• 제목/요약/키워드: Voltage sensitivity analysis

검색결과 134건 처리시간 0.025초

정상상태시 전압유지를 위한 TCSC의 최적 위치 선정에 관한 연구 (Selection of Optimal TCSC Location to Keep the Steady-state Voltage Profile within limits)

  • 임정욱;서장철;문승일
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 C
    • /
    • pp.1063-1065
    • /
    • 1998
  • This paper discusses the selection of optimal location of Thyristor Controlled Series Compensator (TCSC) devices to maintain the steady-state voltage profile within limits. A procedure for selecting optimal TCSC location based on sensitivity analysis is developed. This approach identifies the critical lines by evaluating all the voltage magnitudes sensitivity with respect to a line reactance. Computer simulation of a example system is used to verify the proposed procedure.

  • PDF

용접 비드 형상에 대한 용접공정 변수의 민감도 해석에 관한 연구 (A study on the sensitivity analysis of welding process parameters on weld bead geometry)

  • 이세환
    • 한국공작기계학회:학술대회논문집
    • /
    • 한국공작기계학회 1998년도 춘계학술대회 논문집
    • /
    • pp.274-280
    • /
    • 1998
  • The welding technology and qualities are developed significantly, in recent years, in the use of automated processing technology and welding robot systems. But these automated welding technologies have many difficulties for finding the optimal welding parameter conditions. Because of the lack of mathematical model for determination of optimal welding process parameters. In this study, the sensitivity analysis of the empirical equations for finding weld bead width, height and penetration depth by using the published formulae. The selected major welding process parameters effected to weld bead geometries are the welding speed, current, voltage and weld wire diameter.

  • PDF

Loss Optimization for Voltage Stability Enhancement Incorporating UPFC Using Particle Swarm Optimization

  • Kowsalya, M.;Ray, K.K.;Kothari, D.P.
    • Journal of Electrical Engineering and Technology
    • /
    • 제4권4호
    • /
    • pp.492-498
    • /
    • 2009
  • The placement of the UPFC is the major concern to ensure the full potential of utilization in the transmission network. Voltage stability enhancement with the optimal placement of UPFC using stability index such as modal analysis, Voltage Phasor method is made and the loss minimization including UPFC is formulated as an optimization problem. This paper proposes particle swarm optimization for the exact real power loss minimization including UPFC. The implementation of loss minimization for the optimal location of UPFC was tested with IEEE-14 and IEEE-57 bus system.

동적전압붕괴에 대한 외란의 영향평가 및 제어기기 적용효과 분석 (The Analysis and Evaluation of the Disturbances and Controller Effects to Power System Dynamic Voltage Stability)

  • 이근준;추진부;김건중
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1997년도 하계학술대회 논문집 D
    • /
    • pp.886-890
    • /
    • 1997
  • This paper presents shows various process of dynamic voltage collapses which were initiated by power system disturbances, and the impacts of dynamic voltage controllers. According to the analysis results, the composition of induction motors with short time constant strongly affect the voltage collapse. To escape the voltage collapse, adding fast acting reactive compensation device, such as SVC, at high reactive loss sensitivity(${\partia}Qloss/{\partia}PL$) point could be one of a good countermeasure.

  • PDF

전압 변동률을 고려한 수도권 전압 안정화 다단계 부하차단 적용 방안 (Multi-level UnderVoltage Load Shedding Scheme Considering Rate of Change of Voltage for Voltage Stability)

  • 이윤환;김태균;김지훈;이병준;강부일;조종만
    • 전기학회논문지
    • /
    • 제58권12호
    • /
    • pp.2335-2341
    • /
    • 2009
  • High technique growth of modem times and high industrial facility in consequence of buildings demand for electric power of an extensive scale with stability supply and maintenance of high quality. But, power system always have risk of network contingency. When power system break out disturbance, it circumstantially happen like uncontrolled loss of load developing from of cascading. Severely which would be raised wide area blackout, plan to prevent, which make stability through a little of load shedding and multi-level UnderVoltageLoadShdding should work. This paper presents target, sensitivity of bus voltage have choose appropriating load shedding location and load shedding decision making logic with considering rate of change of voltage have studied multi-level under voltage load shedding scheme. Calculation of rate of change of voltage applied method of least square. As a result, we are studied an dynamic analysis of 2008 summer peak data. We have been known that network analysis is a little development and developing UnderVoltageLoadShedding scheme.

