• Title/Summary/Keyword: Voltage Division

Search Result 1,118, Processing Time 0.032 seconds

A Study on about Implementation to Induction Cooker that load Turbo Inverter algorithm (터보 인버터 알고리즘을 탑재한 유도가열 조리기 구현에 관한 연구)

  • Lee Min-Kie;Koh Kang-Hoon;Kwon Soon-Kurl;Lee Hyun-Woo
    • Proceedings of the KIPE Conference
    • /
    • 2001.07a
    • /
    • pp.331-334
    • /
    • 2001
  • The voltage resonating inverter has a defect in switching element that works at 5 or 6times higher than input voltage. Especially, it is very difficult to choose the switching device is very high for the 220(V)commercial voltage. In this paper, it is proposed the optimum method to realize the turbo 2000(W) power for induction cooker that is employed the 900(V) IGBT with decreasing operating voltage of the switching component by making the 220(V), 1500(W) inverter through the claim mode voltage resonating inverter.

  • PDF

Study on the high precision output of 50kV high-voltage inverter (50kV 고전압 인버터 고정밀 출력설계에 관한 연구)

  • Son, Y.G.;Suh, J.H.;Oh, J.S.;Cho, M.H.
    • Proceedings of the KIEE Conference
    • /
    • 2005.07c
    • /
    • pp.2199-2201
    • /
    • 2005
  • High voltage power supply with pulse load($4.5{\mu}s$ and PRF 60Hz) condition is investigated which is of interest for applications like Klystron modulator power supplies with output voltage of 50kV. The performance specifications with this type of power supplies are very stringent demanding tight regulation(<0.01%) and high efficiency(> 85%). The solution to this problem as a single stage converter is very difficult. The final output voltage is obtained as sum of the output of SCPS & PCPS. The combination of the two stages can satisfy the pulse load specifications. The analysis of the voltage and power division between SCPS & PCPS has been done for the proposed topology. It has studied under various operating conditions of line and load. Simulation results are validated by experimental results.

  • PDF

Voltage Control in a Novel Three-Phase Line Interactive UPS System with Parallel-Series Active Power Line Conditioning Capabilities using AC Line Reactor (AC 라인 리액터와 병렬 및 직렬 능동필터를 가지는 새로운 3상 Line-Interactive UPS 시스뎀의 전압제어)

  • Ji, Jun-Keun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.7 no.6
    • /
    • pp.1072-1077
    • /
    • 2006
  • In this paper a novel 3-phase line interactive UPS(Uninterruptible Power Supply) system with parallel-series active power-line conditioning capability using AC line reactor and two four-leg PWM VSCs(Voltage Source Converters) is proposed. And the strategy of voltage control in proposed UPS system is explained. The objective of voltage control in parallel(shunt) and series PWM VSC of proposed UPS system is to guarantee satisfactory characteristics in steady state and transient state.

  • PDF

Optimal Design of a Follow Current Disconnector for DC Arresters in Traction Vehicles

  • Wang, Guoming;Kim, Sun-Jae;Park, Seo-Jun;Kil, Gyung-Suk;Ji, Hong-Keun
    • Transactions on Electrical and Electronic Materials
    • /
    • v.17 no.5
    • /
    • pp.289-292
    • /
    • 2016
  • This paper dealt with the optimal design of a follow current disconnector for DC arresters used in electric traction vehicles. The disconnector separates the ground lead from an arrester to prevent a line-to-ground fault of an aged arrester and should not affect the operation and function such as the reference and the clamping voltage of the connected arrester. The designed disconnector is composed of a resistor, a spark gap, and a cartridge. The results showed that the sparkover voltage increased with the gap distance whereas the reference voltage was almost the same as that without the disconnector. The sparkover voltage was 3.95 kV when the gap distance was 0.5 mm. Regardless of the gap distance, the reference and the clamping voltage of the assembled disconnector with an arrester were measured to be the same as those of the arrester alone.

DC-Voltage Regulation for Solar-Variable Speed Hybrid System (태양광 기반의 가변속 하이브리드 시스템을 위한 직류 전압 제어)

  • Niyitegeka, Gedeon;Lee, Kyungkyu;Choi, Jaeho;Song, Yujin
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.21 no.3
    • /
    • pp.231-237
    • /
    • 2016
  • Recently, the interest in DC systems to achieve more efficient connection with renewable energy sources, energy storage systems, and DC loads has been growing extensively. DC systems are more advantageous than AC systems because of their low conversion losses. However, the DC-link voltage is variable during operation because of different random effects. This study focuses on DC voltage stabilization applied in stand-alone DC microgrids by means of voltage ranges, power management, and coordination scheme. The quality and stability of the entire system are improved by keeping the voltage within acceptable limits. In terms of optimized control, the maximum power should be tracked from renewable resources during different operating modes of the system. The ESS and VSDG cover the power shortage after all available renewable energy is consumed. Keeping the state of charge of the ESS within the allowed bands is the key role of the control system. Load shedding or power generation curtailment should automatically occur if the maximum tolerable voltage variation is exceeded. PSIM-based simulation results are presented to evaluate the performance of the proposed control measures.

