• Title/Summary/Keyword: Voltage profile

Search Result 355, Processing Time 0.027 seconds

A Spread Spectrum Clock Generator for SATA II with Rounded Hershey-Kiss Modulation Profile

  • Moon, Yong-Hwan;Lim, Wan-Sik;Kim, Tae-Ho;Kang, Jin-Ku
    • Journal of IKEEE
    • /
    • v.15 no.2
    • /
    • pp.129-133
    • /
    • 2011
  • A spread spectrum clock generation is an efficient way to reduce electro-magnetic interference (EMI) radiation in modern mixed signal chip systems. The proposed circuit generates the spread spectrum clock by directly injecting the modulation voltage into the voltage-controlled oscillator (VCO) current source for SATA II. The resulting 33KHz modulation profile has a Hersey-Kiss shape with a rounded peak. The chip has been fabricated using $0.18{\mu}m$ CMOS process and test results show that the proposed circuit achieves 0.509% (5090ppm) down spreading at 1.5GHz and peak power reduction of 10dB. The active chip area is 0.36mm ${\times}$ 0.49mm and the chip consumes 30mW power at 1.5GHz.

A Study on Capacitor Placement Using ESGA Hybrid Approach in Unbalanced Distribution Systems (ESGA를 이용한 불평형 배전계통의 커패시터 설치에 관한 연구)

  • 김규호;이유정;이상봉;유석구
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.52 no.6
    • /
    • pp.316-324
    • /
    • 2003
  • This paper applied Elite-based Simplex-GA hybrid approach combined with Muptipop-GA (ESGA) to determining the location, size and number of capacitors to improve voltage profile and minimize power losses in unbalanced distribution systems. One of the main obstacles in applying GA to complex problems has been the high computational cost due to their slow convergence rate. To alleviate this difficulty, ESGA approach was developed that combines Elite-based Simplex-GA hybrid approach with Muptipop-GA. The objective function formulated consists of two terms: cost for energy losses and cost related to capacitor purchase and capacitor installation. The cost function associated with capacitor placement is considered as a step function due to banks of standard discrete capacities. Its efficiency was proved through the application in IEEE 13 bus and 34 bus test systems and was compared with several methods using GA.

Coordinated Control of SVC and ULTC Considering Dynamic Voltage Stability (동적전압안정도를 고려한 SVC와 ULTC의 협조제어)

  • Moon, Kyeong-S.;Park, Young-O.;Lee, Song-K.;Park, Jong-K.;Son, Kwang-M.
    • Proceedings of the KIEE Conference
    • /
    • 1997.07c
    • /
    • pp.1097-1099
    • /
    • 1997
  • The implementation of Static Var Compensator(SVC) provides opportunites to maintain voltage profile and improve voltage stability in large scale power system. Under Load Tap Changing(ULTC) transformer has been used to control the voltage. It is necessary that Coordinated control of SVC and ULTC for the better performance. This paper shows that the characteristic of Voltage control using SVC or ULTC and the condition of the coordinated control considering dynamic voltage stability.

  • PDF

A Study on Voltage and Reactive Power Control Methodology using Integer Programming and Local Subsystem (지역 계통 구성과 Integer programming을 이용한 전압 및 무효전력 제어방안 연구)

  • Kim, Tae-Kyun;Choi, Yun-Hyuk;Seo, Sang-Soo;Lee, Byong-Jun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.4
    • /
    • pp.543-550
    • /
    • 2008
  • This paper proposes an voltage and reactive power control methodology, which is motivated towards implementation in the korea power system. The main voltage control devices are capacitor banks, reactor banks and LTC transformers. Effects of control devices are evaluated by local subsystem's cost computations. This local subsystem is decided by 'Tier' and 'Electrical distance' in the whole system. The control objective at present is to keep the voltage profile within constraints with minimum switching cost. A robust control strategy is proposed to make the control feasible and optimal for a set of power-flow cases that may occur important event from system. This studies conducted for IEEE 39-bus low and high voltage contingency cases indicate that the proposed control methodology is much more effective than PSS/E simulation tool in deciding switching of capacitor and reactor banks.

Cooperated control between Load Tap Changer, Shunt Capacitor, FACTS in substation for voltage profile improvement (전압 Profile 개선을 위한 변전소 내의 LTC, S.C, FACTS간 협조제어 연구)

  • Lee, Gil-Soo;Kang, Sang-Gyun;Lee, Byung-Jun
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.167-168
    • /
    • 2008
  • 이 논문은 변전소 환경에서 LTC, S.C, FACTS 간의 협조제어를 통한 전압 profile 개선을 논한다. 변전소 자체 내의 전압-무효전력 제어기기인 LTC, S.C 이외에도 현재에는 더 나은 전력전송과 전압안정을 위해 FACTS를 설치하는 경우가 늘고 있기 때문에 위의 3가지기기에 대한 협조제어 알고리즘에 대한 필요성은 점차 증대된다고 할 수 있다. 이러한 3가지 기기들의 협조제어를 통해서 전압 profile 개선에 관하여 연구하였으며 그러한 연구들은 Hypersim(real-time simulator) 기반에서 수행하였다.

