• Title/Summary/Keyword: Voltage-controlled Oscillator

Search Result 371, Processing Time 0.023 seconds

Technical Evaluation of Engineering Model of Ultra-Small Transmitter Mounted on Sweetpotato Hornworm

  • Nakajima, Isao;Muraki, Yoshiya;Mitsuhashi, Kokuryo;Juzoji, Hiroshi;Yagi, Yukako
    • Journal of Multimedia Information System
    • /
    • v.9 no.2
    • /
    • pp.145-154
    • /
    • 2022
  • The authors are making a prototype flexible board of a radio-frequency transmitter for measuring an electromyogram (EMG) of a flying moth and plan to apply for an experimental station license from the Ministry of Internal Affairs and Communications of Japan in the summer of 2022. The goal is to create a continuous low-dose exposure standard that incorporates scientific and physiological functional assessments to replace the current standard based on lethal dose 50. This paper describes the technical evaluation of the hardware. The signal of a bipolar EMG electrode is amplified by an operational amplifier. This potential is added to a voltage-controlled crystal oscillator (27 MHz, bandwidth: 4 kHz), frequency-converted, and transmitted from an antenna about 10 cm long (diameter: 0.03 mm). The power source is a 1.55-V wristwatch battery that has a total weight of about 0.3 g (one dry battery and analog circuit) and an expected operating time of 20 minutes. The output power is -7 dBm and the effective isotropic radiated power is -40 dBm. The signal is received by a dual-whip antenna (2.15 dBi) at a distance of about 100 m from the moth. The link margin of the communication circuit is above 30 dB within 100 m. The concepts of this hardware and the measurement data are presented in this paper. This will be the first biological data transmission from a moth with an official license. In future, this telemetry system will improve the detection of physiological abnormalities of moths.

Optimal Design of VCO Using Spiral Inductor (나선형 인덕터를 이용한 VCO 최적설계)

  • Kim, Yeong-Seok;Park, Jong-Uk;Kim, Chi-Won;Bae, Gi-Seong;Kim, Nam-Su
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.39 no.5
    • /
    • pp.8-15
    • /
    • 2002
  • We optimally designed the VCO(voltage-controlled oscillator) with spiral inductor using the MOSIS HP 0.5${\mu}{\textrm}{m}$ CMOS process. With the developed SPICE model of spiral inductor, the quality factor of spiral inductor was maximized at the operating frequency by varying the layout parameters, e.g., metal width, number of turns, radius, space of the metal lines. For the operation frequency of 2㎓, the inductance of about 3nH, and the MOSIS HP 0.5 CMOS process with the metal thickness of 0.8${\mu}{\textrm}{m}$, oxide thickness of 3${\mu}{\textrm}{m}$, the optimal width of metal lines is about 20${\mu}{\textrm}{m}$ for the maximum Quality factor. With the optimized spiral inductor, the VCO with LC tuning tank was designed, fabricated and measured. The measurements were peformed on-wafer using the HP8593E spectrum analyzer. The oscillation frequency was about 1.610Hz, the frequency variation of 250MHz(15%) with control voltage of 0V - 2V, and the phase noise of -108.4㏈c(@600KHz) from output spectrum.

Fractional-N PLL Frequency Synthesizer Design (Fractional-N PLL (Phase-Locked Loop) 주파수 합성기 설계)

  • Kim Sun-Cheo;Won Hee-Seok;Kim Young-Sik
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.42 no.7 s.337
    • /
    • pp.35-40
    • /
    • 2005
  • This paper proposes a fractional-N phase-locked loop (PLL) frequency synthesizer using the 3rd order ${\Delta}{\sum}$ modulator for 900MHz medium speed wireless link. The LC voltage-controlled oscillator (VCO) is used for the good phase noise property. To reduce the lock-in time, a charge pump has been developed to control the pumping current according to the frequency steps and the reference frequency is increased up to 3MHz. A 36/37 fractional-N divider is used to increase the reference frequency of the phase frequency detector (PFD) and to reduce the minimum frequency step simultaneously. A 3rd order ${\Delta}{\sum}$ modulator has been developed to reduce the fractional spur VCO, Divider by 8 Prescaler, PFD and Charge pump have been developed with 0.25um CMOS, and the fractional-N divider and the third order ${\Delta}{\sum}$ modulator have been designed with the VHDL code, and they are implemented through the FPGA board of the Xilinx Spartan2E. The measured results show that the output power of the PLL is about -lldBm and the phase noise is -77.75dBc/Hz at 100kHz offset frequency. The minimum frequency step and the maximum lock-in time are 10kHz and around 800us for the maximum frequency change of 10MHz, respectively.

