• Title/Summary/Keyword: Voltammogram

Search Result 177, Processing Time 0.029 seconds

Singular Point of Voltammetric Impedance Data and its Application in Analyzing Voltammetry Data

  • Chang, Byoung-Yong
    • Journal of Electrochemical Science and Technology
    • /
    • v.9 no.2
    • /
    • pp.149-156
    • /
    • 2018
  • In this technical note, I report the analysis of electrochemical impedance data measured with potential sweeping. Even though the instruments for voltammetric impedance measurements have been developed for decades using different approaches, their applications are limited due to the lack of well-established protocols to easily analyze voltammetry data. To fill this gap, the singular point of the specific potential is considered that is only determined by the standard/formal potential and the transfer coefficient and is independent of the kinetics and experimental parameters (including revertability) of faradaic reactions. Taking the advantage of its inertness, I suggest an approach employing the singular point as a reference to obtain general electrochemical information. As all the concepts and methods are verified with numerical simulations, this technique is expected to be applied for complex reactions involving electrochemical and chemical reaction mechanisms.

Toxicological Investigation of Radioactive Uranium in Seawater

  • Ly, Suw-Young;Bae, Jeong-Mi;Kim, Jin
    • Toxicological Research
    • /
    • v.28 no.1
    • /
    • pp.67-71
    • /
    • 2012
  • Trace uranium detection measurement was performed using DNA immobilized on a graphite pencil electrode(DGE). The developed probe was connected to the portable handheld voltammetric systems used for seawater analysis. The sensitive voltammogram was obtained within only 30 s accumulation time, and the anodic stripping working range was attained at 100~800 ${\mu}g/l$ U and 10~50 ${\mu}g/l$. The statistic relative standard deviation of 30.0 mg/l with the $15^{th}$ stripping was 0.2115. Here, toxicological and analytical application was performed in the seawater survey in a contaminated power plant controlling water. The results were found to be applicable for real-time toxicological assay for trace control.

Electrochemical Approach in Plasma Display Panel Glass Melts doped with Sulfate and Sulfide II. Square Wave Voltammetry

  • Kim, Ki-Dong
    • Journal of the Korean Ceramic Society
    • /
    • v.45 no.7
    • /
    • pp.375-379
    • /
    • 2008
  • Redox behavior was observed in alkali alkaline earth silicate PDP (Plasma Display Panel) glass melts doped with sulfate and sulfide by square wave voltammetry (SWV). According to voltammograms produced at a temperature range of 1100 to $1400^{\circ}C$ and frequency range of 5 to 1000 Hz, both melts showed the same behavior in which there is one reduction peak at low frequency but another peak at an increase of frequency. Based on the frequency dependence of the peak current, self diffusivity of $S^{4+}$ was determined. Based on the temperature dependence of the peak potential, standard enthalpy (${\Delta}H^0$) and standard entropy (${\Delta}S^0$) for the reduction of $S^{4+}$ to $S^0$ were calculated.

Electrochemical Properties of Viologen Self-Assembly Monolayer Using QCM (수정진동자를 이용한 Viologen Self-Assembly 단분자막의 전기화학적 특성)

  • 옥진영;신훈규;박재철;장정수;권영수
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.16 no.6
    • /
    • pp.496-500
    • /
    • 2003
  • Molecular self-assembled of surfactant viologen are of recent interest because they can from functional electrodes as well as micellar assemblies, which can be profitably utilized for display devices, photoelectrochemical studies and electrocatalysis as electron acceptor or electron mediator. Fromherz et al studied the self-assembly of thiol and disulfide derivatives of viologens bearing long n-alkyl chains on Au electrode surface[1]. The electrochemical behavior of self-assembled viologen monolayer has been investigated with QCM, which has been known as nano-gram order mass detector. The self-assembly process of viologen was monitored using resonant frequency(ΔF) and resonant resistance(R). The redox process of viologen was observed with resonant frequency(ΔF).

Electrochemical Rectification at Electrode Chemically Modified with Redox Active Agents at Monolayer (산화환원 화학 종이 단 분자 층으로 화학 흡착된 전극에서의 전기화학적 정류)

  • Lee, Chi-Woo J.;Yoon, Jung-Hyun;Oh, Mi-Kyung
    • Journal of the Korean Electrochemical Society
    • /
    • v.10 no.1
    • /
    • pp.43-47
    • /
    • 2007
  • Electrochemical rectification at electrode chemically modified with redox active agents isolated at monolayer level was considered. Formulation of the rising part of linear sweep voltammogram at steady and rotating disc electrode was introduced.

