• Title/Summary/Keyword: Voltage range

Search Result 2,914, Processing Time 0.026 seconds

Properties of Longitudinal & Transverse Discharge in a Tubular Fluorescent Lamp (직관형 형광램프의 종단방전과 횡단방전의 특성)

  • Chung, J.Y.;Kim, J.H.;Jeong, J.M.;Jin, D.J.;Kim, H.C.;Bong, J.H.;Hwang, H.C.;Lee, M.S.;Koo, J.H.;Cho, G.S.
    • Journal of the Korean Vacuum Society
    • /
    • v.17 no.4
    • /
    • pp.322-330
    • /
    • 2008
  • The properties of discharge, luminance, and spectroscopy are investigated in a longitudinal and transverse discharge fluorescent lamps with tube of outer diameter 4 mm. The sample lamps are prepared to be three kinds of gas composition such as mercury lamps of Ne(95%)+Ar(5%)+Hg(2 mg), the mercury-free lamps of Xe 100% and Ne+Xe(4%). The gas pressure is in the range of $5{\sim}300\;Torr$. In the mercury lamps, the longitudinal discharge having a positive column is high in luminance and efficiency, while the transverse discharge is no luminance at all. In the Xe-lamps, the transverse discharge shows relatively good in efficiency as compared with the longitudinal discharge which has a high discharge voltage and a low luminance and efficiency. In the transverse discharge of relatively high efficiency, a pure Xe(100%) gas discharge has a higher efficiency than the mixture gas of Ne+Xe(4%). Through these experiments, the properties of mercury and xenon lamps are verified. In the mercury lamps, the longitudinal discharge of tubular fluorescent lamps is high in luminance and efficiency, while the transverse discharge of flat panel fluorescent lamps are low in luminance efficiency. In the mercury-free lamps, the flat fluorescent lamps of transverse discharge having a high pressure ${\sim}100\;Torr$ with the pure Xe-gas are verified to be suggestable.

Studies on electrocardiogram of the normal Korean native cattle II. Wave forms and amplitudes of the unipolar precordial chest leads (정상적(正常的)인 한우(韓牛)의 심전도(心電圖)에 관(關)한 연구(硏究) II. 흉부단극유도(胸部單極誘導)의 파형(波形)과 전위(電位))

  • Choi, In-hyuk;Kim, Soo-young;Kim, Nam-soo;Suh, Doo-seok
    • Korean Journal of Veterinary Research
    • /
    • v.33 no.4
    • /
    • pp.735-746
    • /
    • 1993
  • Electrocardiographic parameters of amplitude and the shape of waves on the unipolar precordial chest leads in the normal Korean native cattles have been measured with a 3 channel electrocardiograph built in a computed and analysis. The study was conducted on 98 heads of mean age of 17.6 months. The wave forms of P, T and QRS complex wave in all leads showed various types. The parameters of the amplitude in the wave types showed the most frequency in each lead that were analyzed as follow : 1. In P wave, amplitudes of positive type showed a frequency of 92.9% and 93.9% in leads $CV_6LU$ and $CV_6LL$ that were $83.8{\pm}31.0{\mu}V$ and $76.0{\pm}30.7{\mu}V$, and negative type showed a frequency of 97.9% in lead V 10 that were $-80.2{\pm}29.4{\mu}V$, respectively. But the plate type in leads $CV_6RU$ and $CV_6RL$ showed frequency of 48% and 58.3%, respectively. 2. Average amplitude of the QRS complex were in a range of $277.0{\pm}154.0{\mu}V$ to $648.2{\pm}146.2{\mu}V$(mean of $418.8{\pm}139.4{\mu}V$) in all leads that were manifested the Low-Voltage QRS complex(below 1 mV in unipolar precordial leads). Average amplitudes of each wave type in the QRS complex were $-250.0{\pm}139.8{\mu}V$ and $-399.2{\pm}226.8{\mu}V$ in the QS group types that showed a frequency of 50.0% and 82.5% in the leads $CV_6LU$ and $CV_6LL$, respectively. And average amplitudes of the R group types showed a frequency of 85.6%, 56.1% and 75.8% in the $CV_6RU$, $CV_6RL$ and $V_{10}$ that were $321.5{\pm}142.1{\mu}V$, $271.6{\pm}139.9{\mu}V$ and $552.4{\pm}132.7{\mu}V$, respectively. 3. In T waves, Amplitudes of the positive type showed a frequency of 60.2%, 46.9% and 83.7% in leads of $CV_6LL$, $CV_6RU$ and $CV_6RL$ that were respectively $184.7{\pm}93.7{\mu}V$ $103.7{\pm}64.43{\mu}V$ and $111.8{\pm}39.3{\mu}V$, the negative type showed a frequency of 62.2% and 93.7% in leads $CV_6LU$ and $V_{10}$ that were $142.2{\pm}82.1{\mu}V$ and $-280.3{\pm}107.2{\mu}V$, respectively. 4. Average amplitude of ST segment were $3.7{\pm}33.1{\mu}V$, $0.9{\pm}23.1{\mu}V$, $10.9{\pm}28.6{\mu}V$, $5.8{\pm}28.3{\mu}V$ and $-34.7{\pm}48.4{\mu}V$ in leads $CV_6LL$, $CV_6RU$, $CV_6RL$, $CV_6LU$ and $V_{10}$ respectively.