A Study on the Disinfection of Coliform Group in the Effluent of Sewage Plant by High Voltage Electric Field Treatment (고전압 전기장을 이용한 하수처리장 방류수 중의 대장균군 소독에 관한 연구)

  • Lee, Min-Gyu;Chung, Geun-Sik;Kam, Sang-Kyu
    • Journal of Environmental Science International
    • /
    • v.17 no.7
    • /
    • pp.817-826
    • /
    • 2008
  • Using high voltage electric fields induced by high voltage AC (10-12 kV/cm, 20 kHz) and pulsed (20-30 kV/cm, 40 Hz) electric field generator as a semipermanent and environment-friendly disinfecting apparatus, the disinfection effect of coliform group in the effluent of sewage plant was investigated. The effects of electric field strength, treatment time, discharge area of a discharge tube, water quality factors (electric conductivity, pH and SS) on its death rate were examined. The death rate of coliform group was increased with increasing electric field strength and treatment time. For AC and pulsed electric field generator, the critical electric field strength was 6 kV/cm and 2 kV/cm, respectively, and the critical treatment time was 5 min and 2 min, respectively, regardless of electric field strength. Comparing the death rate of coliform group by AC and pulsed electric fields used in this study, its death rate was higher for the latter than the former, but did not increase linearly with increasing electric field strength. The results obtained for the effects of discharge area, electric conductivity, pH and SS on the death rate of coliform group using AC electric field (12 kV/cm, 20 kHz) were as follows: its death rate showed the trend to increase linearly with increasing discharge area; for the effect of electric conductivity, its death rate was increased with increasing electric conductivity, regardless of ionic species, increased with increasing cationic valency, but was similar between the same cationic valency; the pH $5{\sim}9$ used in this study did not affect its death rate; its death rate was decreased with increasing SS concentration.

Low Power Current mode Signal Processing for Maritime data Communication (해상 데이터 통신을 위한 저전력 전류모드 신호처리)

  • Kim, Seong-Kweon;Cho, Seung-Il;Cho, Ju-Phil;Yang, Chung-Mo;Cha, Jae-sang
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.8 no.4
    • /
    • pp.89-95
    • /
    • 2008
  • In the maritime communication, Orthogonal Frequency Division Multiplexing (OFDM) communication terminal should be operated with low power consumption, because the communication should be accomplished in the circumstance of disaster. Therefore, Low power FFT processor is required to be designed with current mode signal processing technique than digital signal processing. Current- to-Voltage Converter (IVC) is a device that converts the output current signal of FFT processor into the voltage signal. In order to lessen the power consumption of OFDM terminal, IVC should be designed with low power design technique and IVC should have wide linear region for avoiding distortion of signal voltage. To design of one-chip of the FFT LSI and IVC, IVC should have a small chip size. In this paper, we proposed the new IVC with wide linear region. We confirmed that the proposed IVC operates linearly within 0.85V to 1.4V as a function of current-mode FFT output range of -100~100[uA]. Designed IVC will contribute to realization of low-power maritime data communication using OFDM system.

  • PDF

Mechanical and Electrical Performance of 180kV HVDC Submarine Cable System (180kV HVDC 해저케이블 기계적/전기적 특성 평가)

  • Kim, N.Y.;Lee, T.H.;Lee, S.J.;Ji, B.K.;Kim, J.N.;Jeon, S.I.;Yun, H.S.;Joung, S.K.;Kang, C.H.;An, Y.H.
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.616-618
    • /
    • 2007
  • This paper describes the mechanical and electrical test on HVDC submarine cable, Flexible Repair Joint and termination for 180kV. This HVDC submarine cable was manufactured using LS cable's unique skill and would be applied the HVDC submarine cable system in korea. The performance test consist of mechanical test and electrical test. The tensile bending test and tensile test was done as the mechanical test and Electrical test is DC voltage and Impulse test. The tensile bending test carried out 6 times(double of specified times) for maximum reliability. The DC test voltage is $\pm$400kV/1hr. We estimate the lower limit of DC breakdown voltage is 600kV. The impulse test voltage is $\pm$800kV/10shots. The type of developed cables is the MI type. Its insulation consist of paper tapes impregnated with a high viscosity oil. The development of new HVDC cable is available for HVDC underground or submarine power transmission. The developed HVDC cable, FRJ and termination have passed the mechanical and electrical test successfully and showed excellent performance.

  • PDF

Control of The Soft Starter using Bluetooth (Bluetooth를 이용한 Soft Starter 제어)

  • Bae, Jong-Il;Hwang, Yeong-Yeun;Lee, Dong-Cheol;Bae, Cheol-Min
    • Proceedings of the KIEE Conference
    • /
    • 2005.07d
    • /
    • pp.2735-2737
    • /
    • 2005
  • Been using widely Soft Starter control system is $Y-{\Delta}$ method, Reactor method, Resistor method etc. and this methods are big mobile warfare kind and voltage drop and can not operate because suspending load because smallest operation acceleration Torque is small.

  • PDF

A New Pixel Structure for Active-Matrix Organic Light Emitting Diode

  • Choi, Sang-Moo;Kwon, Oh-Kyong
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2003.07a
    • /
    • pp.881-884
    • /
    • 2003
  • We propose a new pixel structure for Active Matrix OLED (AMOLED). The proposed pixel structure can display full color images by compensating threshold voltage (Vth) variation of driving TFTs. And we obtain an improved contrast ratio(C/R) of higher than 600:1

  • PDF