• 제목/요약/키워드: Voltage and frequency control

검색결과 1,508건 처리시간 0.029초

A New Control Scheme of Class-E Electronic Ballast with Low Crest Factor

  • Chon, Hyun-Son;Lee, Dong-Yun;Hyun, Dong-Seok
    • Journal of Power Electronics
    • /
    • 제3권3호
    • /
    • pp.175-184
    • /
    • 2003
  • In this paper, a new control scheme of Class-E inverter for reducing the crest factor of electronic ballasts for fluorescent lamps using Pulse-Frequency-Modulation (PFM) is Introduced The lifetime of the lamps is guaranteed by decreasing the lamp crest factor and also voltage stress of the switch is significantly decreased by a new scheme although conventional Class-E Inverter is used In this paper. The proposed PFM control scheme didn't use any auxiliary circuit. The proposed control strategy is executed by feeding back the Input voltage, and the zero-voltage-switching (ZVS) is ensured by maintaining constant turn-off time of the switch Therefore, the control principles of proposed method are explained in detail and its validity is verified through several simulations and experimental results.

A New Control Scheme for a Class-D Inverter with Induction Heating Jar Application by Constant Switching Frequency

  • Choi Won-Suk;Park Nam-Ju;Lee Dong-Yun;Hyun Dong-Seok
    • Journal of Power Electronics
    • /
    • 제5권4호
    • /
    • pp.272-281
    • /
    • 2005
  • In this paper, a simple power control scheme for a constant frequency Class-D inverter with a variable duty cycle is proposed. It is more suitable and acceptable for high- frequency induction heating (IH) jar applications. The proposed control scheme has the advantages of not only wide power regulation range but also ease of control output power. Also it can achieve a stable and efficient Zero-Voltage-Switching (ZVS) in a whole load range. The control principles of the proposed method are described in detail and its validity is verified through simulated and experimental results on 42.8kHz IGBT for induction heating rated on 1.6kW with constant frequency variable power.

에어컨 인버터의 3차원 Vector제어 (Three dimensional vector control of airconditioner inverter)

  • 장재석;이장명
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1997년도 한국자동제어학술회의논문집; 한국전력공사 서울연수원; 17-18 Oct. 1997
    • /
    • pp.500-503
    • /
    • 1997
  • In this paper, we investigate the control methodology of inverter Airconditioner, using the three dimensional vector scheme. The method of three dimensional vector aims at the determination of optimal switching patterns for PWM to reduce switching loss and to improve the performance supplied voltage. The induction motors are widely used for home Airconditioners. These motors can be classified into two types: on or off control of Airconditioner and the speed control of motor. For speed control of motors, generally PWM methods are used. The PWM method based upon the modulation of triangular wave can not afford to supply line voltage to the motor sufficiently because of the capacity of processing speed of micro processors. Therefore airconditioner can not be operated efficiently. This problem can be solved with the method of three dimensional vector since it can increase the supplied voltage and maximum operating frequency of motor to 173V and 96Hz, respectively. As the result, this method shows 10 - 15% increase of voltage and 10% increase of operating frequency over the modulation of triangular wave. According to a theoretical study, the number of switching in the method of three dimensional vector is smaller than that of the modulation of triangular wave. The power consumption can be reduced and the supplied voltage can be increased. In other words, the efficiency of Airconditioner can be improved. We show that the method of three dimensional vector can supply higher voltage than the modulation of triangular method through the experiments and verify the degree of improvement of efficiency theoretically.

  • PDF

PLL을 이용한 무선 전력전송 장치의 공진 주파수의 계측 및 주파수 제어 (Measurement and Control of the Resonance Frequency for the Transcutaneous Energy Transmission System (TET) Using the Phase Locked Loop Circuit (PLL))

  • 최성욱;심은보
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2008년도 추계학술대회A
    • /
    • pp.1613-1616
    • /
    • 2008
  • A Transcutaneous Energy Transmission System (TET) has been developed for the wireless energy transmission with two magnetically coupled coils. A resonance circuit is used to raise the induced voltage and current of the secondary coil. Its resonance frequency depends on the internal resistance of circuit and the transferred energy. Because the transferred energy usually changes in wide range, the output voltage is unstable and the energy transferring efficiency decrease. A push-pull class E amplifier is usedto generate high frequency AC voltage. To maintain proper resonance frequency, the voltage output of the amplifier was continuously monitored and adjusted to the optimized resonance frequency. Because of its high frequency (370 kHz), a phase lockedloop circuit and a comparator are used to monitor the output waveform. The results of experimentaldata show that the PLL circuit can increase the transmission efficiency and stabilize the output voltage of TET.

  • PDF

PC기반 치과 CT용 고전압 펄스 발생장치 개발 (Development of PC based High Voltage Generator for Dental CT)

  • 김학성;오준용;송상훈;원충연
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2008년도 하계학술대회 논문집
    • /
    • pp.580-582
    • /
    • 2008
  • The object of this paper is develope the PC based controlled high voltage power supply and studies 1.2kW(120kV, 10mA) pulse power X-ray generator possible to adapt fluoroscopy of Dental CT X-ray generator and industrial X-ray pulse power equipment. The developed pulse power X-ray generator consisted of mono-block tank include X-ray tube and high voltage X-ray power supply circuit and high voltage control unit with RS232C/422 communication port. The PC control program of pulse power X-ray generator uses LabVIEW, and the size of high voltage transformer and high voltage generator is minimized by high voltage high frequency inverter has 100kHz switching frequency. Also this paper shows result of X-ray tube voltage and tube current correspond to variable load.

