• Title/Summary/Keyword: Voltage Gradient

검색결과 139건 처리시간 0.027초

핵비등에서 기포의 동특성에 대한 전기장의 효과 (Effects of an Electric Field on the Dynamic Characteristics of Bubbles in Nucleate Boiling)

  • 권영철;장근선;권정태;김무환
    • 설비공학논문집
    • /
    • 제12권11호
    • /
    • pp.963-971
    • /
    • 2000
  • In order to investigate the effects of an electric field on EHD(Electro-hydrodynamic) nucleate boiling hat transfer characteristics in a nonuniform electric field under saturated pool boiling, the basic study has been performed experimentally. In the present study, the working fluid is R-113 and the plate-wire electrode system is used to generate a steep electric field gradient. Boiling parameters are investigated by using a high speed camera. The electric field distribution around a wire is obtained to understand the effect of an electric field on bubble departure/movement. The experimental results show EHD effects are much more considerable when the applied voltage increases. Bubbles depart away from the heated wire in radial direction. It is confirmed that the mechanisms of EHD nucleate boiling are closely connected with the dynamic behavior of bubbles. The boiling parameters are significantly changed by the electric field strength. With increasing applied voltages, the bubble size decreases and the nucleation site density, bubble velocity and bubble frequency increase.

  • PDF

분산전원이 연계된 배전계통의 최적 전압/무효전력 제어 알고리즘 (The Optimal Volt/Var Control Algorithm with Distributed Generation of Distribution System)

  • 김영인;임일형;최면송;이승재;이성우;하복남
    • 전기학회논문지
    • /
    • 제59권2호
    • /
    • pp.298-305
    • /
    • 2010
  • In this paper, a new algorithm of optimal Volt/Var Control is proposed using Volt/Var control for the Distribution Automation System (DAS) with Distributed Generation (DG) based on the modeling of the distributed load and the distributed current. In the proposed, algorithm based on the modeling of the distributed load and the distributed current are estimated from constants of four terminals using the measurement of the current and power factor from a Feeder Remote Terminal Unit (FRTU) and DG data from RTU for DG. For the optimal Volt/Var Control, the gradient method is applied to find optimal solution for tap, capacity and power control of OLTC (On-Load Tap Changers), SVR (Step Voltage Regulator), PC (Power Condenser) and DG (Distributed Generation). In the case studies, the estimation and control of the voltages have been testified in a radial distribution system with DG using matlab program.

플라즈마 삽입전극의 전류에 미치는 밀도 구배의 영향 (Influence of the Density Gradient on the Current of the Electrode Immersed in the Non-uniform Plasma)

  • 황휘동;구치욱;정경재;최재명;김곤호;고광철
    • 한국전기전자재료학회논문지
    • /
    • 제24권6호
    • /
    • pp.504-509
    • /
    • 2011
  • The conducting current of non-uniform plasma immersed electrode consists of ion current and secondary electron emission current caused by the impinging ion current. The ion current is determined by the ion dose passing through the sheath in front of electrode and the ion distribution in front of the electrode plays an important role in the secondary electron emission. The investigation of the distributed plasma and secondary electron effect on electrode ion current was carried out as the stainless steel electrode plugged with quartz tube was immersed in the inductively coupled Ar plasma using the antenna powered by 1 kw and the density profile was measured. After that, the negative voltage was applied by 1 kV~6 kV to measure the conduction current for the analysis of ion current.

M-shaped 파형을 이용한 작은 액적의 잉크젯 프린팅 (Inkjet Printing of Small Droplets Using M-shaped Waveforms)

  • 홍송은;최지호;김기은;박종운
    • 반도체디스플레이기술학회지
    • /
    • 제20권3호
    • /
    • pp.51-56
    • /
    • 2021
  • Using an inkjet printing process, we have investigated a droplet formation of poly(3,4-ethylenedioxythiophene): poly(styrenesulfonate) (PEDOT:PSS) near the orifice of a piezoelectric inkjet head. With an attempt to form the smallest droplet without any satellites, we have applied various waveforms such as the unipolar, bipolar, and M-shaped waveforms. It is found that the droplet velocity and volume vary depending sensitively on the waveform width and voltage. Of those, the M-shaped waveform is shown to provide the smallest droplet volume, followed by the bipolar and then unipolar waveforms. The droplet printed on a PET film roll by the M-shaped waveform has the diameter as small as 46.1 ㎛. It is likely that the second short unipolar in the M-shape waveform increases the droplet velocity gradient, rendering the droplet smaller.

