• Title/Summary/Keyword: Volume Curve

Search Result 658, Processing Time 0.031 seconds

A study on floating and sinking pulse by classification of pulse pattern through analysis of P-H volume-curve at 5 applied pressure levels (5단계 가압에 대한 맥파 변화 분석에 의한 맥 패턴 분류와 부침맥(浮沈脈) 연구)

  • Kown, Sun-Min;Kang, Hee-Jung;Yim, Yun-Kyoung;Lee, Yong-Heum
    • Korean Journal of Acupuncture
    • /
    • v.27 no.1
    • /
    • pp.13-22
    • /
    • 2010
  • Objectives: The information on the depth where pulse wave appears is as important as pulse waveform. The aim of this study was to classify pulse pattern using pressure-height(P-H) volume-curve by 5 applied pressure levels to find out the information on the depth of pulse and interpret the floating & sinking pulse in oriental medical pulse diagnosis. Methods: We used 3 dimensional pulse imaging analyser (DMP-3000, DAEYOMEDI Co., Korea), which measures radial pulse waveforms noninvasively by way of tonometric method at 5 applied pressure levels, and shows P-H volume-curves by applied pressure. 448 subjects were enrolled, pulse waveforms were measured and the P-H volume-curves were gained on the three locations of Chon, Kwan, and Cheok. Results: Gained P-H volume curves were classified into 3 types ; increase type, decrease type, and increase-decrease type. Increase-decrease type appeared more often on Chon and Kwan, while increase type appeared more often on Cheok. In a few cases, decrease-type appeared on Chon and Kawn, however it never appeared on Cheok. Conclusions: Through the classification of pulse by P-H volume-curve, we gained the information on the depth of pulse. We speculate the decrease type as floating pulse, the increase-decrease type as middle pulse, and the increase type as sinking pulse in oriental medical pulse diagnosis. After more researches on P-H volume-curve by applied pressure, the P-H volume-curve may be used as an important factor for pulse diagnosis.

Regional Stem Curve and Volume Function Model of Pinus densiflora in Kangwon-Province (강원도 지방 소나무의 지역(地域) 간곡선(幹曲線) 및 재적식(材積式) 모델)

  • Kim, Joon Soon;Lee, Woo Kyun;Byun, Woo Hyuk
    • Journal of Korean Society of Forest Science
    • /
    • v.83 no.4
    • /
    • pp.521-530
    • /
    • 1994
  • Voume functions, which are usually expressed by the function of dbh and height, are estimated commonly through the regression analysis with the highest statistical accuracy considered. In Korea, general volume functions for each tree species were prepared by means of the regression analysis with the exponential function ($V=aD^bH^c$) having the dbh(D) and height(H) as independent variables. In this study, regional stem curve functions for the Pinus densiflora in Kangwon-province were derived and a regional volume function model, in which the stem volume can be directly estimated through the rotational integral of the regional stem curve functions, was prepared. The regional volume estimated by the prepared model was more accurate than the volume by the general volume table for the Pinus densiflora in Kangwon-province. Additionary, the form of stem curves derived by the regional stem curve functions showed difference from each other. The stem in Youngwol and Wonju taper down more fast in upper part than that in other regions. These various stem forms also led to the regional difference in volume estimates.

  • PDF

Correlations between Body Indices and Flow-Volume Curve Parameters (신체지표와 유량-기량곡선 지표간의 상관성)

  • Jin, Bok-Hee
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.41 no.3
    • /
    • pp.135-139
    • /
    • 2009
  • Pulmonary function test has been know to be greatly affected by body indices, such as sex, age, height, body weight, body surface area (BSA) and body mass index (BMI), so hat this study was focused to see the relationship between body index and flow-volume curves. Subjects were 156 (male 90, female 66) and they were examined for pulmonary function test in terms of body index and correlation/multiple regression analysis of flow-volume curves at Presbyterian Medical Center from March to August, 2009. The followings results after analyzing the correlation between body index and flow-volume curves. Although flow-volume curve FEF25-75% showed close correlation with age, body weight, and body surface area, but not with body mass index. In addition, multiple regression analysis was performed to see how each body index affects flow-volume curve FEF25-75%, and FEF25-75% dispersion was explained as 74.5% with age only, 94.2% with age and height, and 96% with age, height, and sex. Therefore, sex, age and height that are mainly used for predictive formular of pulmonary function test and nomogram were important factors for pulmonary function test itself, and further study must be done for other body index.