  • PDF

An Maximization of Ionic Wind Utilizing a Cylindrical Corona Electrode (관형 코로나 방전전극을 이용한 이온풍속의 최대화)

  • Jung, Jae-Seung;Moon, Jae-Duk
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.59 no.12
    • /
    • pp.2256-2261
    • /
    • 2010
  • A corona discharge system with needle point or wire type corona electrode has been well used as an ionic wind blower. The corona discharge system with a needle point electrode produces ions at lower applied voltage effectively. However, the corona discharge on the needle point electrode transits to the arc discharge at lower voltage, and it is hard to obtain the elevated electric field in the discharge airgap for enhancing the ion migration velocity due to the weak Coulomb force. A cylindrical corona electrode with sharp round tip is reported as one of effective corona electrode, because of its higher breakdown voltage than that of the needle electrode. A basic study, for the effectiveness of cylindrical electrode shape on the ionic wind generation, has been investigated to obtain an maximum wind velocity, which however is the final goal for the real field application of this kind ionic wind blower. In this paper, a parametric study for maximizing the ionic wind velocity utilizing the cylindrical corona electrode and a maximum ion wind velocity of 4.1 m/s were obtained, which is about 1.8 times higher than that of 2.3m/s obtained with the needle corona electrode from the velocity profile.

Integrated Thyristor Switch Structures for Capacitor Discharge Application

  • Kim, Eun-Dong;Zhang, Chang-Li;Kim, Sang-Cheol;Baek, Do-Hyun
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.05b
    • /
    • pp.22-25
    • /
    • 2001
  • A thyristor switch circuit for capacitor discharge application, of which the equivalent circuit includes a resistor between cathode and gate of a reverse-conducting thyristor and an avalanche diode anti-parallel between its anode and gate to set thyristor tum-on voltage, is monolithically integrated by planar process with AVE double-implantation method. To ensure a lower breakdown voltage of the avalanche diode for thyristor tum-on than the break-over voltage of the thyristor, $p^+$ wells on thyristor p base layer are made by boron implantation/drive-in for a steeper doping profile with higher concentrations while rest p layers of thyristor and free-wheeling diode parts are formed with Al implantation/drive-in for a doping profile of lower steepness. The free-wheeling diode part is isolated from the thyristor part by formation of separated p-well emitter for suppressing commutation between them, which is achieved during the formation of thyristor p-base layer.

  • PDF

Interconnection of Dispersed Generation Systems considering Load Unbalance and Load Model in Composite Distribution Systems (부하불평형 및 부하모형을 고려한 복합배전계통의 분산형전원의 연계 방안)

  • 이유정;김규호;이상근;유석구
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.53 no.5
    • /
    • pp.266-274
    • /
    • 2004
  • This paper presents a scheme for the interconnection of dispersed generator systems(DGs) based on load .unbalance and load model in composite distribution systems. Groups of each individual load model consist of residential, industrial, commercial, official and agricultural load. The unbalance is involved with many single-phase line segment. . Voltage profile improvement and system loss minimization by installation of DGs depend greatly on how they are placed and operated in the distribution systems. So, DGs can reduce distribution real power losses and replace large-scale generators if they are placed appropriately in the distribution systems. The main idea of solving fuzzy goal programming is to transform the original objective function and constraints into the equivalent multi-objectives functions with fuzzy sets to evaluate their imprecise nature for the criterion of power loss minimization, the number or total capacity of DGs and the bus voltage deviation, and then solve the problem using genetic algorithm. The method proposed is applied to IEEE 13 bus and 34 bus test systems to demonstrate its effectiveness.

High density plasma etching of MgO thin films in $Cl_2$/Ar gases

  • Xiao, Y.B.;Kim, E.H.;Kong, S.M.;Chung, C.W.
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2010.02a
    • /
    • pp.213-213
    • /
    • 2010
  • Magnetic random access memory (MRAM), based on magnetic tunnel junction (MTJ) and CMOS, is one of the best semiconductor memories because it can provide nonvolatility, fast access time, unlimited read/write endurance, low operating voltage and high storage density. For the realization of high density MRAM, the etching of MTJ stack with good properties is one of a key process. Recently, there has been great interest in the MTJ stack using MgO as barrier layer for its huge room temperature MR ratio. The use of MgO barrier layer will undoubtedly accelerate the development of MTJ stack for MRAM. In this study, high-density plasma reactive ion etching of MgO films was investigated in an inductively coupled plasma of $Cl_2$/Ar gas mixes. The etch rate, etch selectivity and etch profile of this magnetic film were examined on vary gas concentration. As the $Cl_2$ gas concentration increased, the etch rate of MgO monotonously decreased and etch slop was slanted. The effective of etch parameters including coil rf power, dc-bais voltage, and gas pressure on the etch profile of MgO thin film was explored, At high coil rf power, high dc-bais voltage, low gas pressure, the etching of MgO displayed better etch profiles. Finally, the clean and vertical etch sidewall of MgO films was achieved using $Cl_2$/Ar plasma at the optimized etch conditions.

  • PDF

Effective Localized-Voltage Control Scheme using the Information from Pilot Bus (Pilot Bus의 정보를 이용한 효율적인 지역별 전압제어)

  • Song, Sung-Hwan;Yoon, Yong-Tae;Moon, Seung-Il;Lee, Ho-Chul
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.55 no.12
    • /
    • pp.505-513
    • /
    • 2006
  • One of the major reasons for recent blackout, like August 14, 2003 blackout in the US and Canada has been insufficient voltage/reactive power support. For the stable reactive power management, a new approach for the voltage monitoring and control structure is required in the market environment. This paper proposes the effective localized-voltage control scheme using the information from pilot buses at each zone. In this paper, the steady state voltage monitoring and control (SSVMC) is adopted and illustrated for the voltage control scheme during steady state because it is thought as the systemic algorithm to explain voltage profile phenomenon before and after contingencies. And the concept of electrical distance is applied to simultaneously achieve both clustering the voltage control zone, and selecting the pilot bus as the representative node at each control zone. Applying SSVMC based on the structure with clustering and pilot bus enables system operators to monitor and understand the system condition much more easily, to monitor and control the voltage in real-time more manageably, and to respond quickly to a disturbance. The proposed voltage control scheme has been tested on the IEEE 14-bus system with the numerical analysis to examine the system reliability and structure efficiency.