• 제목/요약/키워드: Voltage Sensitivity

Search Result 651, Processing Time 0.025 seconds

A Study on the Effective Enhancement of the Load Power Factor Using the Load Power Factor Sensitivity of Generation Cost and Integrated Costs (발전비용의 부하역률 감도와 종합비용을 활용한 효과적인 역률개선 방안 연구)

  • Lee, B.H.;Oh, M.H.;Kim, J.H.;Shim, K.B.
    • Proceedings of the KIEE Conference
    • /
    • 2003.11a
    • /
    • pp.284-286
    • /
    • 2003
  • The low load power factor causes various problems such as the Increase of the power loss and the voltage instability. The demand of reactive power increases continuously with the growth of active power and the restructuring of electric power companies makes the integrated management of ractive power troublesome, from which the systematic control of load power factor is required. In this paper, the load power factor sensitivity of the generation cost and integrated costs are used for determining the locations and capacities of reactive power compensation devices effectively and for enhancing the load power factor appropriately. It is shown through the application to a small-scale power system that the system power factor can be enhanced effectively and appropriately using the load power factor sensitivity and integrated costs.

  • PDF

A Study on Enhancing the Load Power Factor from the Point of View of Economic Operation Using the Load Power Factor Sensitivity Method (부하역률 감도기법 적용에 의한 전력시스템의 경제운용 측면에서의 역률개선 방안 연구)

  • Lee B. H.;Kim J. H.
    • Proceedings of the KIEE Conference
    • /
    • summer
    • /
    • pp.153-155
    • /
    • 2004
  • Various problems such as the increase of the power loss and the voltage instability may often occur in the case of low load power factor. The demand of reactive power increases continuously with the growth of active power and the restructuring of electric power companies makes the integrated management of ractive power a troublesome problem, so that the systematic control of load power factor is required. In this paper, the load power factor sensitivity of the generation cost is used for determining the locations of reactive power compensation devices effectively and for enhancing the load power factor appropriately. In addition, the integrated costs are used for determining the value of the load power factor from the point of view of the economic operation. It is shown through the application to a large-scale power system that the system power factor can be enhanced effectively and appropriately using the load power factor sensitivity and integrated costs.

  • PDF

Analysis of Sildenafil and its Analogues by LC/MS/MS (LC/MS/MS를 이용한 sildenafil 및 그 유사체 분석)

  • Myung, Seung-Woon;Park, So-Hee;Cho, Hyun-Woo
    • Analytical Science and Technology
    • /
    • v.16 no.6
    • /
    • pp.488-498
    • /
    • 2003
  • By LC/MS/MS, the analytical method of sildenafil and its analogues (homosildenafil, vardenafil and tadalafil) used as used medical treatment of impotence was established. electrosprary ionization (ESI) and atmospheric pressure chemical ionization (APCI) as a ionization method were applied. Several parameter were varied and the sensitivity and reproducibility were compared. In LC/ESI-MS method, capillary voltage, cone voltage, extractor, entrance and RF lens to create appropriate productr ions for multiple reaction monitoring (MRM) were variable parameter, but the formation of the other product ions except the precursor ion could not detect. And the value of entrance, collision energy, exit, corona voltage, cone voltage, extractor, RF lens, cone gas, and desolvation gas in APCI mode were varied, only the creation pattern of fragment ions by the change of RF lens value were detected, and the limit of detection was decreased due to the increase of S/N. Ten millimole ammonium formate (pH 4.8):acetonitrile=70:30 by isocratic elution in HPLC system was shown the maximum sensitivity in MS, the detection limit of sildenafil, homosildenafil, vardenafil and tadalafil obtained by ESI-MRM were 0.10, 0.025, 0.025, and $0.25{\mu}g/mL$ at S/N>5, respectively.