  • PDF

Landslide Analysis Using the Wetting-Drying Process-Based Soil-Water Characteristic Curve and Field Monitoring Data (현장 함수비 모니터링과 습윤-건조 함수특성곡선을 이용한 산사태 취약성 분석)

  • Lee, Seong-Cheol;Hong, Moon-Hyun;Jeong, Sang-Seom
    • Journal of the Korean Geotechnical Society
    • /
    • v.39 no.5
    • /
    • pp.13-26
    • /
    • 2023
  • This study examined the soil-water characteristic curve (SWCC), considering the volume change, using wetting curves on the field monitoring data of a wireless sensor network. Special attention was given to evaluating the landslide vulnerability by deriving a matric suction suitable for the actual site during the wetting process. Laboratory drying SWCC and shrinkage laboratory tests were used to perform the combined analysis of landslide and debris flow. The results showed that the safety factor of the wetting curve, considering the volume change of soil, was lower than that of the drying curve. As a result of numerical analyses of the debris flow simulation, more debris flow occurred in the wetting curve than in the drying curve. It was also found that the landslide analysis with the drying curve tends to overestimate the actual safety factor with the in situ wetting curve. Finally, it is confirmed that calculating the matric suction through SWCC considering the volume change is more appropriate and reasonable for the field landslide analysis.

Adaptive B-spline volume representation of measured BRDF data for photorealistic rendering

  • Park, Hyungjun;Lee, Joo-Haeng
    • Journal of Computational Design and Engineering
    • /
    • v.2 no.1
    • /
    • pp.1-15
    • /
    • 2015
  • Measured bidirectional reflectance distribution function (BRDF) data have been used to represent complex interaction between lights and surface materials for photorealistic rendering. However, their massive size makes it hard to adopt them in practical rendering applications. In this paper, we propose an adaptive method for B-spline volume representation of measured BRDF data. It basically performs approximate B-spline volume lofting, which decomposes the problem into three sub-problems of multiple B-spline curve fitting along u-, v-, and w-parametric directions. Especially, it makes the efficient use of knots in the multiple B-spline curve fitting and thereby accomplishes adaptive knot placement along each parametric direction of a resulting B-spline volume. The proposed method is quite useful to realize efficient data reduction while smoothing out the noises and keeping the overall features of BRDF data well. By applying the B-spline volume models of real materials for rendering, we show that the B-spline volume models are effective in preserving the features of material appearance and are suitable for representing BRDF data.

Analysis of Applicability in the Public Transportation System considering the Cost-volume Supply Curve of New Transit System Bi-Modal Tram (녹색 신교통 시스템 바이모달트램의 비용-수요 공급곡선을 고려한 도시 대중교통체계 적용 특성 분석)

  • Kim, Hong-Seok;Kim, Ryang-Gyun;Ham, Jae-Hyun;Jeon, Jae-Cheong;Yoon, Hee-Taek
    • Proceedings of the KSR Conference
    • /
    • 2010.06a
    • /
    • pp.2303-2308
    • /
    • 2010
  • We studied the cost-volume supply characteristic of public transportation systems focused on Bi-modal Tram in the main cities to analyze the applicability and status for the new transit system Bi-modal Tram as public transportation system. The operation cost considering the characteristic of vehicle, facilities, operation and average cost for respective public transportation system and the time cost considering the travel and transfer time are defined to the social cost, and the cost-volume supply curve is based on this social cost. The cost-volume supply characteristic between public transportation modes in the city is determined on the basis of cost-volume supply curve. Through the comparison between cost-volume supply characteristic of main transportation systems, it is analyzed about the relation between public transportation systems in the city and the characteristic for proper service provision. The application of Bi-modal Tram in the city is concluded that it is effective to reduce the social cost on the existing public transportation system.

  • PDF

Development of 3D Mapping Algorithm with Non Linear Curve Fitting Method in Dynamic Contrast Enhanced MRI

  • Yoon Seong-Ik;Jahng Geon-Ho;Khang Hyun-Soo;Kim Young-Joo;Choe Bo-Young
    • Journal of the Korean Magnetic Resonance Society
    • /
    • v.9 no.2
    • /
    • pp.93-102
    • /
    • 2005
  • Purpose: To develop an advanced non-linear curve fitting (NLCF) algorithm for dynamic susceptibility contrast study of brain. Materials and Methods: The first pass effects give rise to spuriously high estimates of $K^{trans}$ in voxels with large vascular components. An explicit threshold value has been used to reject voxels. Results: By using this non-linear curve fitting algorithm, the blood perfusion and the volume estimation were accurately evaluated in T2*-weighted dynamic contrast enhanced (DCE)-MR images. From the recalculated each parameters, perfusion weighted image were outlined by using modified non-linear curve fitting algorithm. This results were improved estimation of T2*-weighted dynamic series. Conclusion: The present study demonstrated an improvement of an estimation of kinetic parameters from dynamic contrast-enhanced (DCE) T2*-weighted magnetic resonance imaging data, using contrast agents. The advanced kinetic models include the relation of volume transfer constant $K^{trans}\;(min^{-1})$ and the volume of extravascular extracellular space (EES) per unit volume of tissue $\nu_e$.