The Preparation Characteristic of Polyphenylenediamine -Dimercaptan Composite film (Polyphenylenediamine-Dimercaptan 복합 필름의 제막특성)

  • 박수길;나재진;이홍기;임기조;김상욱;이주성
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1996.11a
    • /
    • pp.105-108
    • /
    • 1996
  • The positive active material for polymer film battery was prepared by using Polyphenylenediamine(PPD) synthesized in our lab. and 2.5-dimercapto-1, 3, 4-thiadiazole(DMcT) in various mixture ratio. The transference measurement of surface morphology and thermal stability of prepared composite film was carried out by using SEM and TGA, respectively. Electrocyhemical property and electrical conductivity of composite film were also measured by using cyclic voltammetry and four-probe method in dry box, respectively. The thermal stability of prepared composite film is more than 20$0^{\circ}C$. The electrical conductivity of composite film increased and showed the highest value(about 3 S/cm)when doped at 0.4% LiClO$_4$solution. And we could confirm that DMcT effect on reactiviation of PPD through cyclic voltammogram.

  • PDF

Development of New DNA Chip and Genome Detection Using an Indicator-free Target DNA (비수식화 DNA를 이용한 유전자 검출 및 새로운 DNA칩의 개발)

  • Park, Yong-Sung;Park, Dae-Hee;Kwon, Young-Soo;Tomoji Kawai
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.52 no.8
    • /
    • pp.365-370
    • /
    • 2003
  • This research aims to develop an indicator-free DNA chip using micro-fabrication technology. At first, we fabricated a DNA microarray by lithography technology. Several probe DNAs consisting of thiol group at their 5-end were immobilized on the gold electrodes. Then indicator-free target DNA was hybridized by an electrical force and measured electrochemically in potassium ferricyanide solution. Redox peak of cyclic-voltammogram showed a difference between target DNA and mismatched DNA in an anodic peak current. Therefore, it is able to detect various genes electrochemically after immobilization of various probe DNAs and hybridization of indicator-free DNA on the electrodes simultaneously It suggested that this DNA chip could recognize the sequence specific genes.

Development of Next Generation Biochip Using Indicator-free DNA (비수식화 DNA를 이용한 차세대형 바이오칩의 개발)

  • Choi, Yong-Sung;Moon, Jong-Dae;Lee, Kyung-Sup
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2006.05a
    • /
    • pp.71-73
    • /
    • 2006
  • This research aims to develop a multiple channel electrochemical DNA chip using micro- fabrication technology. At first, we fabricated a high integrated type DNA chip array by lithography technology. Several probe DNAs consisting of thiol group at their 5-end were immobilized on the gold electrodes. Then target DNAs were hybridized by an electrical force. Redox peak of cyclic-voltammogram showed a difference between target DNA and mismatched DNA in the anodic peak current. Therefore. it is able to detect a various genes electrochemically after immobilization of a various probe DNA and hybridization of label-free DNA on the electrodes simultaneously. It suggested that this DNA chip could recognize the sequence specific genes.

  • PDF

Electrochemical Properties of Electric Double Layer Capacitor Using Carbon Electrodes (Carbon 전극을 이용한 전기 이중층 캐패시터의 전기화학적 특성)

  • Bang, J.G.;Song, J.G.;Choi, S.A.;Park, G.C.;Gu, H.B.
    • Proceedings of the KIEE Conference
    • /
    • 1997.07d
    • /
    • pp.1609-1611
    • /
    • 1997
  • We fabricated five type of electric double layer capacitor(EDLC) with extremely stable activated carbon as a positive and negative electrodes. The electrodes consisted of activated carbon and several different conductor layers on aluminium foil. Cyclic voltammogram of activated carbon electrodes at scan rate 5mV/sec was reversable redox reaction. The discharge capacity of activated carbon-KS 6 composite electrode was higher than that of activated carbon electrode without KS 6.

  • PDF

Preparation of 3,4-Ethylenedioxythiophene (EDOT) and N-4-butylphenyl-N,N-diphenylamine (BTPA) Copolymer Having Hole Transport Ability

  • Sim, Jae-Ho;Sato, Hisaya
    • Macromolecular Research
    • /
    • v.17 no.9
    • /
    • pp.714-717
    • /
    • 2009
  • Hole transport copolymers consisting of 3,4-ethylenedioxythiophene (EDOT) and N-4-butylphenyl-N,N-diphenylamine (BTPA) were synthesized by oxidative coupling reaction using $FeCl_3$ as an oxidant. These copolymers showed good solubility and their thin films showed sufficient morphological stability. The copolymers showed an absorption maximum around 320 nm. Copolymers had an oxidation peak at approximately $1.03{\sim}1.14V$ versus the Ag/AgCl electrode. The hole mobility increased with increasing portion of the EDOT unit. The hole mobility of the copolymer containing 57% of the EDOT unit showed the highest mobility of $3{\times}10^{-5}cm^2/V{\cdot}s$.