Analysis on Electrical Characteristics of Tabbing Cells According to Measurement Methods (측정방식에 따른 Tabbing Cell에서의 전기적 특성 분석)

  • Choi, Eun-Ji;Kim, Kyung-Soo;Kang, Gi-Hwan;Yu, Gwon-Jong;Ahn, Hyung-Keun;Han, Deuk-Young
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.1304-1305
    • /
    • 2011
  • In this study, tabbing cell samples in the soft touch method are compared samples according to soldering voltage conditions. Series resistance and power loss is measured by two measurement method. As a result, probe measurement method was found optimized soldering voltage optimized according to voltage condition and clamp measurement method was not difference. The purpose of this paper is to analysis the principle of measurement method.

  • PDF

Battery State-of-Charge Estimation Algorithm Using Dynamic Terminal Voltage Measurement

  • Lee, Su-Hyeok;Lee, Seong-Won
    • IEIE Transactions on Smart Processing and Computing
    • /
    • v.4 no.2
    • /
    • pp.126-131
    • /
    • 2015
  • When a battery is discharging, the battery's current and terminal voltage must both be measured to estimate its state of charge (SOC). If the SOC can be estimated by using only the current or voltage, hardware costs will decrease. This paper proposes an SOC estimation algorithm that needs to measure only the terminal voltage while a battery is discharging. The battery's SOC can be deduced from its open circuit voltage (OCV) through the relationship between SOC and OCV. But when the battery is discharging, it is not possible to measure the OCV due to the voltage drop in the battery's internal resistance (IRdrop). The proposed algorithm calculates OCV by estimating IRdrop using a dynamic terminal voltage measurement. This paper confirms the results of applying the algorithm in a hardware environment via algorithm binarization. To evaluate the algorithm, a Simulink battery model based on actual values was used.

Precise High Voltage Measurement System Using Ceramic Stack Element for Voltage Divider (분압용 세라믹 적층 소자를 이용하 정밀 고전압 계측 시스템)

  • 윤광희;류주현;박창엽;정영호;하복남
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.13 no.5
    • /
    • pp.396-401
    • /
    • 2000
  • In order to accurately measure the high voltage of 22.9[kV] power distribution lines we investigated the temperature dependence of measuring voltage on the number of stack layers in the voltage measurement system made from single and stack voltage divider capacitors (22, 44, 66 layers, respectively). Temperature coefficient of dielectric constant(TC$\varepsilon_{{\gamma}}$/)of voltage divider capacitors which were fabricated by BaTi $O_3$system ceramics showed the variations from -2.28% to +1.69% in the range of -25[$^{\circ}C$] ~50[$^{\circ}C$]) was decreased with increasing of stack number and the stack element of 66 layers showed the least error of $\pm$0.87%or of $\pm$0.87%.

  • PDF

Partial Discharge Measurement by a Capacitive Voltage Probe in a Gas Insulated Switch (가스절연개폐기에서 용량성 전압프로브를 이용한 부분방전의 측정)

  • Kil, Gyung-Suk;Park, Dae-Won;Choi, Su-Yeon;Kim, Il-Kwon;Park, Chan-Yong
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.21 no.1
    • /
    • pp.85-89
    • /
    • 2008
  • An objective of this paper is to develop a partial discharge (PD) measurement device for monitoring gas insulated switches installed in power distribution system. A capacitive voltage probe was studied and designed to detect PD pulse without an electrical connection. The PD measurement device consists of the capacitive voltage probe attached outside of a bushing, a coupling network which attenuates AC voltage by 270 dB, and a low noise amplifier with the gain of 40 dB in ranges of 500 kHz${\sim}$20 MHz. The sensitivity of the prototype device calculated by a calibrator was 1.98 m V /pc. An application experiment was carried out in a 25.8 kV gas insulated switch and the peak pulse of 76.7 pC was detected. From the experimental results, it is expected that the PD measurement device can be applied to online monitoring system of gas insulated switches.

Parameter Measurement Method for Super Capacitor Failure Diagnosis and Application of Voltage Sag Compensation System Using Super Capacitor (수퍼 커패시터의 고장진단을 위한 파라미터의 측정기법과 순시전압강하 보상장치에의 응용사례)

  • Shon, Jin-Geun
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.8 no.6
    • /
    • pp.173-179
    • /
    • 2009
  • Recently, the super capacitor(EDLC) which has drawn attention as a new energy storage element has a lot of advantage such as no maintenance, long lifetime and quick charge/discharge characteristics with large current. The objective of this paper is propose a parameter measurement method to detect the changes in equivalent series resistor (ESR) and the capacitance value of a super capacitor in order to analysis the internal characteristic and worn-out state of a super capacitor. For proposed method, only the capacitor voltage measurement using simple analog switch is required. In addition, experimental results of voltage sag compensation system in order to compensate the input voltage drop during short-term power interruption adopted super capacitor are presented.