Properties of Single $K^{+}$ Channels of Skeletal Muscle Incorporated into Planar Lipid Bilayer

  • Park, Jin-Bong;Kim, Hee-Jeong;Cho, Myung-Haing;Lee, Hang;Park, Hong-Ki;Lee, Mun-Han;Ryu, Pan-Dong
    • The Korean Journal of Physiology
    • /
    • 제29권1호
    • /
    • pp.13-27
    • /
    • 1995
  • single $K^{+}$ channels of skeletal muscle from the rat and frog were into planar lipid bilayers and their properties were studied. Fusion was induced by an osmotic gradient. Of the four types of $K^{+}$ channels recorded, the two most frequently observed were a voltage and $Ca^{2+}-activated$ $K^{+}$ channel and a $K^{+}$ channel with a prominent conductance substate. The first $K^{+}$ channel was identified as the large $Ca^{2+}-activated$ $K^{+}$ (BK) channel because the open-state probability was increased with depolarization (e-fold change per $10.6{\pm}3.5$ mV, n=8) and internal $Ca^{2+}$ (half-activation at $16.7{\pm}3.8$ mV, n=8, pCa 4) and its conductance was large ($247{\pm}4.9$ pS, n=24 in 0.1 M KCI). Lifetime distributions of open- and closed-states could be fitted with single exponentials of several milliseconds. The mean open- and closed-lifetimes were linearly dependent on the intracellular $[Ca^{2+}]$ and $1/[Ca^{2+}]$, respectively. The second $K^{+}$ channel showed a conductance substate at $30{\sim}60%$ of the open state. Its current-voltage relation was linear in the range of $-80\;{\sim}\;+80\;mV$. The slope conductance of the substate and open-state were 40 and 144 pS in 0.2 M KCl, respectively. The channel was highly selective for $K^{+}$ over Cl. The open-state probability was weakly voltage-dependent (e-fold change per 35 mV. The lifetime distributions of open- and closed-states were fitted with two exponentials and the major gating occurred slowly at several hundred milliseconds. Based on the above results, we think the second type of $K^{+}$ channel is the sarcoplasmic reticulum $K^{+}$ (SRK) channel. In addition, both types of channel were also incorporated into the lipids extracted from the skeletal muscle. The channel properties recorded in the bilayers termed from synthetic and extracted lipids were qualitatively similar. Our data indicate that BK and SRK channels are rich in the skeletal muscle and their properties and regulation could be effectively studied in planar lipid bilayer.

  • PDF

붕소가 도핑된 리튬이온전지용 양극 활물질(LiNi0.90Co0.05Ti0.05O2)의 전기화학적 특성 (Electrochemical Properties of Boron-doped Cathode Materials (LiNi0.90Co0.05Ti0.05O2) for Lithium-ion Batteries)

  • 김근중;박현우;이종대
    • Korean Chemical Engineering Research
    • /
    • 제57권6호
    • /
    • pp.832-840
    • /
    • 2019
  • 양극 활물질의 전기화학적 성능을 개선하기 위하여, 농도 구배형 전구체를 사용한 boron-doped $LiNi_{0.90}Co_{0.05}Ti_{0.05}O_2$를 합성하였다. 제조된 양극 활물질의 특성은 XRD, SEM, EDS, PSA, ICP-OES 및 전기전도도 측정을 통하여 분석하였다. 초기 충 방전 용량, 사이클, 순환전압전류, 율속 특성 및 임피던스 테스트를 통해 전기화학적 성능을 조사하였다. 붕소가 0.5 mol% 도핑된 $LiNi_{0.90}Co_{0.05}Ti_{0.05}O_2$ 양극 활물질은 2.7~4.3 V (vs. $Li/Li^+$)의 전압 범위에서 0.5 C의 전류를 인가했을 때, 187 mAh/g의 용량을 보이며 50 사이클 이후 94.7%의 용량 유지율을 보였다. 상대적으로 고전압인 2.7~4.5 V (vs. $Li/Li^+$)의 전압 범위에서는 200 mAh/g의 높은 용량을 보이며 50 사이클 이후 80.5%의 용량 유지율을 나타냈다.

Development of Hard-wired Instrumentation and Control for the Neutral Beam Test Facility at KAERI

  • Jung Ki-Sok;Yoon Byung-Joo;Yoon Jae-Sung;Seo Min-Seok
    • Journal of Electrical Engineering and Technology
    • /
    • 제1권3호
    • /
    • pp.359-365
    • /
    • 2006
  • Since the start of the KSTAR (Korea Superconducting Tokamak Advanced Research) project, Instrumentation and Control (I&C) of the Neutral Beam Test Facility (NB-TF) has been striving to answer diverse requests arising from various facets during the project's development and construction phases. Hard-wired electrical circuits have been designed, tested, fabricated, and finally installed to the relevant parts of the system. In relation to the vacuum system I&C, controlling functions for the rotary pumps, a Roots pump, two turbomolecular pumps, and four cryosorption pumps have been constructed. I&C for the ion source operation are the temperature and flow rate signal monitoring, Langmuir probe signal measurements, gradient grid current measurements, and arc detector circuit. For the huge power system to be monitored or safely operated, many temperature measurement functions have also been implemented for the beam line components like the neutralizer, bending magnet, ion dump, and calorimeter. Nearly all of the control and probe signals between the NB test stand and the control room were made to be transmitted through the optical cables. Failures of coolant flow or beam line vacuum pressure were made to be safely blocked from influencing the system by an appropriate interlock circuit that will shut down the extraction voltage application to the system or prevent damages to the vacuum components. Preliminary estimation of the beam power through the calorimetric measurement shows that 87.9% of the total power of the 60kV/18A beam with 200 seconds duration is absorbed by the calorimeter surface. Most of these I&C results would be highly appropriate for the construction of the main NBI facility for the KSTAR national fusion research project.