  • PDF

Three Phase Voltage Source Soft Switching Inverter with High Frequency Pulse Current Transformers

  • Inaba, Claudio Y.;Hiraki, Eiji;Nakaoka, Mutsuo
    • Journal of Power Electronics
    • /
    • 제2권4호
    • /
    • pp.288-296
    • /
    • 2002
  • In this paper, a high frequency transformer - assisted auxiliary active resonant commutated snubber (HFTA-ARCS) for voltage source soft switching pulse width modulated power conversion circuits is presented. A three phase voltage source type soft switching inverter incorporating HFTA-ARCS circuits in its three bridge legs can reduce current rating of auxiliary active power switches and has sensorless simplified control scheme which any specified boost current management is not required for soft switching. Its operation principle and digital control scheme are described and a practical design method of circuit parameters on this HFTA-ARCS circuit is also introduced on the basis of computer simulation. Moreover, this space voltage vector modulated soft switching inverter system with DSP-based digital control scheme Is discussed and its effectiveness is proved on the basis of performance evaluations. The operating performances of this inverter system are also compared with those of conventional three-phase hard switching inverter under practical conditions of specified parameters.

Analysis of Multi-Agent-Based Adaptive Droop-Controlled AC Microgrids with PSCAD: Modeling and Simulation

  • Li, Zhongwen;Zang, Chuanzhi;Zeng, Peng;Yu, Haibin;Li, Hepeng;Li, Shuhui
    • Journal of Power Electronics
    • /
    • 제15권2호
    • /
    • pp.455-468
    • /
    • 2015
  • A microgrid (MG) with integrated renewable energy resources can benefit both utility companies and customers. As a result, they are attracting a great deal of attention. The control of a MG is very important for the stable operation of a MG. The droop-control method is popular since it avoids circulating currents among the converters without using any critical communication between them. Traditional droop control methods have the drawback of an inherent trade-off between power sharing and voltage and frequency regulation. An adaptive droop control method is proposed, which can operate in both the island mode and the grid-connected mode. It can also ensure smooth switching between these two modes. Furthermore, the voltage and frequency of a MG can be restored by using the proposed droop controller. Meanwhile, the active power can be dispatched appropriately in both operating modes based on the capacity or running cost of the Distributed Generators (DGs). The global information (such as the average voltage and output active power of the MG and so on) required by the proposed droop control method to restore the voltage and frequency deviations can be acquired distributedly based on the Multi Agent System (MAS). Simulation studies in PSCAD demonstrate the effectiveness of the proposed control method.

회전자 여자제어를 이용한 풍력발전 DFIG의 출력제어 (Power Control of the DFIG Using the Rotor Exciting Control)

  • 이우석;오철수
    • 조명전기설비학회논문지
    • /
    • 제13권3호
    • /
    • pp.93-100
    • /
    • 1999
  • 풍력발전은 넓은 범위의 속도제어를 요구하며, 권선형 유도발전기를 이용한 DFIG시스템을 이러한목적에 잘 부합한다. 동기속도 이상의 영역에서 풍속에 의한 원동기 속도와 증가에 불구하고 회전자 여자 주파수를 슬립주파수와 다르게 인가하여 DFIG의 속도와 출력 제얼르 다루고 있다. 속도제어와 동작점 이동의 해석을 위하여 토크시뮬레이션을 하였고, 회전자 여자주파수와 전압제어에 의해 출력이 정격값 이하의 안정된 영역에서 제어될 수 있음을 고찰하였다.

  • PDF

Sliding Mode Control of a New Wind-Based Isolated Three-Phase Induction Generator System with Constant Frequency and Adjustable Output Voltage

  • Moradian, Mohammadreza;Soltani, Jafar
    • Journal of Power Electronics
    • /
    • 제16권2호
    • /
    • pp.675-684
    • /
    • 2016
  • This paper presents a new stand-alone wind-based induction generator system with constant frequency and adjustable output voltage. The proposed generator consists of a six-phase cage-rotor induction machine with two separate three-phase balanced stator windings and a three-phase space vector pulse width modulation inverter that operates as a static synchronous compensator (STATCOM). The first stator winding is fed by the STATCOM and used to excite the machine while the second stator winding is connected to the generator external load. The main frequency of the STATCOM is determined to be constant and equal to the load-requested frequency. The generator output frequency is independent of the load power demand and its prime mover speed because the frequency of the induced emf in the second stator winding is the same as this constant frequency. A sliding mode control (SMC) is developed to regulate the generator output voltage. A second SMC is used to force the zero active power exchanged between the machine and the STATCOM. Some simulation and experimental results are presented to prove the validity and effectiveness of the proposed generator system.

A Controllable LCL-T Resonant AC/DC Converter for High Frequency Power Distribution Systems

  • Zeng, Jun;Li, Xuesheng;Liu, Junfeng
    • Journal of Power Electronics
    • /
    • 제15권4호
    • /
    • pp.876-885
    • /
    • 2015
  • High frequency alternating current (HFAC) has been widely used in a wide range of power distribution systems (PDS) due to its superior performance. A high frequency AC/DC converter plays the role of converting HFAC voltage to DC voltage. In this paper, a new LCL-T resonant AC/DC converter has been proposed, and an easier control method based on input voltage comparison is presented, without the complicated calculation of the zero-crossing point. Both a low distortion and near-to-unity power factor can be achieved by the proposed resonant converter and control strategy. The operational principle and steady-state analysis are given for the proposed resonant converter. A simulation model and experimental prototype are implemented with an operation frequency of 25kHz and a rated power of 20W. The simulation and experimental results verify the accuracy of the analysis and the excellent performance of the proposed topology.