  • PDF

A Study on Accuracy Detection Method for Signal Peak Voltage (신호용 PEAK 전압 정밀검출에 관한 연구)

  • Park, Ho-Chul;Sung, Hyung-Su;Han, Seung-Moon;Han, Jeong-Hoon
    • Proceedings of the KIEE Conference
    • /
    • 2000.07d
    • /
    • pp.2528-2530
    • /
    • 2000
  • In general, Diode makes a major role in electronic circuit. For example, switching of rectifier, cross current of switching rectifier, energy transfer of electronic element and reverse charge of capacitor, voltage insulation, energy feedback from load to power supply, and such as recovery of storaged energy. Generally, We regard power diode as ideal element, but it has a certain boundary actually, specially, We use diode for detecting circuit peak hold voltage signal. It has cut in voltage. It occurs error of measurement value namely. This error, below in region diode voltage drop (0.7v) measurement value is wholesome signal, Specially, We can not get precision data. Therefore, precision level is low between theoretical and measurement data because of error in actual circuit. Conclusionally, In this paper, We define the error concerning to the power diode characteristics which is used detecting of the minute signal, and recommend the method that minimize measurement error.

  • PDF

The Development of Prototype Synchronized Phasor Measurement Device for Real-time Power System Monitoring (전력계통 실시간 감시를 위한 동기위상측정장치의 시작품 개발)

  • 김학만;전진홍;김종율;남기영
    • Journal of Energy Engineering
    • /
    • v.11 no.3
    • /
    • pp.230-236
    • /
    • 2002
  • In real-time power system control, it is essential to measure the power system variables which are voltage, current, real and reactive power, power factor, system frequency and etc. These variables can be estimated or calculated by the synchronized phasor informations of voltage and current. Therefore, the synchronized phasor measurement of voltage and current is very important to real-time power system control. So, we develop SPMD (Synchronized Phasor Measurement Device) for synchronized phasor measurement of voltage and current. In this paper, we present the design and implementation of SPMD for real-time phasor measurement and the test results of developed SPMD on 380 V 3 phase distribution line in laboratory with resistor load and RTDS (Real Time Digital Simulator).

The development of synchronized phasor measurement device for real time power system control (실시간 계통제어를 위한 동기위상측정장치 개발)

  • Jeon, Jin-Hong;Kim, Hak-Man;Chun, Yeong-Han;Kook, Kyung-Soo;Kim, Ji-Won;Oh, Tae-Kyoo
    • Proceedings of the KIEE Conference
    • /
    • 2000.07a
    • /
    • pp.85-87
    • /
    • 2000
  • In real-time power system control, it is essential to measure the power system variables which are voltage. current, real and reactive power, power factor, system frequency and etc. this variables can be estimated or calculated by the synchronized phasor informations of voltage and current. Therefore, the synchronized phasor measurement of voltage and current is very important to real-time power system control. So, we develop SPMD(Synchronized Phasor Measurement Device) for synchronized phasor measurement of voltage and current. In this paper, we present the design and implementation of SPMD for real-time phasor measurement and prove its performance by the test results.

  • PDF

Partial Discharge Detection for the Power Cables using AC and Oscillating wave Voltage (전력케이블에서 교류전압과 진동파 전압을 이용한 부분방전 측정)

  • Kim, Jeong-Tae;Kim, Nam-Jun;Lee, Jeon-Seon;Gu, Ja-Yun
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.48 no.4
    • /
    • pp.247-252
    • /
    • 1999
  • In this paper, in order to investigate availability of the OW-PD measurement method which has been proposed as an alternative of AC-PD measurement method to an after laying test and/or diagnosis for the power cable system, partial discharges owing to the needle-type defect integrated into the cable have been measured using AC and OW(Oscillating Wave) voltages. In the AC-PD measurement, the magnitude, phase and pulse number of partial discharges have been changed with the duration of voltage application, which can be analyzed through the relation with the process of the electrical tree initiation and propagation. In addition, the characteristics of partial discharges using OW voltage are appeared to be similar to those in case of AC-PD measurement and to be different with the shapes of electrical tree. From these results, it is concluded that the OW-PD measurement method is available to the tests for the cable system.

  • PDF

Creepage Distance Measurement Using Binocular Stereo Vision on Hot-line for High Voltage Insulator

  • He, Wenjun;Wang, Jiake;Fu, Yuegang
    • Current Optics and Photonics
    • /
    • v.2 no.4
    • /
    • pp.348-355
    • /
    • 2018
  • How to measure the creepage distance of an insulator quickly and accurately is a problem for the power industry at present, and the noticeable concern is that the high voltage insulation equipment cannot be measured online in the charged state. In view of this situation, we develop an on-line measurement system of creepage distance for high voltage insulators based on binocular stereo vision. We have proposed a method of generating linear structured light using a conical off-axis mirror. The feasibility and effect of two ways to solve the interference problem of strong sunlight have been discussed, one way is to use bandpass filters to enhance the contrast ratio of linear structured light in the images, and the other way is to process the images with adaptive threshold segmentation and feature point extraction. After the system is calibrated, we tested the measurement error of the on-line measurement system with a composite insulator sample. Experimental results show that the maximum relative error is 1.45% and the average relative error is 0.69%, which satisfies the task requirement of not more than 5% of the maximum relative error.