미세유체칩내 electrode의 opening window형태에 따른 유전전기영동력 특성 규명 (Characterization of Dielectrophoretic Force for the Structural Shapes of Window in Microfluidic Dielectrophoretic Chip)

  • 이재우;곽태준;윤대성;이상우
    • 대한의용생체공학회:의공학회지
    • /
    • 제34권4호
    • /
    • pp.189-196
    • /
    • 2013
  • Dielectrophoresis(DEP) is useful in manipulation and separation of micro-sized particles including biological samples such as bacteria, blood cells, and cancer cells in a micro-fluidic device. Especially, those separation and manipulation techniques using DEP in combination of micro fabrication technique have been researched more and more. Recently, it is revealed that a window structure of insulating layer in microfluidic DEP chip is key role in trap of micro-particles around the window structure. However, the trap phenomenon-driven by DEP force gradient did not fully understand and is still illusive. In this study, we characterize the trap mechanism and efficiency with different shapes of window in a microfluidic DEP chip. To do this characterization, we fabricated 4 different windows shapes such as rhombus, circle, squares, and hexagon inside a micro-fluidic chip, and performed micro-sized particles manipulation experiments as varying the frequency and voltage of AC signal. Moreover, the numerical simulation with the same parameters that were used in the experiment was also performed in order to compare the simulation results and the experimental results. Those comparison shows that both results are closely matched. This study may be helpful in design and development of microfluidic DEP chip for trapping micro-scaled biological particle.

400cc급 소형엔진 흡기포트의 성능 개발 (Performance Development of 400cc Small Engine Intake Port)

  • 박윤서;최두석;이주형;신평우;박성영
    • 한국산학기술학회논문지
    • /
    • 제13권3호
    • /
    • pp.977-985
    • /
    • 2012
  • 본 연구에서는 유동해석과 실험을 통하여 소형엔진 흡기포트의 성능 최적화를 수행하였다. 포트각, 플랜지면적 및 포트형상은 흡기포트의 성능을 결정하는 중요한 설계인자이다. 특히 가공곡률이 공기유량계수에 매우 중요한 영향을 미치는 핵심인자임을 확인하였다. 포트각과 플랜지면적이 증가하면, 흡기포트내의 압력분포와 압력기울기가 개선되어 공기유량계수가 개선되었다. 유동해석 결과는 플로우박스 실험결과 대비 최대 8% 오차를 보였으나, 설계변수에 따른 공기유량계수 경향을 우수하게 반영하였다. 최적의 설계변수를 적용한 흡기포트 모델은 양산모델 대비 약 4.5% 개선된 공기유량계수 성능을 나타내었다.

나노 코팅된 PDB를 이용한 동전기 지반개량 공법의 현장 적용성에 관한 연구 (A Study on Filed Application of Electro-Osmosis Soil Improvement Method with Nano-Coated Plastic Drain Baord)

  • 안상로;안광국
    • 한국지반환경공학회 논문집
    • /
    • 제19권10호
    • /
    • pp.5-11
    • /
    • 2018
  • PBD(Plastic Board Drain) 공법은 준설 매립에 효과적인 지반개량을 위한 다양한 공법 중 하나이며, 시공성 및 경제성이 우수해 연약지반개량에 많이 사용되고 있다. 그러나 PBD 공법은 장시간 소요에 의한 지반 투수성 감소 및 배수능 저하를 야기시키는 문제점을 지니고 있다. 이를 개선하기 위해 개발된 나노 코팅된 Plastic Drain Board(PDB)는 비금속성 전극재로 전기삼투공법의 전기력을 이용해 PDB 공법의 단점을 개선하기 위해 개발한 재료이다. 나노 코팅된 PDB를 적용하기 위한 다양한 연구가 수행되었으나 실내실험으로 제한되었을 뿐 현장실험은 수행되지 않았다. 이에 본 연구에서는 나노 코팅된 PDB의 현장 활용성을 확인하기 위해 실내모형실험과 현장실험을 수행하였다. 그 결과 일반 PDB에 비해 나노 코팅된 PDB의 지반개량효과가 크게 나타났다.