The Analysis of the Breakdown Voltage according to the Change of JTE Structures and Design Parameters of 4H-SiC Devices (4H-SiC 소자의 JTE 구조 및 설계 조건 변화에 따른 항복전압 분석)

  • Koo, Yoon-Mo;Cho, Doo-Hyung;Kim, Kwang-Soo
    • Journal of IKEEE
    • /
    • v.19 no.4
    • /
    • pp.491-499
    • /
    • 2015
  • Silicon Carbide(SiC) has large advantage in high temperature and high voltage applications because of its high thermal conductivity and large band gap energy. When using SiC to design power semiconductor devices, edge termination techniques have to be adjusted for its maximum breakdown voltage characteristics. Many edge termination techniques have been proposed, and the most appropriate technique for SiC device is Junction Termination Extension(JTE). In this paper, the change of breakdown voltage efficiency ratio according to the change of doping concentration and passivation oxide charge of each JTE techniques is demonstrated. As a result, the maximum breakdown voltage ratio of Single Zone JTE(SZ-JTE), Double Zone JTE(DZ-JTE), Multiple Floating Zone JTE(MFZ-JTE), and Space Modulated JTE(SM-JTE) is 98.24%, 99.02%, 98.98%, 99.22% each. MFZ-JTE has the smallest and SZ-JTE has the largest sensitivity of breakdown voltage ratios according to the change of JTE doping concentration. Additionally the degradation of breakdown voltage due to the passivation oxide charge is analyzed, and the sensitivity is largest in SZ-JTE and smallest in MFZ-JTE, too. In this paper, DZ-JTE and SM-JTE is the best efficiency JTE techniques than MFZ-JTE which needs large doping concentration in short JTE width.

Design and Fabrication of Silicon Flow Sensor For Detecting Air Flow (유속 감지를 위한 실리콘 유량센서의 설계 및 제작)

  • 이영주;전국진;부종욱;김성태
    • Journal of the Korean Institute of Telematics and Electronics A
    • /
    • v.31A no.5
    • /
    • pp.113-120
    • /
    • 1994
  • Silicon flow sensor that can detect the velocity and direction of air flow was designed and fabricated by integrated circuit process and bulk micromachining technique. The flow sensor consists of three-layered dielectric diaphragm, a heater at the center of the diaphragm, and four thermopiles surrounding the heater at each side of diaphragm as sensing elements. This diaphragm structure contributes to improve the sensitivity of the sensor due to excellent thermal isolation property of dielectric materials and their tiny thickness. The flow sensor has good axial symmetry to sense 2-D air flow with the optimized sensing position in the proposed structure. The sensor is fabricated using CMOS compatible process followed by the anisotropic etching of silicon in KOH and EDP solutions to form I$\mu$ m thick dielectric diaphragm as the last step. TCR(Temperature Coefficient of Resistance) of the heater of the fabricated sensors was measured to calculate the operating temperature of the heater and the output voltage of the sensor with respect to flow velocity was also measured. The TCR of the polysilicon heater resistor is 697ppm/K, and the operating temperature of the heater is 331$^{\circ}C$ when the applied voltage is 5V. Measured sensitivity of the sensor is 18.7mV/(m/s)$^{1/2}$ for the flow velocity of smaller than 10m/s.

  • PDF

Magnetic Sensor Using Giant Magneto-Impedance Effect (거대자기임피던스 효과를 이용한 자기 센서)

  • Choi, Kyoo-Nam
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.12 no.6
    • /
    • pp.1057-1064
    • /
    • 2017
  • High sensitivity magnetic sensor having foreign metal detection capability is proposed utilizing giant magneto-impedance effect. Strip sensor showed the increasing output voltage when the external magnetic field was applied along with strip from strip grounding point, although the initial DC voltage varied depending on the pointing direction of strip sensor. Proposed sensor was able to eliminate more than half of background noise using active noise filter to achive high sensitivity, and it showed the capability to detect magnetized foreign metal object independent of ambient electro-magnetic noise and earth magnet. In case of ferrous sphere, the metal detection up to 0.8mm diameter was experimentally demonstrated at 5mm distance from strip sensor.

Optimization of 1-3 Piezoelectric Composites Considering Transmitting and Receiving Sensitivity of Underwater Acoustic Transducers (수중 음향 트랜스듀서의 송수신 감도를 고려한 1-3형 압전복합체의 구조 최적화)

  • Lee, Jaeyoung;Pyo, Seonghun;Roh, Yongrae
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.26 no.11
    • /
    • pp.790-800
    • /
    • 2013
  • The optimal structure of 1-3 piezocomposites has been determined by controlling polymer properties, ceramic volume fraction, thickness of composite and aspect ratio of the composite to maximize the TVR (transmitting voltage response), RVS (receiving voltage sensitivity) and FBW (fractional bandwidth) of underwater acoustic transducers. Influence of the design variables on the transducer performance was analyzed with equivalent circuits and the finite element method. When the piezocomposite is vibrating in a pure thickness mode, inter-pillar resonant modes are likely to occur between lattice-structured piezoceramic pillars and polymer matrix, which significantly deteriorate the performance of the piezocomposite. In this work, a new method to design the structure of the 1~3 type piezocomposite was proposed to maximize the TVR, RVS and FBW while preventing the occurrence of the inter-pillar modes. Genetic algorithm was used in the optimal design.