A Techno-Economic Feasibility Analysis on LVDC Distribution System for Rural Electrification in South Korea

  • Afamefuna, David;Chung, Il-Yop;Hur, Don;Kim, Ju-Yong;Cho, Jintae
    • Journal of Electrical Engineering and Technology
    • /
    • 제9권5호
    • /
    • pp.1501-1510
    • /
    • 2014
  • Low voltage direct current (LVDC) distribution system is a suitable techno-economic candidate which can create an innovative solution for distribution network development with respect to rural electrification. This research focuses on the use of LVDC distribution system to replace some of KEPCO's existing traditional medium voltage alternating current (MVAC) distribution network for rural electrification in South Korea. Considering the technical and economic risks and benefits involved in such project, a comparative techno-economic analysis on the LVDC and the MVAC distribution networks is conducted using economic assessment method such as the net present value (NPV) on a discounted cash flow (DCF) basis as well as the sensitivity analysis technique. Each would play a role in an economic performance indicator and a measure of uncertainty and risk involved in the project. In this work, a simulation model and a computational tool are concurrently developed and employed to aid the techno-economic analysis, evaluation, and estimation of the various systems efficiency and/or performance.

고유치감도 해석에 의한 전압안정도의 상정사고 선택 (Contingency Selection Using Eigen-Sensitivity Analysis for Voltage Stability.)

  • 송성근;남해곤;심관식;문영환;최흥관;남궁재용
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 A
    • /
    • pp.66-68
    • /
    • 2000
  • The Eigen analysis in large power system provides much useful information that is not got in nose curve. The branch participation factor is not quantitative information and is an indirect method calculating incremental change in branch reactive loss. But the Eigen sensitivity analysis to each mode is direct and provides of quantitative information but this method because of needing much time is used in large power system. In this paper the Hessenberg method is used to obtaining dominant eignvalues and corresponding eigenvectors of Jacobian matrix. Ranking the critical contingencies is done by computing the Eigen sensitivity of each dominant eignvalues for changes of each line. The proposed algorithm is tested on the New England 30-bus system and KEPCO system in the year of 2000, which comprises of 791-bus and 2500-branches.

  • PDF

LVDT의 출력 특성에 미치는 공정 및 재료 변수의 영향에 관한 유한요소해석 (Finite Element Analysis of the Effects of Process and Material Parameters on the LVDT Output Characteristics)

  • 양영수;배강열
    • 한국기계가공학회지
    • /
    • 제20권9호
    • /
    • pp.11-19
    • /
    • 2021
  • Linear variable differential transformer (LVDT) is a displacement sensor and is commonly used owing to its wide measurement range, excellent linearity, high sensitivity, and precision. To improve the output characteristics of LVDT, a few studies have been conducted to analyze the output using a theoretical method or a finite element method. However, the material properties of the core and the electromagnetic force acting on the core were not considered in the previous studies. In this study, a finite element analysis model was proposed considering the characteristics of the LVDT composed of coils, core, magnetic shell and electric circuit, and the core displacement. Using the proposed model, changes in sensitivity and linear region of LVDT according to changes in process and material parameters were analyzed. The outputs of the LVDT model were compared with those of the theoretical analysis, and then, the proposed analysis model was validated. When the electrical conductivity of the core was high and the relative magnetic permeability was low, the decrease in sensitivity was large. Additionally, an increase in the frequency of the power led to further decrease in sensitivity. The electromagnetic force applied on the core increased as the voltage increased, the frequency decreased, and the core displacement increased.

EMTP를 이용한 전압 불안정 현상의 동적 시뮬레이션 (A Dynamic Simulation of Voltage Instability Using EMTP)

  • 허정용;김철환
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제52권6호
    • /
    • pp.295-300
    • /
    • 2003
  • Voltage instability has been studied for some decade now. But, There is not generally accepted definition of voltage instability because of the complex phenomenon and the variety of ways in which it can manifest itself. Both IEEE and CIGRE have the respective definitions. The areas of voltage instability research are the analysis, simulation and countermeasure of voltage instability. It needs to model the components of the power system to simulate the voltage instability and voltage collapse. At the beginning, the static simulation was used. This method provides the voltage stability indices and it requires less CPU resource and gives much insight into the voltage and power problem. However, it is less accurate than the dynamic simulation peformed in the time domain simulation. So, when it appears difficult to secure the voltage stability margin in a static stability, it is necessary to perform the dynamic simulation. To perform time-domain simulation, we have to model the dynamic component of the power system like a generator and a load. The dynamic simulation provides the accurate result of the voltage instability. But, it is not able to provide the sensitivity information or the degree of stability and it is time consuming and it needs much CPU resource. In this Paper, we perform a dynamic simulation of voltage instability and voltage collapse using EMTP MODELS. The exponential load model is designed with MODEIS and this load model is connected with test power system. The result shows the process of voltage change in time domain when the voltage instability or voltage collapse occurs.