• 제목/요약/키워드: Voltage limit

검색결과 495건 처리시간 0.021초

Reactive Reserve based Contingency Constrained Optimal Power Flow to Enhance Interface Flow Limits in Terms of voltage Stability

  • Hwachang Song;Lee, Byongjun
    • KIEE International Transactions on Power Engineering
    • /
    • 제11A권4호
    • /
    • pp.27-32
    • /
    • 2001
  • This paper presents a concept of reactive reserve based contingency constrained optimal power flow (RCCOPF). RCCOPF for enhancement of interface flow limit is composed of two modules, which are the modified continuation power flow (MCPF) and reactive optimal power flow (ROPF). In RCCOPF, two modules are repeatedly performed to increase interface flow margins of selected contingent states until satisfying the required enhancement of interface flow limit. In numerical simulation, a simple example with New England 39-bus test system is shown.

  • PDF

약계자 영역에서의 유도전동기 과도 토오크 최대화 기법 (Transient Torque Maximizing Strantegy of Induction Machine in Field Weakening Region)

  • 송승호;최종우;설승기
    • 전력전자학회논문지
    • /
    • 제4권5호
    • /
    • pp.474-482
    • /
    • 1999
  • 본 논문에서는 유도전동기의 전 속도 영역에서 출력토오크를 최대화 할 수 있는 새로운 약계자 제어기를 제시하였다. 전압제한과 전류제한을 모두 고려한 약계자 영역에서의 최적해를 구하였다. 제안된 알고리즘은 자속과 속도를 근거로 하여 변동하는 전압 제한 조건을 만족시키는 전류 기준값을 구하게 된다. 따라서 고정자 전압을 최대한 활용하므로 정상상태 뿐만 아니라 전동기의 자속의 크기가 변화하는 과도상태에서도 최대 출력 토오크와 빠른제어 응답성을 얻을 수 있다. 시뮬레이션 및 실험결과를 통해 제안된 약계자 기법의 효용성을 보였다.

  • PDF

Energy Gap of $MgB_2$ from Point Contact Spectroscopy

  • Lee, Suyoun;Yonuk Chong;S. H. Moon;Lee, H. N.;Kim, H. G.
    • Progress in Superconductivity
    • /
    • 제3권2호
    • /
    • pp.146-150
    • /
    • 2002
  • We performed the point contact spectroscopy on newly discovered superconductor $MgB_2$ thin films with Au tip. In the point contact spectroscopy of the metallic Sharvin limit, the differential conductance below the gap is twice as that above the gap by virtue of Andreev Reflection. After some surface cleaning processes of sample preparation such as ion-milling and wet etching, the obtained dI/dV versus voltage curves are relatively well fitted to the Blonder-Tinkham-Klapwijk (BTK) formalism. Gaps determined by this technique were distributed in the range of 3meV~ 8meV with the BCS value of 5.9meV in the weak coupling limit. We attribute these discrepancies to the symmetry of the gap parameter and the degradation of the surface of the sample. We also present the temperature dependence of the conductance vs voltage curve and thereby the temperature dependence of the gap.

  • PDF

Reactive Reserve based Contingency Constrained Optimal Power Flow to Enhance Interface Flow Limits in Terms of Voltage Stability

  • Hwachang Song;Lee, Byongjun
    • KIEE International Transactions on Power Engineering
    • /
    • 제11권X00호
    • /
    • pp.27-32
    • /
    • 2001
  • This paper presents a concept of reactive reserve based contingency constrained optimal power flow (RCCOPF). RCCOPF for enhancement of interface flow limit is composed of two modules, which are the modified continuation power flow (MCPF) and reactive optimal power flow (ROPF). In RCCOPF, two modules are repeatedly performed to increase interface flow margins of selected contingent states until satisfying the required enhancement of interface flow limit. In numerical simulation, a simple example with New England 39-bus test system is shown.

Hybrid Stepping Motor의 Driving Controller 설계와 응용에 관한 연구 (A Study on Applications and Design of Driving Controller Circuit in hybrid Stepping Motor)

  • 최도순
    • 한국산업정보학회논문지
    • /
    • 제6권2호
    • /
    • pp.74-79
    • /
    • 2001
  • 로봇과 자동화기기에 범용으로 사용되는 Stewing Motor의 Driving을 위하여 unipolar 방식과 bipolar 방식의 Controller Circuit를 design 하였으며 특히 design시 Digital logic을 이용하여 Controller를 설계 제작하여 실험을 통해 그 응용성을 실험하였다. 또한 Motor의 효율 향상을 위하여 Motor의 Winding에 흐르는 전류를 제어하기 위하여 constant Current Limit Methode와 Constant Voltage Limit Methode를 분석하고 실재 회로 제작 시 응용하여 Motor의 효율을 향상시켰다.

  • PDF

교류 전기장 인가에 따른 프로판 예혼합 화염의 유동 특성 (Flow Characteristics of Propane Premixed Flame on AC Electric Field)

  • 김보윤;김민석;김태훈;권일송;김혜민
    • 한국분무공학회지
    • /
    • 제29권1호
    • /
    • pp.38-44
    • /
    • 2024
  • This study investigates the flow characteristics of propane-air premixed flames on AC electric field using the Schlieren method. A voltage was applied to the ring electrode and the burner was grounded to form an electric field, and the applied voltage was fixed at 16 kV (Vpp). Results show that under the application of AC electric fields, flow around the flame oscillated only at frequencies below 50 Hz, and no oscillation was observed above this frequency range. Flame height oscillated with frequency in the range of 25 to 300 Hz, with frequency doubling observed in the range of 25 to 150 Hz. The flammability limit increased with frequency up to 250 Hz, but in the high-frequency range above 250 Hz, the flammability limit did not increased and converged.

