• Title/Summary/Keyword: Voltage Division

Search Result 1,118, Processing Time 0.033 seconds

Low-Power Direct Conversion Transceiver for 915 MHz Band IEEE 802.15.4b Standard Based on 0.18 ${\mu}m$ CMOS Technology

  • Nguyen, Trung-Kien;Le, Viet-Hoang;Duong, Quoc-Hoang;Han, Seok-Kyun;Lee, Sang-Gug;Seong, Nak-Seon;Kim, Nae-Soo;Pyo, Cheol-Sig
    • ETRI Journal
    • /
    • 제30권1호
    • /
    • pp.33-46
    • /
    • 2008
  • This paper presents the experimental results of a low-power low-cost RF transceiver for the 915 MHz band IEEE 802.15.4b standard. Low power and low cost are achieved by optimizing the transceiver architecture and circuit design techniques. The proposed transceiver shares the analog baseband section for both receive and transmit modes to reduce the silicon area. The RF transceiver consumes 11.2 mA in receive mode and 22.5 mA in transmit mode under a supply voltage of 1.8 V, in which 5 mA of quadrature voltage controlled oscillator is included. The proposed transceiver is implemented in a 0.18 ${\mu}m$ CMOS process and occupies 10 $mm^2$ of silicon area.

  • PDF

고전압 개폐장치의 보조회로 및 제어회로에 대한 환경시험 검토(2) (A Study on Environmental Tests for Auxiliary and contol circuits of HV Switchgears and controlgears(2))

  • 이정기;박영창;정주영;김익수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2009년도 제40회 하계학술대회
    • /
    • pp.1443_1444
    • /
    • 2009
  • A study on the environmental tests for auxiliary and control circuits of high voltage switchgears, especially testing condition and requirements, according to the relevant international standards has been briefly reviewed in this paper. As the highest supply voltage of electric power systems have been progressed, testing techniques and testing standards such IEC codes improved and revised keeping step with it. Especially IEC 62271 series, which are applicable to the HV-class switchgears and controlgears have been revised in 2008 newly. In this paper, the special consideration and background information of environmental testing condition with mechanical operating performance, e.g. operation in a higher and lower ambient temperature, for the auxiliary and control circuits of switchgears and controlgears and considerable investigation to the related international standards have been provided. Examples of testing performed were showed and analysis of their test results have been described.

  • PDF

Experimental Analysis on the Anodic Bonding with Evaporated Glass Layer

  • Choi, Woo-Beom;Ju, Byeong-Kwon;Lee, Yun-Hi;Jeong, Seong-Jae;Lee, Nam-Yang;Koh, Ken-Ha;Haskard, M.R.;Sung, Man-Young;Oh, Myung-Hwan
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1996년도 하계학술대회 논문집 C
    • /
    • pp.1946-1949
    • /
    • 1996
  • We have performed silicon-to-silicon anodic bonding using glass layer deposited by electron beam evaporation. Wafers can be bonded at $135^{\circ}C$ with an applied voltage of $35V_{DC}$, which enables application of this technique to the vacuum packaging of microelectronic devices, because its bonding temperature and voltage are low. From the experimental results, we have found that the evaporated glass layer more than $1\;{\mu}$ m thick was suitable for anodic bonding. The role of sodium ions for anodic bonding was also investigated by theoretical bonding mechanism and experimental inspection.

  • PDF

YBCO Coated Conductor의 과전류 특성해석 (Analysis of Over-current Characteristics in YBCO Coated Conductor)

  • 이찬주;남관우;강형구;고태국;석복렬
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 B
    • /
    • pp.693-694
    • /
    • 2006
  • In order to develop a high temperature superconducting(HTS) coil for the fault current limiter(FCL), the over-current characteristics in YBCO coated conductor(CC) with Ni-W alloy substrate are analyzed. The HTS wire is wound by bifilar winding method for resistive current limitation and it is operated in 65K sub-cooled nitrogen. In order to analyze the resistance and the temperature characteristics of the CC wire, an analysis program is developed considering all the composition materials except the buffer layer. Using this program, the temperature rise, the resistance development and the current limitation of CC are calculated depending on the applied voltage and the stabilizer materials. According to the analysis results, under the temperature restriction of 300K, the maximum voltage per meter is determined as 40V/m if the stabilizer is $25{\mu}m$ thick stainless steel at each side. Finally, the wire length needed for the distribution level HTS FCL is estimated.

  • PDF

선박용 LED Chamber Light의 열 및 광학 특성에 관한 연구 (A Study on the Thermal and Optical Properties of a LED Chamber Light for Vessels)

  • 김상현;이도엽;김우성;장낙원
    • 한국전기전자재료학회논문지
    • /
    • 제28권1호
    • /
    • pp.57-63
    • /
    • 2015
  • Recently, LED is widely used in the kinds of display devices or lighting. In this paper, we fabricated LED chamber light for naval vessels to replace to conventional chamber light using incandescent lamp. The LED package of chamber light was designed with luminous intensity of 5.5 cd, color temperature of $6,000{\pm}500K$, forward voltage of 3~3.2 V and input current of 60 mA. A LED module was composed of 36 LED packages and metal PCB. The VF and luminous intensity of LED package were getting down when temperature increased. The temperature of LED chamber light was measured by changing the number of LED package and applied current for one hour when an electric current flow. The heat transfer capability have been improved by using metal PCB. The power consumption of LED chamber light reduced by 86% compared to the conventional chamber light using incandescent lamp.

