• Title/Summary/Keyword: Voltage drops

Search Result 101, Processing Time 0.024 seconds

Adaptive Reactive Power Control for Communication Errors of Hierarchical Wind Farm Management Systems (중앙집중형 풍력발전단지 제어관리시스템 전용 무효전력제어기 통신오류 보완에 관한 연구)

  • Seungmin Jung
    • Journal of Wind Energy
    • /
    • v.14 no.1
    • /
    • pp.44-51
    • /
    • 2023
  • Some controllers have been introduced in various studies to mitigate the negative effects of renewable sources. These have been modified to fit a formed solution in various ways. This paper deals with the voltage regulation of wind farms in voltage dip situations where communication failures occur. The aim is to discuss the modification of the online wind farm management system. To discuss modifications of the online wind farm management system, we focus on voltage regulation of wind farms when communication failures occur. The structure has been designed to respond to a voltage drop when the outer reference is absent due to communication errors. Since the loss reduction effect has been maintained in the designed case studies, it can be derived that the proposed method can respond to voltage drops, along with a used objective function.

Breakdown characteristics of SF6 and Imitation Air in Temperature Decline

  • Lim, Chang-Ho;Choi, Eun-Hyeok;Kim, Do-Seok;Kim, Young-Su;Park, Won-Zoo;Lee, Kwang-Sik
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.21 no.4
    • /
    • pp.115-121
    • /
    • 2007
  • This paper describes experiments of the breakdown characteristics by temperature change of $SF_6$ gas and Imitation Air(I-Air) in model GIS(Gas Insulated Switchgear). From the results of the experiments, the breakdown characteristics classify the vapor stage of $SF_6$ according to Paschen's law, in which the stage of coexistence for gas & liquid of the voltage value increases. This results in large deviation and the breakdown of the voltage(VB) low stage as the interior of the chamber is filled with a mixture of $SF_6$ that is not liquefacted and remaining air that can not be ventilated. The ability of $SF_6$ liquid($LSF_6$) insulation is higher than high-pressurize $SF_6$ gas. The VB of the I-Air decreases as the temperature drops and the VB also drops. It is considered that the results of this paper are fundamental data for the electric insulation design of superconductor and cryogenic equipment that will be studied and developed in the future.

The Digital Controller of the Single-Phas Power Factor Correction(PFC) having the Variable Gain (가변 이득을 가지는 단상 PFC 디지털 제어기)

  • 정창용
    • Proceedings of the KIPE Conference
    • /
    • 2000.07a
    • /
    • pp.163-167
    • /
    • 2000
  • This paper presents the digital control of single-phase power factor correction(PFC) converter which has the variable gain according to the condition of inner control loop error. Generally the gain of inner current control loop in single-stage PFC converter has a constant magnitude. This has a bad influence on the power factor because current loop doesn't operate smoothly in the condition that input voltage is low In particular a digital controller has more time delay than an analog controller and degrades This drops the phase margin of the total digital PFC system,. It causes the problem that the gain of current control loop isn't increased enough. In addition the oscillation happens in the peak value of the input voltage open loop PFC system gain changes according to ac input voltage. These aspects make the design of the digital PFC controller difficult The digital PFC controller presented in this paper has a variable gain of current control loop according to input voltage. The 1kW converter was used to verify the efficiency of the digital PFC controller.

  • PDF

LLC Resonant Converter with Hold-up Time Extension Technique for Computer Power Supply

  • Choi, Seong-Wook;Moon, Gun-Woo
    • Proceedings of the KIPE Conference
    • /
    • 2008.06a
    • /
    • pp.228-230
    • /
    • 2008
  • A LLC resonant converter with hold-up time extension technique for computer power supply is proposed. Since the proposed circuit has a current boost-up capability of resonant inductor regardless of the input voltage level and the load power condition, operating near the resonant frequency, it can provide the power to the load as the input voltage drops to half of reflected output voltage to the transformer primary. This extends the hold-up time of computer power supply and improves the system power density and conversion efficiency at nominal input voltage. The experimental results with prototype are given to confirm the validity of the proposed circuit.

  • PDF

Experimental study on CIS thin film deposition via electrostatic spray technique (정전기 스프레이 기술을 이용한 CIS 박막코팅에 관한 실험적 연구)

  • Yoon, Hyun;Yoon, Sukgoo;Kim, Hoyoung
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2010.11a
    • /
    • pp.37.2-37.2
    • /
    • 2010
  • Electrostatic spray deposition is an innovative coating technique that produces fine, uniform, self-dispersive (due to the Coulombic repulsion), and highly wettable, atomized drops. Copper-indium salts are dissolved in an alcohol-based solvent, which is then electrostatically sprayed onto a moderately heated, molybdenum-coated substrate. Solvent flowrates range from 0.02 to 5 ml/hr under applied voltages of 1 to 20 kV yielding drop sizes around a few hundred nanometers. By comparing the scanning electron miscrscope images of coated samples, the substrate temperature, applied voltage, solvent flowrate, and nozzle-substrate distance are demonstrated to be the primary parameters controlling coating quality. Also, the most stable electrostatic spray mode that reliably produces uniform and fine drops is the cone-jet mode with a Taylor cone issuing from the nozzle.