  • PDF

The calculation of stress-strain behavior of Ti-10V-2Fe-3Al alloys (Ti-10V-2Fe-3Al 합금의 응력-변형거동 계산)

  • 오택열
    • Journal of the korean Society of Automotive Engineers
    • /
    • v.11 no.6
    • /
    • pp.38-47
    • /
    • 1989
  • The Finite Element Method has been employed to calculate the effect of particle size, matrix, and volume fractions on the stress-strain relations of .alpha.-.betha. titanium alloys. It was found that for a given volume fraction, the calculated stress-strain curve was higher for a finer particle size than for a coarse particle size within the range of the strains considered, and this behavior was seen for all the different volume fraction alloys considered. The calculated stress-strain curves for three vol. pct .alpha. alloys were compared with their corresponding experimental curve, and in general, good agreement was found.

  • PDF

Comparison of Regression Models for Estimating Ventilation Rate of Mechanically Ventilated Swine Farm (강제환기식 돈사의 환기량 추정을 위한 회귀모델의 비교)

  • Jo, Gwanggon;Ha, Taehwan;Yoon, Sanghoo;Jang, Yuna;Jung, Minwoong
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.62 no.1
    • /
    • pp.61-70
    • /
    • 2020
  • To estimate the ventilation volume of mechanically ventilated swine farms, various regression models were applied, and errors were compared to select the regression model that can best simulate actual data. Linear regression, linear spline, polynomial regression (degrees 2 and 3), logistic curve, generalized additive model (GAM), and gompertz curve were compared. Overfitting models were excluded even when the error rate was small. The evaluation criteria were root mean square error (RMSE) and mean absolute percentage error (MAPE). The evaluation results indicated that degree 3 exhibited the lowest error rate; however, an overestimation contradiction was observed in a certain section. The logistic curve was the most stable and superior to all the models. In the estimation of ventilation volume by all of the models, the estimated ventilation volume of the logistic curve was the smallest except for the model with a large error rate and the overestimated model.

Accuracy of maximal expiratory flow-volume curve curvilinearity and fractional exhaled nitric oxide for detection of children with atopic asthma

  • Park, Sang Hoo;Im, Min Ji;Eom, Sang-Yong;Hahn, Youn-Soo
    • Clinical and Experimental Pediatrics
    • /
    • v.60 no.9
    • /
    • pp.290-295
    • /
    • 2017
  • Purpose: Airway pathology in children with atopic asthma can be reflected by the concave shape of the maximal expiratory flow-volume (MEFV) curve and high fractional exhaled nitric oxide (FeNO) values. We evaluated the capacity of the curvilinearity of the MEFV curve, FeNO, and their combination to distinguish subjects with atopic asthma from healthy individuals. Methods: FeNO and angle ${\beta}$, which characterizes the general configuration of the MEFV curve, were determined in 119 steroid-naïve individuals with atopic asthma aged 8 to 16 years, and in 92 age-matched healthy controls. Receiver operating characteristic (ROC) curve analyses were performed to determine the cutoff points of FeNO and angle ${\beta}$ that provided the best combination of sensitivity and specificity for asthma detection. Results: Asthmatic patients had a significantly smaller angle ${\beta}$ and higher FeNO compared with healthy controls (both, P<0.001). For asthma detection, the best cutoff values of angle ${\beta}$ and FeNO were observed at $189.3^{\circ}$ and 22 parts per billion, respectively. The area under the ROC curve for the combination of angle ${\beta}$ and FeNO improved to 0.91 (95% confidence interval [CI], 0.87-0.95) from 0.80 (95% CI, 0.75-0.86; P<0.001) for angle ${\beta}$ alone and 0.86 (95% CI, 0.82-0.91; P=0.002) for FeNO alone. In addition, the combination enhanced sensitivity with no significant decrease in specificity. Conclusion: These data suggest that the combined use of the curvilinearity of the MEFV curve and FeNO is a useful tool to differentiate between children with and without atopic asthma.