  • PDF

Improvement of Energy Density in Supercapacitor by Ion Doping Control for Energy Storage System (에너지 저장장치용 슈퍼커패시터 이온 도핑 제어를 통한 에너지 밀도 향상 연구)

  • Park, Byung-jun;Yoo, SeonMi;Yang, SeongEun;Han, SangChul;No, TaeMoo;Lee, Young Hee;Han, YoungHee
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.5 no.3
    • /
    • pp.209-213
    • /
    • 2019
  • Recently, demand for high energy density and long cycling stability of energy storage system has increased for application using with frequency regulation (F/R) in power grid. Supercapacitor have long lifetime and high charge and discharge rate, it is very adaptable to apply a frequency regulation in power grid. Supercapacitor can complement batteries to reduce the size and installation of batteries. Because their utilization in a system can potentially eliminate the need for short-term frequent replacement as required by batteries, hence, saving the resources invested in the upkeep of the whole system or extension of lifecycle of batteries in the long run of power grid. However, low energy density in supercapacitor is critical weakness to utilization for huge energy storage system of power grid. So, it is still far from being able to replace batteries and struggle in meeting the demand for a high energy density. But, today, LIC (Lithium Ion Capacitor) considered as an attractive structure to improve energy density much more than EDLC (Electric double layer capacitor) because LIC has high voltage range up to 3.8 V. But, many aspects of the electrochemical performance of LIC still need to be examined closely in order to apply for commercial use. In this study, in order to improve the capacitance of LIC related with energy density, we designed new method of pre-doping in anode electrode. The electrode in cathode were fabricated in dry room which has a relative humidity under 0.1% and constant electrode thickness over $100{\mu}m$ was manufactured for stable mechanical strength and anode doping. To minimize of contact resistance, fabricated electrode was conducted hot compression process from room temperature to $65^{\circ}C$. We designed various pre-doping method for LIC structure and analyzing the doping mechanism issues. Finally, we suggest new pre-doping method to improve the capacitance and electrochemical stability for LIC.

Usefulness of Abdominal Compressor Using Stereotactic Body Radiotherapy with Hepatocellular Carcinoma Patients (토모테라피를 이용한 간암환자의 정위적 방사선치료시 복부압박장치의 유용성 평가)

  • Woo, Joong-Yeol;Kim, Joo-Ho;Kim, Joon-Won;Baek, Jong-Geal;Park, Kwang-Soon;Lee, Jong-Min;Son, Dong-Min;Lee, Sang-Kyoo;Jeon, Byeong-Chul;Cho, Jeong-Hee
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.24 no.2
    • /
    • pp.157-165
    • /
    • 2012
  • Purpose: We evaluated usefulness of abdominal compressor for stereotactic body radiotherapy (SBRT) with unresectable hepatocellular carcinoma (HCC) patients and hepato-biliary cancer and metastatic liver cancer patients. Materials and Methods: From November 2011 to March 2012, we selected HCC patients who gained reduction of diaphragm movement >1 cm through abdominal compressor (diaphragm control, elekta, sweden) for HT (Hi-Art Tomotherapy, USA). We got planning computed tomography (CT) images and 4 dimensional (4D) images through 4D CT (somatom sensation, siemens, germany). The gross tumor volume (GTV) included a gross tumor and margins considering tumor movement. The planning target volume (PTV) included a 5 to 7 mm safety margin around GTV. We classified patients into two groups according to distance between tumor and organs at risk (OAR, stomach, duodenum, bowel). Patients with the distance more than 1 cm are classified as the 1st group and they received SBRT of 4 or 5 fractions. Patients with the distance less than 1 cm are classified as the 2nd group and they received tomotherapy of 20 fractions. Megavoltage computed tomography (MVCT) were performed 4 or 10 fractions. When we verify a MVCT fusion considering priority to liver than bone-technique. We sent MVCT images to Mim_vista (Mimsoftware, ver .5.4. USA) and we re-delineated stomach, duodenum and bowel to bowel_organ and delineated liver. First, we analyzed MVCT images to check the setup variation. Second we compared dose difference between tumor and OAR based on adaptive dose through adaptive planning station and Mim_vista. Results: Average setup variation from MVCT was $-0.66{\pm}1.53$ mm (left-right) $0.39{\pm}4.17$ mm (superior-inferior), $0.71{\pm}1.74$ mm (anterior-posterior), $-0.18{\pm}0.30$ degrees (roll). 1st group ($d{\geq}1$) and 2nd group (d<1) were similar to setup variation. 1st group ($d{\geq}1$) of $V_{diff3%}$ (volume of 3% difference of dose) of GTV through adaptive planing station was $0.78{\pm}0.05%$, PTV was $9.97{\pm}3.62%$, $V_{diff5%}$ was GTV 0.0%, PTV was $2.9{\pm}0.95%$, maximum dose difference rate of bowel_organ was $-6.85{\pm}1.11%$. 2nd Group (d<1) GTV of $V_{diff3%}$ was $1.62{\pm}0.55%$, PTV was $8.61{\pm}2.01%$, $V_{diff5%}$ of GTV was 0.0%, PTV was $5.33{\pm}2.32%$, maximum dose difference rate of bowel_organ was $28.33{\pm}24.41%$. Conclusion: Despite we saw diaphragm movement more than 5 mm with flouroscopy after use an abdominal compressor, average setup_variation from MVCT was less than 5 mm. Therefore, we could estimate the range of setup_error within a 5 mm. Target's dose difference rate of 1st group ($d{\geq}1$) and 2nd group (d<1) were similar, while 1st group ($d{\geq}1$) and 2nd group (d<1)'s bowel_organ's maximum dose difference rate's maximum difference was more than 35%, 1st group ($d{\geq}1$)'s bowel_organ's maximum dose difference rate was smaller than 2nd group (d<1). When applicating SBRT to HCC, abdominal compressor is useful to control diaphragm movement in selected patients with more than 1 cm bowel_organ distance.

  • PDF