  • PDF

The study on controling curie temperature for the temperature-sensitive Magnetic materical at colling method. (냉각방법에 의한 감온자성체의 큐리온도 조정에 관한 연구)

  • Bae, Jin-Ho;Sin, Yong-Cheol;Kim, Han-Geun
    • Proceedings of the KIEE Conference
    • /
    • 1988.07a
    • /
    • pp.828-830
    • /
    • 1988
  • This paper considered temperature-sensitive characteristics on the basis of curie tempeature and quenching method in the process of manufacturing Mn-Cu-Zn Fersite. The results are as follow. Curie tempeature drops according as the content of CuO and ZnO increases. It also decreases according as sintering temperature increases when the content of ZnO in fixed. Curie temperature drops more in quenching than in slow cooling and activation energy diminishes were too. On the basis of curie tempeature, activation energy is greater in paramagnetic region than in ferrimagnetic region. As its voltage-crrent characteristics is similar to that semiconductors, the temperature-sensitive ferrite is expeated to be appied in the area of power electronics.

  • PDF

A Single-Input Single-Output Approach by using Minor-Loop Voltage Feedback Compensation with Modified SPWM Technique for Three-Phase AC-DC Buck Converter

  • Alias, Azrita;Rahim, Nasrudin Abd.;Hussain, Mohamed Azlan
    • Journal of Power Electronics
    • /
    • v.13 no.5
    • /
    • pp.829-840
    • /
    • 2013
  • The modified sinusoidal pulse-width modulation (SPWM) is one of the PWM techniques used in three-phase AC-DC buck converters. The modified SPWM works without the current sensor (the converter is current sensorless), improves production of sinusoidal AC current, enables obtainment of near-unity power factor, and controls output voltage through modulation gain (ranging from 0 to 1). The main problem of the modified SPWM is the huge starting current and voltage (during transient) that results from a large step change from the reference voltage. When the load changes, the output voltage significantly drops (through switching losses and non-ideal converter elements). The single-input single-output (SISO) approach with minor-loop voltage feedback controller presented here overcomes this problem. This approach is created on a theoretical linear model and verified by discrete-model simulation on MATLAB/Simulink. The capability and effectiveness of the SISO approach in compensating start-up current/voltage and in achieving zero steady-state error were tested for transient cases with step-changed load and step-changed reference voltage for linear and non-linear loads. Tests were done to analyze the transient performance against various controller gains. An experiment prototype was also developed for verification.

A Study on the Tolerance Band of Voltage Drop during Motor Startup for Refineries and Chemical Plants with Isolated Power Systems

  • Shin, Ho-Jeon;Cho, Man-Young;Chun, Hong-Il;Kim, Jin-Seok
    • Journal of Electrical Engineering and Technology
    • /
    • v.12 no.1
    • /
    • pp.486-493
    • /
    • 2017
  • Refineries and chemical plants with isolated power systems that have a limited power supply are more susceptible to voltage changes from disturbances compared to power systems connected with a power company. Furthermore, most loads in such cases are induction motor loads, and therefore, transient voltage characteristics when starting a high-capacity motor must be examined. In general, high-capacity motors are customized appropriately to the load performance curve by the manufacturer during the construction of an industrial plant. Subsequently, when complying with the voltage drop permitted by international standards during the design process, power supply equipment such as transformers and generators is overdesigned. Therefore, a novel analysis is necessary on standards for startup and constraint voltage drops, as well as on identifying the voltage drop limitations for starting high-capacity motors in refineries and chemical plants with isolated power systems. In this study, field tests on an industrial plant were conducted, and simulations modeled under conditions identical to those of the field test system were performed using the general-purpose program ETAP in order to compare the results.

A study on the effects of a conducting metallic barrier on the surface creepage flash over discharge (연면방전에 미치는 도전층의 영향에 관한 연구)

  • Sung Kae Chung
    • 전기의세계
    • /
    • v.17 no.3
    • /
    • pp.7-28
    • /
    • 1968
  • When a insulator plate is inserted to the discharge path of a space discharge gap in which the field strength is not uniform, the spark voltage under the atmospheric pressure between the electrodes decreases or rises according to the position of the insulating plate. Also it is reported that if a metallic barrier plate is inserted to the discharge path of the same space discharge gap, similar variations of spark voltage are found. Speaking briefly, mensioned above are the spark voltage characteristics when an insulator or metallic barrier is inserted to the space discharge gap. Also some experimental results, concerning to the surface creepage flash over characteristics at the case when an insulator barrier is inserted to the discharge path of a surface creepage discharge gap, were reported by Peek. But up to now there are no reports on surface flash over voltage characteristics at the case when a metallic barrier is inserted to the surface creepage gap. In this study the effects of a conducting metallic barrier inserted to the path of a surface creepage discharge gap on the flash over voltage characteristics are investigated theoretically and experimentally, and got some important results, clearing the effects of the position and width of a conducting barrier is inserted, the surface flash over voltage characteristics appear as an Inverse N or W Characteristics. Such theoretical or experimental results may have some relation not only with the effects of dry belt and snow on suspension insulators, but also with the effects of dirty zone or water drops on the surface creepage flash over voltage.

  • PDF

Study on Transformer Saturation in Isolated Full-Bridge DC-DC Converters (절연형 풀브리지 DC-DC 컨버터에서의 변압기 포화에 관한 연구)

  • Kim, Jeonghun;Cha, Honnyong
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.25 no.4
    • /
    • pp.261-268
    • /
    • 2020
  • Transformer saturation in full bridge (FB) isolated DC-DC converters is caused by uneven switching speeds and voltage drops in semiconductor devices and mismatched gate signals. In order to prevent transformer saturation, most popular and widely used approach is to insert a capacitor in series with the transformer windings. This study conducts extensive analyses on transformer saturation and the effect of DC blocking capacitors when they are placed in the primary or secondary windings of a transformer. The effect of the DC blocking capacitors is verified in voltage-fed and current-fed FB converters.