Low Phase Noise VCO Using Novel Harmonic Control Circuit Based on Composite Right/Left-Handed Transmission Line (혼합 우좌향 전송 선로 기반의 새로운 고조파 조절 회로를 이용한 저위상 잡음 전압 제어 발진기)

  • Choi, Jae-Won;Seo, Chul-Hun
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.47 no.1
    • /
    • pp.84-90
    • /
    • 2010
  • In this paper, a novel voltage-controlled oscillator (VCO) using the harmonic control circuit based on the composite right/left-handed (CRLH) transmission lines (TLs) is presented to reduce the phase noise without the reduction of the frequency tuning range and miniaturize the circuit size. The phase noise is reduced by the novel harmonic control circuit having the short impedances for the second- and third-harmonic components. The proposed harmonic control circuit is designed by using the CRLH TLs with the dual-band characteristic by the frequency offset and phase slope of the CRLH TLs. The high-Q resonator has been used to reduce the phase noise, but has the problem of the frequency tuning range reduction. However, the frequency tuning range of the proposed VCO has not been reduced because the phase noise has been reduced without the high-Q resonator. The miniaturization of the circuit size is achieved by using the CRLH TLs instead of the conventional right-handed (RH) TLs. The phase noise of VCO is -119.17 ~ -117.50 dBc/Hz at 100 kHz in the tuning range of 5.731 ~ 5.938 GHz.

Low Phase Noise VCO using Microstrip Square Open Loop Multiple Split Ring Resonator (마이크로스트립 사각 개방 루프 다중 SRR(Split Ring Resonator)를 이용한 저위상 잡음 전압 제어 발진기)

  • Choi, Jae-Won;Seo, Chul-Hun
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.44 no.11
    • /
    • pp.60-66
    • /
    • 2007
  • In this paper, a novel voltage-controlled oscillator (VCO) using the microstrip square open loop multiple split ring resonator (OLMSRR) is presented for reducing the phase noise property. The square-shaped multiple split ring resonator (MSRR) having the form of the microstrip square open loop is investigated to realize this property. Compared with the microstrip square open loop resonator and the microstrip square open loop split ring resonator (OLSRR) as well as the conventional microstrip line resonator, the microstrip square OLMSRR has the larger coupling coefficient value, which makes a higher Q value, and has reduced the phase noise of VCO. The VCO with 1.7V power suppIy has the phase noise of $-124.5\;{\sim}\;-122.0\;dBc/Hz$ @ 100 kHz in the tuning range, $5.746\;{\sim}\;5.84\;GHz$. The figure of merit (FOM) of this VCO is $-203.96\;{\sim}\;-201.6\;dBc/Hz$ @ 100 kHz in the same tuning range. Compared with VCO using the conventional microstrip line resonator, VCO using the microstrip square open loop resonator and VCO using microstrip square OLSRR, the phase noise property of VCO using the proposed resonator has been improved in 25.66 dB, 8.34 dB, and 4.5 dB, respectively.

A 2.4 GHz Bio-Radar System with Small Size and Improved Noise Performance Using Single Circular-Polarized Antenna and PLL (하나의 원형 편파 안테나와 PLL을 이용하여 소형이면서도 개선된 잡음 성능을 갖는 2.4 GHz 바이오 레이더 시스템)

  • Jang, Byung-Jun;Park, Jae-Hyung;Yook, Jong-Gwan;Moon, Jun-Ho;Lee, Kyoung-Joung
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.20 no.12
    • /
    • pp.1325-1332
    • /
    • 2009
  • In this paper, we design a 2.4 GHz bio-radar system that can detect human heartbeat and respiration signals with small size and improved noise performance using single circular-polarized antenna and phase-locked loop. The demonstrated bio-radar system consists of single circular-polarized antenna with $90^{\circ}$ hybrid, low-noise amplifier, power amplifier, voltage-controlled oscillator with phase-locked loop circuits, quadrature demodulator and analog circuits. To realize compact size, the printed annular ring stacked microstrip antenna is integrated on the transceiver circuits, so its dimension is just $40\times40mm^2$. Also, to improve signal-to-noise-ratio performance by phase noise due to transmitter leakage signal, the phase-locked loop circuit is used. The measured results show that the heart rate and respiration accuracy was found to be very high for the distance of 50 cm without the additional digital signal processing.

Low Phase Noise VCO with X -Band Using Metamaterial Structure of Dual Square Loop (메타구조의 이중 사각 루프를 이용한 X-Band 전압 제어 발진기 구현에 관한 연구)

  • Shin, Doo-Soub;Seo, Chul-Hun
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.47 no.12
    • /
    • pp.84-89
    • /
    • 2010
  • In this paper, a novel voltage-controlled oscillator (VCO) using the microstrip square open loop dual split ring resonator is presented for reducing the phase noise. The square-shaped dual split ring resonator having the form of the microstrip square open loop is investigated to reduce the phase noise. Compared with the microstrip square open loop resonator and the microstrip square open loop split ring resonator as well as the conventional microstrip line resonator, the microstrip square dual split ring resonator has the larger coupling coefficient value, which makes a higher Q value, and has reduced the phase noise of VCO. The VCO with 1.7V power supply has the phase noise of -123.2~-122.0 dBc/Hz @ 100 kHz in the tuning range, 11.74~11.75 GHz. The figure of merit (FOM) of this VCO is-214.8~-221.7 dBc/Hz dBc/Hz @ 100 kHz in the same tuning range. Compared with VCO using the conventional microstrip line resonator, VCO using microstrip square open loop resonator, the phase noise of VCO using the proposed resonator has been improved in 26 dB, 10 dB, respectively.

