic Resonance and 3D Computed Tomography Image Data

  • Kim, Myeong-Seong;Park, Kyeong-Seok;Cho, Jae-Hwan
    • Journal of Magnetics
    • /
    • v.19 no.3
    • /
    • pp.261-265
    • /
    • 2014
  • Three-dimensional computed tomography is an effective tool to estimate the liver volume of living donors for the live liver transplantation. When additional operation is required, magnetic resonance imaging is conducted to determine the safety of the donor. This study compared the accuracy of magnetic resonance imaging and computed tomography in estimating 3D liver volume of 23 male and 7 female donors who underwent both magnetic resonance imaging and computed tomography tests before the transplantation. The analysis was conducted to see whether the liver's estimated total volumes and the left lobe volumes obtained from 3D-magnetic resonance imaging and 3D-computed tomography were identical. Volumes of the right lobe estimated with 3D-magnetic resonance imaging and 3D-computed tomography were compared with the actual volume of the right lobe harvested in the operating room because the volume of the right lobe is an important determinant in the safety of the donor. The total volume of the liver estimated from 3D-magnetic resonance imaging and 3D-computed tomography differed (1238.1904 units and 1402.364 units respectively). The left lobe volume of the liver estimated with 3D-magnetic resonance imaging and 3D-computed tomography also differed (450.530 units and 554.490 units, respectively). The right lobe volume of the liver estimated with 3D-magnetic resonance imaging and 3D-computed tomography were 787.660 units and 847.545 units, respectively, while the actual average right lobe volume of the harvested liver was 678.636 units. 3D-computed tomography has been widely used to estimate the right lobe volume of the donors' liver. However, 3D-magnetic resonance imaging was also very effective in estimating the volume of the liver. Thus, 3D-magnetic resonance imaging is also expected to become an important tool in determining the safety of the donors before transplantation.

Estimation of Volume and Surface Area for Reconstruction of Tongue (혀의 재건을 위한 부피 및 표면적의 측정)

  • Park, Ha-Na-Ro;Kim, Hee-Jin;Jeong, Woo-Jin;Ahn, Soon-Hyun
    • Korean Journal of Head & Neck Oncology
    • /
    • v.27 no.1
    • /
    • pp.27-31
    • /
    • 2011
  • Purpose : Anterolateral thigh and radial forearm flap is the most important fasciocutaneous flap widely used for reconstruction of tongue. One important purpose of flap is replacing the volume of tongue but still there is no data about the surface area and volume to be reconstructed after glossectomy. In this paper, surface area and volume is estimated from the 3-dimensionally reconstructed MRI images to see which flap is more ideal and to give the reference value for reconstruction. Materials and Methods : With coronal MRI image, tongue including only the intrinsic muscle is delineated in every section and reconstructed 3-dimensionally and calculated the volume and surface area to be reconstructed according to the degree of glossectomy. This volume and surface area was compared with the volume of anterolateral thigh and radial forearm flap. Results : The volume and surface area to be reconstructed in hemiglossectomy was $39.0{\pm}4.0cm^3$ and $31.8{\pm}2.7cm^2$ respectively. The average thickness of anterolateral thigh flap is $9.4{\pm}2.8mm$ and that of radial forearm is $3.8{\pm}1.0mm$. Comparing the curve of tongue surface area and volume with the volume of flap, the anterolateral thigh flap has more ideal volume to replace the defect. Conclusions : The surface area and volume requested for reconstruction could be suggested and the anterolateral thigh flap has more ideal volume for reconstruction of glossectomy defect.