고전압 이용한 준설퇴적토 유효성 및 중금속 변화에 관한 연구 (Study of Effectiveness of using higher voltages in analysis of dredged sediments and heavy metal concentration)

  • 권기범;김상근;;유준;정하익
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2008년도 추계 학술발표회
    • /
    • pp.1446-1451
    • /
    • 2008
  • The clay found in the river or in any waste water treatment plant usually have a very high content of water. A large amount of sediments hinder the navigation in river. In waste water treatment plant, there is requirement of settling the thick sludge. These problems are overcome by using rapid means of sedimentation and settling. This paper focus on how method of Electrokinetic sedimentation can be made faster. Sedimentation using Electrokinetic phenomenon has been discussed with varied voltage applied and effect and dose of coagulant in increasing the process. The experimental test has been carried out at water content that are generally present in the case of river and small canals carrying waste water. This paper also focus on different heavy metals concentration during the process and the power aspects of process. A series of experiment were done to support the proposed theory and how a bubble formation could hinder the purpose of experiment.

  • PDF

Synchrotron radiation photoelectron spectroscopy study of oxygen doping effect by oxygen plasma treatment to inverted top emitting organic light emitting diodes

  • Hong, Ki-Hyon;Kim, Ki-Soo;Kim, Sung-Jun;Choi, Ho-Won;Tak, Yoon-Heung;Lee, Jong-Lam
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2009년도 9th International Meeting on Information Display
    • /
    • pp.118-120
    • /
    • 2009
  • We reported that the evidence of oxygen doping to copper-phthalocyanine (CuPc) by $O_2$-plasma treatment to Au electrode of inverted top emitting organic light emitting diodes (ITOLEDs). The operation voltage of OLEDs at 150 mA/$cm^2$ decreased from 16.1 to 10.3 V as oxygen atoms indiffued to CuPc layer using $O_2$-plasma. Synchrotron radiation photoelectron spectroscopy results showed that a new bond of Cu-O appeared and the energy difference between the highest occupied molecular orbital and $E_F$ is lowered by 0.20 eV after plasma treatment. Thus the hole injection barrier was lowered, reducing the turn-on voltage and increasing the quantum efficiency of OLEDs.

  • PDF

3상 전원 조건의 모터 구동 인버터 내압 저감을 위한 공진 강압형 DC/DC 컨버터 (Resonant Step-Down DC/DC Converter to Reduce Voltage Stresses of Motor Driving Inverter under 3-phase AC Utility Line Condition)

  • 강경수;김상언;이준환;노정욱
    • 전력전자학회논문지
    • /
    • 제19권5호
    • /
    • pp.391-398
    • /
    • 2014
  • This paper presents a resonant step-down DC/DC converter to reduce the voltage stresses of a 3-phase inverter module under the three-phase AC utility line condition. Under this condition, a conventional 3-phase inverter module suffers from high voltage stresses as a result of the high rectified DC link voltage; hence, a high-cost high-voltage-rating inverter module must be used. However, using the proposed converter, a low-cost low-voltage-rating inverter module may be adopted to drive the motor even under the 3-phase AC line condition. The proposed converter, which can be realized with small size inductor and low-voltage-rating semiconductor devices, operates at a high-efficiency mode because of the zero-current switching operations of all the semiconductor devices. The operational principles are explained and a design example is provided in the study. Experimental results demonstrate the validity of the proposed converter.

Coordinated Control of Reactive Power between STATCOMs and Wind Farms for PCC Voltage Regulation

  • Nguyen, Thanh Hai;Lee, Dong-Choon;Van, Tan Luong;Kang, Jong-Ho
    • Journal of Power Electronics
    • /
    • 제13권5호
    • /
    • pp.909-918
    • /
    • 2013
  • This paper proposes a coordinated control of the reactive power between the STATCOMs (static synchronous compensators) and the grid-side converters (GSC) of wind farms equipped with PMSGs (permanent-magnet synchronous generators), by which the voltage fluctuations at the PCC (point of common coupling) are mitigated in the steady state. In addition, the level of voltage sags is reduced during grid faults. To do this, the GSC and the STATCOM supply reactive power to the grid coordinately, where the GSCs are fully utilized to provide the reactive power for the grid prior to the STATCOM operation. For this, the GSC capability of delivering active and reactive power under variable wind speed conditions is analyzed in detail. In addition, the PCC voltage regulation of the power systems integrated with large wind farms are analyzed for short-term and long-term operations. With this coordinated control scheme, the low power capacity of STATCOMs can be used to achieve the low-voltage ride-through (LVRT) capability of the wind farms during grid faults. The effectiveness of the proposed strategy has been verified by PSCAD/EMTDC simulation results.

PPS 제어기법을 적용한 48V-400V 비절연 양방향 DC-DC컨버터 (A 48V-400V Non-isolated Bidirectional Soft-switching DC-DC Converter for Residential ESS)

  • 정현주;권민호;최세완
    • 전력전자학회논문지
    • /
    • 제23권3호
    • /
    • pp.190-198
    • /
    • 2018
  • This paper proposes a nonisolated, bidirectional, soft-switching DC - DC converter with PWM plus phase shift (PPS) control. The proposed converter has an input-parallel/output-series configuration and can achieve the interleaving effect and high voltage gains, resulting in decreased voltage ratings in all related devices. The proposed converter can operate under zero-voltage switching (ZVS) conditions for all switches in continuous conduction mode. The power flow of the proposed converter can be controlled by changing the phase shift angle, and the duty is controlled to balance the voltage of four high voltage side capacitors. The PPS control device of the proposed converter is simple in structure and presents symmetrical switching patterns under a bidirectional power flow. The PPS control also ensures ZVS during charging and discharging at all loads and equalizes the voltage ratings of the output capacitors and switches. To verify the validity of the proposed converter, an experimental investigation of a 2 kW prototype is performed in both charging and discharging modes under different load conditions and a bidirectional power flow.