Low Phase Noise VCO using Output Matching Network Based on Harmonic Control Circuit (고조파 조절 회로를 기반으로 한 출력 정합 회로를 이용한 저위상 잡음 전압 제어 발진기)

  • Choi, Jae-Won;Seo, Chul-Hun
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.45 no.2
    • /
    • pp.137-144
    • /
    • 2008
  • In this paper, a novel voltage-controlled oscillator(VCO) using the output matching network based on the harmonic control circuit is presented for improving the phase noise property. The phase noise suppression is achieved through the harmonic control circuit having the short impedances for both second-harmonic and third-harmonic components, which has been connected at the output matching network. Also, we have used the microstrip square open loop multiple split-ring resonator(OLMSRR) having the high-Q property to further reduce the phase noise of VCO. Because the output matching network based on the harmonic control circuit has been used for reducing the phase noise property instead of the High-Q resonator, we can obtain the broad tuning range by the low-Q resonator. The phase noise of the proposed VCO using the output matching network based on the harmonic control circuit and the microstrip square OLMSRR has been $-127.5{\sim}126.33$ dBc/Hz @ 100 kHz in the tuning range, $5.744{\sim}5.839$ GHz. Compared with the reference VCO using the output matching network without the harmonic control circuit and the microstrip line resonator, the phase noise property of the proposed VCO has been improved in 26.66 dB.

Design of Q-Band LC VCO and Injection Locking Buffer 77 GHz Automotive Radar Sensor (77 GHz 자동차용 레이더 센서 응용을 위한 Q-밴드 LC 전압 제어 발진기와 주입 잠금 버퍼 설계)

  • Choi, Kyu-Jin;Song, Jae-Hoon;Kim, Seong-Kyun;Cui, Chenglin;Nam, Sang-Wook;Kim, Byung-Sung
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.22 no.3
    • /
    • pp.399-405
    • /
    • 2011
  • In this paper, we present the design of Q-band LC VCO and injection locking buffer for 77 GHz automotive radar sensor using 130 nm RF CMOS process. To improve the phase noise characteristic of LC tank, the transmission line is used. The negative resistance by the active device cross-coupled pair of buffer is used for high output power, with or without oscillation of buffer. The measured phase noise is -102 dBc/Hz at 1 MHz offset frequency and tuning range is 34.53~35.07 GHz. The output power is higher than 4.1 dBm over entire tuning range. The fabricated chip size is $510{\times}130\;um^2$. The power consumption of LC VCO is 10.8 mW and injection locking buffer is 50.4 mW from 1.2 V supply.

Introduction to Electrochemical Quartz Crystal Microbalance Technique for Leaching Study of Metals (금속 침출연구를 위한 전기화학적 미소수정진동자저울 기술 소개)

  • Kim, Min-seuk;Chung, Kyeong Woo;Lee, Jae-chun
    • Resources Recycling
    • /
    • v.29 no.1
    • /
    • pp.25-34
    • /
    • 2020
  • Electrochemical Quartz Crystal microbalance is a tool that is capable of measuring nanogram-scale mass change on electrode surface. When applying alternating voltage to the quartz crystal with metal electrode formed on both sides, a resonant frequency by inverse piezoelectric effect depends on its thickness. The resonant frequency changes sensitively by mass change on its electrode surface; frequency increase with metal dissolution and decrease with metal deposition on the electrode surface. The relationship between resonant frequency and mass change is shown by Sauerbrey equation so that the mass change during metal dissolution can be measured in real time. Especially, it is effective in the case of reaction mechanism and rate studies accompanied by precipitation, volatilization, compound formation, etc. resulting in difficulties on ex-situ AA or ICP analysis. However, it should be carefully considered during EQCM experiments that temperature, viscosity, and hydraulic pressure of solution, and stress and surface roughness can affect on the resonant frequency. Application of EQCM was shown as a case study on leaching of platinum using aqueous chlorine for obtaining activation energy. A platinum electrode of quartz crystal oscillator with 1000 Å thickness exposed to solution was used as leaching sample. Electrogenerated chlorine as oxidant was purged and its concentration was controlled in hydrochloric acid solution. From the experimental results, platinum dissolution by chlorine is chemical reaction control with activation energy of 83.5 kJ/mol.