CVR을 위한 전압 계측 기반 전압 및 무효전력 협조제어 (Voltage Measurement-based coordinated Volt/VAR Control for Conservation Voltage Reduction)

  • 고석일;최준호;안선주;윤상윤
    • 전기학회논문지
    • /
    • 제66권12호
    • /
    • pp.1689-1696
    • /
    • 2017
  • In this paper, the voltage measurement-based coordinated Voltage/VAR control (VMCVVC) algorithm for conservation voltage reduction(CVR) is proposed. The proposed algorithm has the purpose of enhancing the CVR effect through coordinated control of the voltage control devices such as the distributed energy resources and the load tap changer(LTC) transformers. It calculates the references of the voltage control devices such that the bus voltages are maintained at as close to the lower operation limit as possible. For this purpose, firstly, the distribution system is divided into LTC transformer control zones through topological search. Secondly, the reactive power references of the reactive power control devices are determined such that the voltage profile of the section is flattened. Finally, the tap references of the LTC transformers are calculated to lower the voltage profile. The effectiveness of the proposed algorithm is demonstrated through case studies using IEEE test network.

Multimode Hybrid Control Strategy of LLC Resonant Converter in Applications with Wide Input Voltage Range

  • Li, Yan;Zhang, Kun;Yang, Shuaifei
    • Journal of Power Electronics
    • /
    • 제19권1호
    • /
    • pp.201-210
    • /
    • 2019
  • This paper proposes a multimode hybrid control strategy that can achieve zero-voltage switching of primary switches and zero-current switching of secondary rectifier diodes in a wide input voltage range for full-bridge LLC resonant converters. When the input voltage is lower than the rated voltage, the converter operates in Mode 1 through the variable-frequency control strategy. When the input voltage is higher than the rated voltage, the converter operates in Mode 2 through the VF and phase-shift control strategy until the switching frequency reaches the upper limit. Then, the converter operates in Mode 3 through the constant-frequency and phase-shift control strategy. The secondary-side diode current will operate in the discontinuous current mode in Modes 1 and 3, whereas it will operate in the boundary current mode in Mode 2. The current RMS value and conduction loss can be reduced in Mode 2. A detailed theoretical analysis of the operation principle, the voltage gain characteristics, and the realization method is presented in this paper. Finally, a 500 W prototype with 100-200 V input voltage and 40 V output voltage is built to verify the feasibility of the multimode hybrid control strategy.

방전전극 재질과 최소점화에너지에 관한 실험 연구 (An Experimental Study on the Minimum Ignition Energy in Low Voltage Spark Discharge by Electrode Material)

  • 최상원
    • 한국안전학회지
    • /
    • 제27권3호
    • /
    • pp.63-70
    • /
    • 2012
  • In the hazardous areas where explosive gases, vapor or mists exist, electrical apparatus and installations must be the explosion-proof construction to prevent or limit the danger of the ignition of potentially explosive atmosphere. In Korea, nine types of protection have been specified in the government regulations at present: flameproof enclosure, pressurization, oil immersion, increased safety, intrinsic safety, non-incendive, powder filling, encapsulation, and special types. Among these types, the intrinsic safety has the construction which limit or by-pass igniting the electric energy using electronic devices. This type has lots of merits but at the same time requires a high-degree of technology. In this paper, we investigated several dominating factors which affect the minimum ignition energy; this energy plays a very important role in design and evaluation of the intrinsic safety type electrical apparatus. Electrode material, which is one of the most important factors, was intensively studied for the five sorts of material(Al, Cd, Mg, Sn, and Zn) with performing experiment in a low-voltage inductive circuit using IEC-type(International Electro-technical Commission) spark apparatus. The experimental results show that the minimum ignition energy of electrode material is varied: highest in Cd and lowest in Sn. We also confirmed the effect of electrode make-and-break speed.

Effects of Zero-Sequence Transformations and Min-Max Injection on Fault-Tolerant Symmetrical Six-Phase Drives with Single Isolated Neutral

  • Munim, Wan Noraishah Wan Abdul;Tousizadeh, Mahdi;Che, Hang Seng
    • Journal of Power Electronics
    • /
    • 제19권4호
    • /
    • pp.968-979
    • /
    • 2019
  • Recently, there has been increased interest in the study of multiphase machines due to their higher fault-tolerant capability when compared to their conventional three-phase counterparts. For six-phase machines, stator windings configured with a single isolated neutral (1N) provide significantly more post-fault torque/power than two isolated neutrals (2N). Hence, this configuration is preferred in applications where post-fault performance is critical. It is well known that min-max injection has been commonly used for three-phase and multiphase machines in healthy condition to maximize the modulation limit. However, there is a lack of discussion on min-max injection for post-fault condition. Furthermore, the effects in terms of the common-mode voltage (CMV) in modulating signals has not been discussed. This paper investigates the effect of min-max injection in post fault-tolerant control on the voltage and speed limit of a symmetrical six-phase induction machine with single isolated neutral. It is shown that the min-max injection can minimize the amplitude of reference voltage, which maximizes the modulation index and post-fault speed of the machine. This in turn results in a higher post-fault power.