An Unbalanced A.C. Bridge with High Voltage Source for the Conductometric Determination of Sulfur in Iron Ores (일정전류 비평행교류브릿지에 의한 전도도측정과 황의 정량)

  • Czae, Myung-Zoon;Choe, Gyu-Won
    • Journal of the Korean Chemical Society
    • /
    • v.14 no.4
    • /
    • pp.327-332
    • /
    • 1970
  • A simple and convenient device for deflection-type direct reading the variations in electrolytic conductance is described and applied to the analysis of sulfur by combustion-$H_2O_2$ oxidation method. The apparatus consisted of a high resistance-ratio bridge in which the other adjacent arms are the differential cells. By adopting unusually high a-c voltage source for the bridge excitation, the a-c method for unbalanced bridge is established, decreased sensitivity owing to reduced bridge factor, 0.01, is overcome and also the absolute sensitivity and linearity are greatly improved. Over 50% variations in impedance of the balanced cell, within 1% deviation from the linearity can be attained with a volt (rms)order of output which was detected directly with VTVM without further amplification. Analysis of the bridge shows that these useful features are natural result of the constant current character of the high source impedance generator and the performance of the device agreed with the theoretical predictions. A standard procedure for the rapid analysis of sulfur using the bridge is also given, the analytical accuracy was approximately 1%. A determination takes not more than 5 minutes.

  • PDF

DC Current Transducer Using Saturable Magnetic Cores (포화자성코어를 이용한 직류전류측정 트랜스듀서)

  • Park, Young-Tae;Jung, Jae-Kap;Gang, Jeon-Hong;Ryu, Kwon-Sang;Yu, Kwang-Min
    • Journal of the Korean Magnetics Society
    • /
    • v.14 no.4
    • /
    • pp.138-142
    • /
    • 2004
  • Uncertainty and characteristics of the developed current sensor by means of two identically wound magnetic cores forming a ring like for measurement of a low DC current such as leakage current was described in this paper. This transducer consists of a sensor type of a current transformer, peak value detectors, a reference alternating low frequency voltage oscillator, precision measuring circuits to measure the output signals of sensor with harmonics, and can be measured up to 2 A at DC current. The resolution and sensitivity of the sensor were 0.1㎃ and 10㎷/㎃, respectively.

A Study on Pattern Analysis of Odorous Substances with a Single Gas Sensor

  • Kim, Han-Soo;Choi, Il-Hwan;Kim, Sun-Tae
    • Journal of Sensor Science and Technology
    • /
    • v.25 no.6
    • /
    • pp.423-430
    • /
    • 2016
  • This study used a single metal oxide semiconductor (MOS) sensor to classify the major odorous gases hydrogen sulfide ($H_2S$), ammonia ($NH_3$) and toluene ($C_6H_5CH_3$). In order to classify these odorous substances, the voltage on the MOS sensor heater was gradually reduced in 0.5 V steps 5.0 V to examine the changes to the response by the cooling effect on the sensor as the voltage decreased. The hydrogen sulfide gas showed the highest sensitivity compared to odorless air under approximately 2.5 V and the ammonia and toluene gases showed the highest sensitivity under approximately 5.0 V. In other words, the hydrogen sulfide gas reacted better in the low temperature range of the MOS sensor, and the ammonia and toluene gases reacted better in the high-temperature range. In order to analyze the response characteristics of the MOS sensor by temperature in a pattern, a two-dimensional (2D) x-y pattern analysis was introduced to clearly classify the hydrogen sulfide, ammonia, and toluene gases. The hydrogen sulfide gas was identified by a straight line with a slope of 1.73, whereas the ammonia gas had a slope of 0.05 and the toluene gas had a slope of 0.52. Therefore, the 2D x-y pattern analysis is suggested as a new way to classify these odorous substances.